Cable management for rack-mounted systems



Similar documents
Applying Proper Cable Management In IT Racks A Guide For Planning, Deployment And Growth

HP 16/18-Port Cable Management Kit Installation Guide

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

HP UPS R1500 Generation 3

Cable Routing Procedures for Dell PowerEdge R310 & R410 Systems

Rack installation instructions

HP Data Center Services

How To Fit A Dll 2420 And 4220 Rack Enclosure

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

Rack Installation Instructions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Intelligent Cable Management Systems

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

OCTOBER Layer Zero, the Infrastructure Layer, and High-Performance Data Centers

ADC-APC Integrated Cisco Data Center Solutions

4RU High Density Shelf Installation Instructions

Small form factor bay converter and hard drive installation

HP ProLiant DL165 G7 Server. Installation Instructions

Wall-Mounting your HP computer. User Guide

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Quick Reference Guide High Speed Input/Output Solutions

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

InstaPATCH ZERO Solution Guide

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, REV A.6 DECEMBER 9,

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

AC and DC Drive System Installation Information

Cabinets 101: Configuring A Network Or Server Cabinet

Metallized Particle Interconnect A simple solution for high-speed, high-bandwidth applications

AU-110 racking guide NBXPN: 023

HP Multimode OM3 LC/LC Optical Cables Overview. Models HP 50 m Multimode OM3 LC/LC Optical Cable

DATA CENTER RACK SYSTEMS: KEY CONSIDERATIONS IN TODAY S HIGH-DENSITY ENVIRONMENTS WHITEPAPER

Data Center Cabling Design Trends

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

Compaq Rack Options and Accessories. Monitors and Keyboards

Memory Modules User Guide

HP SATA/SAS hard drive and Solid State Drive installation

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

QuickSpecs. Models. HP Cable Lock Solutions for Business Notebook PCs Overview. HP Cable Lock. HP Docking Station Cable Lock

Fiber Optic Cable Installation

Redundancy in enterprise storage networks using dual-domain SAS configurations

Dimensions (HxDxW) Total Cabinet Area 89.96x x 24 in/ 2,285 x 1, x mm 95.47x 48 x 32 in/ 2,425 x 1,219.2 x 812.

COPPER FLEX PRODUCTS

Using Thermocouple Sensors Connecting Grounded and Floating Thermocouples

Cabinet V800 V800 CABINETS

Terminating 25-Pair Cable and 4-Pair Cross Connects

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

DATA CENTER SOLUTIONS GUIDE

InstaPATCH Cu Cabling Solutions for Data Centers

HP 2400/2500 Ultra Light Docking Station User Guide

Upgrading and Servicing Guide

Installation Instructions

Rack Installation Instructions

How To Build A T7 Rack For Information Technology

Statement of Work Server Migration & Cable Management. Installation Services. Table of Contents. 1.0 Executive Summary. 2.0 Features & Benefits

Access Server Rack Cabinet Compatibility Guide

Managing Data Centre Heat Issues

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

MCR1900 Media Converter 19-Slot Chassis

Introduction to the EMC CX High Density Rack Featuring CX4 UltraFlex Technology

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

The professional advantage: Quadro versus GeForce

Developing the Green Data Center

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Modem and Local Area Network

Secure your IT equipment with confidence... secure with NetClosure

MALONER. Installation & Loading Instructions - Please Read Before Beginning. Step 1: Installing Carriers to Cross Bars

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

Calculating power requirements for HP ProLiant rack-mounted systems

TubeTrace, ThermoTube

Modem and Local Area Networks. Document Part Number:

Rittal Liquid Cooling Series

Installation Instructions

Video Camera Installation Guide

SECTION 680 FIBER OPTIC CABLE DESCRIPTION

HP Port Switches Quick Setup Guide

What is a Datacenter?

Introducing Computational Fluid Dynamics Virtual Facility 6SigmaDC

Modifying the Yaesu FT-847 External MHz Reference Input

LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Single Channel Loop Detector

StorTrends 3400 Hardware Guide for Onsite Support

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

BIX Termination Blocks

Installing Your 960 or 980 Server into a Rackmount Cabinet

WHITE PAPER. Creating the Green Data Center. Simple Measures to Reduce Energy Consumption

Layer Zero. for the data center

5800 Temperature Sensor Cable Assembly

HP Color LaserJet CM1312 MFP Series Paper and Print Media Guide

QuickSpecs. HP Managed and Unmanaged Notebook Charging Carts. Models HP 30-Notebook Charging Cart

Open Rack Hardware v1.0

HP Managed and Unmanaged Notebook Charging Carts Overview. Models HP 30-Notebook Charging Cart. HP 30-Notebook Managed Charging Cart

Transcription:

Cable management for rack-mounted systems technology brief, 2 nd edition Abstract... 2 Introduction... 2 Cable routing guidelines... 3 Separation of power and data cables... 3 Retention of excess cable... 3 Protection of cables... 3 Securing cables and connectors... 3 Securing data cables... 3 Securing power cables and connectors... 4 Cable bend-radius restrictions... 4 Thermal issues with cable routing... 5 Routing fiber optic cable... 5 Routing network cable... 6 HP Cable Management Kit... 6 HP Factory Express services... 7 For more information... 8 Call to action... 8

Abstract High-density server installations involve an increasing amount of power and data cables within each rack. Mismanagement of cable assemblies can lead to poor system performance, difficult maintenance, unnecessary downtime, and even safety hazards. This paper describes proper methods and recommended techniques and products for safe and effective cable management. Introduction The trend in high performance computing (HPC) data centers is to implement high-density systems that make the most of available facility space. Of high importance with HPC systems are reliability and availability issues that are addressed with the use of redundant components and cabling. These strategies result in highly populated equipment racks with an abundance of power and data cables. As the component density of a rack increases, so does the need to manage associated cables effectively. Mismanaged or unmanaged cables (Figure 1) can result in several types of issues: Reduced performance due to signal crosstalk and interference across adjacent cables Difficult maintenance because components are blocked by cables Hazardous situations of damaged cables due to unchecked or unprotected movement Thermal (cooling) issues due to poor or restricted airflow around active components Any of the above situations can require unscheduled downtime to correct, and for enterprise HPC systems that is very costly and unacceptable. Effective management of power and data cabling of a rack can help achieve important overall goals of the IT infrastructure: Stable, reliable performance through reduced or eliminated crosstalk and interference Ease of serviceability and maintenance through better and safer access to individual components Thermal efficiency through maximum air flow for cost-efficient equipment cooling The following sections describe cabling management guidelines that can help achieve the goals of system design. HP solutions that address the cabling issues are also described. Figure 1. Examples of poor cable management in racks 2

Cable routing guidelines To minimize maintenance, safety, and performance issues, routing of power and data cables should be in accordance with the following guidelines. Separation of power and data cables Cables in close proximity to each other, especially those oriented in parallel or in loops, can create electromagnetic interference (EMI) through induction. EMI can result in erratic or error-prone data transfers. To minimize the effects of EMI, power cables should be segregated from data cables as much as possible: Dress all signal cables on the left side of the rack and all power cables on the right side of the rack. Arrange and secure excess power and data cabling separately. Use HP cable management kits described later in this paper to facilitate the segregation. Retention of excess cable Installing a number of components in a rack typically results in the use of some cables that are longer than necessary. This is especially true when similar or redundant components with the same cable types are installed at various levels in a rack. The excess cable lengths are often hurriedly bundled and tied, resulting in problems associated with EMI or in damaged cables. Here are some preferred methods of handling excess cables: Run and attach excess cables for easy, safe maintenance activities and proper operations. Ensure that secured cables are not pinched, damaged, or kinked (refer to the Cable bend radius restrictions section of this paper). When possible, use all cable management arms included in component kits. Use HP cable management kits described later in this paper for maintaining and managing cables. Protection of cables Cables must be protected at points where they might rub or come in contact with sharp edges or heated areas. Extra care must be used with power cables because damaged conductors could cause downtime and because exposed conductors are a safety hazard. To protect cables, HP recommends the following practices: Avoid dressing cables tightly over sharp edges of railing or panels. Avoid pinching of cables between components or mounting/sliding rails. Protect the cables if they may be pinched or damaged. Securing cables and connectors Cables and connectors should be secured to prevent excessive movement and to provide strain relief at critical points. Securing data cables For securing data cables, HP recommends the following practices: Ensure that cable connections are not stressed from any cable or chassis movement. Dress cables on management arms securely enough to prevent interference with movement or pinched cables, yet not so tight as to cause binding to the arm. 3

Securing power cables and connectors Power cables and connectors should receive extra care during installation, since loose cables or connectors can result in loss of power and unscheduled downtime. A loose power connector can create high contact resistance that can result in arcing and a fire hazard. HP power distribution products are often supplied with cable retaining clips or clamps (Figure 2), and HP strongly advises using these accessories when they are provided. For securing power cables and connectors, HP recommends the following: Always use any provided hardware (such as retaining clips or tie strips) to secure power connectors and cords to the product chassis. When possible, secure PDU power cables with removable ties to prevent accidental removal of the cords from the system. Figure 2. Example of retaining, clamp system securing power cords on HP products Cable bend-radius restrictions Routing cables typically requires looping excess cable or bending cable around chassis components. The bend radius is defined as the minimum radius (Figure 3) to which a cable may safely be bent without damaging the cable or affecting its performance. Figure 3. Cable bend radius Cable 0 R1 (bend radius at connector) R2 (bend radius away from connector) Radius (R) 90 R1 R2 To avoid the consequences of a too short or too tight bend radius, HP recommends the following practices: Avoid tight bend radii. Never bend cables tight enough to cause a crease in the sheathing. With no exceptions, fiber cables must not violate their minimum bend radius. Avoid excessive bends in cable, and run as large a bend as space allows. 4

Use cable routing accessories designed to maintain and secure cable. Leave enough slack in cables for operation of articulated arms and rail slides. Since actual conductor size and type vary among types of cables, the bend radius rule can differ among cable types. For example, Table 1 lists the minimum bend radius for HP fiber optic cables and HP InfiniBand cables. Table 1. Bend radius for HP cables Cable type Minimum bend radius (R, R1, or R2) HP LC-Type fiber optic HP SC-Type fiber optic HP InfiniBand 4xcable R = 0.8in (~2cm) R =1in (~3cm) R1 = 4.6in (12cm) R2 = 2.3in (6cm) Note The bend radius restrictions on some cable types, such as InfiniBand cable, vary depending upon connector proximity. For other cables, HP recommends that users refer to cable specifications or contact the cable supplier for more information. Excessive bending of cables can create one or more of the following problems: For power cables, stressed insulators or arcing across conductors For copper data cables, stressed terminators, stress on center conductors, or disturbed twists on conductors that increase sensitivity to noise For fiber optic cables, micro-bending of fibers that results in degradation of light transmission or breaking of fibers, which results in loss of signal Thermal issues with cable routing HP rack-mountable products that use forced-air cooling typically draw cool air through the front of the chassis and push warm air out the back. If this air flow is restricted in any way, component temperatures can rise, resulting in unscheduled system downtime due to thermal shutdown or damage. For safe and reliable operation, ventilation slots and blowers at the rear of products must not be obstructed by any components, including cables. Therefore, for proper cooling of rack-mounted components, ensure that cabling does not impede the airflow to or from the rack-mountable servers. Routing fiber optic cable Fiber optic cable is lighter than copper cable; but it is relatively delicate, must be handled carefully during installation, and may require extra protection. Damaged fiber optic cable poses no safety hazards but can result in degraded or interrupted performance. HP recommends the following guidelines for installing fiber optic cable: Use only Velcro ties to reduce the chance of damaging cable from over-cinching or accidental cutting. 5

Do not allow other cables or components to exert tension on fiber optic cables, which can be easily crushed or damaged. Avoid routing fiber optic cable around chassis and cabinet corners. If this is unavoidable, protect the cable. Routing network cable Network interconnects can involve a large amount of cabling due to the component/data path redundancy required to meet high availability goals. Network devices also require high serviceability, so cabling must be arranged to allow easy access to individual circuits. HP recommends the following guidelines for routing data cables: For components that must be movable while powered on, ensure that a full range of motion is possible without cable interference or disconnection. When securing cables inside the rack, dress the bundle in a way that avoids interference with installed components, rack side panels, or rails. Do not block access to field-replaceable components. HP Cable Management Kit HP offers a complete line of products that provide reliable, serviceable, and safe cabling options for assembling rack installations. Routing, securing, and protection solutions available from HP are listed in Table 2 and can be found at the main rack options product page at www.hp.com/products/rackoptions. 6

Table 2. HP cabling solutions Product HP part number Description Cable Management D-ring Kit 168233-B21 This kit contains 10 D-rings that mount in the back rails of the rack and allow for cables to be routed and organized within the rack. Network Cable Management Kit AF099A This kit provides an easy way to organize and route cables within HP racks. Cable clips, cable rings, and 1U and 2U access panels are included. Hook and Loop Strips 379820-B21 Adjustable, reusable strap with metal clip that can attach to rack perforations or other clips. Rack-Top Cable Tray 383982-B21 (600mmWide) 383983-B21 (800mm wide) Designed to mount on top of the HP Rack 10000 Series for orderly and efficient cable routing. The three levels within the trays allow for routing power, data, and fibre channel cables separately. Rack-to-Rack Adjustable Cable Tray, Aisle Transfer Bridge 383984-B21 Adjustable cable bridge used to transfer cables from the back of a rack, across the datacenter hot aisle, to the back of another rack. Comes in a single size. HP Factory Express services HP provides system integration services through HP Factory Express, 1 an extensive portfolio of more than 50 services. Through Factory Express, HP offers routing and cabling management service in accordance with the best cabling practices. 1 HP Factory Express is a robust portfolio of flexible, pre-priced, configured, customized, and integrated factory solutions and deployment services. Through Factory Express, HP racks can be customized, configured, and integrated into ready-to-deploy solutions to save customers time, money, and resources. 7

For more information For additional information about racks, rack options, and accessories, refer to the HP Infrastructure Products page at http://h18004.www1.hp.com/products/servers/platforms/rackandpower.html. To learn more about HP Factory Express, contact your HP sales representative or visit our website at www.hp.com/go/factory-express. Call to action Send comments about this paper to TechCom@HP.com. 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.. TC071203TB, December 2007