Microsoft Windows Server 2008* (x86 & x64) Dual SCM (ALUA) Installation BKM. Intel Order Number: E37652-004



Similar documents
Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

Windows 2008 Server Installation

1 MAXDATA Modular System Firmware Update

Windows Host Utilities Installation and Setup Guide

Intel ESB2 SATA RAID Setup Guidelines

1 Modular System Dual SCM MPIO Software Installation

Guide to SATA Hard Disks Installation and RAID Configuration

Dell EqualLogic Red Hat Enterprise Linux 6.2 Boot from SAN

Cautions When Using BitLocker Drive Encryption on PRIMERGY

Building Microsoft Windows Server 2012 Clusters on the Dell PowerEdge VRTX

Remote PC Guide Series - Volume 2a

Application Note. Introduction. Instructions

Rebuilding a Show Store RAID with the original drives

Configuring ThinkServer RAID 100 on the TS140 and TS440

Windows Host Utilities 6.0 Installation and Setup Guide

Remote PC Guide Series - Volume 2b

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Configuring Virtual Blades

Guide to SATA Hard Disks Installation and RAID Configuration

Guide to SATA Hard Disks Installation and RAID Configuration

Serial ATA 2 Ports PCI Host

ACP ThinManager Tech Notes ThinManager and PXE Boot

VSS installation and application

VIA / JMicron RAID Installation Guide

Dual-boot Windows 10 alongside Windows 8

Step-by-Step Guide. to configure Open-E DSS V7 Active-Active iscsi Failover on Intel Server Systems R2224GZ4GC4. Software Version: DSS ver. 7.

NovaBACKUP xsp Version 15.0 Upgrade Guide

Configuring ThinkServer RAID 100 on the Lenovo TS130

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

AMD SP5100 Dot Hill SATA RAID Users Manual V100

PS Series Storage Array - Configuration, Operation and Management

Intel RAID Software v6.x (and newer) Upgrade/Installation Procedures

SATA II 4 Port PCI RAID Card RC217 User Manual

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for Hewlett Packard HP-UX

Lotus Foundations Start Getting Started

IBM System x3400 and x3500 servers SATA backup device Not seen when attached to SATA onboard controller port

Guide to SATA Hard Disks Installation and RAID Configuration

Computer Setup User Guide

Emulex OneConnect NIC Teaming and Multiple VLAN Driver and Application Release Notes

Image Backup and Recovery Procedures

Type Message Description Probable Cause Suggested Action. Fan in the system is not functioning or room temperature

requirements the Boot Camp boot camp in into Spotlight. 2. If proceeding. 2 Windows 3 Windows

Installing the Operating System or Hypervisor

Optional Lab: Install, Configure, and Partition a Second Hard Drive in Windows Vista

SGI NAS. Quick Start Guide a

Contents. Hardware Configuration Uninstalling Shortcuts Black...29

Intel Server Raid Controller. RAID Configuration Utility (RCU)

RAID Option Installation

How to Install the VMware ESXi Hypervisor on Physical Hardware

This guide explains how to install an Intel Solid-State Drive (Intel SSD) in a SATA-based desktop or notebook computer.

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

Kingston KC300 Security Toolbox

DriveClone Server. Users Manual

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Format the USB Thumb Drive for Ghost

Microsoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers

VT8237 SATA RAID User Manual

Dual Bay Home Media Store. User Manual

Image Backup and Recovery Procedures

Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering

High Density RocketRAID Rocket EJ220 Device Board Data RAID Installation Guide

Raidtec CS3102 Release Notes

README.TXT

Part A. MSI Live Update 3 (Internet Explorer only)

Guide to SATA Hard Disks Installation and RAID Configuration

RAID installation guide

Configuring HP Elite, EliteBook, and Z220 systems for Intel Smart Response Technology

SBI-7125B-T1 Blade Module RAID Setup Procedure

University of Rochester Sophos SafeGuard Encryption for Windows Support Guide

Serial-ATA IDE Card. Version 1.0

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

Using GIGABYTE Notebook for the First Time

README.TXT

Using EonStor FC-host Storage Systems in VMware Infrastructure 3 and vsphere 4

SATA+Ultra ATA RAID CONTROLLER RC212. User Manual

User Guide for Windows 10

HP ProLiant DL380 G5 High Availability Storage Server

Backing up IMail Server using Altaro Backup FS

How To Synchronize the easystore to the AD

Operating System Installation Guide

Embedded Operating Systems in a Point of Sale Environment. White Paper

PA-5000 Series SSD Storage Options Configuring RAID and Disk Backup

Shutting down / Rebooting Small Business Server 2003 Version 1.00

ATTO ExpressSAS Troubleshooting Guide for Windows

S2A6620 Technical Service Bulletin. Cache Protect Battery Replacement

Back-up Server DOC-OEMSPP-S/2014-BUS-EN-10/12/13

Network Interface Upgrade

ThinkServer RD350 and RD450 Operating System Installation Guide

RAID Manual. Edition. Trademarks V1.0 P/N: CK8-A5-0E

HP ProLiant Cluster for MSA1000 for Small Business Hardware Cabling Scheme Introduction Software and Hardware Requirements...

Install SQL Server 2014 Express Edition

Installation Guide. Wyse C Class Conversion to WES7. Wyse USB Firmware Tool TM Release Issue: PN: L Rev. B

NVIDIA RAID Installation Guide

Getting Started Guide

Serial ATA RAID PCI. User's Manual

How to Restore a Windows System to Bare Metal

System Event Log (SEL) Viewer User Guide

Argon Client Management Services- Frequently Asked Questions (FAQ)

Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

Transcription:

Microsoft Windows Server 2008* (x86 & x64) Dual SCM (ALUA) Installation BKM Intel Order Number: E37652-004

Microsoft Windows Server 2008* Dual SCM Installation Table of Contents Slides 3-5: Upgrading from Single SCM to Dual SCM Slides 6-13: Fresh install in a Dual SCM configuration

UPGRADING FROM SINGLE SCM TO DUAL SCM

Upgrading Existing OS from Single to Dual SCM Before installing the second SCM, perform the following: Update the SAS driver to version 1.27.03 For x86, file needed is Windows2K8_x86_Installation_Disk_1.27.03.zip. For x64, file needed is Windows2K8_x64_Installation_Disk_1.27.03.zip. Load the MPIO driver. Reboot the server and verify that the MPIO driver loaded correctly (see the next slide for screenshots). Make sure no error messages pop-up or yellow bangs appear in the device manager. Shut down the compute module. Update the CMM to the software release that supports Dual SCM. Once the CMM comes back up, wait for all the updates to complete and then insert the second SCM. When the second SCM s firmware update completes, check the event log to ensure the SCM is operational, and then power on the compute module.

Verifying MPIO Driver Installation Device Manager -> Disk drives Device Manager -> System Devices

FRESH INSTALL IN DUAL SCM CONFIGURATION

Drive Creation and Assignment Create Storage Pool -> Virtual Drive and assign to a compute module Note which SCM is assigned as the active path (see the red box in the screenshot on the next slide). Boot the compute module and enter the system BIOS (press F2 during POST) If the active SCM for LUN 0 is SCM #1, place it first in the HDD boot order. Typically, this will show up as ID00 LUN0 (see the screenshot on slide 9). If the active SCM for LUN 0 is SCM #2, place it first in the HDD boot order. Typically, this will show up as ID01 LUN0 (see the screenshot on slide 9). Note: This step is critical as not correctly setting up the BIOS boot order could lead to operating systems not booting.

Virtual Drive Properties Page Showing Affinity/Active SCMs

HDD Ordering Based on Active SCM SCM #2 active SCM for HDD SCM #1 active SCM for HDD

Selecting Operating System Installation HDD from HDD List Begin the normal operating system installation process. During the install, a list of HDDs where the operating system can be installed is presented. This list contains duplicate entries for all Virtual Drives assigned to the compute module (one entry for SCM #1 and one entry for SCM #2). Correctly select the Primary SCM s HDD that was assigned the LUN 0 position during VD creation (see the screenshot on slide 5). All SCM #1 drives are listed first followed by their mirrors from SCM #2 (see the screenshot on slide 5). If a secondary path is chosen by mistake, the following error message will appear at the bottom of the window, which can be corrected quickly: This computer s hardware may not support booting to this disk. Ensure that the disk s controller is enabled in the computer s BIOS menu.

Microsoft Windows Server 2008* HDD List

Microsoft Windows Server 2008* Installation Once the operating system installation completes, perform the following step: Update the SAS driver to 1.27.03 version For x86, file needed is Windows2K8_x86_Installation_Disk_1.27.03.zip. For x64, file needed is Windows2K8_x64_Installation_Disk_1.27.03.zip. Install the MPIO driver and reboot the compute module when prompted Complete the operating system installation by installing the following drivers in the order listed below. Reboot the compute module when prompted. NIC Graphics

Verifying MPIO Driver Installation Device Manager -> Disk drives Device Manager -> System Devices