CHAPTER 4 VENTILATION AIR SUPPLY

Similar documents
VENTILATION CHAPTER 4

CHAPTER 4 VENTILATION

CHAPTER 4 VENTILATION

VENTILATION CHAPTER 4

VENTILATION CHAPTER 4

Ventilation for Acceptable Indoor Air Quality

AG-TQS-IAQ-00 March 4, Application Guide. TQS with IAQ Inlet

Fan Applications & System Guide

CHAPTER 29 PLUMBING SYSTEMS

VAV Laboratory Room Airflow The Lowdown on Turndown

Table PARKING SPACE RATES AND PARKING SPACE OCCUPANCY

CHAPTER 29 PLUMBING SYSTEMS. [P] TABLE MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES a (See Sections and ) 1 per 40 for the

Flexibility, Efficiency In San Antonio Arena

DOAS UNITS. MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR. Kitchens Hotel Corridors Laboratories. Paint Booths. Capacities Tons MBH

Mechanical Technical Assignment One ASHRAE Standard 62.1 and Standard 90.1 Evaluation

Integrating Kitchen Exhaust Systems with Building HVAC

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

Element D Services Heating, Ventilating, and Air Conditioning

TABLE Lighting Power Densities Using the Space-by-Space Method(continued) TABLE Lighting Power Densities Using the Space-by-Space Method

ASHRAE Std Update Where Are We Now?

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

Chapter 3: Use and Occupancy Classification

Schedule B to By-law Part A Fees Payable for Permits

SAM HOUSTON STATE UNIVERSITY

Georgia Smokefree Air Act O.C.G.A A-1 through 31-12A-13

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Single Family Residential Basement Finish

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

Pool Dehumidification Basics

Raising the Bar: A Comparison Study of Iowa s Current and Proposed Energy Code

Dual Maximum VAV Box Controls

MULTIZONE APPLICATION OF SOLUTION UNITS

Schedule B to By-law

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

Carbon Monoxide Detection in Commercial Buildings (

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions

HVAC Systems: Overview

CHAPTER 5 Energy Efficient HVAC Design

Revised: Previously Issued As: P/BC PLUMBING FIXTURES

TOWNSHIP OF CRANFORD CRANFORD, NEW JERSEY. Ordinance No

SCHEDULE A BY-LAW B-6 CLASSES OF PERMITS AND FEES

Displacement ventilation

Section 6. Off-street Bicycle Space Regulations

BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS

Retail or Wholesale In conformity with the provisions of sub-section Art Gallery, Museum or Library In conformity with the

ORDINANCE NO Ordinance No Page 1 of 7. Language to be added is underlined. Language to be deleted is struck through.

CHAPTER 9 FIRE PROTECTION SYSTEMS

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

newsletter Let s take a high-level look at airside economizing: what it is, what it requires, and how it s done. How does economizer cooling work?

2006 Delta T Corporation dba Big Ass Fan Company

APPLICATION GUIDE. Moisture Management in Waterborne Climate Systems

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

Comparing Energy Savings of Different VAV Systems

Vectren Commercial/Industrial New Construction Incentive Application

This notice sets forth interim guidance, pending the issuance of regulations,

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

Part III. Administrative, Procedural, and Miscellaneous

Division S-37. PD Subdistrict 37.

CITY OF FAIRFAX CODE ADMINISTRATION / FAX

How To Design A Building In New Delhi

HVAC Checklist - Long Form

Commercial Energy Use Worksheet

Dehumidification Design

Chapter PLUMBING CODE

Glossary of HVAC Terms

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

Circulator Fan Performance Testing Standards BY CHRISTIAN TABER, BEMP, HBDP, MEMBER ASHRAE

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

Mechanical Systems. Mechanical Systems to build a better community. Table of Contents. Team Registration Number

Final - Adopted February 6, 2012 AN ORDINANCE

Attached (townhouses) SC P P 4.2.3(A)1 Duplex SE SE P Accessory Dwelling Unit (ADU) to a primary residence SC SC SC SC P 4.2.3(A)2

Chignecto-Central Regional School Board. Highland Consolidated Middle School. Indoor Air Quality Issues Mechanical Systems

OCFRD TENT STANDARD This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.

Supplemental Plan Check Corrections Sheet for Bicycle Parking Ordinance (Effective 3/13/2013)

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Demand Control Ventilation Application Guide for Consulting Engineers E Rev. 3, August 2013

Case Studies: Infrared Heating in Industrial Applications

City of Riverside. Building & Safety Division Phone: (951)

Key energy-efficient features of your new home

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

SUPPLEMENTAL APPLICATION Hotels & Resorts Insurance Program CITA Insurance Services A division of Brown & Brown Program Insurance Services, Inc.

DRYER VENTING SPECIFICATIONS DRYER SAFETY

ARTICLE C-1 COMMERCIAL ZONE

Basic Selection & Proper Application of Overhead Air Distribution Devices

General Lighting Recommendations

Amplification of Notice ; Deduction for Energy Efficient Commercial Buildings

BEC 2012 Vs BEC Summary of Major Amendments

HVAC Code Requirements

Errata has been identified as follows:

BUILDING PERMIT SPECIFICATIONS

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Property Maintenance Check List

2011 Energy Efficiency Expo!

Climotion ensures a better climate. Better comfort and lower costs in all buildings. Bosch Energy and Building Solutions

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

Transcription:

CHAPTER 4 VENTILATION AIR SUPPLY 401.0 General. 401.1 Applicability. This chapter contains requirements for ventilation air supply, exhaust, and makeup-air requirements for occupiable spaces within a building. 402.0 Ventilation Air. 402.1 General Requirements. Occupiable spaces listed in Table 402.1 shall be designed to have ventilation (outdoor) air for occupants in accordance with this chapter. 402.1.1 Construction Documents. The outdoor air ventilation rate and air distribution assumptions made in the design of the ventilation system shall be clearly identified on the construction documents. 402.1.2 Dwelling. Requirements for ventilation air rate for single family dwellings shall be in accordance with this chapter or ASHRAE 62.2. 402.2 Natural Ventilation. Use of nnatural ventilation systems shall be designed in accordance with this section and shall be permitted in lieu of or in conjunction with include mechanical ventilation systems designed in accordance with Section 403.0 and Section 404.0. [ASHRAE 62.1:5.16.4] Exceptions: (1) An engineered natural ventilation system when where approved by the Authority Having Jurisdiction need not meet the requirements of comply with Section 402.2.1 402.2 and Section 402.2.2. (2) A mechanical ventilation system is not required where natural ventilation openings comply with the requirements of Section 402.2 and are permanently open or have controls that prevent the openings from being closed during occupancy. (3) A mechanical ventilation system is not required where the zone is not served by heating or cooling equipment. 402.2.1 Location and Size of Openings. Naturally ventilated spaces shall be permanently open to and within 25 feet (7620 mm) of by way of operable wall or roof openings directly to the outdoors, the openable area of which is a minimum of 4 percent of the net occupiable floor area. Where the openings are covered with louvers or otherwise obstructed, openable area shall be based on the free unobstructed area through the opening. Where interior spaces without direct openings to the outdoors are ventilated through adjoining rooms, the opening between rooms shall be permanently unobstructed and have a free area of not less than 8 percent of the area of the interior room nor less than 25 square feet (ft 2 ) (2.3 m 2 ). [ASHRAE 62.1:5.1.16.4.2] 402.2.2 Control and Accessibility. The means to open required operable openings shall be readily accessible to building occupants whenever where the space is occupied. Controls shall be designed to coordinate operation of the natural and mechanical ventilation system. [ASHRAE 62.1:5.1.2 6.4.3] 402.3 Mechanical Ventilation. Where natural ventilation is not permitted by this section or the building code, mechanical ventilation systems shall be designed, constructed, and installed to provide a method of supply air and exhaust air. Mechanical ventilation systems shall include controls, manual or automatic, that enable the fan system to operate wherever the spaces served are occupied. The system shall be designed to maintain minimum outdoor airflow as required by Section 403.0 under any load conditions. 314.5 402.4 Outsidedoor Air Inlet Intake Protection. Required outsidedoor-air inlets intakes shall be covered with a screen having not less than 1 4 of an inch (6.4 mm) openings, and shall have not more than 1 2 inch (12.7 mm) openings. Exception: An outside-air inlet serving a nonresidential portion of a building shall be permitted to be covered with a screen having openings larger than 1 4 of an inch (6.4 mm), but in no case exceeding 1 inch (25.4 mm). 402.4.1 Weather Protections. Outdoor air intakes that are part of the mechanical ventilation system shall be designed to manage rain entrainment, to prevent rain intrusion, and manage water from snow in accordance with ASHRAE 62.1. 403.0 Ventilation Rates. 403.1 General. The design outdoor air intake flow rate for a ventilation system shall be determined in accordance with Section 403.12 through Section 403.78. 403.12 Zone Calculations. Zone parameters shall be determined in accordance with Section 403.12.1 through Section 403.12.3. [ASHRAE 62.1:6.2.2] 403.12.1 Breathing Zone Outdoor Airflow. The design outdoor airflow required in the breathing zone of the occupiable space or spaces in a zone, i.e., the breathing zone outdoor airflow (V bz ), shall be determined in accordance with Equation 403.12.1. [ASHRAE 62.1:6.2.2.1] V bz = R p P z + R a A z (Equation 403.12.1) Where: A z = zone floor area: the net occupiable floor area of the zone in square feet (m 2 ). P z = zone population: The largest number of people expected to occupy the zone during typical usage. If the number of people expected to occupy the zone fluctuates, P z shall be permitted to be estimated based on averaging approaches described in Section 403.56.21. If P z cannot be accurately predicted during design, it shall be estimated based on the zone floor area and the default occupant density listed in Table 402.1. UNIFORM MECHANICAL CODE 35

R p = outdoor airflow rate required per person as determined from Table 402.1. R a = outdoor airflow rate required per unit area as determined from Table 402.1. [ASHRAE 62.1:6.2.2.1] 403.12.2 Zone Air Distribution Effectiveness. The zone air distribution effectiveness (E z ) shall be determined using Table 403.12.2. [ASHRAE 62.1:6.2.2.2] 403.12.3 Zone Outdoor Airflow. The design zone outdoor airflow (V oz ), i.e., the outdoor airflow that must shall be provided to the zone by the supply air distribution system, shall be determined in accordance with Equation 403.12.3. [ASHRAE 62.1:6.2.2.3] V oz = V bz /E z (Equation 403.12.3) 403.23 Single-Zone Systems. Where one air handler supplies a mixture of outdoor air and recirculated air to only one zone, the outdoor air intake flow (V ot ) shall be determined in accordance with Equation 403.23. [ASHRAE 62.1:6.2.3] V ot = V oz (Equation 4-3 403.23) 403.34 One Hundred Percent Outdoor Air Systems. Where one air handler supplies only outdoor air to one or more zones, the outdoor air intake flow (V ot ) shall be determined in accordance with Equation 403.34. [ASHRAE 62.1:6.2.4] V ot = all zones V oz (Equation 403.34) 403.45 Multiple-Zone Recirculating Systems. Where one air handler supplies a mixture of outdoor air and recirculated return air to more than one zone, the outdoor air intake flow (V ot ) shall be determined in accordance with Section 403.45.1 through Section 403.45.4. [ASHRAE 62.1:6.2.5] 403.45.1 Primary Outdoor Air Fraction. Where Table 403.4.1 is used to determine system ventilation efficiency, tthe zone primary outdoor air fraction (Z pz ) shall be determined for ventilation zones in accordance with Equation 403.45.1. [ASHRAE 62.1:6.2.5.1] 403.45.3 Uncorrected Outdoor Air Intake. The design uncorrected outdoor air intake (V ou ) shall be determined in accordance with Equation 403.45.3(a1). V ou = D all zones R p P z + all zones R a A z (Equation 403.45.3(a1)) The occupant diversity, D, shall be permitted to be used to account for variations in occupancy within the zones served by the system. The occupancy diversity is defined as determined in accordance with Equation 403.5.3(2): D = P s / all zones P z (Equation 403.45.3(b2)) Where the system population (P s ) is the total population in the area served by the system. Alternative methods shall be permitted to be used to account for population diversity when calculating V ou, provided that the resulting value is no less than that determined by Equation 403.45.3(a1). [ASHRAE 62.1:6.2.5.3] 403.45.4 Outdoor Air Intake. The design outdoor air intake flow (V ot ) shall be determined in accordance with Equation 403.45.4. [ASHRAE 62.1:6.2.5.4] V ot = V ou /E v (Equation 403.45.4) 403.56 Design for Varying Operating Conditions. 403.5.1 Variable Load Conditions. Ventilation systems shall be designed to be capable of providing the required ventilation rates in the breathing zone whenever the zones served by the system are occupied, including all full and partload conditions. [ASHRAE 62.1:6.2.6.1] 403.56.21 Short-Term Conditions. Where it is known that peak occupancy will be of short duration or the ventilation rate will be varied or interrupted for a short period of time, the design shall be permitted to be based on the average conditions over a time period (T) determined by in accordance with Equation 403.56.21. [ASHRAE 62.1:6.2.6.2]: T = 3v/V bz (4-9 50v/V bz ) IP (Equation 403.56.21) Z pz = V oz /V pz (Equation 403.45.1) V pz is the primary airflow to the ventilation zone from the air handler, including outdoor air and recirculated return air. [ASHRAE 62.1:6.2.5.1] 403.45.2 System Ventilation Efficiency. The system ventilation efficiency (E v ) shall be determined using in Table 403.45.12 or Section 404.0. [ASHRAE 62.1:6.2.5.2] Acceptable design adjustments based on this optional provision shall be in accordance with the following [ASHRAE 62.1:6.2.6.2]: (1) Zones with fluctuating occupancy: The zone population (P z ) shall be averaged over time (T). (2) Zones with intermittent interruption of supply air: The average outdoor airflow supplied to the breathing zone over time (T) shall be not less than the breathing zone outdoor airflow (V bz ) calculated using Equation 403.2.1. 36 UNIFORM MECHANICAL CODE

(3) Systems with intermittent closure of the outdoor air intake: The average outdoor air intake over time (T) shall be not less than the minimum outdoor air intake (V ot ) calculated using Equation 403.3, 403.4, or 403.5.4. Where: T = averaging time period, (minutes) v = the volume of the zone for which averaging is being applied, ft 3 (m 3 ) V bz = the breathing zone outdoor airflow calculated using shall be determined in accordance with Equation 403.12.1 and design value of the zone population P z, cfm (L/s m 3 /min). 403.67 Exhaust Ventilation. Exhaust airflow shall be provided in accordance with the requirements in Table 403.67. Exhaust makeup air shall be permitted to be any a combination of outdoor air, recirculated air, and transfer air. 403.78 Dynamic Reset. The system shall be permitted to be designed to vary the design outdoor air intake flow (V ot ), or the space or zone airflow, and the exhaust air flow as operating conditions change. [ASHRAE 62.1:6.2.7] 404.0 Multiple-Zone Systems. 404.1 General. This section presents an alternative procedure for calculating the system ventilation efficiency (E v ) where values in Table 403.45.12 are not used. E v is equal to the lowest calculated value of the zone ventilation efficiency E vz, as shown below: Ev = minimum (Evz) (Equation 404.1) [ASHRAE 62.1: Equation A-38] 404.2 Zone Ventilation Efficiency. The zone ventilation efficiency E vz, is an efficiency which a system distributes outdoor air from the intake to an individual breathing zone. The zone ventilation efficiency shall be calculated using Equation 404.2.1 or Equation 404.2.2. [ASHRAE 62.1: Appendix A] 404.2.1 Single Supply Systems. Equation 404.2.1 or Equation 404.2.2 shall be used for single supply systems, where all the ventilation air is a mixture of outdoor air and recirculated air from a single location (e.g., reheat, single-duct VAV, single-fan dual-duct, and multizone). [ASHRAE 62.1: Appendix A] it with outdoor air (e.g., dual-fan dual-duct, fan-powered mixing box, and transfer fans for conference rooms). [ASHRAE 62.1: Appendix A] Evz = (Fa + Xs Fb Zd Fc)/Fa (Equation 404.2.2) [ASHRAE 62.1: Equation A-23] Where: Ep - Primary air fraction to the zone: Ep = Vpz/Vdz (Ep = 1.0 for single-duct and single-zone systems). Er - In systems with secondary recirculation of return air, fraction of secondary recirculated air to the zone that is representative of average system return air rather than air directly recirculated from the zone. Fa - Fraction of supply air to the zone from sources outside the zone: Fa = Ep + (1 Ep) Er. Fb - Fraction of supply air to the zone from fully mixed primary air: Fb = Ep. Fc - Fraction of outdoor air to the zone from sources outside the zone: Fc = 1 (1 Ez) (1 Er) (1 Ep). Xs - Average Outdoor Air Fraction: At the primary air handler, the fraction of outdoor air intake flow in the system primary airflow, Xs = Vou/Vps. Vps - System Primary Airflow: The total primary airflow supplied to all zones served by the system from the airhandling unit at which the outdoor air intake is located, Vps = ΣVpz Zd - Discharge Outdoor Air Fraction: The outdoor air fraction required in air discharged to the zone, Zd = Voz/Vdz. Z pz - Primary Outdoor Air Fraction required in the primary air supplied to the ventilation zone prior to the introduction of a secondary recirculation air, Z pz = V oz / V pz Vdz - Zone Discharge Airflow: The expected discharge (supply) airflow to the zone that includes primary airflow and locally recirculated airflow. E vz = 1+X s Z dpz (Equation 404.2.1) [ASHRAE 62.1: Equation A-12] 404.2.2 General Case. Equation 404.2.2 shall be used for systems that provide all or part of their ventilation by recirculating air from other zones without directly mixing UNIFORM MECHANICAL CODE 37

OCCUPANCY CATEGORY 4 TABLE 402.1 MINIMUM VENTILATION RATES IN BREATHING ZONE 1, 2 [ASHRAE 62.1: TABLE 6-1] PEOPLE OUTDOOR Air Rate R P (cfm/person) AREA OUTDOOR Air Rate R A (cfm/ft 2 ) DEFAULT OCCUPANT Density 3 (people/1000 ft 2 ) CORRECTIONAL FACILITIES Booking/waiting 7.5 0.06 50 Cell 5 0.12 25 Day room 5 0.06 30 Guard stations 5 0.06 15 EDUCATIONAL FACILITIES Art classroom 10 0.18 20 Classrooms (ages 5-8) 10 0.12 25 Classrooms (age 9 plus) 10 0.12 35 Computer lab 10 0.12 25 Day care (through age 4) 10 0.18 25 Day care sickroom 10 0.18 25 Lecture classroom 7.5 0.06 65 Lecture hall (fixed seats) 7.5 0.06 150 Media center A 10 0.12 25 Music/theater/dance 10 0.06 35 Multi-use assembly 7.5 0.06 100 Science laboratories E 10 0.18 25 University/college laboratories 10 0.18 25 Wood/metal shop 10 0.18 20 FOOD AND BEVERAGE SERVICE Bars, cocktail lounges 7.5 0.18 100 Cafeteria/fast food dining 7.5 0.18 100 Kitchen (cooking) 7.5 0.12 20 Restaurant dining rooms 7.5 0.18 70 GENERAL Break rooms 5 0.06 25 Coffee stations 5 0.06 20 Conference/meeting 5 0.06 50 Corridors 0.06 Occupiable Sstorage rooms for liquids or gels B 5 0.12 2 HOTELS, MOTELS, RESORTS, DORMITORIES Bedroom/living room 5 0.06 10 Barracks sleeping areas 5 0.06 20 Laundry rooms, central 5 0.12 10 Laundry rooms within dwelling units 5 0.12 10 Lobbies/pre-function 7.5 0.06 30 Multipurpose assembly 5 0.06 120 OFFICE BUILDINGS Breakrooms 5 0.12 50 Occupiable storage rooms for dry materials 5 0.06 2 Office space 5 0.06 5 Main entry lobbies 5 0.06 10 Reception areas 5 0.06 30 Telephone/data entry 5 0.06 60 MISCELLANEOUS SPACES Bank or bank lobbies 7.5 0.06 15 Bank vaults/safe deposit 5 0.06 5 Computer (not printing) 5 0.06 4 Electrical equipment rooms - 0.06 - Elevator machine rooms - 0.12 - General manufacturing (excludes heavy industrial and processes using chemicals) 10 0.18 7 38 UNIFORM MECHANICAL CODE

OCCUPANCY CATEGORY 4 TABLE 402.1 (continued) MINIMUM VENTILATION RATES IN BREATHING ZONE 1, 2 [ASHRAE 62.1: TABLE 6-1] PEOPLE OUTDOOR Air Rate R P (cfm/person) AREA OUTDOOR Air Rate R A (cfm/ft 2 ) DEFAULT OCCUPANT Density 3 (people/1000 ft 2 ) Pharmacy (prep. area) 5 0.18 10 Photo studios 5 0.12 10 Shipping/receiving B 10 0.12 2 Sorting, packing, light assembly 7.5 0.12 7 Telephone closets 0.00 Transportation waiting 7.5 0.06 100 Warehouses B 10 0.06 PUBLIC ASSEMBLY SPACES Auditorium seating area 5 0.06 150 Courtrooms 5 0.06 70 Legislative chambers 5 0.06 50 Libraries 5 0.12 10 Lobbies 5 0.06 150 Museums (children s) 7.5 0.12 40 Museums/galleries 7.5 0.06 40 Places of religious worship 5 0.06 120 RESIDENTIAL Common corridors 0.06 Dwelling unit F, G 5 0.06 F RETAIL Barber shop 7.5 0.06 25 Beauty and nail salons 20 0.12 25 Coin-operated laundries 7.5 0.060.12 20 Mall common areas 7.5 0.06 40 Pet shops (animal areas) 7.5 0.18 10 Sales (except as below) 7.5 0.12 15 Supermarket 7.5 0.06 8 SPORTS AND ENTERTAINMENT Bowling alley (seating) 10 0.12 40 Disco/dance floors 20 0.06 100 Gambling casinos 7.5 0.18 120 Game arcades 7.5 0.18 20 Gym, stadium (play area) 0.30 30 Health club/aerobics room 20 0.06 40 Health club/weight rooms 20 0.06 10 Sports arena (play area) 0.30 Spectator areas 7.5 0.06 150 Stages, studios D 10 0.06 70 Swimming (pool & deck) C 0.48 For SI units: 1 cubic foot per minute = 0.47 L/s 0.0283 m 3 /min, 1 square foot = 0.0929 m 2 Notes: 1 Smoking: This table applies to no-smoking areas. Rates for smoking-permitted spaces must be determined using other methods. 2 Air Density: Volumetric airflow rates are based on an air density of 0.075 lbda/ft 3 (1.2 kgda/m 3 ), which corresponds to dry air at a barometric pressure of 1 atm (101.3 kpa) and an air temperature of 70 F (21 C). Rates shall be permitted to be adjusted for actual density but such adjustment is not required for compliance with this chapter. 3 Default Occupant Density: The default occupant density shall be used where actual occupant density is not known. 4 Unlisted Occupancies: Where the occupancy category for a proposed space or zone is not listed, the requirements for the listed occupancy category that is most similar in terms of occupant density, activities, and building construction shall be used. ITEM-SPECIFIC NOTES FOR TABLE 402.1 a For high school and college libraries, use values shown for Public Spaces Library. b Rate may is capable of not being sufficient when where stored materials include those having potentially harmful emissions. c Rate does not allow for humidity control. Additional ventilation or dehumidification shall be permitted to be required to remove moisture. d Rate does not include special exhaust for stage effects, (e.g., dry ice vapors, smoke). e No class of air has been established for this occupancy category. f Default occupancy for dwelling units shall be two persons for studio and one-bedroom units, with one additional person for each additional bedroom. g Air from one residential dwelling shall not be recirculated or transferred to other space outside of that dwelling. UNIFORM MECHANICAL CODE 39

TABLE 403.12.2 1, 2, 3, 4, 5 ZONE AIR DISTRIBUTION EFFECTIVENESS [ASHRAE 62.1: TABLE 6-2] AIR DISTRIBUTION CONFIGURATION Ez Ceiling supply of cool air 1.0 Ceiling supply of warm air and floor return 1.0 Ceiling supply of warm air at least 15 F above space temperature and ceiling return. 0.8 Ceiling supply of warm air less than 15 F above space temperature and ceiling return provided that the 150 feet 1.0 per minute (fpm) supply air jet reaches to within 4.5 feet of floor level. Floor supply of cool air and ceiling return provided that the 150 fpm (0.8 m/s) supply jet reaches at least 4.5 feet 1.0 above the floor. Floor supply of cool air and ceiling return, provided low velocity displacement ventilation achieves unidirectional 1.2 flow and thermal stratification. Floor supply of warm air and floor return 1.0 Floor supply of warm air and ceiling return 0.7 Makeup supply drawn in on the opposite side of the room from the exhaust or return. 0.8 Makeup supply drawn in near to the exhaust or return location 0.5 For SI units: t/ C=(t/ F-32)/1.8, 1 foot per minute = 0.005 m/s, 1 foot = 304.8 mm Notes: 1 Cool air is 1.8, 1 foot per minute air cooler than space temperature. 2 Warm air is air warmer than space temperature. 3 Ceiling includes any point above the breathing zone. 4 Floor includes any point below the breathing zone. 5 As an alternative to using the above values, determine E z in accordance with ASHRAE Standard 129 for all air distribution configurations except unidirectional flow. TABLE 403.45.12 SYSTEM VENTILATION EFFICIENCY [ASHRAE 62.1: TABLE 6-3] MAx (Z P ) E v 0.15 1.0 0.25 0.9 0.35 0.8 0.45 0.7 0.55 0.6 > 0.55 Use Section 404.0 Notes: 1 Max Zp refers to the largest value of Zp, calculated using Equation 403.45.1, among all the zones served by the system. 2 Interpolating between table values is permitted. 3 The values of E v in this table are based on a 0.15 average outdoor air fraction for the system (e.g., the ratio of the uncorrected outdoor air intake Vou to the total zone primary airflow for all the zones served by the air handler). For systems with higher values of the average outdoor air fraction, this table is capable of resulting in unrealistically low values of Ev and the use of Section 404.0 will yield more practical results. 1, 2, 3 40 UNIFORM MECHANICAL CODE

OCCUPANCY CATEGORY 6 TABLE 403.67 MINIMUM ExHAUST RATES [ASHRAE 62.1: TABLE 6-4] ExHAUST RATE (cfm/unit) ExHAUST RATE (cfm/ft 2 ) Arena 2-0.50 Art classrooms - 0.70 Auto repair rooms 1-1.50 Barber shop - 0.50 Beauty and nail salons - 0.60 Cell with toilet - 1.00 Copy, printing rooms - 0.50 Darkrooms - 1.00 Science lab classrooms Educational science laboratories - 1.00 Janitor closets, trash rooms, recycleing - 1.00 Kitchen commercial - 0.70 Kitchenettes - 0.30 Locker rooms - 0.50 Locker/dressing rooms - 0.25 Parking garages 3, 7-0.75 Pet shops (animal areas) - 0.90 Residential kitchens 50/100 - Soiled laundry storage rooms - 1.00 Storage rooms, chemical - 1.50 Toilets public 4 50/70 - Toilet private 5 25/50 - Woodwork shop/classroom - 0.50 For SI units: 1 cubic foot per minute = 0.47 L/s 0.0283 m 3 /min, 1 square foot = 0.0929 m 2 Notes: 1 Stands where engines are run shall have exhaust systems that directly connect to the engine exhaust and prevent escape of fumes. 2 The rates do not include exhaust from vehicles or equipment with internal combustion engines. 3 Exhaust rate is not required for open parking garages as defined in accordance with the building code. 4 Rate is per water closet or urinal. Provide the higher rate where periods of heavy use are expected to occur, e.g., toilets in theatres, schools, and sports facilities. 5 Rate is for a toilet room intended to be occupied by one person at a time. For continuous system operation during normal hours of use, the lower rate may shall be used. Otherwise use the higher rate. 6 For unlisted occupancies for a proposed space not listed in the table, the requirements for the listed occupancy that is most similar in terms of occupant density and occupancy type shall be used. 7 Exhaust rate is not required for enclosed parking garages having a floor area of 1000 square feet (92.9 m 2 ) or less and used for the storage of five or less motorized vehicles. 8 For continous system operation, the lower rates shall be permitted. Otherwise the higher rate shall be used. UNIFORM MECHANICAL CODE 41

42 UNIFORM MECHANICAL CODE