OTF Oil Fired Pool Heater
|
|
|
- Martin Kelly
- 9 years ago
- Views:
Transcription
1 OTF Oil Fired Pool Heater Installation Operation Maintenance Manual
2 Service Policy Congratulations on the purchase of your new pool heater. In order to maintain peak performance of your pool heater it must be winterized at the end of the season, prior to the onset of freezing weather. The burner and boiler must also be serviced annually. Servicing of your appliance must be performed by a qualified technician. You should utilize a qualified heating and pool equipment technician familiar with your installation to manage your heater and perform periodic maintenance. Proper care and maintenance of your pool heater will allow you to enjoy the benefits of your pool heater as well as extend its useful life. In the event that your serviceman encounters difficulty with the pool heater, they should contact the distributor from which the product was purchased. The distributor will contact the local manufacturer s representative for assistance. General Information 1. Read all instructions and review all diagrams prior to proceeding with installation. 2. Instructions and diagrams are intended only as guidelines. Installations must conform with all applicable national, state and local codes. Additional guidelines are available from National Fire Protection Association (NFPA), American Society of Mechanical Engineers (ASME) and Building Officials, Code Administrators (BOCA), National Electric Code (NEC), Uniform Mechanical Code (UMC) and Uniform Plumbing Code (UPC). I. Installation Instructions Message to the Installer. Read these instructions completely before installation. Discuss the following NOTES with the person who will maintain the system after it is installed. Failure to follow these instructions may result in damage to the equipment and void the warranty. Take special care to note these important warnings. 1
3 An adjustable by-pass around the heat exchanger is required. The bypass is an important and necessary component to obtain optimum performance. See the piping photograph and instructions for adjusting the bypass. The boiler section must be filled with fresh water, not chlorinated pool water. See filling instructions. The pool heater may not be used for salt water pools. Use of the pool heater in a salt water pool will void the warranty. The use of antifreeze in the boiler section is not recommended because it reduces heat transfer to the coil. Winterizing: If the pool heater is installed in an area known to have freezing temperatures, the boiler must be completely drained and the heat exchanger coil removed, drained and stored in a warm place during periods of freezing temperatures. The heat exchanger coil is not warranted for failure due to freezing. The boiler must be placed on a level concrete floor or pad. Failure to level the boiler may result in poor heat transfer due to air pockets in the boiler. I. Locating the Heater 1. Before uncrating the unit, prepare the location for the boiler. It should be placed upon a good level concrete floor or pad. Care should be taken to locate the unit for easy accessibility. The pool heater should not be located near or under living spaces or windows. Maintain the following clearances to combustible materials: Front: 24 inches Back: 24 inches Sides: 12 inches Windows: 3 feet In addition, the air openings in the cabinet must have adequate clearance to allow for sufficient air intake to the burner. Un-crate the unit as close to its permanent location as possible to prevent handling damage 2
4 II. Connections 1.Remove the front jacket panel and install the expansion tank which is shipped loose to avoid damage during shipping. The vent cap, coil cover and pool piping instrument sensor T also shipped loose. All other components are installed at the factory. See photograph and diagram of piping for locations. Do not run any piping along the front access panel of the heater as they may interfere with servicing. The tapings for connecting the unit to the pool circulation lines are at the back of the heater. These connections are 1 ¼ inch npt. Connections should be made as per the piping photograph at the end of this manual. Copper piping must be run from the coil inlet and outlet down to below the bottom of the coil flange. The metal piping will act as a heat trap and reduce possible damage to the plastic pipes from overheating. Install the 1 ¼ x1 ¼ x ¾ npt Tee (PROVIDED) at the coil where the piping from the pool filter/pump enters the coil. Install unions in the vertical piping as close to the heat exchanger coil as possible but beyond the edges of the coil plate so they can be easily removed for service and winterizing. Make the transition to plastic pipe on the other side of the metal unions near to ground level. An adjustable bypass around the heat exchanger is required. The bypass is important and necessary to obtain optimum performance and protect the coil. See piping photograph at the end of this manual. 2. The cable from the pool thermostat control is routed from the control inside the jacket to the jacket opening for the coil. Remove the copper well from the end of the sensor cable. Remove the sensor from the well. Apply pipe dope to the threads of the well and install it in the T. Install the sensor in the well and connect the cable to the well. 3. Do not re-install the front jacket panel until the boiler is filled and the by-pass is adjusted. III. Filling instructions NOTE The pool heater is an indirect heater using primary water in the boiler shell to act as a heat transfer medium to the pool water flowing through a separate all copper and bronze heat exchanger coil. The pool heater, or boiler section, must be filled with fresh city water. Do not fill with chlorinated water or water from the swimming pool. 1. Do not turn on electrical power to heater until boiler is properly filled with water. 3
5 2. Connect the female end of a garden hose to the hose adaptor of the heater drain valve. 3. Open the air vent at the top left side of the boiler recirculation piping. See photographs of piping at the end of this manual. 4. Turn on water and open the drain valve, allow water to flow into boiler section. Do not fill rapidly. Listen to the air venting from the vent valve. 5. When air stops coming out of the boiler air vent shut the vent valve. Continue to fill until the pressure gauge reaches approximately 2 PSI. 6. Close the drain valve and disconnect the hose. If you exceeded 10 psi in step 5, reduce the pressure in the boiler by draining water from the drain valve. 7. After the boiler cycles a few times it may build pressure till air in the water is driven off. If this happens reduce pressure from the drain valve to approximately 8 psi when the boiler is hot by draining from the drain valve through a hose to a safe discharge location for hot water. When the boiler is cold the pressure should be approximately 2 psi. If the boiler relief valve lifts during initial heat-up or after a few cycles, check the charge on the expansion tank. The expansion tank must be charged with air to 12 psi to allow for expansion of water in the boiler. If the expansion tank is not charged, the relief valve on the boiler may lift when the boiler is heated to operating temperature. 8. Follow the procedure for setting the bypass. IV. By-pass Set-up The boiler uses water in the boiler to transfer heat to the pool water in the coil. To ensure optimum heat transfer and to prolong the life of the coil it is important to adjust the flow rate through the coil using the procedure that follows. Excessive flow through the coil may result in erosion and premature failure of the coil. A flow rate of approximately 12 gpm is desired. 1. In order to properly adjust the flow rate through the system, follow these steps: A. Differential Pressure Method (1). With the bypass valve fully open take a pressure reading at the pressure gauge on the pool filter. (2). The pressure reading with the bypass valve fully open is the baseline pressure. 4
6 (3). Slowly close the bypass valve so that the pressure increases. (4). Stop when pressure reaches 2 to4 psi above the baseline at the filter. Mark the position of the bypass for future reference. B Differential Temperature Method (1). Set the by-pass using the Differential Pressure Method noted above. (2). Start the burner and wait until the boiler temperature is about 150 degrees F on the pressure temperature gauge. (3). Check the pool temperature and outlet temperature from the coil. (4). Slowly close the bypass until the difference between pool temperature and outlet temperature from the coil is between 14 and 20 degrees. 2. Pool temperature control should be set at the desired temperature. 3. Operate the burner in accordance with burner operating instructions. V. Flue connection and Coil Cover: 1. The OTF heaters are provided with an outdoor vent cap to be installed directly on top of the cabinet at the flue outlet. This vent cap provides for a waterproof unit as well as proper control of combustion draft. The vent cap is shipped loose. If the boiler is located in a pool house use standard flue piping to vent the flue gases outside of the pool house. 2. A coil cover is also shipped loose and should be installed to protect the opening around the coil from the weather. VI. Winterizing The Heater: If the pool heater is installed in an area known to have a freezing climate it is necessary to completely drain both the primary boiler and remove, drain and store the heat exchanger coil and gasket in a warm dry place. (The unions installed in the copper piping to and from the coil will facilitate removal of the coil.) Connect a hose to the boiler drain at the bottom of the boiler section. Open the vent valve at the top of the boiler, as well as the drain valve and drain the boiler section completely. Note: The heat exchanger coil is not warranted for failure due to freezing. Drain the coil completely. Removing all of the water requires removal of the coil from the boiler and tilting the coil back and forth until water in all of the sections of the coil is drained. Remove scale from the exterior coil surfaces using a scale remover such as CLR. Store the coil in a warm dry location during the winter months. Inspect the coil gasket for signs of cracking or wear. Order a new gasket if necessary. Cover the opening of the coil in the heater with heavy duty aluminum foil to prevent debris from falling into the boiler during the winter months. 5
7 VII. Spring Start-Up Installing the heat exchanger coil: Reinstall the heat exchanger coil after the last chance of freezing weather. Note: The heat exchanger coil is not warranted for failure due to freezing. Remove the foil covering the coil opening. Inspect the coil gasket and install a new gasket if necessary. Carefully install the coil in the opening. Make sure that the nuts are tightened evenly to avoid cocking the coil plate. Follow the filling instructions and start-up and operating instructions. Check that the heat exchanger coil nuts are tight before starting the burner and again after the boiler is at operating temperature. VIII. Start-Up and Operation A. Start-up: 1. Make sure the electrical power is turned off. 2. Check the oil burner ignition electrodes carefully and adjust if necessary referring to the oil burner manual instructions. 3. Check to be certain that the oil tank is full. 4. Be certain that the boiler is filled with water as per the filling instructions. 5. Check the pressure on the expansion tank is 12 psi. The expansion tank must be charged with air to 12 psi to allow for expansion of water in the boiler. If expansion tank is not charged, the relief valve on the boiler may lift when the boiler is heated to operating temperature. 6. Turn on pool filter pump. 7. The limit control is factory set at 175 F and is not adjustable. 8. Start the oil burner in accordance with the burner manufacturers Operating Manual. Allow the burner to operate continuously for at least 15 minutes. Then, using a combustion analyzer adjust burner in accordance with burner manufacturer s instructions. Draft readings over the fire should be in the range from zero and negative Final CO2 reading should be approximately 10%. 6
8 9. The recirculation loop located on the heat exchanger above the burner re-circulates water from the bottom of the boiler to the top whenever there is power to the boiler. Re-circulation enhances heat exchange efficiency. An automatic vent valve located in the top left section of the piping automatically vents gases from the system if they come out of solution. Trouble Shooting 1. Motor does not run. a. Check fuses and power to heater. b. Set pool temperature control and boiler temperature limit to highest setting. c. Reset primary control. Push red button. Reset button should only be pushed one time! d. Check for defective temperature controls by jumping the controls one side at a time. e. Check for power to motor. f. Ensure that boiler is filled and pressurized with water. (The low water cutoff will interrupt the electrical circuit to the burner if the boiler water level is low.) 2. Motor runs -no fire. a. No oil in tank. b. Dead or plugged burner nozzle. c. Blocked oil line. d. Loose transformer connections or defective ignition transformer. e. Inspect electrode settings and insulators. f. Check fuel pump pressure. 3. Burner fires shuts down a. Defective cad cell. b. Dirty cad cell. c. Defective primary control d. Improper burner adjustment. 4. Smoke coming out of flue a. Clogged nozzle. b. Dirty fan or air handling parts. c. Improper burner adjustment. 5. Cycling on or off: a. Differential between pool setting and high limit too close. b. Remote pool sensing bulb in outlet water piping instead of inlet water piping. c. Bypass not adjusted properly. Follow bypass adjustment procedure. 6. Boiler relief valve lifts. a. Expansion tank is not charged. Cool boiler to ambient temperature, re-charge expansion tank to 12 psi and follow filling procedure. 7
9 b. Pool coil is leaking domestic water into boiler. Replace coil. c. Pool temperature sensor not inserted completely in well. IX. Care and Maintenance 1. Heat exchanger: The tubular portions of the heat exchanger should be cleaned annually or at startup each heating season. a. Remove the cabinet top. b. Remove the flue collector top. c. Remove all baffles from fire tubes. d. Brush clean the flue ways with a 2 inch soft brush and vacuum the unit carefully. e. Reassemble the unit. 2. Oil filter: the oil filter cartridge should be replaced annually. 3. Oil burner: a. Thoroughly brush clean the burner fan blades. Proper combustion air delivery is only possible when fan blades are clean. b. Clean nozzle assembly and all other air handling parts. c. Check spacing and condition of electrodes. Adjust or replace as necessary. d. Nozzle should be replaced if nozzle does not perform according to the prescribed conditions under burner adjustments. Replace it with only the specified type. 4. Gaskets: Carefully tighten nuts on the pool heat exchanger flange to prevent gasket leaks. Deterioration due to gasket leaks will void the warranty. Specifications OTF Model Gross Input BTU/hr 140, , , ,000 Gross Output BTU/hr 109, , , ,000 Flue Pipe Diameter Firing Rate GPH Width ¼ 26 ¼ Length Height 38 ½ 38 ½ Standard Equipment: Aluminum jacket with integral vent cap and coil cover, dry base boiler with cement combustion chamber installed or wet leg boiler, expansion tank, theraltimeter, burner, pool and limit control, low water cutoff, boiler relief valve, indirect pool heating coil with 1 ¼ tappings. 8
10 Homeowner Information WARNING Even though the vent cap is 40 inches above the ground, keep small children away from your pool heater. Record the boiler serial number for future reference: Boiler installed by: Name Address: Phone: For Boiler Service Contact: Name Address: Phone: Service Information: To avoid unnecessary expense and inconvenience your pool heater must be winterized prior to freezing weather and cleaned and serviced annually by a qualified service technician. If any problems occur check the following before calling a service technician. 1. Check to be sure there is fuel in the tank and if there is a fuel shutoff valve it is open. 2. Make sure the power switch is turned on. 3. Check to see if the desired pool temperature setting is greater than the current temperature of the pool. 9
11 Swimming Pool Heater Warranty The heat exchanger of the Swimming Pool Heater is warranted against defects in material and workmanship for a period of 5 years from the date of installation. The indirect heat exchanger coil (Copper pool coil) is guaranteed for 1 year against defects in material and workmanship from the date of installation. All other components are guaranteed to the extent of the manufacturer s warranty. This warranty does not cover: 1. Components of the system supplied by others. 2. Workmanship of the installer. This warranty does not assume any liability of any nature for unsatisfactory performance caused by improper installation. 3. Shipping damage. Any evidence of shipping damage must be reported to the shipping company immediately and a claim filed. Do not install the boiler. 4. Improper adjustment, control settings, care, maintenance or failure to follow installation instructions provided with the boiler. 5. Defects resulting from freezing, excessive pressure, temperature or leaks at water connections or any similar cause. 6. Any installation that has been modified, neglected, altered, tampered with, vandalized, misused subjected to accident, fire, flood or other casualty. 7. Damage due to deterioration and failure to maintain the boiler. 8. In and out charges. 9. Labor. This warranty extends only to the first purchaser at retail and only when the boiler is in the original installation site, which must be within the continental limits of the United States of America. Implied warranties of fitness for a particular purpose and merchantability shall be limited to the duration of the express warranty. Manufacturer expressly disclaims and excludes any liability for consequential or incidental damages for breach of an express or implied warranty, except as otherwise provided by state law. This warranty gives you specific legal rights. You may have other rights that vary from state to state. 10
12 Service and Set-up Records Initial Set-up Second Third Fourth Fifth Date Model Firing Rate Fuel Pump Pressure CO2 Smoke Gross Stack Draft over fire Replace Filter Clean Pump Filter Inspect Coil Gasket Check for Brush Clean Flue Tubes Vacuum Chamber/Flue Tubes Clean Blower Wheel Check/Set Electrodes 11
13 Coil Plate Union Sensor Cable Sensor Fitting Union Supply To Pool Bypass Valve Return From Pool OTF Suggested piping from coil to pool. Instrument sensor T provided with boiler. All other piping not supplied. Note copper piping to and from coil to act as a heat sink transitions to PVC with full flow bypass valve. Sensor T location is noted. Unions will allow easy disassembly and removal of coil prior to freezing weather. Note that pool water to the coil is to the sensor T side of the piping in the top of the coil and return to pool is from the bottom of the coil. 12
14 Slide panel allows for easy access to the boiler control. Pool temperature is set using a dial located at the bottom of the control on the outside of the box. Temperature Pressure Gauge Expansion Tank Circulator Low Water Cutoff Thermostat Control Drain Valve OTF with jacket removed to show burner, boiler control, boiler control sensor and cable, low water cutoff, temperature pressure gauge, fill/drain valve, expansion tank, recirculation piping and circulator. 13
15
16 MET-7444
LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459
SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER
INSTALLATION & MAINTENANCE MANUAL TURBOPOWER GAS, OIL & GAS/OIL WATER HEATER Installation and service must be performed by a qualified service installer, service agency or the gas supplier. Oil Gas/Oil
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
INSTANT HOT WATER RECIRCULATING SYSTEM
INSTANT HOT WATER RECIRCULATING SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS Save manual for future reference MODEL 500800 Warning Please read carefully before proceeding with installation. Your failure
What you can expect from your Solar Hot Water System
Owner s Manual Your Solar Hot Water System Thank you for your investment in the FAFCO Solar Hot Water System. Since 1969 our goal has been to design, test, and produce solar heating systems that save you
Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:
Seaward Products WATER HEATERS OWNER S MANUAL Serial Number: IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, basic safety precautions to reduce the risk of fire, electrical shock,
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
Boiler and Burner Cleaning and Servicing Specifications
Boiler and Burner Cleaning and Servicing Specifications The Town of Groton of Public Works Department is requesting bids to provide manufacturers recommended maintenance, repairs and emergency service
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS
Sunshine Pool Products, LLC Manufacturer of Quality Pool & Spa Products 902 W 2010 S, Syracuse, Utah 84075 USA Voice: 801-825-4523 Website: www.sunshinepool.com Email: [email protected] POOL SUNSHINE
Select Radiators Installation Guide
Select Radiators Installation Guide Table of Contents Informational Symbols...3 Before You Begin...4 Select Rough-In... 5 Connection Installation...6 Optional Piping Arrangements...7 Conventional Wall
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS with the 263/742 Logix Control Valve June 2010 Table of Contents Page No.
Electric Water Heater
Electric Water Heater Operation and Installation Manual (LIMITED WARRANTY AND TANK REPLACEMENT POLICY) The following information should be noted at time of installation and retained for future reference.
Installation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit
I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit IMPORTANT: These installation instructions are meant to be used as a guide for woodstove owners and
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
Air Conditioner Water Heater Model ACWH18
Air Conditioner Water Heater Model ACWH18 Installation Guide IMPORTANT! READ THIS FIRST! Commissioning of this unit must be done by a licensed HVAC technician. Commissioning includes making the electrical
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
INDIRECT WATER HEATER. Installation and Operating Instruction Manual
INDIRECT WATER HEATER Installation and Operating Instruction Manual Maximum supply temperature to heat exchanger must not exceed 180 F (82 C). Safety Warning: Indirect water heaters are heat-producing
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS
INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS HEAT-FLO HOT WATER STORAGE / BOOSTER TANKS MODELS 30-ST, 40-ST, 40L-ST, 60-ST, 60L-ST, 80-ST, 115-ST, 80-ST-C, 115-ST-C FOR SINGLE TANK INSTALLATIONS For
Installation and Operating Instructions Installation Instructions for SS EPE-316L Series
INSTR3010 0406 Installation and Operating Instructions Installation Instructions for SS EPE-316L Series Congratulations on your purchase of this Aqua-Pure high flow, single housing filtration system. This
Tankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve
Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE. DESCRIPTION
ENGINE COOLING SYSTEM
ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
Miami Heat Pump HP Series Installation Guide
CAUTION- THIS UNIT IS FOR INDOOR USE ONLY!! WARNING BEFORE ANY INSTALLATION OR MAINTANCE IS STARTED PLEASE READ COMPLETE INSTLLATION GUIDE. INSTALLATION START-UP AND SERVICE INSTRUCTION- The HP Water Source
GAS SAFETY PRECAUTIONS
GAS SAFETY PRECAUTIONS Instructions on what to do when a user smells gas can be obtained from the local gas supplier. These instructions must be posted in a prominent location where the unit is to be operated.
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
PLP - TERMS AND CONDITIONS
PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia
Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information
Steam Humidifier Model 800 Residential Steam Humidifier Owner s Manual Includes Safety & Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Safety Cautions...
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Evaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures
KEY CONCEPTS 1. Identify tools for plumbing 2. Location of shutoff valves for the main and individual fixtures 3. How water is supplied to your home 4. How waste water is removed and treated 5. Common
Utility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
High efficiency, cast-iron gas boiler
SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home
Baths of Distinction Inc. 5843 Carrier St St. Petersburg Florida USA 33714 1.866.938.3880. Manufacturers of Classically Styled Vintage Bathtubs
Baths of Distinction Inc. 5843 Carrier St St. Petersburg Florida USA 33714 1.866.938.3880 Manufacturers of Classically Styled Vintage Bathtubs INSTRUCTION & INSTALLATION MANUAL - AIRLINE HEATED AIR BUBBLE
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions
Geyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Installation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK Safety Instructions Installation Warranty IN-LINE SERIES: 2-5 & 7 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON VERTICAL SERIES: 14-20-32-36-52-86-96-119 GALLON KEEP
OWNER S Manual PRINTED IN CANADA 10/2009
OWNER S Manual PRINTED IN CANADA 10/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing
1/3 HP Submersible Sump Pump with Vertical Float Switch
1/3 HP Submersible Sump with Vertical Float Switch Item 68476 Specifications Float Switch Operation Height 7.1 IN. ON / 2.8 IN. OFF Electrical Requirements 120V~ / 60Hz / 7.6A Power Length Maximum Capacity
Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, 1060. Instruction No.
Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, 07647 USA PIPING GUIDE GF-115-P Modulex Gas Fired Boiler Systems Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909,
Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00
E Refrigerant Charging Unit ICOGD 020AH1000 Operating Manual FR.8.2.4-09 İ-COLD 12.03.2014 Rev. 00 Contents Technical Specifications... 20 Safety... 21 A/C System... 22 Components... 23 Control Panel...
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Installation and Operating Instruction Manual
Electric Mini Tank Water Heaters CMT-1.3 CMT-2.5 CMT-4.0 CMT-ST70 Tempering valve Optionally available Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General
Dealer Sales & Service Guide
Analog Models w/thermostat or Timerstat Heat Siphon Not Starting 1 BREAKER TRIPPED - Check Breaker Box for correct size breaker Breakers: EX; Domestic model 2.25hp (20amp) 3.25hp (40amp) 5hp (50amp) check
MODEL 300505 INSTALLATION INSTRUCTIONS
WWW.BURCAM.COM 2190 Boul. Dagenais West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 [email protected] Your pump has been carefully packaged at the factory to prevent damage during shipping.
NOTE! READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING.
INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS PROPANE GAS ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY. GAS LOGS MUST BE INSTALLED BY PERSONNEL QUALIFIED FOR INSTALLING GAS APPLIANCES.
GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.
Pellet Heater Owner's Manual Installation and Operating Instructions Please read this entire manual before installation. Save these instructions. SAFETY NOTICE HEATER MUST BE PROPERLY INSTALLED AND MAINTAINED
ASME Packaged Indirect Fired Water Heater
Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Laddomat 21-60 Charging unit
Laddomat 21-60 Charging unit User and installation instructions NOTE! Diagrams in this brochure only describe connection principles. Each installation must be measured and carried out according to the
CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual
CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual Goodway Technologies Corporation 420 West Avenue Stamford, CT 06902-6384 (203)359-4708 Sales: 1-800-333-7467 Customer Service: 1-800-370-2855
Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping
Instruction Sheet 102-140 Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping Plant I.D. 001-1024 EFFECTIVE: November
SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE
Eemax Inc., 353 Christian Street, Oxford, CT 06478 1 E ema X SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE WARNING
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause
Electric Mini Tank Water Heaters WM-2.5 & WM-4.0
Electric Mini Tank Water Heaters WM-2.5 & WM-4.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 2 Technical Data 3-4 General Information 5 Technical Description
Central Air Conditioner
Central Air Conditioner USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW RESIDENTIAL AIR CONDITIONER NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME
ELECTRIC/DIESEL FIRE PUMP CHECK LIST
BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
Installation Instructions - For the following HEATER model numbers: 200, 300, 400, 500 Series Hydronic Heaters
Marine Heater Installation Instructions - For the following HEATER model numbers: 200, 300, 400, 500 Series Hydronic Heaters Approximate Installation Time: 3-5 Hours Tools Required: #2 Phillips Screw Driver;
Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW
Installation, Operating and Maintenance Instructions 90/4.5.5 Rev. 0 Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW Table of Contents SECTION I... 2 INSTALLATION...
THREE. Heating and Cooling
THREE Heating and Cooling 17 Condensation Drain Line The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. If your unit is located in the attic,
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
LOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series
Owner s Service Manual 503 and 504 Series FLUSHMATE FLUSHOMETER - TANK SYSTEM 503 504 FLUSHMATE A Division of Sloan Valve Company 30075 Research Drive New Hudson, MI 48165 800-533-3460 248-446-5300 http://www.flushmate.com
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Owner s Manual. Pelican Custom Premium WHWF 1865/2162
Owner s Manual Pelican Custom Premium WHWF 1865/2162 Page 2 Copyright 2013 Enviro Water Solutions Inc. All rights reserved. All information contained herein is the property of Pelican Water Systems. Pelican
heating 3 & cooling heating and cooling 2010 PulteGroup, Inc. All Rights Reserved.
3 & cooling 17 heating 2010 PulteGroup, Inc. All Rights Reserved. condensation The line that drains condensed moisture away from your heating and/or cooling unit needs periodic maintenance. Air conditioning
Techtanium Solar Indirect Water Heater Instruction Manual
To the Installer: Please attach these instructions next to the water heater. To the Consumer: Please read these and all component instructions and keep for future reference. Techtanium Solar Indirect Water
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+
Mini Tank water heater Electric undersink Water heaters GL 2.5 - GL 4 - GL 6+ IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric
Mini Tank. Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0. Installation and Operating Instruction Manual
Mini Tank Electric Mini Tank Water Heaters WM-1.0 WM-2.5 WM-4.0 WM-6.0 Installation and Operating Instruction Manual Table of Contents Important Safety Instructions 3 General Information 3/6 Technical
Factory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Condensing Water Heater Operation Manual Model NPE-180A/ 210A/ 240A NPE-180S/ 210S/ 240S * Lead Free Keep this manual near this water heater for future reference whenever maintenance or service is required.
Installer s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000
Multi-Pure Whole House Water Treatment System Installation, Operation and Maintenance Manual Multi-Pure Model TO15000 Warning Please read manual carefully before proceeding with installation. It is recommended
G26 Corp. 9721-L11 Revised 07-2001 LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS
Service Literature G26 SERIES UNITS G26 series units are high-efficiency upflow gas furnaces manufactured with DuralokPlust aluminized steel clamshell-type heat exchangers. G26 units are available in heating
USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model # 900172
Model # 900172: Page 1 USER MANUAL Bottom Loading Bottled Water Dispenser Model # 900172 TO REDUCE THE RISK OF INJURY AND PROPERTY DAMAGE, USER MUST READ THIS MANUAL BEFORE ASSEMBLING, INSTALLING & OPERATING
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
Please keep this manual for f uture reference.
GAS WATER/AGUA Congratulations! You've just purchased a new Marey Portable tankless water heater and will soon begin to enjoy the benefits of going tankless. Take the time to thoroughly read and understand
Line to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.
TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY. Table of Contents Page No. 1. Turn the main power switch located on the back-side
MASTER. Water Conditioning Corp. MBA-10/13 FILTERS with the 253/742 Logix Control Valve. Installation and Operation Manual. www.masterwater.
MASTER Water Conditioning Corp. www.masterwater.com Installation and Operation Manual MBA-10/13 FILTERS with the 253/742 Logix Control Valve June 2010 Table of Contents Page No. Topic Description 1 Model
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
S Series. Installation Operation Maintenance Manual. www.thermodynamicsboiler.com
S Series Installation Operation Maintenance Manual www.thermodynamicsboiler.com Thermo-Dynamics Boiler Company ROUTE 61 P.O. BOX 325 SCHUYLKILL HAVEN, PA 17972 (570) 385-0731 FAX (570) 385-5304 Service
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION