I. Introduction. 10 minutes

Similar documents
WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

FIVE YEAR CERTIFICATION REPORT

Fire Hydrant Troubleshooting

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

Firefighter Review. Instructor Guide

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Water Storage Tanks. (Cisterns) Drinking water and your health. Water Hauling. Rainwater Collection. Construction Material

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

OREGON FIRE CODE Interpretations and Technical Advisories

CHAPTER. Standpipes and Hose Systems OVERVIEW. Standpipe and Hose Systems Defined

Automatic Fire Sprinkler Submittal Requirements

FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?

4.3 Cisterns and Rain Barrels

TRAINING BULLETIN Fire Apparatus Pump Test

ACCUMULATOR INSTALLATION

Inexpensive Leak Detection for Small Waterworks. Virginia Department of Heath Office of Drinking Water Catalog Number: HTO/005/2015

Inspection and Testing of Water-Based Systems

Important Ontario Fire Code Information for Building Owners in the City of Windsor

The In-Line Gauge in Standpipe Operations

TECHNICAL ADVISORY BULLETIN

SPRINKLER SYSTEM PLANS AND CALCULATIONS CHECK LIST

Element D Services Plumbing

Pressure Vessels (Air Compressors) and LPG Tanks

Potter Electric Sprinkler Monitoring Training Manual

TABLE OF CONTENT

15430 SAFETY SHOWERS AND EYEWASHES

American- Darling 5¼" B-84-B-5.

NITROUS TRANSFER PUMP INSTRUCTIONS

Design Criteria & Service Goals

Clark County Fire Prevention

Watts Pure Water Systems

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Repair and Disinfection of Water Mains Water Protection Program fact sheet

Ponds- Planning, Design, Construction

Hydrant flow testing data provides important

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

Inspection and Testing Program Fire Protection Equipment

Please keep this manual for f uture reference.

SANITARY SEWER SPECIFICATIONS

Rexroth Hydraulic Pump A10VO Series User Manual

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Natural Gas Emergencies

OTF Oil Fired Pool Heater

UPPER MOHAWK VALLEY REGIONAL WATER BOARD SERVICE AREA. City of Utica

Maintaining Fire Protection Systems

Commercial Fire Inspections

Design & Construction Standards, Revised January

STORED PRESSURE STAINLESS STEEL

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

Water Shortage Contingency Plan

123 Industrial Loop Road Paynesville, MN Phone:

Compressed Gas Cylinder Program

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

Preventing water damage in the basement

Winnipeg Fire Department Fire Prevention Branch

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

Toms River Fire Academy

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

FILLING AND PURGING THE SYSTEM

Standard Hydraulic Piping Flushing Procedure

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment):

FIRE DEPARTMENT HYDRAULICS

Diesel Fuel Systems. Injection Nozzles

STEAMBOAT LAKE WATER AND SANITATION DISTRICT PETITION FOR AMENDMENT TO SERVICE PLAN TABLE OF CONTENTS. SECTION DESCRIPTION Page

WATER SUPPLIES MANUAL

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Insurance Services Offices Inc.

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

Maintenance Guide For Above Ground Pools

Pressure Testing Procedures for Building Services Piping

WATER SUPPLY SYSTEMS FOR 150/5220-4B AAS-100 AIRCRAFT FIRE AND RESCUE PROTECTION

Backup Fuel Oil System Decommissioning & Restoration Plan

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

SUBCHAPTER 17 FIRE ALARM, DETECTION AND EXTINGUISHING EQUIPMENT

Civil Engineering Sector Labour-Management Health and Safety Committee

WARNING WARNING TABLE 1.

Course Title: Introduction to Fire Science

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Training Guide. An Introduction to Water Loss and Leak Detection

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

Fire Pump Plan Review March 2010

WATER SUPPLY PROCEDURES MANUAL MECHANICSVILLE VOLUNTEER FIRE DEPARTMENT

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

Automatic fire-extinguishing systems for commercial cooking

MOTOR FUEL DISPENSING SAFETY

Fire Safety Plan (Single-Stage Fire Alarm System - Small Establishment)

FLUSHOMETER - TANK SYSTEM

15CI and 25CI Reversing Motor Pumpset Owner's Manual

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

Transcription:

I. Introduction 10 minutes

Introduction (1 of 2) An uninterrupted water supply is: The primary weapon for extinguishment Essential for fire fighter safety Ensuring a dependable water supply is a critical fireground operation and must be accomplished right away.

Introduction (2 of 2) Water sources include: Municipal and private water systems Static water sources Mobile water supply operations

II. Municipal Water Systems 25 minutes

Municipal Water Systems Provide clean water for public use. Provide water for fire protection. Most are owned and operated by a local government agency. But some privately owned Systems includes a water source, a treatment plant, and a distribution system.

Water Sources Sources include: Wells Rivers or streams Lakes Reservoirs Many systems draw water from several sources.

Water Treatment Facilities Remove impurities All water must be suitable for drinking. Chemicals used to kill bacteria and harmful organisms.

Water Distribution Systems (1 of 5) Water mains deliver water from treatment facilities to the end user. Include pumps, storage tanks, and reservoirs

Water Distribution Systems (2 of 5) Water pressure Generally 20-80 psi Hydrant pressure should not drop below 20 psi. Usually produced by pumps (directly or indirectly)

Water Distribution Systems (3 of 5) Water pressure may also be produced by gravity. Gravity-feed system Elevated water storage towers

Water Distribution Systems (4 of 5) Water mains typically follow a grid system. May have dead-end mains Water enters from only one direction. Limited available water supply Multiple hydrants rob water from each other.

Water Distribution Systems (5 of 5) Water main valves Control valves: located throughout system to shut down sections Shut-off valves: used to shut off water flow to individual customers and hydrants

III. Fire Hydrants 60 minutes

Fire Hydrants Provide water for firefighting purposes Installed on both public and private water systems Consist of an upright steel casing attached to the underground distribution system

Dry-Barrel Hydrants Used in cold climates Hydrant valve is located at the base of the barrel and allows water to flow into the hydrant. Water flows into the hydrant only when it will be used. Opened by turning nut on top of hydrant

Skill Drill 15 1 Operating a Fire Hydrant Step 1: Remove the cap from the outlet you will be using. Step 2: Quickly look inside the hydrant opening for foreign objects. (Dry-barrel hydrant only.)

Skill Drill 15-1 Operating a Fire Hydrant Step 3: Check to ensure that the remaining caps are snugly attached. (Dry-barrel hydrant only.) Step 2: Attach the hydrant wrench to the stem nut. Check for an arrow indicating the direction to turn to open.

Skill Drill 15-1 Operating a Fire Hydrant Step 5: Open the hydrant enough to verify flow and flush hydrant. (Dry-barrel hydrant only.) Step 6: Shut off the flow of water. (Dry-barrel hydrant only.)

Skill Drill 15-1 Operating a Fire Hydrant Step 7: Attach hose or valve to the hydrant outlet(s). Step 8: When instructed, turn the hydrant wrench to fully open the valve.

Step 9: Open slowly to avoid pressure surge. Skill Drill 15-1 Operating a Fire Hydrant

If water is left standing, it may freeze. After each use, water drains out of barrel. When hydrant is fully open, drain is closed. When hydrant is fully closed, drain is open. Partially open hydrant allows water to escape under pressure, thru drain. Causes erosion of soil around hydrant Reduces hydrant flow

Skill Drill 15-2 Shutting Down a Hydrant Step 1: Turn the wrench to slowly close the hydrant valve. Step 2: Drain the hose line. Slowly disconnect the hose from the hydrant outlet.

Skill Drill 15-2 Shutting Down a Hydrant Step 3: Leave one hydrant outlet open until the hydrant is fully drained. Step 4: Replace the hydrant cap.

Wet-Barrel Hydrants Used in locations where temperatures do not drop below freezing The barrel always has water in it. Each outlet is individually controlled. Additional lines can be added while water is flowing.

Location of Hydrants Located according to local standards and national recommended practices Every 500 in residential areas; every 300 in high-value areas Every intersection; mid-block when over set distances Based on occupancy, construction, and size of the building

Types of Hydrant Pressure 1 of 2 Static pressure - Pressure in the system when water is not moving Normal operating pressure - The amount of pressure in the system during a period of normal consumption

Types of Hydrant Pressure 2 of 2 Residual pressure - The amount of pressure that remains in the system when water is flowing. Flow pressure - Measures the quantity of water flowing through an opening during a hydrant test

Of the 4 types of Hydrant Pressure above Static and Residual are the two most important.

Inspecting and Maintaining Fire Hydrants Check for visibility and access. (1 of 2) Check for exterior damage. Ensure barrel is dry and free of debris. Ensure all caps in good working order. Open valve for water flow and remove debris. Shut down and ensure proper draining.

Inspecting and Maintaining Fire Hydrants (2 of 2) To clean threads, use a steel brush. To remove burrs on threads, use a triangular file. Replace cracked, broke, or missing caps and/or gaskets. Lubricate as recommended by manufacturer.

Testing Fire Hydrants Fire-suppression companies are often assigned to test the flow from hydrants in their districts. Testing procedures are simple, but an understanding of hydraulics and attention to detail are required.

Flow and Pressure (1 of 3) Flow is the quantity of water moving through a pipe, hose, or nozzle measured by its volume, usually in gallons per minute. Pressure is the energy level measured in pounds per square inch

Flow and Pressure Static pressure: (2 of pressure 3) when no water is moving Measured by placing a gauge on a port with no water in the system moving Normal operating pressure: pressure during a period of normal consumption Measured by placing a gauge on a

Flow and Pressure (3 of 3) Residual pressure: Amount of pressure that remains in the system when water is flowing Flow pressure: Measures quantity of water flowing through an opening during a hydrant test Measured with a Pitot gauge

Hydrant Testing Procedure (1 of 3) Requires: Two adjacent hydrants Pitot gauge Outlet cap with a pressure gauge

Hydrant Testing Procedure (2 of 3) Place cap gauge on an outlet of first hydrant. Open hydrant valve and record pressure reading as the static pressure. At second hydrant, remove cap and open valve.

Hydrant Testing Procedure (3 of 3) Place Pitot gauge in stream and record as Pitot pressure. At the same time, record residual pressure at the first hydrant. Calculate or use look-up tables to determine flow.

IV. Rural Water Supplies 60 minutes

Rural Water Supplies Residents of rural areas usually depend on wells or cisterns to provide water. No hydrants in these areas, so water must be obtained from other sources

Static Water Sources (1 of 2) Static sources include: Rivers or streams Lakes, ponds, oceans Reservoirs Swimming pools Cisterns

Static Water Sources (2 of 2) Must be accessible to a fire engine or portable pump Is there a road or hard surface within 20 feet? May have a dry hydrant permanently installed

Mobile Water Supply Apparatus Also known as tankers or water tenders Designed to carry water to the fire Generally carry 1,000-3,500 gallons May be used to pump water directly into attack engine

Portable Tanks (1 of 2) Carried on fire apparatus to be set up at the fire scene Typically hold 600-5,000 gallons of water Tankers are used to fill the portable tanks. The attack engine drafts from the tanks.

Portable Tanks (2 of 2) Dump valves on the tankers allow them to off-load up to 3,000 gallons per minute.

Tanker Shuttles Used to deliver a large volume of water over a long period of time Number required depends on Distance between fill site and fire Time it takes to dump and to reload Flow rate required at the fire scene Eliminate delays at fill site and dump site

V. Summary 5 minutes

Summary Municipal system has three components: water source, treatment plant, and distribution system. Hydrants may be wet-barrel or dry-barrel. Inspection of hydrants is needed annually. Testing is done to determine maximum flow availability. Rural water supply utilizes fill sites, tankers, and portable tanks.

End