TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12



Similar documents
Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Specifications. Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT:

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Sample - No Commercial Use

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Secondary Unit Substations

TorqPlus TM Electric Valve Actuators and Controls

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

MCC Ratings. Voltage Rating

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

INSTALLATION INSTRUCTIONS

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Oil and Coolant Circulating Heating System. Model - OCSM

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

8146/5 Series Breaker Panelboards

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

TS93 EMR T/PT/TDE. Surface applied door closer

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

Variable Transformers Product Design & Engineering Data

MDT5N25 & MTD5N40 SERVICE PARTS

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Diesel Engine Driven Generators Page 1 of 6

WHOLESALE DIRECT INC WEST 65TH STREET

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

Glossary of Common Crane Ter ms:

Plug-in relays Mini ISO relays

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Electric Rotary Actuator - On/Off or programmable control actuator

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Distribution Dry Type Transformers

RAY-MAX Integrated Solar Power Strip

IRRIGATION PUMPING Table of Contents - Section 900

THE ADVANTAGES ARE YOURS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Equipment: Power Supply, DAI, Synchronous motor (8241), Electrodynamometer (8960), Tachometer, Timing belt.

Instruction Bulletin. MCS025 Sync-Check Module Installation Sheet

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

FIREDEX Conventional Fire Panels

BB -508L/509L INSTALLATION MANUAL LATTICE BOOM CRANES. Greer Company Crane Systems. Greer Company

Maxi-Stamper. 200 to 1,000 Tons STAMPING OUT DOWNTIME

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Rugged & Reliable Power Connections

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

Contractors Guide Central Inverter System Installation

Wiper Motor Marinco 2.5. Installation Instructions

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Circuit Breakers. NRC Series. NRC Series

MULTI-BEAM LS10 Light Screen System

VEHICLE SPEED CONTROL SYSTEM

HS5D. Miniature Interlock Switches First in. Head Removal Detection Function for Safer Performance. First in. the Industry.

AFE424 SERVICE PARTS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

A1000 Cheat Sheet (Open Loop Vector)

Cooling system components, removing and installing

Electric Panel Pump Control System. Operation, Maintenance and Installation Manual

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

SECTION LOW VOLTAGE LIGHTING CONTROLS

GE Power Controls. MiniFORM Switchboards

GLOLAB Two Wire Stepper Motor Positioner

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

HERZ-Thermal Actuators

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

ILISC515-A Shift Interlock (Manual Lift Door) 2015 Ford Transit, 3.7L and 3.5L

TABLE-TYER / TABLE-TYER SS POWER STRAPPING MACHINES 04/12/07

PAC1 Door Access Controller

MCR1900 Media Converter 19-Slot Chassis

ETZGAR CONVEYOR COMPANY Controls Section v12.05

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Bolted contact switches. Pringle switches

Medium Voltage Motor Control Assemblies

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Architectural Specifications* MODEL HDE

Transcription:

Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com

Cleaveland/Price Type TP-C2 Motor Operator The Cleaveland/Price TP-C2 is a high torque motor operating mechanism designed to operate disconnect switches requiring torsional drive. The TP-C2 enables remote control of the disconnect switch as well as local electrical and manual operation. Manual operation is by handcrank or optional swing handle. The TP-C2 easily mounts to any structure and is interchangeable with the Cleaveland/Price GHC wormgear operator. The TP-C2 is the culmination of years of experience and input from users and incorporates improvements and features most desired by the electrical power industry. The motor operator is simple and user friendly. All internal components of the motor operator are accessible through the front door, eliminating the need for removable side panels. The motor control circuit, auxiliary switches, and heater are factory wired to terminal blocks located at the front of the operator enclosure. Terminal blocks for customer wiring are set at an angle for ultimate accessibility. Connecting wires are clearly marked for identification. The solid state controls switch heavy DC motor currents without erosion of relay contacts. Wiring is modularized into three groups: auxiliary switch contacts, motor, and control circuits. The motor and control circuits are connected through heavy-duty pin connectors. This modular approach allows the quick changing of any component and the addition of selected accessories. Fuses for the motor, control circuit, and heater are conveniently located at the front of the enclosure. The fuses are of the disconnecting type and provide an open gap for AC/DC isolation.

External Features 1 Grounding Provision A clamp-on ground strap is provided for grounding the vertical pipe. A grounding lug is provided at the bottom of the enclosure. Decoupler The TP-C2 is equipped with a torque-relief decoupler as a standard feature. When the coupling handle is pulled down, the torque-relief decoupler releases the torsional load from the vertical pipe. No tool or initial manual operation is required to relieve this force and decouple the motor operator from the vertical pipe. The coupling connection is designed so that the vertical pipe can only re-couple to the motor operator in the correct position. An optional swing handle can be pinned to the coupling handle for manual ice chopping operation when the motor operator is decoupled from the vertical pipe. Provision for Padlocking When the vertical pipe is decoupled from the motor operator, the vertical pipe can be padlocked in place with the switch in the open or closed position. The decoupler handle is also padlockable in the coupled position. Pipe Connector The connection between the motor operator and the vertical operating pipe is a clamping device with stainless steel piercing set screws that prevent slippage. The connector can be ordered for either 1½, 2, or 2½ IPS pipe. External Mechanical Stop Rugged mechanical stops are provided to prevent over-travel of the torsional pipe during manual handcrank operation. The stops are built into the motor operator assembly and do not require structure support. The stops are adjustable to the final position of the airbreak switch. Weatherproof Aluminum Enclosure The motor operator enclosure is made of marine grade aluminum for corrosion resistance. The NEMA 3R rating of the enclosure assures weatherproof construction. The enclosure is powder-coated ANSI 61 gray. Custom enclosures are available. Gasketed Door The enclosure door is fully gasketed to prevent entrance of dust or moisture. The door is equipped with a corrosion resistant stainless steel continuous hinge and padlockable handle. An interior pocket is provided for holding instructions and drawings. A clip is provided on the door for storing spare fuses. Removable Conduit Plate An aluminum conduit plate is provided for field drilling and routing of power and control wiring. 2 1 3 2 4 3 6 5 4 5 6 7 7 8 1 8

Local Control Features 1 2 3 4 5 6 Close-Open Switch The close-open switch is a seal-in momentary toggle switch for local electrical operation of the motor operator. The switch has a guard to prevent unintentional operation. Fast stop Button A stop button enables emergency Decoupled stopping and small movements while adjusting the switch. The TP-C2 stop button is appropriately sized and 3 4 positioned for quick stopping. After stopping, an open or close command can 2 be executed. 1 Interlocked Shutter Cover The shutter cover, used to access manual operation, is electrically interlocked with 5 the motor to prevent motor operation while the shutter is raised. Lifting the 6 shutter opens the motor control circuit and allows insertion of the handcrank. Local/Remote Switch The Local/Remote toggle switch permits both on-site and off-site electrical operation of the disconnect switch. In both the local and the remote modes, the control relays are sealed-in to prevent execution of a conflicting command before an open or close operation is completed. TP-C2 in the coupled position Manual Handcrank A handcrank is provided for manual operation. When engaged, the handcrank connects to the wormgear drive. It is conveniently and securely stored on the face of the control panel behind the padlockable door. Auxiliary Switch Contacts The TP-C2 is standard equipped with a four contact auxiliary switch assembly. Two contacts are motor limit switches and two are provided for customer use. Up to fourteen additional contacts can be supplied in the contact assembly. The contacts can be wired as normally open or normally closed. Contacts have a snap action to provide superior interruption of heavy current regardless of the speed of the rotating cams. Interrupting ratings as high as 10 amps on DC inductive circuits are available when specified. The make/break position of each auxiliary switch contact is controlled by an independently adjustable cam. The cams are adjustable through 360 without preset increments. The auxiliary switch assembly is designed for quick and easy adjustment without tools and factory training. Changing the position of a cam does not disturb the position of adjacent cams, and loosening and tightening of set screws on individual cams is unnecessary. Since the motor operator is supplied with a decoupler, a type AS-C or AS-T external auxiliary switch assembly is suggested to assure true remote indication of switch position when the motor operator is uncoupled from the operating pipe. The external auxiliary switch assembly is driven by the vertical operating pipe and not the motor drive shaft. These contacts will always give true indication of switch position.

Internal Features Control Circuit The TP-C2 utilizes an advanced design, state of the art control circuit. Mechanical relays are not used to interrupt motor current. Power interruption is by solid state components with a mechanical relay in series that provides the assurance of an open circuit. Heavy arcing on relay contacts is eliminated - a proven breakthrough for long-term performance. The control circuit provides a sealed-in feature as well as electrically interlocked directional relays. The circuit is intrinsically safe, with no possibility of two contacts closing at the same time. Motor The operator is powered by a maintenance-free, single phase AC/DC reversible motor rated 3/4 hp. Motor overload protection is provided by a fuse. A circuit breaker and thermal overload relay are available as options. Operating personnel are protected from the chain and sprocket drive mechanism by the removable front panel. Drive Mechanism A combination chain drive and wormgear are used to power the output shaft. The chain driven wormgear mechanism is superior to spur gear mechanisms during heavy ice duty. Braking The TP-C2 uses a patented dynamic braking system to provide ultra-precise, repeatable, service-free braking action. Braking is initiated by limit switches or the stop button. With the dynamic braking system, there is no brake shoe or solenoid maintenance. Back-travel of the vertical operating pipe is prevented by the high ratio wormgear drive, which effectively locks the switch in the open and closed positions. Heater A 250 watt anti-condensation heater is provided in the motor operator enclosure. A safety touch guard is provided on the heater. The heater is thermostatically controlled and supplied with a disconnect function via the pullout fuse. An energy-saving humidistat is available as an option. The heater can be powered from a 120 volt or 240 volt source, as specified by the customer. Application Note: Interlocking with a Motor Operator A motor operated switch can be interlocked with other devices. Electrical operation can be prevented by electrically interlocking the motor operator with a circuit breaker. To accommodate electrical interlocking, pre-wired terminal block positions are provided to integrate the circuit breaker auxiliary switch into the motor control circuit. A key interlock may be mounted on the door of the motor operator enclosure to prevent access to the manual handcrank. Alternately, a key interlock may be located on the vertical operating pipe to prevent operation of the switch. An electrically interlocked auxiliary switch must be provided on the key interlock to open the motor control circuit when the key interlock locking bolt is extended. Precaution must be taken when a motor operated switch is provided with a mechanically interlocked grounding switch. An auxiliary switch located on the vertical operating pipe of the ground switch should be specified for interlocking with the motor control circuit of the main switch to prevent motor operation when the ground switch is closed.

Operating Specifications DC AC Catalog Number Rated Voltage Min. Operating Voltage Max. Operating Voltage Torque In-lbs. at Rated Voltage Typical Running Current Locked Rotor Current Operating Time 180 rot. C11A008G22 20,000 5.4 sec. C11A010G01 24 V. 22 V. 31 V. 30,000 40 A. 110 A. 9 sec. C11A008G19 10,000 5.3 sec. 8 A. 55 C11A008G20 18,000 A. 10 sec. 48V. 36 V. 56 V. C11A008G21 20,000 5.4 sec. 20 A. 55 A. C11A010G02 30,000 9 sec. C11A008G01 10,000 2.5 sec. C11A008G02 10,000 5.4 sec. C11A008G03 11,000 5.5 sec. C11A008G04 125 V. 90 V. 140 V. 17,000 6 A. 35 A. 3.5 sec. C11A008G05 20,000 5 sec. C11A008G06 20,000 11 sec. C11A010G03 30,000 9 sec. C11A008G23 20,000 5.4 sec. C11A008G26 250 V. 180 V. 280 V. 20,000 4 A. 11 A. 11 sec. C11A010G04 30,000 9 sec. C11A008G07 10,000 2.5 sec. C11A008G08 10,000 5.4 sec. C11A008G09 11,000 5.5 sec. C11A008G10 120 V. 109 V. 127 V. 17,000 6 A. 20 A. 3.5 sec. C11A008G11 20,000 5 sec. C11A008G12 20,000 11 sec. C11A010G05 30,000 11 sec. C11A008G13 10,000 2.5 sec. C11A008G14 10,000 5.4 sec. C11A008G15 11,000 5.5 sec. C11A008G16 240 V. 208 V. 254 V. 17,000 3 A. 10 A. 3.5 sec. C11A008G17 20,000 11 sec. C11A008G18 20,000 5 sec. C11A010G06 30,000 11 sec. Standard Features Torque-relief decoupler Weatherproof, dustproof, and rustproof NEMA 3R enclosure Padlockable stainless steel enclosure handle Non-cast, adjustable mechanical stops Removable conduit entrance plate Handcrank for manual operation Local/Remote control switch Fast stop button Dynamic braking for electrical stop Fused control and motor circuit Thermostatically controlled 250 watt heater Two auxiliary switch contacts for customer use 4/0 ground strap Ordering Information Customer must specify: Control voltage AC or DC Heater voltage V. Torque rating in.-lbs. Size of vertical operating pipe 1½ / 2 / 2½ IPS Desired optional features

Options Optional Features Additional auxiliary switch contacts Operations counter Switch position indicating lights Weatherproof external GFI Enclosure lamp Customer specified terminal blocks Custom control circuit Swing handle for ice breaking Stainless steel enclosure NEMA 4X rated enclosure Windowed position indicator External auxiliary switch assembly Circuit breaker instead of fuse Internal grounding bus Auxiliary switch assembly with lagging contacts Variable speed control module Operation delay with delay in process indicator Combination Thermostat/Humidistat Other optional features are available. Contact the factory for more information. Operation Delay Module When operating locally, a time delay before switch operation gives utility personnel time to go a safe distance from the switch if necessary. The TP-C2 can be supplied with a time delay module integrated into the front panel control. The delay can be set from 0 to 99 seconds. An LED indicates that an operation delay is in progress. Variable Speed Control Module High kv switches may draw a very large arc when closing in the presence of magnetizing or line charging current or due to coupling capacitance of higher voltage parallel lines. Typically, users want to minimize the amount of arcing time when operating a switch to prevent a phase to phase fault. To accomplish this, the switch must be closed very quickly until an arc horn is engaged and then the speed must be immediately reduced to prevent the switch blade from bouncing open due to impact. Cleaveland/Price offers a variable speed control module that can set two blade speeds for the desired operating affect when closing or opening a switch. Throughout the operating sequence, the full torque rating of the motor operator is maintained regardless of speed setting. Combination Thermostat/Humidistat Typically, heaters are controlled by a thermostat that turns the anticondensation heater on when the temperature reaches dew point. However, the humidity may be low and the heater could be running needlessly. By using a heater control that looks at both temperature and humidity, a more energy efficient system is utilized. Cleaveland/Price offers a combination thermostat/humidistat in motor operators that will turn on the heater only when the temperature and humidity reach the point where the humidity will condense. By using the combination thermostat/ humidistat, utilities can save money and conserve power on their system.

Dimensions Torque Rating A B C D E F 20,000 in-lbs and less 12.00 13.12 4.12 7.75 4.00 4.50 30,000 in-lbs 14.00 15.11 4.75 10.00 6.00 6.00 Dimensions in inches