THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

Similar documents
Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

Many Products...One Source

REGULATORS 175/153 Series

A99B Series Temperature Sensors

V47 Series Temperature Actuated Modulating Water Valves

Stainless Steel Single and Dual Circulation Kits

Self-operated Temperature Regulators Temperature Regulator Type 1u

79 GAUGE / THERMOMETER H N O

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

Submersion/Insertion Toroidal Sensor

TYPE E Main Valve Sizes 3 /8 through 12

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Installation Instructions

1. The Determination of Boiling Point

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Installation Instructions

! WARNING. Before using product, read and understand instructions.

Front axle components, overview

COMBINATION SLAB & TRIM SAW INSTRUCTIONS 12, 14, & 16 MODELS

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

1500 Follow Spot Yoke

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Toroidal Conductivity Sensor

CORPORATE PROFILE WINTERS INSTRUMENTS. MANUFACTURER OF INDUSTRIAL INSTRUMENTATION

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

NITROUS TRANSFER PUMP INSTRUCTIONS

2" & 3" Poly Wet Seal Pump Instruction Manual

Select Radiators Installation Guide

Tri-Homo Style Operation and Maintenance Instructions

15. Liquid-in-Glass Thermometry

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

B-Series Temperature Switches

Installation Instructions S

OWNER S MANUAL Table Tennis Table Patent Pending

Bimetal thermometer Model 52, industrial series

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Dew Point Tester. Instruction Manual. CVS Regular Chiller Model A-2. CVS Regular Chiller Model A-2

High Pressure Equipment High Pressure Valves, Fittings and Tubing

Fisher 249 Caged Displacer Sensors

Submersion/Insertion Toroidal Sensor

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

Thermometer in stainless steel with capillary and switch contacts

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

Beadboard Wall Bookcase

5800 Temperature Sensor Cable Assembly

1 DESCRIPTION OF THE APPLIANCE

DryWeight BulkVolume

THERMOCOUPLES GENERAL DESIGN AND SELECTION THERMOCOUPLE STANDARD

Thermostatic valve Type AVTA

Model 43AP Pneumatic Controller, Style B

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

STEERING HANDLEBAR/FRONT WHEEL/ FRONT SHOCK ABSORBER

VOYAGER 570G. 744A Sprayer Control

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Trace Dissolved Oxygen Sensor

Lathe Milling Attachment

Bimetal Operating Principle

758 Heavy-duty Ratchet Guy Wire Cutter

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

BOWIE PUMPS OPERATION - MAINTENANCE

Pipe Valves, Fittings and Nipples Pressures to 15,200 psi

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Parts Replacement Manual For DODGE TORQUE-ARM Speed Reducers Straight Bore & Taper Bushed

Powers Controls TH 192 S Single Temperature Room Thermostat

Installation Instructions

M1A/M14 5/8-24 thread adapter Installation Instructions

Rebuild Instructions for and Transmission

Operating Instructions

Wafer Check Valve ASAHI AV VALVES. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Trunnion-Design Ball Valves

White Industries Rear Hub Instructions

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.

1.8 CRANKSHAFT OIL SEALS

INSTALLATION AND OPERATION INSTRUCTIONS NOT FOR OXYGEN OR OTHER OXIDIZING GASES

Installation Instructions

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS

SELECTION, APPLICATION & MAINTENANCE

Threaded Resistance Thermometers Model TR10-D, Miniature Design

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

PARTS NEEDED FOR CONVERTING FROM LP TO NG

Before installation it is important to know what parts you have and what the capabilities of these parts are.

James M. Pleasants Company

Calibration of Volumetric Glassware

Machine needle shut-off nozzle type HP

ZHM Series Installation and Operating Instructions

NONSUCH SPARS Recommended Owner s Maintenance Schedule

Transcription:

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE www.winters.com MANUFACTURER OF INDUSTRIAL INSTRUMENTATION

Bi-Metal Thermometers Bi-Metal Thermometers Winters bi-metal thermometers are direct sensing instruments that are hermetically sealed and thus completely waterproof and dustproof. For accurate temperature readings, the stem should be immersed past the groove on the lower portion of the stem. All bi-metallic thermometers are of 304 stainless steel construction to protect against corrosive conditions. An external adjustment screw is conveniently located on the bottom of each case for easy field recalibration of thermometers, which may have shifted out of accuracy. Installation of Bi-Metal Thermometers Location Vibration and extreme ambient temperatures can affect the dial reading. These areas should be avoided as much as possible. Vibration effects can be minimized by the use of a dampening liquid such as glycerin or silicone. If vibration is extreme, then a remote reading filled thermometer should be considered. Mounting A suitable thread sealant is required for NPT threads such as pipe dope or Teflon tape. Never use any part of the thermometer other than the hex nut that is on the stem of the thermometer just above the NPT threads for installation. Always tighten with a wrench on the hex nut. Failure to do so will severely damage the thermometer. Typically, bimetal thermometers are connected to the process through a thermowell. This allows for the removal and testing, calibration or replacement of the instrument without affecting the process operations. The selection of thermowell material and stem lengths is critical in order to properly monitor the temperature of the process. Operation and Maintenance of Bi-Metal Thermometers Disassembly and Assembly / Spare Parts It is not recommended to disassemble the thermometer for any reason. If the thermometer is not functioning properly or if the lens is broken, the thermometer should be replaced. Please contact Winters for this. Inspection Frequency These thermometers are ruggedly constructed to give a reliable process temperature reading. The frequency of inspection is dependent on how critical the reading is at that point in the process. The inspection frequency can range from monthly to annual basis. Over Range Protection Over range protection allows the thermometer to function within its designed parameters even when the media temperature may intermittently exceed the thermometer range. The over range protection is 50% for ranges up to 500 F (260 C) and 10% above ranges of 500 F (260 C). Recalibration A master thermometer with a high degree of accuracy should be used for calibration. Immerse the bi-metal thermometer along side the master thermometer into an agitated liquid for at least three minutes and compare temperature readout. Note that both thermometers must be immersed at the same level. An external adjustment screw is conveniently located on the bottom of the case for easy field calibration. Winters can recalibrate and provide test certification. Please contact us for more details. Storage Store in a dry area at ambient temperatures not exceeding the indicator range. For example, if the indicator range is 0 C to 300 C, then the storage temperature should not exceed 300 C. Teflon is a registered trademark of DuPont Corporation 2 Tel: 1-800-WINTERS / www.winters.com

Bi-Metal Thermometers Head Rotation NOTE: The bi-metal thermometer head can be rotated as illustrated only when in back connection position. Never rotate the thermometer head when it is in the angled position. A To rotate thermometer head up to 360, make certain thermometer is in back connected position. Loosen two screws on both sides (A) until harness revolves freely. Now hold thermometer head and adjustable harness and rotate head to desired position. Retighten screws (A). Angle Positioning B To tilt thermometer head up to a 90 angle or straighten it, loosen single screw (B) by 1 /2 turn only. B Tilt to desired angle or straighten. Retighten screw (B). Tel: 1-800-WINTERS / www.winters.com 3

Liquid-in-glass Thermometers Liquid-in-glass Thermometers Liquid-in-glass thermometers have a glass tube in front of a metal scale. It extends into a metal chamber and has a glass bulb attached. This tube is completely sealed and the bulb contains a predetermined amount of liquid which, on expanding and contracting caused by temperature changes, will indicate the temperature for a given temperature range. Installation of Liquid-in-glass Thermometers NOTE: Make sure that while connecting the thermometer to the process, the sensitive portion of its stem (the last 2½ from the end) is located well within the flow of the medium being measured for temperature. This will ensure accurate readings with minimal response time. 2 ½ minimum immersion Accuracy Inaccuracy may be caused by a broken tube, scale shifting in slots from original position, liquid separation, sensitive bulb not fully immersed in the media, or by poor circulation. Poor circulation can be explained as follows: If there is poor agitation in a fluid, the temperature stratifies or has hot or cold spots. The thermometer will read only the temperature in which the sensitive bulb is immersed. It is, therefore, important to locate on installation the sensitive bulb in the correct position. Corrosion The use of separate sockets of special material is recommended for corrosive or highly abrasive service. Location Care should be taken to locate the instrument on the equipment where vibration is at a minimum. Thermowell Connection Remove the thermowell from the thermometer if supplied with it. Install this thermowell in the pipeline or service as required. Insert the stem of the thermometer through the thermowell. Position thermometer for best reading position and tighten down. If the thermowells are purchased separately from the thermometers, then a suitable temperature transfer medium must be added to the well to properly conduct the temperature to the thermometer bulb. A mixture of graphite and oil, heat transfer paste, or even a light oil will suffice. Union Bushing (Hub) Connection Remove the union bushing from the thermometer if supplied with it. Install this union bushing in the pipeline or service as required. Insert the stem of the thermometer through the union bushing hole, engaging stem coupling nut with union bushing threads. Position thermometer for best reading position and tighten down coupling nut. 4 Tel: 1-800-WINTERS / www.winters.com

Liquid-in-glass Thermometers Liquid-in-glass Separation All liquid-in-glass thermometers are subject to separation of the liquid column. When this occurs, the thermometer will not read correctly. Some ranges and types are more readily susceptible to separation than others. Causes of Separation 1. Rough handling in shipment causes most separations. If the thermometer is given a sudden jar, the weight of the liquid column in the bore has sufficient inertia to separate the column. 2. If the thermometer with an expansion chamber at the top of the tube (away from the bulb) is accidentally overheated, some of the liquid is driven into the expansion chamber. As the thermometer later cools, the liquid column recedes towards the bulb. If the thermometer is left in a horizontal or inverted position while cooling, part of the liquid will remain in the expansion chamber. This would cause separation of the liquid column. How to Re-unite Separated Liquid Column When the reservoir or expansion chamber is at top of the tube (away from the bulb) / ranges below 550 F Heat the bulb of the thermometer slowly, observing the rise of the liquid in the tube. The point of separation should be driven into the expansion chamber. Take care that the chamber never becomes completely filled or the internal pressure will cause the tube to break. After the separation enters the expansion chamber, put the thermometer in an upright position. Give the tube a slight jar so that the particles of entrapped gas will rise above the liquid. When the liquid recedes, the column will be joined. When there is no reservoir at the top of the tube / ranges above 550 F Put the thermometer bulb in dry ice, so as to draw all the liquid into the tube. Tap the bulb gently on a hard surface with the thermometer held in an upright position, bringing the liquid together. When gradual heat is applied and the liquid rises, the column will be joined. Scale Rotation Grasp connection end firmly. Rotate locking nut by hand. Vari-angle Adjustment A A Loosen single screw (A). Tilt to desired angle. Tighten screw (A) to secure the angle. Tel: 1-800-WINTERS / www.winters.com 5

Remote Reading Thermometers Remote Reading Thermometers Remote reading thermometers are instruments used to measure temperature from a remote source. By means of a capillary tube with a sensing probe at one end and an indicating dial on the other, temperatures can be determined from a source that is up to 30 (100 m) away. Remote reading thermometers are filled with either gas or vapour depending on the specification. As temperature changes, the gas or vapour expands/contracts, creating pressure that is measured by a bourdon tube. Installation of Remote Reading Thermometers Accuracy The thermometer will read only the temperature in which the sensitive bulb is immersed. It is important to place at least 2 ½ of the sensitive bulb in the media to ensure reading accuracy. 2 ½ minimum immersion Corrosion The use of separate sockets of special material is recommended for corrosive or highly abrasive service. Capillaries are available in copper braided and stainless steel (with or without flexible armor), in an assortment of lengths. Winters recommends using a stainless steel bulb and capillary for all process temperatures above 500 F (260 C). Location These thermometers offer the advantage of taking temperature readings away from locations that have heavy vibration or are possibly dangerous. Each thermometer with a front or back flange will have three mounting holes for securing the thermometer to a panel. Alternatively, u-clamps are available. Thermowell Connection Remove the thermowell from the thermometer if supplied with it. Install this thermowell in the pipeline or service as required. Insert the stem of the thermometer through the thermowell. Position thermometer for best reading position and tighten down. If the thermowells are purchased separately from the thermometers, then a suitable temperature transfer medium must be added to the well to properly conduct the temperature to the thermometer bulb. A mixture of graphite and oil, heat transfer paste, or even a light oil will suffice. Union Bushing (Hub) Connection Remove the union bushing from the thermometer if supplied with it. Install this union bushing in the pipeline or service as required. Insert the stem of the thermometer through the union bushing hole, engaging stem coupling nut with union bushing threads. Position thermometer for best reading position and tighten down coupling nut. 6 Tel: 1-800-WINTERS / www.winters.com

10 Remote Reading Thermometers Gas-filled Thermometers Gas-filled thermometers are designed for industrial applications requiring accurate and uniform response over the entire range. The entire system is filled under pressure with inert gas for positive movement, accuracy and sensitivity. The accuracy delivered by this system is +/-0.5% of the full scale value. We recommend the operating temperature range fall in the upper half of the dial. 40 50 60 Optimal operating temperature range 20 30 80 100 120 140 160 70 60 180 80 0-7 40 20 www.winters.com 200 220 F C 100 90 Vapour-filled Thermometers Vapour-filled thermometers have non-linear scales (non-equal graduations across the entire scale). To ensure exceptionally close readings, the operating temperature should fall in the 2 /3 of the scale. The accuracy delivered by this system is +/-2% of the full scale value. Optimal operating temperature range 30 50 70 60 150 120 80 20 0 80 180 220 F 200 90 C 100 www.winters.com 7 Tel: 1-800-WINTERS / www.winters.com

MANUFACTURER OF INDUSTRIAL INSTRUMENTATION operates globally and is distributed in over 80 countries. Please contact us for your nearest Regional Manager. Corporate 121 Railside Road Toronto,Ontario M3A 1B2 Tel: 416-444-2345 Fax: 416-444-8979 1-800-WINTERS sales@winters.com USA - Buffalo 600 Ensminger Road Buffalo, New York 14150 Tel: 716-874-8700 Fax: 716-874-8800 1-800-WINTERS usasales@winters.com Canada - Calgary 8-2807 107th Ave. SE Calgary, Alberta T2Z 4M2 Tel: 403-723-6645 Fax: 403-723-6647 1-800-WINTERS calgary@winters.com USA - Houston 11050 West Little York Road Building B-7 Houston, Texas 77041 Tel: 713-983-8607 Fax: 713-983-8608 usasales@winters.com Asia Shanghai WitHub Hi-Tech Business Center Suite 103-109 No. 333 Hongqiao Road Shanghai 200030 China Tel: 86-21-6104-2610 Fax: 86-21-6104-2615 asiasales@winters.com Latin America Albarellos 1916 1 O Piso E3, E4, E5 B1640BIN, Martinez Buenos Aires, Argentina Tel: 54-11-4733-3003 Fax: 54-11-4733-0572 latinsales@winters.com www.winters.com.ar Distributed by: Download Winters literature at www.winters.com is ISO 9001:2008 Registered 05/11