79 GAUGE / THERMOMETER H N O

Size: px
Start display at page:

Download "79 GAUGE / THERMOMETER H N O"

Transcription

1 79 GAUGE / TERMMETER

2 plastic-housing 80 A D 40 Centre back entry and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B D 50 Centre back entry and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: adjustable red mark pointer, adjustable red mark pointer with green sector, TEFL-ring fixed on parallell thread (up to 25 bar) bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 63 Centre back entry and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: adjustable red mark pointer, adjustable red mark pointer with green sector, TEFL-ring fixed on parallell thread (up to 25 bar) bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 100

3 s plastic-housing D 80 Centre back entry and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: adjustable red mark pointer, adjustable red mark pointer with green sector bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B Square 40x40 Centre back entry non panel mount and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 14 mm flats. Pressure element: bourdon tube Cualloy, C-type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP54 per E / IEC bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B Square 48x48 Panel mount, centre back entry and are not aggressive to copper alloys. Design: E Case with clips: Black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cualloy, C-type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP30 per E / IEC bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 100

4 plastic-housing 82 A D 40 Bottom entry and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white aluminium. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 12 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: adjustable red mark pointer bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B D 50 Bottom entry and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white aluminium. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.:ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: adjustable red mark pointer, adjustable red mark pointer with green sector bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 63 Bottom entry and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white aluminium. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: adjustable red mark pointer, adjustable red mark pointer with green sector bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 100

5 plastic-housing D 80 Bottom entry and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white aluminium. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: adjustable red mark pointer, adjustable red mark pointer with green sector bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 100 Bottom entry and are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white aluminium. Window: clear plastic. Pressure connection: copper alloy, G 1/2 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: adjustable red mark pointer, adjustable red mark pointer with green sector bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B 30 83

6 plastic-housing 84 A D 40 Panel mount, centre back entry and are not aggressive to copper alloys. Design: E Case + Fixing ring: Black plastic. Triangular bezel ring: Chrome plated plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 14 mm flats. Pressure element: bourdon tube Cualloy, C-type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP54 per E / IEC 529. ptional extras: black plastic 3-hole flange bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B D 50 Panel mount, centre back entry and are not aggressive to copper alloys. Design: E Case + Fixing ring: Black plastic. Triangular bezel ring: Chrome plated plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cualloy, C-type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP54 per E / IEC 529. ptional extras: black plastic 3-hole flange bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 63 Panel mount, centre back entry and are not aggressive to copper alloys. Design: E Case + Fixing ring: Black plastic. Triangular bezel ring: Chrome plated plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cualloy, C-type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP54 per E / IEC 529. ptional extras: black plastic 3-hole flange bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 72

7 plastic-housing D 40 Panel mount, centre back entry and are not aggressive to copper alloys. Design: E Case: black plastic. 3-hole front flange: Chrome plated plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, C-type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP54 per E / IEC 529. ptional extras: black plastic triangular bezel bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B D 50 Panel mount, centre back entry and are not aggressive to copper alloys. Design: E Case: black plastic. 3-hole front flange: Chrome plated plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, C-type, soft soldered. perating temp.: ambient: C. Medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP54 per E / IEC 529. ptional extras: black plastic triangular bezel bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 63 Panel mount, centre back entry and are not aggressive to copper alloys. Design: E Case: black plastic. 3-hole front flange: Chrome plated plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, C-type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP54 per E / IEC 529. ptional extras: black plastic triangular bezel bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 72

8 plastic-housing 86 A D 40 Panel mount, centre back entry and are not aggressive to copper alloys. Design: E Case with clips: Black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, C-type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP30 per E / IEC bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B 50 tyre-inflation pressure gauge D 63 Centre back entry Pressure gauge for gaseous media which are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cualloy, C-type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl Degree of protection: IP31 per E / IEC bar / psi G 1/4 B D 80 Centre back entry Pressure gauge for gaseous media which are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cualloy, C-type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl Degree of protection: IP31 per E / IEC bar / psi G 1/4 B D 63 Bottom entry Pressure gauge for gaseous media which are not aggressive to copper alloys. Design: E Case: black plastic. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, C-type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / polyester combination. Accuracy class: cl Degree of protection: IP31 per E / IEC bar / psi G 1/4 B 100

9 steel-housing D 40 Centre back entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 12 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: 3-hole front flange steel chrome-plated, triangular bezel ring steel chromeplated + U-clamp with zinc-plated housing bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B D 50 Centre back entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: 3-hole front flange steel chrome-plated, triangular bezel ring steel chrome-plated + U-clamp with zincplated housing bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 63 Centre back entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: 3-hole front flange steel chrome-plated, triangular bezel ring steel chrome-plated + U-clamp with zincplated housing bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B

10 steel-housing 88 A D 80 Centre back entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/2 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: 3-hole front flange steel chrome-plated, triangular bezel ring steel chrome-plated + U-clamp with zincplated housing bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B D 100 Centre back entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/2 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: 3-hole front flange steel chrome-plated, triangular bezel ring steel chrome-plated + U-clamp with zincplated housing bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B 30

11 steel-housing D 40 Bottom entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 12 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: stainless steel bezel ring bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B D 50 Bottom entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: stainless steel bezel ring bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 63 Bottom entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: stainless steel bezel ring bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 100

12 steel-housing 90 A D 80 Bottom entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/2 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: stainless steel bezel ring bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B D 100 Bottom entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/2 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC 529. ptional extras: stainless steel bezel ring bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B 30

13 stainless steel-housing D 40 Centre back entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 12 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B D 50 Centre back entry and are not aggressive to copper alloys. Design: E Case: Steel black. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 100

14 stainless steel-housing 92 A D 40 Bottom entry and are not aggressive to copper alloys. Design: E Case: Stainles steel. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/8 B, 12 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B D 50 Bottom entry and are not aggressive to copper alloys. Design: E Case: Stainles steel. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2.5, cl. 1.6 on request. Degree of protection: IP31 per E / IEC bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 100

15 plastic-housing glycerine filled D 40 Centre back entry and are not aggressive to copper alloys. For measuring points subject to vibrations and high dynamic pressure loads. Design: E Case: ABS black, with blow out, ranges < 16 bar with case venting. Dial: white plastic. Window: PMMA, ultra-sonic welded. Pressure connection: copper alloy, G 1/8 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Liquid filling: Glycerine 86.5%. Accuracy class: cl Degree of protection: IP65 per E / IEC bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B bar / psi G 1/8 B D 50 Centre back entry and are not aggressive to copper alloys. For measuring points subject to vibrations and high dynamic pressure loads. Design: E Case: ABS black, with blow out, ranges < 16 bar with case venting. Dial: white plastic. Window: PMMA, ultra-sonic welded. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Liquid filling: Glycerine 86.5%. Accuracy class: cl Degree of protection: IP65 per E / IEC 529. ptional extras: U-clamp, zinc-plated steel for panel mounting bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 50

16 plastic-housing glycerine filled 94 A D 63 Centre back entry and are not aggressive to copper alloys. For measuring points subject to vibrations and high dynamic pressure loads. Design: E Case: ABS black, with blow out, ranges < 16 bar with case venting. Dial: white plastic. Window: PMMA, ultra-sonic welded. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Liquid filling: Glycerine 86.5%. Accuracy class: cl Degree of protection: IP65 per E / IEC 529. ptional extras: U-clamp, zinc-plated steel for panel mounting, black plastic 3-hole flange bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 63 Bottom entry and are not aggressive to copper alloys. For measuring points subject to vibrations and high dynamic pressure loads. Design: E Case: ABS black, with blow out, ranges < 16 bar with case venting. Dial: white plastic. Window: PMMA, ultra-sonic welded. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Liquid filling: Glycerine 86.5%. Accuracy class: cl Degree of protection: IP65 per E / IEC bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B 100

17 plastic-housing glycerine filled D 63 Centre back entry and are not aggressive to copper alloys. For measuring points subject to vibrations and high dynamic pressure loads. Design: E Case + roll on bezel: Stainless steel, with blow out, ranges < 16 bar with case venting. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Liquid filling: Glycerine 86.5%. Accuracy class: cl Degree of protection: IP65 per E / IEC 529. ptional extras: U-clamp, zinc-plated steel for panel mounting, 3-hole front flange, stainless steel bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 100 Centre back entry and are not aggressive to copper alloys. For measuring points subject to vibrations and high dynamic pressure loads. Design: E Case + roll on bezel: Stainless steel, with blow out, ranges < 16 bar with case venting. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/2 B, 14 mm flats. Pressure element: bourdon tube Cualloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C Medium: +60 C max. Movement: Cu-alloy. Liquid filling: Glycerine 86.5%. Accuracy class: cl Degree of protection: IP65 per E / IEC 529. ptional extras: U-clamp, zinc-plated steel for panel mounting, 3-hole front flange, stainless steel bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B 12

18 stainless steel-housing glycerine filled 96 A D 63 Bottom entry and are not aggressive to copper alloys. For measuring points subject to vibrations and high dynamic pressure loads. Design: E Case + roll on bezel: Stainless steel, with blow out, ranges < 16 bar with case venting. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: bourdon tube Cualloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C Medium: +60 C max. Movement: Cu-alloy. Liquid filling: Glycerine 86.5%. Accuracy class: cl Degree of protection: IP65 per E / IEC bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B bar / psi G 1/4 B D 100 Bottom entry and are not aggressive to copper alloys. For measuring points subject to vibrations and high dynamic pressure loads. Design: E Case + roll on bezel: Stainless steel, with blow out, ranges < 16 bar with case venting. Dial: white plastic. Window: clear plastic. Pressure connection: copper alloy, G 1/2 B, 14 mm flats. Pressure element: bourdon tube Cualloy, < 60 bar C-type, > 60 bar helical type, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C Medium: +60 C max. Movement: Cu-alloy. Liquid filling: Glycerine 86.5%. Accuracy class: cl Degree of protection: IP65 per E / IEC bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B bar / psi G 1/2 B 30

19 steel-housing D 63 Bottom entry Low pressure (capsule) gauge for gaseous, dry media which are not aggressive to copper alloys. Design: E Case: Steel black. Dial: Aluminium white. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: Capsule Cu-alloy, -ring Perbunan. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl Degree of protection: IP32 per E / IEC mbar / mm2 G 1/4 B mbar / mm2 G 1/4 B mbar / mm2 G 1/4 B mbar / mm2 G 1/4 B mbar / mm2 G 1/4 B D 80 Bottom entry Low pressure (capsule) gauge for gaseous, dry media which are not aggressive to copper alloys. Design: E Case: Steel black. Dial: Aluminium white. Window: clear plastic. Pressure connection: copper alloy, G 1/4 B, 14 mm flats. Pressure element: Capsule Cu-alloy, -ring Perbunan. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl Degree of protection: IP32 per E / IEC mbar / mm2 G 1/4 B mbar / mm2 G 1/4 B mbar / mm2 G 1/4 B mbar / mm2 G 1/4 B mbar / mm2 G 1/4 B D 100 Bottom entry Low pressure (capsule) gauge for gaseous, dry media which are not aggressive to copper alloys. Design: E Case: Steel black. Dial: Aluminium white. Window: clear plastic. Pressure connection: copper alloy, G 1/2 B, 22 mm flats. Pressure element: Capsule Cu-alloy, -ring Perbunan. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: Cu-alloy. Accuracy class: cl. 2,5. Degree of protection: IP32 per E / IEC mbar / mm2 G 1/2 B mbar / mm2 G 1/2 B mbar / mm2 G 1/2 B mbar / mm2 G 1/2 B mbar / mm2 G 1/2 B 12

20 miniature gauge 98 A D 23 Centre back entry Miniature pressure gauge for gaseous and liquid media which are not highly viscous, do not crystallize and are not aggressive to copper alloys. Case/connection: copper alloy, in onepiece. Dial: white plastic. Window: clear plastic. Pressure connection: G 1/8 B, 23 mm flats. Pressure element: bourdon tube Cu-alloy, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / plastic combination. Accuracy class: cl Degree of protection: IP54 per E / IEC bar G 1/8 B bar G 1/8 B bar G 1/8 B bar G 1/8 B bar G 1/8 B D 23 Centre back entry Miniature pressure gauge for gaseous and liquid media which are not highly viscous, do not crystallize and are not aggressive to copper alloys. Case/connection: Black plastic, in onepiece. Dial: white plastic. Window: clear plastic. Pressure connection: G 1/8 B, 14 mm flats. Pressure element: bourdon tube Cu-alloy, soft soldered. Working pressure: steady: 75 % of full scale value, fluctuating: 60 % of full scale value. perating temp.: ambient: C, medium: +60 C max. Movement: cu-alloy / plastic combination. Accuracy class: cl Degree of protection: IP54 per E / IEC bar G 1/8 B bar G 1/8 B bar G 1/8 B bar G 1/8 B bar G 1/8 B 100 plastic-housing thermogauge D 80 Centre back entry Pressure gauge for gaseos and liquid media which are not highly viscous, do not crystallize and are not aggressive to copper alloys. Case: black plastic. Dial: white plastic with red adjustable pointer. Window: clear plastic. Connection: copper alloy, automatic valve G 1/2 B supplied together. Pressure element: bourdon tube Cu-alloy, C-type, soft soldered. Temp. element: bimetal spiral. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5 (Pressure), cl. 2 (Temperature). Degree of protection: IP31 per E / IEC ,5 bar / 0-120º C G 1/2 B bar / 0-120º C G 1/2 B bar / 0-120º C G 1/2 B D 80 Bottom entry Pressure gauge for gaseos and liquid media which are not highly viscous, do not crystallize and are not aggressive to copper alloys. Case: black plastic. Dial: white plastic with red adjustable pointer. Window: clear plastic. Connection: copper alloy, automatic valve G 1/2 B supplied together. Pressure element: bourdon tube Cu-alloy, C-type, soft soldered. Temp. element: bimetal spiral. Movement: cu-alloy / polyester combination. Accuracy class: cl. 2.5 (Pressure), cl. 2 (Temperature). Degree of protection: IP31 per E / IEC ,5 bar / 0-120º C G 1/2 B bar / 0-120º C G 1/2 B bar / 0-120º C G 1/2 B 50

21 accessories U-clamp for panel mounting S inox 63 U-clamp for panel mounting. For stainless steel case D 63, glycerine-filled pressure gauge, back entry. Body: zinc-plated steel. 99 Article number Unit U-clamp for panel mounting S abs 50 U-clamp for panel mounting. For plastic case D 50, glycerine-filled pressure gauge, back entry. Body: zinc-plated steel. Article number Unit U-clamp for panel mounting S abs 63 U-clamp for panel mounting. For plastic case D 63, glycerine-filled pressure gauge, back entry. Body: zinc-plated steel. Article number Unit holes flange for panel mounting F abs 63 3-holes flange for panel mounting. For plastic case D 63, glycerine-filled pressure gauge, back entry. Body: black plastic. Article number Unit

22 thermometer bimetal thermometer 100 A D 33 Back entry Thermometer complete with brass pocket, back entry with chrome-plated ring for heating systems. Case: zinc-plated steel. Ring: chrome-plated steel. Window: plastic up to scale 120º C, above glass. Stem: centre back entry, zinc-plated steel. Accuracy class: cl. 2. Therm. element: bimetal spiral. Pocket: brass. Degree of protection: IP31. Article number Stem Scale Range Connection Unit º C G 3/8 B º C G 3/8 B º C G 3/8 B º C G 1/2 B º C G 1/2 B º C G 1/2 B º C G 1/2 B D 40 Back entry Thermometer complete with brass pocket, back entry with chrome-plated ring for heating systems. Case: zinc-plated steel. Ring: chrome-plated steel. Window: plastic up to scale 120º C, above glass. Stem: centre back entry, zinc-plated steel. Accuracy class: cl. 2. Therm. element: bimetal spiral. Pocket: brass. Degree of protection: IP31. Article number Stem Scale Range Connection Unit º C G 3/8 B º C G 3/8 B º C G 1/2 B º C G 1/2 B º C G 1/2 B º C G 1/2 B D 40 Back entry Europe version Thermometer complete with brass pocket, back entry without chrome-plated ring for heating systems. Case: zinc-plated steel. Window: plastic. Stem: centre back entry, zinc-plated steel. Accuracy class: cl. 2. Therm.element: bimetal spiral. Pocket: brass. Degree of protection: IP31. Article number Stem Scale Range Connection Unit º C G 3/8 B E º C G 3/8 B E º C G 1/2 B E º C G 1/2 B E º C G 1/2 B E º C G 1/2 B D 52 Back entry Thermometer complete with brass pocket, back entry with chrome-plated ring. Case: zinc-plated steel. Ring: chrome-plated steel. Window: plastic up to scale 120º C, above glass. Stem: centre back entry, zinc-plated steel. Accuracy class: cl. 2. Therm.element: bimetal spiral. Pocket: brass. Degree of protection: IP31. Article number Stem Scale Range Connection Unit º C G 1/2 B º C G 1/2 B º C G 1/2 B º C G 1/2 B º C G 1/2 B º C G 1/2 B º C G 1/2 B º C G 1/2 B º C G 1/2 B º C G 1/2 B 100

Many Products...One Source

Many Products...One Source PRESSURE GAUGES Dedicated Sales Rep for Your Area 97%Fill Rate Shipping within 24 Hours State of the Art Warehouse System Technical Support Quality Control Program 25 Whaley Avenue Milverton, Ontario N0K

More information

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

Commercial / HVAC / Plumbing. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories Commercial / HVAC / Plumbing Specification Guide For Pressure & Temperature Instruments & Related Accessories Prepared for Consultant, Design & Specification Engineers Gauges Contractor Gauge (PCT, PCT-LF)

More information

SOLFRUNT Pressure Gauges and Other Products for the Process Industries

SOLFRUNT Pressure Gauges and Other Products for the Process Industries A1 SOLFRUNT Pressure Gauges and Other Products for the Process Industries AMETEK s line of high quality process gauges are specifically designed to meet the demanding needs of the chemical and petroleum

More information

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD

HVAC/R GAS TEST GAUGES SPECIFICATIONS ACCURACY CASE SIZES CASE MATERIAL MOUNTING STYLE HOUSING MATERIAL TUBE & SOCKET MOVEMENT RANGES DIAL STANDARD HVAC/R GAS TEST GAUGE Hex or Bell Type mounting 5 to00 Psi pressure ranges Steel case and brass internals Use to pressure test all new gas installations for leaks and passing inspection codes. After installing

More information

Thermometer in stainless steel with capillary and switch contacts

Thermometer in stainless steel with capillary and switch contacts Design Type Case diameter Thermometer in and switch contacts 7308 = back flange for wall mounting 7312 = front flange for panel mounting 7310 = mounting bracket for wall mounting Dim 100 mm or 160 mm Accuracy

More information

Bimetal thermometer Model 52, industrial series

Bimetal thermometer Model 52, industrial series Mechanical temperature measurement Bimetal thermometer Model 52, industrial series WIKA data sheet TM 52.01 for further approvals see page 6 Applications A wide range of applications in machine building,

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS

T R A N S F O R M E R A C C E S S O R I E S SAM THERMOMETERS THERMOMETERS BIMETA THERMOMETERS (DIN 1 1 - PART 2) TYPE: MBT 7 2 4 8 1 12 C APPICATION This thermometer is designed for indication of oil temperature in both transformers with epansion conservator or

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE

THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE THERMOMETER INSTALLATION, OPERATION AND MAINTENANCE www.winters.com MANUFACTURER OF INDUSTRIAL INSTRUMENTATION Bi-Metal Thermometers Bi-Metal Thermometers Winters bi-metal thermometers are direct sensing

More information

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version Mechatronic pressure measurement Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version k Applications for further approvals see page 14 WIKA data sheet PV 22.02 Control

More information

Item Number Description Type of Gauge Size in " Price

Item Number Description Type of Gauge Size in  Price FARIA Euro Perimeter lighted black dial with bold white graphics, black aluminum bezel, contoured white pointer and flat fog resistant lens EURO Item Number Description Type of Gauge Size in " Price 32805

More information

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION 220519 - THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES ARCHITECTURE, ENGINEERING AND CONSTRUCTION P00000000 0000 DOCUMENTS ARCHITECTURE & ENGINEERING 326 East Hoover, Mail Stop B Ann Arbor, MI 48109-1002 Phone: 734-764-3414 Fax: 734-936-3334 SPECIFICATION

More information

Self-operated Temperature Regulators Temperature Regulator Type 1u

Self-operated Temperature Regulators Temperature Regulator Type 1u Self-operated Temperature Regulators Temperature Regulator Type u Application Temperature regulators for cooling installations Control thermostats for set points ) from 0 to 250 C G ½ to G or DN 5 to 50

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

CONEC SnapLock. 1 Introduction

CONEC SnapLock. 1 Introduction CONEC SnapLock E L E C T R O N I C C O N N E C T O R S 1 Introduction The new CONEC SnapLock locking system consists of D-SUB connectors and D-SUB hoods allowing quick and safe locking without any additional

More information

Furniture Fittings Furniture Handles and Knobs

Furniture Fittings Furniture Handles and Knobs Handle profile - Aluminium 21 mm 1.5 mm 2,500 mm 126.21.02 30 mm 126.22.0 11.5 mm 1.5 mm 2,500 mm 126.20.05 AH.4 Dim. A Dim. B Length Usable length Cat. No. 34.5 mm 8.5 mm 2,500 mm 2,460 mm 126.15.00 Dim.

More information

VDL 53 - Vacuum drying oven for flammable solvents

VDL 53 - Vacuum drying oven for flammable solvents Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

FLASH TANK ECONOMIZER PRODUCT GUIDE

FLASH TANK ECONOMIZER PRODUCT GUIDE FLASH TANK ECONOMIZER PRODUCT GUIDE Overview A flash tank is used to recover blowdown energy in the form of flash steam and blowdown. This can only be used with a deaerator or some other pressurized device.

More information

Switches SWITCHES SWITCHES

Switches SWITCHES SWITCHES Switches Manufactured from Stainless Steel, Bulgin s extensive range of vandal resistant security switches are designed with a high resistance to wear and tear, corrosion and harsh use in potentially hostile

More information

Solenoid valves Type EVU

Solenoid valves Type EVU Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot

More information

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building.

HMI Components. Series. Indicator Pushbutton Illuminated pushbutton. Machinery and Automation Building technology Panel building. Edition 02/2016 HMI s Series Characteristics The compact Series is especially suited for: Functions The Series incorporates the following functions: Market segments The EAO series is used in the following

More information

Compact pressure switch Flameproof enclosure Ex d Model PCA

Compact pressure switch Flameproof enclosure Ex d Model PCA Mechatronic pressure measurement Compact pressure switch Flameproof enclosure Ex d Model PCA WIKA data sheet PV 33.31 for further approvals see page 4 Process Compact Series Applications Pressure monitoring

More information

Mini USB and USB 2.0-IP67 Connector System

Mini USB and USB 2.0-IP67 Connector System Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

Boilers Compressors Chillers Pipe Systems. HVAC & Refrigeration Applications Pressure and Temperature Measurement

Boilers Compressors Chillers Pipe Systems. HVAC & Refrigeration Applications Pressure and Temperature Measurement Boilers Compressors Chillers Pipe Systems HVAC & Refrigeration Applications Pressure and Temperature Measurement R Mechanical Pressure Refrigeration Gauge WIKA s type 111.11RF 2½ gauges, which have an

More information

BRICK LED Design Ronni Gol

BRICK LED Design Ronni Gol OUTDOOR2014 BRICK LED Design Ronni Gol BRICK LED Design Ronni Gol 120mm 180 mm 60mm BRICK LED White 256300 Silver 256301 Black 256302 6W LED warm white IP54 1.596,00 ex. VAT / 1.995,00 incl. VAT 2.073,00

More information

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below: Needle Valves : - Needle valves have a slender, tapered point at the end of the valve stem that is lowered through the seat to restrict or block flow. Fluid flowing through the Needle valve turns 90 degrees

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

Accu-Switch Instruction Booklet The Direct Drive Difference in Switch Gauges

Accu-Switch Instruction Booklet The Direct Drive Difference in Switch Gauges Accu-Switch Instruction Booklet The Direct Drive Difference in Switch Gauges INTRODUCTION The Accu-Switch series of pressure Switch Gauges from 3D Instruments offers a new standard for a mechanical pressure

More information

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F Self-operated Temperature Regulators Type 1 to Type 9 PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F Edition April 2012 Information Sheet T 2010 EN Self-operated

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial

Pressure Gage and Swichgage Instruments OPL Series 4-1/2 in. (114mm) Diameter Dial sect. 05 9600 rev. 206/08/0 Pressure Gage and Swichgage Instruments OPL Series 4-/2 in. (4mm) Diameter Dial The OPL-series pressure Swichgage instruments are combination pressure indicating gages with

More information

Fixtures - Parts - Accessories to shampoo bowls

Fixtures - Parts - Accessories to shampoo bowls Page 1??? - For what brand of bowl do you need parts??? Find out by looking on the bottom of the bowl, between the front and strainer, where molded in the bottom is the brand and model number. For example,

More information

REGULATORS 175/153 Series

REGULATORS 175/153 Series 175/153 Series 175 HEATING 153 COOLING Watson McDaniel reserves the right to change the designs and/or materials of its products without notice. 2002 Watson McDaniel Company Revised 7/2002 175 / 153 Screwed

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter

Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Ed.15.01 Design Diaphragm Seal with flush diaphragm and flange acc.to SMS. Completed with pressure gauge in stainless steel, liquid filled or pressure transmitter Standard 4026/60H Pressure rate PN 40

More information

Linkeo 19" freestanding cabinets

Linkeo 19 freestanding cabinets 87045 LIMOGES Cedex France Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Linkeo 19" freestanding cabinets Page 1. General characteristics....1 2. Range....2 3. Technical characteristics...3

More information

2.12. page 223 2.12. Products for Explosion hazardous Environment

2.12. page 223 2.12. Products for Explosion hazardous Environment 2.12 page 223 2.12 Products for Explosion hazardous Environment Non-electric valves for explosion 2.12.1 page 224 hazardous environment The following manually and mechanically actuated valves are available

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Variable V Area Flowmeter Rotameter The Original

Variable V Area Flowmeter Rotameter The Original Variable V Area Flowmeter Rotameter The Original 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com precise measurement of liquids

More information

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

AIR-AIR PRESSURE MULTIPLIER (BOOSTER) AIR-AIR PRESSURE MULTIPLIER (BOOSTER) The air-air pressure multiplier, or booster, is an automatic device that compresses air to give an outlet pressure that is double the inlet pressure. It is normally

More information

Cylinders Series 40. Double acting, cushioned, magnetic ø160-200 - 250 (DIN/ISO 6431)

Cylinders Series 40. Double acting, cushioned, magnetic ø160-200 - 250 (DIN/ISO 6431) Cylinders Series 40 Double acting, cushioned, magnetic ø60-200 - 250 (DIN/ISO 643)»»» DIN/ISO 643 VDMA 24562 Rolled stainless steel rod Adjustable cushioning The cylinders Series 40 with diameters 60,

More information

WIKA INSTRUMENT CORPORATION

WIKA INSTRUMENT CORPORATION WIKA INSTRUMENT CORPORATION Instruction Manual GAUGE PRESSURE INDICATOR Series 1500 Series 1000 Series 300 WIKA Instrument Corporation 1000 Wiegand Boulevard Lawrenceville, GA 30043 1-888-945-2872 http://www.wika.com

More information

2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

2010-2011. Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches. 2010-2011 Solutions for appliance & electronic applications Shortform Catalogue rocker lever push vandal resistant slide door snap-action & safety rotary IEC sockets fuseholders indicators A trading name

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

HARTING Ethernet Cabling 8-poles Overview

HARTING Ethernet Cabling 8-poles Overview Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs

More information

ODU MEDI-SNAP. Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal. www.odu.de

ODU MEDI-SNAP. Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal. www.odu.de Miniature Circular Connectors with Push-Pull Locking Made of Plastic or Metal Miniature Circular Connectors with Push-Pull Locking for Medical Applications Applications Medical Test and measure equipment

More information

Table of Contents. Product Catalog > Table of Contents

Table of Contents. Product Catalog > Table of Contents Product Catalog > Table of Contents Table of Contents Selecting a Pressure Gauge 2 Chemical Compatibility Table 3 Advantages of Liquid-filled Gauges 4 WIKA Type Numbers 5 Ordering Guidelines for Pressure

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Thermostatic element RAVV for 2-way valves

Thermostatic element RAVV for 2-way valves Description / Application RAVV is a self-acting thermostatic element which can be combined with 2-way valve bodies RAV-/8, VMT-/8 or VMA 15. RAVV is used to control temperatures in small hot water cylinders

More information

167D Series Switching Valves

167D Series Switching Valves June 2011 167D Series Switching Valves P1185 P1184 167D TWO-WAY SWITCHING VALVE 167DA THREE-WAY SWITCHING VALVE Figure 1. 167D Series Switching Valves Introduction The 167D Series switching valves are

More information

Thermostatic valve Type AVTA

Thermostatic valve Type AVTA MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic valve Type AVTA Thermostatic valves are used for proportional regulation of flow quantity, depending on the setting and the sensor temperature. The

More information

Single sub-base valve

Single sub-base valve solenoid valves Mini-valves 10 mm Electrical connection... Mounting... Port sizes... Rated temperature... Fluid... Working pressure... Nominal flow... Pneumatic connections Voltage... Power... NC poppet

More information

ATL Fuel Level Sender Probes

ATL Fuel Level Sender Probes T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of

More information

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:

5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose: PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404 /, 8403, 8405, 8404 > Fast comparison of measured with set values > s available, 8403 and 8402 www.stahl.de, 8403, 8405, 8404 10073E00 The ammeters and voltmeters from R. STAHL are explosion protected,

More information

Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve

Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve Type 3510-1 and Type 3510-7 Pneumatic Control Valves Type 3510 Micro-flow Valve ANSI version Application Control valve especially designed for controlling low flow rates in pilot plants and technical research

More information

Catalog 900. Product Catalog. Pressure and Temperature Measurement. Mechanical Pressure Diaphragm Seals Mechanical Temperature Accessories

Catalog 900. Product Catalog. Pressure and Temperature Measurement. Mechanical Pressure Diaphragm Seals Mechanical Temperature Accessories Catalog 900 Product Catalog Pressure and Temperature Measurement Mechanical Pressure Diaphragm Seals Mechanical Temperature Accessories R Product Catalog 900 Pressure and Temperature Measurement Product

More information

OEM-EP Pressure Controllers

OEM-EP Pressure Controllers Pressure Controllers Typical Applications Carrier Gas Pressure Control Air over Liquid Control Mass Spectrometer Process Gas Supply Pressure Control Miniature ler The Miniature ler converts a variable

More information

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) Description RAVV can be combined with 2-way valves RAV- /8, VMT-/8 or VMA 15. Controller closes on rising temperature. There is a special

More information

PAM Connectors. PAM Bayonet Connectors

PAM Connectors. PAM Bayonet Connectors PAM Bayonet Tel : 33 (0)1 60 84 21 40 Fax : 33 (0)1 60 84 43 81 info@bernier.tm.fr www.bernier.tm.fr Overview Miniature audio connectors with bayonet locking system, equipped with 07 or 10 contacts, and

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

ORLANDO srl. M P R 50 025 OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar

ORLANDO srl. M P R 50 025 OPTIMA Radial pressure gauges for swimming-pools 0-2,5 Bar Chiavari (Ge) - Italia Tel.: Italia + 0185 + 38.50.10 Fax: Italia + 0185 + 38.50.11 e-mail: orlando@orlando.it Http://www.orlando.it M R 50...: Radial pressure gauge ø 50 ( available scale in bar: 4, 6,10,12,16

More information

Tubular connection elements

Tubular connection elements KIRÁY TRING KFT H-1151 udapest Mogyoród útja 12 14tel: 061307-3801 Tubular connection elements 429 KIRÁY TRING KFT H-1151 udapest Mogyoród útja 12 14tel: 061307-3801 Technical information on the tubular

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service

More information

Hose Clamps & Fittings

Hose Clamps & Fittings All Stainless Steel Marine or Underground Hose Clamps 5/16 HEX HEAD SCREW 60000 SERIES Highly corrosion resistant Use for marine or underground applications Stainless Steel Band, Housing Plated Steel Screw

More information

Optolite Indicators. General Purpose INDICATOR LIGHTS. Sub-Miniature. Miniature, Neon

Optolite Indicators. General Purpose INDICATOR LIGHTS. Sub-Miniature. Miniature, Neon Sub- Lockwasher, stainless steel or steel, nickel plate. Brass T-1 sub-midget flange base. See Selection Guide. Assembly mounts from front of panel. All mounting hardware Approximately.12 oz. less lamp.,

More information

K17.12 Door closers K17. Doors 01.09.2013

K17.12 Door closers K17. Doors 01.09.2013 K17 Doors K17.12 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com Contents 1. OPTIC door closer TS40(V) with scissor

More information

Instruction Manual Differential Pressure Transmitter

Instruction Manual Differential Pressure Transmitter DE28 Instruction Manual Differential Pressure Transmitter Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Threaded Resistance Thermometers Model TR10-D, Miniature Design Electrical Temperature Measurement Threaded Resistance Thermometers Model TR10-D, Miniature Design WIKA Data Sheet TE 60.04 Applications Machine building, plant and tank construction Power transmission

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Quick response concealed horizontal sidewall sprinkler

Quick response concealed horizontal sidewall sprinkler January 1, 2011 Sprinkler 63a 1. DESCRIPTION Viking Quick Response Concealed Horizontal Sidewall Sprinkler VK408 is a small solder link and lever spray sprinkler designed for installation on concealed

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

K17.11 DOOR BOLTS K17 DOORS 01.09.2013

K17.11 DOOR BOLTS K17 DOORS 01.09.2013 K17 DOORS K17.11 01.09.2013 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. Locking set series 86000...K17.11.03 2.

More information

Tyco PremiAir Pneumatic Actuators

Tyco PremiAir Pneumatic Actuators A comprehensive range of pneumatic actuators, conforming to EN ISO 5211, providing compact, reliable and economical powered operation for all types of quarter turn valves. Features Mounting to valve either

More information

PB accessories. PB accessories. Labelling option. Order Information B4-2728. Printed board handle A BZA42727 BZA42724.

PB accessories. PB accessories. Labelling option. Order Information B4-2728. Printed board handle A BZA42727 BZA42724. Printed board handle A Assembly behind front panels Only use printed board handle in conjunction with printed board retainer A (6087-097) Insertion and extraction function Labelling option B4-2728 Item

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4

More information

HDA -----------------------------------------------------------

HDA ----------------------------------------------------------- ----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS

More information

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013 ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 0 QUALITY 0 YEAR GUARANTEE Exclusively distributed by: Table of contents Panel radiators General / Guarantee Technical data and radiator dimensions

More information

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features Pressure Relief/Sustaining Valve Prioritizing pressure zones Ensuring controlled pipeline fill-up Preventing pipeline emptying Pump overload & cavitation protection Safeguarding pump minimum flow Excessive

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Rusty Walker, Corporate Trainer Hill PHOENIX

Rusty Walker, Corporate Trainer Hill PHOENIX Refrigeration 101 Rusty Walker, Corporate Trainer Hill PHOENIX Compressor Basic Refrigeration Cycle Evaporator Condenser / Receiver Expansion Device Vapor Compression Cycle Cooling by the removal of heat

More information

Ariva Powerful Marketing Displays. Exhibit & Display Solutions

Ariva Powerful Marketing Displays. Exhibit & Display Solutions Ariva Powerful Marketing Displays Exhibit & Display Solutions Banner Displays BRONZE BRONZE XL (see page 3) (see page 3) Retractable banner stand Twist-out feet Black or silver finish Silver retractable

More information

High Pressure Equipment Pressure Vessels and Reactors Index

High Pressure Equipment Pressure Vessels and Reactors Index Pressure Vessels and Reacrs High Pressure Equipment Company designs and manufactures a broad range of pressure vessels and reacrs for both bench-scale and pilot plant applications. We have over 0 standard

More information

Relative and absolute pressure switch type 529

Relative and absolute pressure switch type 529 Relative and absolute pressure switch type 529 Pressure range -1... 0 60 bar The compact type 529 pressure switch is based upon the Huba Control developed unique ceramic technology used for the last 20

More information

HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I.

HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I. FUEL LINE Temperature: -40 C to +125 C continuous service. Tube: Type C (Nitrile). Black. Oil and petrol resistant. Reinforcement: Single ply of synthetic fibre. Cover: Type C2 (NBR/PVC). Black. Fuel,

More information

Capacitive Prox E2K-X

Capacitive Prox E2K-X Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows

More information

Portable digital microprocessor thermometers with interchangeable probes

Portable digital microprocessor thermometers with interchangeable probes JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information