TECHNICAL ADVISORY BULLETIN



Similar documents
ELECTRIC/DIESEL FIRE PUMP CHECK LIST

CHAPTER. Fire Pumps FIRE PUMP OVERVIEW. Fire Pump Unit Defined. Fire Pump Unit Responsibility

SPP Pumps Inc. Atlanta

Fire Pump Plan Review March 2010

FAIRBANKS NIJHUIS PACKAGED FIRE PUMP SYSTEMS.

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Pressure Limiting Driver (PLD)

Inspection and Testing of Water-Based Systems

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

KODAK VERSAMARK, INC.

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

INSPECTION AND TESTING OF EMERGENCY GENERATORS

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

MOTOR FUEL DISPENSING SAFETY

Model 1210C Battery Powered Pump Shown. Description

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

The Jockey Pump, an Important Part of a Fire Pump System.

FAIRBANKS NIJHUIS FIRE PUMPS.

BERMAD Fire Protection

CHAPTER. Standpipes and Hose Systems OVERVIEW. Standpipe and Hose Systems Defined

BERMAD Fire Protection

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Automatic Fire Sprinkler Submittal Requirements

Maintaining Fire Protection Systems

Oil and Coolant Circulating Heating System. Model - OCSM

FIRE PROTECTION SYSTEMS ACCEPTANCE INSPECTION AND TESTING PROCEDURE

Prime Power Services, Inc. Georgia, Carolinas NFPA 110 Standards for Emergency & Stand by Generators June 1, 2010

NFPA31FuelOilPiping 1 Revised

FIVE YEAR CERTIFICATION REPORT

National- Spencer Inc.

I. Introduction. 10 minutes

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

NFPA 25 FAQs. 1. When inspecting an old system (60 years or older), when/where does NFPA 25 require a system to be upgraded to present standards?

TECHNICAL INFORMATION Bulletin

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

Design & Construction Standards, Revised January

The following definitions apply with regard to requirements specified in this document:

TRAINING BULLETIN Fire Apparatus Pump Test

ENGINE COOLING SYSTEM

C I T Y O F S E L M A F I R E D E P A R T M E N T

SEVERE WINTER WEATHER PROPERTY RISK CONTROL

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Winnipeg Fire Department Fire Prevention Branch

Diesel Engine Driven Generators Page 1 of 6

Northern Region. Underground Storage Tank

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

DATA COLLECTION AND PUMP ENERGY SAVING OPPORTUNITIES. Presented By: Rick Rumsey, P.E.

TABLE OF CONTENT

BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.

PACKAGED FIRE TUBE BOILER

Horizontal Split Case Fire Pumpset Diesel Engine Driven

ACCUMULATOR INSTALLATION

TECHNICAL INFORMATION Bulletin

CARING FOR YOUR WATER HEATER

Underground Storage Tanks

Pump Maintenance - Repair

300 Series PA Pump and Cooler Assemblies

2" & 3" Poly Wet Seal Pump Instruction Manual

OREGON FIRE CODE Interpretations and Technical Advisories

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

15GAL STEEL OIL DRAIN WITH 110V PUMP

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

COMMISSIONING OF HVAC SYSTEMS

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

SECTION DIESEL-DRIVEN, FIRE PUMPS

Backup Fuel Oil System Decommissioning & Restoration Plan

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Centrifugal Fans and Pumps are sized to meet the maximum

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Roland Garcia Pearland Fire Department

C. starting positive displacement pumps with the discharge valve closed.

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

Section 14. Forklift Safety Contents 14.1 Operator Safety

A cure for water damage in real estate

T E C H N I C A L S P E C I F I C A T I O N. SUPER FUEL & LUB TRUCK Fuel tanker and lubrication truck (6x6)

First Revision No. 147-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Boiler and Burner Cleaning and Servicing Specifications

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

PBX Series Quick Fit Connector Bimetallic Steam Traps

FIRE SAFETY PLAN FOR KITCHENER, ONTARIO

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Emergency Response Guide

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

Transformer Deluge Systems

Practical Guidelines for Electrical Area Classification in Combustion Turbine-Generator Power Plants

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

NFPA 20 Update 2013 Edition. Revision Cycle. NFPA 20 Update /1/2013. Goals and Objectives

Transcription:

RISK CONTROL AND CLAIM ADVOCACY PRACTICE TECHNICAL ADVISORY BULLETIN November 2014 www.willis.com FIRE PUMP TESTING Fire pumps are a critical part of a fire protection system, especially when they are fed via suction from water tanks. Properly maintained and tested, fire pumps will deliver countless years of worry-free performance. Two types of testing of fire pumps are needed: 1) Weekly/monthly testing, typically done by facility personnel and 2) annual flow testing that should be done by a contractor. Maintenance and testing of fire pumps should be in accordance with NFPA 25 Standard for the Inspection, Testing and Maintenance of Water-Based Fire Protection Systems. The current edition of NFPA 25 requires weekly tests of diesel-driven fire pumps and monthly tests for most electric pumps. However, weekly tests of electric fire pumps are required 1) if a pump serves a high rise building that is beyond the pumping capacity of the fire department, 2) for pumps with limited service controllers, 3) for vertical turbine fire pumps and 4) for pumps that take suction from ground-level tanks or a source of water that does not provide sufficient pressure to be of material value without the pump. Some insurers or authorities having jurisdiction (AHJs) may require weekly testing of electric fire pumps even without any of the above four conditions. WEEKLY/MONTHLY FIRE PUMP INSPECTIONS AND TESTS The weekly/monthly test should be accomplished by a pressure drop. This may be done by opening the valve on the sensing line or another valve in the pump room. Electric pumps should be run for a minimum of 10 minutes; diesel-driven pumps, a minimum of 30 minutes. Sample forms for weekly/monthly inspections and tests are attached to this bulletin. ANNUAL FIRE PUMP FLOW TEST An experienced third-party contractor should perform the annual test. It is not unusual for the performance test results to indicate a problem with the fire pump or with the pump s water supply. However, the contractor often will not interpret the test results for the building owner. Therefore, the building owner must know how to interpret fire pump performance test data. If a problem is identified the contractor should try to address the problem while on site. This bulletin will provide building owners with information to help them understand and interpret data from the annual performance testing of centrifugal pumps. This information applies to centrifugal pumps only. Other types of pumps have different performance characteristics. Fire pumps should furnish the pressure delivered during the initial fire pump acceptance test or the pressures as indicated on the pump nameplate. When this information is not available, the pump should deliver: 150% of rated capacity at 65% of rated pressure 100%of rated capacity at rated pressure A maximum of 140% of rated pressure at churn (no flow) 1

The following figure illustrates the pressures the pump should produce. Acceptable test results can be up to 5% below the above figures due to possible experimental error. Test results worse than 5% below the above figures should be investigated and corrected. 150 Shutoff 140 Head capacity curve with steepest shape permissible Percent of rated total head Flat head capacity curve Rated total head 100 Rated capacity 65 50 0 50 0 100 150 200 Percent of rated capacity ANALYSIS OF A SAMPLE FIRE PUMP FLOW TEST The results of a fire pump flow test that is taking suction from a 12-inch public water main are shown below (related data color-coded for clarity). The pump is rated at 2500 gpm at 110 psi and is driven by a 200 hp electric motor. At churn (dead head or no flow), the pump nameplate indicates the pump will deliver 129 psi; at the rated flow of 2500 gpm, it will deliver 110 psi, and at 150% of rated flow (3750 gpm) it will deliver 82 psi. The pump test yielded a churn pressure of 126 psi, 117 psi at rated flow and 97 psi at 150% of rated flow (3750 gpm). Therefore, the pump delivered better results than shown on the pump nameplate and is considered to be in good or excellent condition. If the pump nameplate data had not been available, the pump would have been expected to produce a maximum pressure of 154 psi (140% of pump rating of 110 psi) at churn, a minimum of 110 psi at 2500 gpm and 71.5 psi (65% of pump rating of 110 psi) at 3750 gpm. Fire Pump Fire Pump Motor Make ITT AC - 10X8X20F Make WEG Size L Type 8100 RPM 1780 RPM 1785 S/N 123456789 IMP DIA GPM 2500 at Dead Head Pressure 129 PSI RPM VOLTS AMPS 1794 486 486 488 87 97 1780 481 482 485 194 1776 480 483 481 222 2 17 Stages 1 110 PSI 150% at 82 PSI PRESSURE HP AMPS 220 VOLTS FRAME 0 S/N 9876545321 Coupling WOODS 200 460 PITOT TUBE PRESSURE GPM 126 CHURN 0 145 117 16 14 14 14 115 97 19 19 20 20 SUCT DISCH NET 1063 44 170 196 200 28 222 236 18 2568 20 3732

WATER SUPPLY PERFORMANCE The annual fire pump performance test is also an opportunity to determine if there are any problems with the fire pump water supply, such as shut or partially shut valves or obstructions from the water supply to the pump. If the test is conducted with a flow meter, it usually will not be possible to identify problems with the fire pump water supply. Determining if there is a problem with the fire pump water supply can be difficult unless the person analyzing the test results is familiar with the water supply for the pump and understands hydraulics. The results of the pump test can be compared to previous pump tests to identify any potential problems; however, this may not identify water supply problems that have existed for some time. In the above example, the city water pressure was 44 psi at no flow, 28 psi at a flow of 2568 gpm and 18 psi at 3732 gpm at the suction side of the fire pump. We don t know the details of the public water system, except that the pump is supplied by a 12-inch water main. It appears that there is not any problem with the water supply to the pump. Had the pressure dropped to a value of 18-20 psi at 2500 gpm, there may have been reason to believe there could be a problem with the public water supply. Pictures showing a fire pump and a hose monster after a fire pump flow test. The underground water main supplying the pump had not been properly flushed prior to installing the fire pump. 3

FIRE PUMP FLOW TESTING SAFETY CONSIDERATIONS Serious injuries can occur when flow testing fire pumps. Many fire pumps have more horsepower than cars. It is essential that appropriate precautions be taken before testing. Only use contractors who are experienced conducting pump flow tests. The following are examples of precautions the contractor should take. If they cannot be taken, the pump test should be deferred. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Some pump tests may expose personnel to a confined space; a fall; drowning, electrical, fuel and/or battery explosion hazards. Proper safety precautions must be taken for these and any other potential hazards. Minimize the number of personnel involved in conducting or witnessing the test. Under no circumstances should anyone (including professional fire fighters) manually hold any hoses or hose nozzles during a fire pump test. Hose nozzles must be secured so that there is no chance they will come lose. Hose monsters are safer to use than hose nozzles. Avoid discharging nozzles back into the top of a tank. If it is necessary to do so, provide adequate ladders, platforms and guard rails. Everyone present should know how to shut the pump off in an emergency. The contractor should carefully examine the pump test header. It should be in good condition and securely attached to the supply pipe. Carefully examine the hose valves on the test header. They should be in good condition, free of any significant rust and free of cracks. Ensure the hose or nozzles are screwed all the way onto the hose valves. Carefully examine the condition of the fire hoses, hose couplings and hose nozzles. Replace any hose that shows signs of possible failure. This is especially important if the test header is located inside the pump room or building. Request documentation on the most recent hydrostatic test of the fire hose if there is any doubt. The use of hose monsters instead of hose nozzles reduces the likelihood of injuries. When a fire hose is used, be sure the nozzle is secured so it cannot work or vibrate loose. Be sure to check the oil level, coolant level, battery electrolyte level (low electrolyte level can cause the battery to explode) and fuel level before starting the engine. The fire pump should be started manually to prevent any pump running timers from operating during the test. Before starting the test, only the personnel necessary for the test should be in the vicinity of the hoses and pump. Adjusting water flow through the test header with the test header control valve (typically a 6-10 inch valve) is generally safer and faster than adjusting water flow with the 2½-inch test header valves. Aim hose nozzles or hose monsters so that discharged water will not cause damage or injury. During the test, run variable speed drivers (engine or turbine) under governor control. As a critical part of a fire protection system properly maintained and tested, fire pumps will provide numerous years of reliable performance. CONTACTS For additional information contact your Willis Client Advocate, Property Risk Control Consultant or: John Ammeson, PE, ARM, CFPS Senior Property Risk Control Consultant Risk Control and Claim Advocacy Practice Willis NA john.ammeson@willis.com 4

SAMPLE MONTHLY ELECTRIC FIRE PUMP REPORT Pump Location: Pump Rating: gpm @ @ rpm Completed By: 1. Yes Is fire pump controller on automatic?... 2. Is jockey pump controller on automatic?... 3. Are all jockey pump and fire pump control valves open?... 4. Is jockey pump running frequency normal?... 5. Is pump room adequately heated?... 6. Did fire pump start automatically by a drop in water pressure?... Record the following: Pump start pressure: No Pump discharge pressure: Pump suction pressure: 7. Are pump bearings operating at normal temperature?... 8. Are pump packing glands leaking sufficient water?... 9. Is pump free of unusual noises and vibrations?... 10. Is pump circulating relief valve operating?... 11. Is the pump test header drained to prevent freezing?... 12. Is a charged fire extinguisher in the pump room?... 13. Is pump room clean and free of combustible materials?... 14. Is pump controller s Power Available light on?... 15. Did all remote pump alarms function properly? (i.e., running, power loss, etc.)... 16. Was water tank overfilled to verify it s full, or is reservoir at normal level?... 17. Was pump run for at least 10 minutes?... 18. Were both the jockey pump and fire pump controllers left on automatic?... Explain all No responses and corrective actions taken: (Ex: 8. Pump packing leaking too much repaired 5/1) Reviewed By: 5

SAMPLE WEEKLY DIESEL FIRE PUMP REPORT Pump Location: Completed By: Pump Rating: gpm @ @ rpm Yes 1. Is fire pump controller on automatic?... 2. Is jockey pump controller on automatic?... 3. Are all jockey pump and fire pump control valves open?... 4. Is diesel fuel line locked open?... 5. Is jockey pump running frequency normal?... 6. Is pump room adequately heated?... 7. Is adequate combustion air provided?... 8. Is engine oil at the correct level?... 9. Is engine coolant at the correct level?... 10. Is water level and specific gravity correct for both batteries?... 11. Does battery charger appear to be functioning properly?... 12. Did fire pump start automatically by a drop in water pressure?... Record the following: Pump start pressure: Pump discharge pressure: Pump suction pressure: 13. Did fire pump start manually on each set of batteries?... 14. Are pump bearings operating at normal temperature?... 15. Are pump packing glands leaking sufficient water?... 16. Is pump free of unusual noises and vibrations?... 17. Is engine cooling water discharging effectively?... 18. Is the pump test header drained to prevent freezing?... 19. Is a charged fire extinguisher in the pump room?... 20. Is pump room clean and free of combustible materials?... 21. Did all remote pump signals function properly? (i.e., running, controller not on automatic, etc.)... 22. Was water tank overfilled to verify it s full, or is reservoir at normal level?... 23. Was pump run for at least 30 minutes?... 24. Did engine achieve proper operating temperature, speed & oil pressure?... Record the following: Water temperature: F Engine speed: rpm Oil pressure: Engine hours: hrs 25. Is diesel fuel tank at least ¾ full?... Record fuel tank level: 26. Were both the jockey pump and fire pump controllers left on automatic?... No Explain all No responses and corrective actions taken: (Ex: 10. Battery A water level low filled 5/1) Reviewed By: 6

Willis North America Inc. Brookfield Place 200 Liberty Street 7th Floor, New York New York 10281-1003 United States Tel: +1 212 915 8888 www.willis.com The observations, comments and suggestions we have made in this publication are advisory and are not intended nor should they be taken as legal advice. Please contact your own legal adviser for an analysis of your specific facts and circumstances. 50600/10/14 7