DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Similar documents
Table of Contents. 1 - Specifications Installation Wiring User controls...7

RF 1. Contents: Connecting diagram. Detailed information:

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

HERZ-Thermal Actuators

Installation Guide. DEVIreg 530. Electronic Thermostat.

Drayton Digistat +2RF/+3RF

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

GB/DAS User Instruction

T0118 T2118 T3118. Instruction Manual

Operating Instructions. Room temperature controller

T5000 T000 LCD Digital Fan Coil Thermostat

EK908FHL - Thermostat for floor heating

INSTALLATION AND OPERATION MANUAL

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Duct Humidity Transmitter

HMI display Installation Guide

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Electronic Control Devices The European Product Catalogue 2007

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Install Guide 3M-50. Caution. Caution

Split Controller. User Manual SM-SS-F 2009/01/04

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

How To Use A Power Supply On A Powerline 2.2 (Ai)

User Manual THR840DUK Digital Thermostat

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Electronic Control Devices The European Product Catalogue 2007

Inwall Room Temperature Unit

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

3M Wrist Strap and Footwear Tester 740. User s Guide

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

USER S MANUAL HSC-24A

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Portable Air Conditioner

Construction Automotive Industry.

Product and Application Description

40.3. Control Relays and Timers

MOUNTING AND OPERATING INSTRUCTIONS

RRV934. Multi-controller. Synco living

Table of Contents. Introduction. Radio Frequency Control. Initial setup Setting the time. Setting the temperature

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Hygro-Thermometer + InfraRed Thermometer Model RH101

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

Radiant Temperature Sensor TY7321

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

Auto Dialer. Manual E-921APQ E-921GPQ

TC-9102 Series Surface Mount Temperature Controllers

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Installation Instructions

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

T7079A,B Solid State Remote Temperature Controllers

Install Guide CT101. Caution. Caution

Niko Home Control. Installation Manual

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Instruction manual for models:

LIEBERT VNSA Installation Sheet

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

WD-AMX Water Detection Controllers

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

4.3-inch Back-Up Camera

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

DEVIreg 330 (+5 to +45 C)

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Wireless Indoor/ Outdoor Thermometer

Unica for KNX system 226

OZW30. Central Unit SYNERGYR

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Fan Coil EC Motor Control

MAGNUM Original Sauna Stove 6.6 kw 9.0 kw 10.5 kw MAGNUM Cenik and Lite Sauna Stoves 6.6 kw 9.0 kw 10.5 kw Use and Installation

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

STERILIZERS, LABORATORY DRYING OVENS

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

ECL Comfort 110 Application 130. Weather compensated flow temperature control of heating and boiler systems. Instructions

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Heating Controller. Building Technologies HVAC Products

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

AutoRanging Digital MultiMeter

Wireless 7 Day Programmable Room Thermostat

GaiaMoto Programmable Differential Temperature Controller

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Installation Guide. Programmable Thermostat TH6220D

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

AIR CONDITIONER INSTALLATION MANUAL

Transcription:

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS www.rehau.com Construction Automotive Industry

SCOPE This guide gives instruction regarding REHAU Programmable Digital Thermostat installation and operation. Thermostats may only be installed, calibrated and maintained by an appropriately trained installer of radiant systems. The installer should also have a basic understanding of electrical wiring and electronic controls. Throughout this document, the signal word NOTICE is used to help you avoid property damage. We cannot warn of all hazards; you must also use your own good judgment. ABOUT PROGRAMMABLE DIGITAL THERMOSTATS This 3-wire thermostat offers powerful capabilities with simple, easy to use menus. There is a reduced operating mode which may be used for nighttime and vacation periods. With the optional floor sensor, this thermostat can regulate either the floor or the room temperature or both, in which case the floor sensor is used as a temperature limiter, set to either high or low limit. This thermostat offers numerous programming options including the ability to: Exercise the system pump daily for 1 minute Define the thermostat to be operated as a simple on/off switch Use proportional integral regulation (PWM) anticipation logic Select a night reduction which automatically reduces the temperature by 7 F (4 C) Components Each thermostat (Art. No. 236487-001) comes complete with: Installation instructions Mounting template In addition, you will need: 10k floor sensor, where applicable No.1 Phillips head screw driver 1/8 in. flat head screw driver Mounting screws (typical for drywall installation) Drill Pencil Level 2

Table 1: Thermostat Technical Specifications Control Microprocessor control Material White PVC plastic Dimensions (H x W x D) 3 1/4 x 3 1/4 x 1 in (80 x 80 x 27 mm) Measured temperature precision 0.2 F (0.1 C) Packaged weight 0.26 lb (97 g) Floor limiting temperature range 50 to 104 F (10 to 40 C) Temperature regulation Proportional integral regulation (adjustable see installation menu) Cycle: 15 min. or static differential 1.8 F (1 C) Ambient conditions (indoor use only) 32 to 122 F (0 to 50 C), < 90% Electrical protection class Class II IP30 Power supply 24 V ±10% 60 Hz 15 W max Output TRIAC output 24 VC, 15W max (typical 4 actuators) Optional floor sensor NTC thermistor, 10 kω; 10 ft (3 m) cable (Art. No. 236497-001) Wire type Minimum of three conductor thermostat wires (18-24 AWG); four or eight conductor thermostat wires are recommended Thermostat Display Features j1 F 20.5 C OK/ 1 2 3 4 j1 F C 20.5 7 6 5 Fig. 1: Thermostat display features 1. Operating mode menu 2. Heating indication 3. Cooling indication 4. If symbol is displayed, the measured temperature is shown (position 5) 5. Measured temperature or set temperature 6. C or F indication 7. Title for installation parameters (J0,CLr ) 3

Thermostat Wiring Diagrams Fig. 2: Wiring diagram for operation without actuator Fig. 3: Wiring diagram for operation with actuator 4

MOUNTING THE THERMOSTAT Note: Thermostat must be mounted in the correct location to work properly. 1. Thermostat should be located 1.5 m (5 ft) above the finished floor. The thermostat must be installed on an interior wall. Avoid locations in drafts (e.g., staircases, air outlets), behind doors, in direct sunlight or near other heat sources. Min. 8 in (20 cm) 60 in (1.5 m) Fig. 4: Locating the thermostat 2. Make sure that wire is installed from control location to the desired thermostat location. 3. Use the mounting template (see Fig. 5) to help position the thermostat and drill the mounting holes. 4. Pull wires through access holes for thermostat wiring and floor sensor wiring (if applicable). Fasten the screws, but do not completely tighten the screws. 5. Adjust thermostat with a level and tighten the screws. 6. Put the cover on the thermostat and secure with Phillips head screw, using a No. 1 Phillips head screw driver. 7. Apply 24V power. WARNING: Turn off all power to the wires before connecting wires to terminals. Failure to turn off power can cause electrocution. 5

OK/ OK/ OK/ j1 F C 20.5 6

7

Table 3: Room Air and Floor Sensing Options Room Air Sensing Only Operation (J6) Room Air Sensing with Floor Lower Limit Room Air Sensing with Floor Upper Limit Floor Sensing Operation (J6), (FL) and (FH) When operating without a floor sensor, only the internal thermostat air sensor controls the call for heat. When operating with the optional floor sensor (Art. 236497-001), the thermostat is reading both the room air temperature and the floor temperature. The floor sensor will ensure that the floor will never drop below a certain temperature. The range of this temperature is 50 to 104 F (10 to 40 C). When operating with the optional floor sensor (Art. 236497-001), the thermostat is reading both the room air temperature and the floor temperature. The floor sensor will ensure that the floor will never rise above a certain temperature. The range of this temperature is 50 to 104 F (10 to 40 C). When operating with the optional floor sensor (Art. 236497-001), the floor sensor can completely control the call for heat with LOW (FL) and HIGH (FH) temperature limits. If (J6) is set to AIR, the thermostat continually monitors the room air temperature while also ensuring that the floor remains within the LOW and HIGH limits. (HIGH). Note: Operating with only a slab sensor can lead to either overheating or under heating of the space. 8

END USER INSTRUCTIONS Push the OK/ button on the thermostat to select the desired operating mode OFF Mode In this mode, the thermostat is off and the display goes blank. All program settings are saved. NOTICE: In this mode, the system can freeze. COMFORT Mode In this mode, the thermostat will continually maintain the temperature entered. When the sun is blinking, the desired heating temperature is set by pressing buttons and after a few seconds, the display switches back to the measured temperature, denoted by the symbol. REDUCED Mode In this mode, the thermostat automatically reduces the set temperature to your adjusted setback temperature. After a few seconds, the display switches back to the measured temperature, denoted by the symbol. EXTERNAL CLOCK Mode In this mode, the thermostat will work according to the comfort mode. This mode is currently not available. 9

10

APPENDIX MOUNTING TEMPLATE Clip page and use as mounting template Thermostat should be located 1.5 m (5 ft) above the finished floor 11

For updates to this publication, visit na.rehau.com/resourcecenter The information contained herein is believed to be reliable, but no representations, guarantees or warranties of any kind are made as to its accuracy, suitability for particular applications or the results to be obtained therefrom. Before using, the user will determine suitability of the information for user s intended use and shall assume all risk and liability in connection therewith. 2015 REHAU www.rehau.com rehau.mailbox@rehau.com 855.665 04.2015