Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26



Similar documents
Part 1 System Modeling & Studies for Existing Systems

misconceptions about arc-flash hazard assessments

A USERS GUIDE TO ARC RESISTANT LOW VOLTAGE SWITCHGEAR & MOTOR CONTROL ANALYTICAL COMPARISON VS ARC FLASH TEST RESULTS

Choosing the Best Solution for Reducing Arc Energy

Arc Flash Mitigation. Remote Racking and Switching for Arc Flash danger mitigation in distribution class switchgear.

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

ARC FLASH CALCULATIONS & LABELING REQUIREMENTS

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

Arc Flash Hazards. Electrical Hazards. Dan Neeser Field Application Engineer Electrical Hazards 2/18/2015. Shock.

Understanding Arc Flash

Introduction to Arc Flash

What s up with Arc Flash?

The Other Hazard of Electricity. Larren Elliott Ph.D. Lindsay Polic, CSP, REHS

A Guide to Performing An Arc Flash Hazard Assessment Using Power Analysis Software

INTRODUCTION ARC FLASH PROTECTION AND SAFETY MEASURES. September 2010

ETAP Arc Flash Analysis

IMPLEMENTING THE NEW ELECTRICAL SAFETY REQUIREMENTS

Arc Flash Energy Mitigation Techniques

Arc Flash Avoidance and its Application to Overhead Traveling Cranes

Short Circuit Current Calculations

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

2012 NFPA 70E. Ten Most Important Changes. John A. DeDad

THE PER-UNIT SYSTEM. (2) The per-unit values for various components lie within a narrow range regardless of the equipment rating.

Safety By Design. Strategies for Electrical Contractors

Arc Terminator Active Arc-Resistant Switchgear

Low Voltage Transformer Through-Fault Protection: A System Approach

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

Demystifying arc flash hazard management

Radial Distribution Test Feeders

ARC FLASH HAZARD OVERVIEW. Presented August 13, 2015 WWOA Lake Michigan District by Mead & Hunt, Inc.

How Much Voltage Drop Is Acceptable?

SALISBURY ASSESSMENT SOLUTIONS

OSHA & ARC FLASH HAZARD ANALYSIS

The following table shows approximate percentage wise the

A Survey of Arc Flash Computation Methods and Mitigation Strategies By Dr. Carl J. Spezia

NFPA 70E Updates Affect Your Most Valuable Assets

RISK MITIGATION for ELECTRICAL WORK. Feb 2013 San Diego CA

Fault Characteristics in Electrical Equipment

Arc Flash Mitigation & Selective Co-ordination

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

New standardized approach to arc flash protection

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

Mitigation of Arc-Flash Hazards and Reduction of Costs by Selective Arc-Flash Protection

Analyzing Electrical Hazards in the Workplace

100% Rule Alternate Method Arc Blast Arc Flash Approved Approved Equipment Authority Having Jurisdiction (AHJ) Authorized Work Bare Hand Work

SPECIAL TOPICS ON GROUND FAULT PROTECTION AND PROTECTION COORDINATION IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

Electrical Safety Program

How To Balance Three Phase Power In A Balanced System

Roadmap to Compliance with NFPA 70E Arc Flash Requirements

Earthing Guidance Notes

OSHA and NFPA 70 Understanding NFPA 70 and its Implications in Electrical Inspections 2010

Grounding of AC generators and switching the neutral in emergency and standby power systems

ELECTRICAL SAFETY RISK ASSESSMENT

Integrating SPDs in Switchgear & Switchboards Causes More Problems than it Solves

How to reduce exposure to arc flash hazards

Power measurement in balanced 3 phase circuits and power factor improvement. 1 Power in Single Phase Circuits. Experiment no 1

Protect your home and family with Advanced Technology from Cutler-Hammer

2004 TRANSMISSION SYSTEMS SEMINAR MEDIUM VOLTAGE, METAL-CLAD ARC RESISTANT SWITCHGEAR: ENHANCING WORKPLACE SAFETY

Voltage Unbalance and Motors

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

OSHA Published First-Ever Arc Flash Protection Requirements for the Electric Power Industry Significant changes and unprecedented compliance

SAFE ELECTRICAL WORK PRACTICES & 2015 NFPA 70E

Basic Electrical Technology Dr. L. Umanand Department of Electrical Engineering Indian Institute of Science, Bangalore. Lecture phase System 4

Chapter 24. Three-Phase Voltage Generation

Modeling of Transmission Lines

THE reliability, cost, and safety of electricity and industrial

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Short-circuit, Protective Device Coordination & Arc Flash Analysis. By Albert Marroquin Operation Technology, Inc.

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Power transformers. Special transformers Railway

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Chapter 12 Three-Phase Circuit

Open Phase Conditions in Transformers Analysis and Protection Algorithm

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

Medium Voltage (MV) & High Voltage (HV) Training Module 6. Date of the presentation

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Engineering innovation

High-Efficiency AC Power Distribution for Data Centers

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

2008 Eaton Corporation. All rights reserved.

CHAPTER 2 EXAMPLES AND TABLES

Rule Fast Track Analysis for National Life Insurance Co.

SIMULATING HYBRID ENERGY GRIDS IN SMART CITIES FOCUS ON ELECTRIC ENERGY SYSTEMS

Low Voltage Circuit Breakers. Arc flash hazards

Technical Guide. SKM Arc Flash Line Side vs. Load Side

Requirements for Electrical Installations

Test Before Touch Easier Said Than Done. Ken Crawford, DuPont Kent Haggerty, Dupont

Power surges can also be generated by equipment in your facility such as:

Definition AC Power Distribution

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

Three-phase AC circuits

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Transcription:

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

Assessing The Hazards Of High and Low Voltage Single-Phase Arc-Flash By Albert Marroquin One common question being asked is how to determine the hazard level associated with 1-Phase (1-P) Arc Flash (AF) incidents. There is very little information about this type of circuit in the available guidelines such as CSA Z462-08, NFPA 70E 2009 & IEEE 1584 2002. If the right risk level is not properly determined, we run the risk of over-protecting or under-protecting personnel that are working on this type of electrical system. The objective of this article is to present different methods for assessing the hazards of high and low voltage 1-P equipment, and to justify the results taking into consideration the behaviour of arc faults at different voltage levels. 1-P circuits are used mostly for low scale power distribution. Most of the 1-P circuits are located in residential and

Electrical Safety Measures - Summer 2009 27 Figure 1. Typical 1-P circuit connections small commercial zones, but they are also commonly found in industrial plants being used for lighting loads and other types of circuits such as service drops for temporary equipment around the facility (loadcentres). Personnel come in contact with these types of equipment on a daily basis. Typical 1-Phase Circuits The most common types of 1-P circuits can be classified as Line to Neutral (i.e. AN, BN, CN), Line to Line (AB, BC, CA) and centre tap (L1 & L2). Figure 1 shows typical 1-P circuit connections which can occur at different voltage levels. Examples of LV (< 1.0 kv) 1-P applications include centre tap 240/120 Volt pole mounted distribution connections (See Figure 2) and phase to phase or line to neutral circuits (i.e. 347 Volt lighting circuits). Examples of HV 1-P circuits include traction power distribution for railway transportation systems where 1-P voltages between the pole and center tap are as high as 55 kv (V1, V2) or 110 kv (V1+V2). V1 V1 N V1+V2 V2 V2 Figure 2. 1-P centre tap transformer USA/CANADA V1, V2 = 120 Volts V1 + V2 = 240 Volts Figure 3. One-line diagram for a 1-P 240/120 V circuit. Figure 3 shows a diagram for a pole mounted 1-P 50 kva transformer service for a 240/120 Volt small loadcentre inside an industrial facility. The size of the transformers is typically 100 kva or less (400 Amps at 240 Volts); however in some Circle 84 on Reader Service Card

28 Electrical Safety Measures - Summer 2009 cases larger transformers need to be used. An AF on this load center could easily occur between a Phase to Ground or between the L1 and L2 poles to constitute a 240 Volt fault. 1-Phase Arc Flash Behaviour Before we can pursue a solution to the problem of how to determine the energy released by 1-P circuits, we have to understand some fundamental behaviours of electrical arcs at different voltage levels. The energy released by the arc is determined from the product of arc voltage drop E a and the arc current I a, (Lee, Ralph H. The Other Electrical Hazard: Electric Arc Blast Burns IEEE Transactions on Industry Applications Vol. IA-18 No. 3, 1982). Figure 4 illustrates the equivalent arc resistance which is introduced by the arc plasma. The effect of this fictitious arc resistance is to limit the arc current to a value smaller than the available bolted (metal to metal) fault current of the circuit. The heat delivered by the arc is generated by the rapid expansion of plasma composed of vapourized metal. The extreme temperatures in this metal vapour plasma increase the overall impedance of the circuit which in turn increases the magnitude of E a. This is why in bolted faults there is very little heat generation since the bolted metal conductors offer very little resistance and thus the arc voltage drop is not present. In high voltage 1-P and 3-P (>1.0 kv) circuits, the gap between conductors can be easily bridged. This behaviour tends to reduce the effect of the fictitious arc resistance and to yield higher arc currents which are smaller than the bolted current by only 5 to 10%. This is the reason why conservative approximations are made to set the arc current to be limited only by the system source impedance Z s (>15.0 kv). The biggest concern with this behaviour is that for 1-P faults we must consider the additional impedance of the zero sequence components (high resistance ground paths) which further reduce the magnitude of I a and inversely affect the fault clearing time (time needed for protective devices to open and extinguish the fault). This lower arc current magnitude behaviour is not necessarily present in a 3-P system since the arc may initiate Figure 4. AF across a LV 1-P transformer with centre tap connections. between a Phase to Ground (neutral), but it will quickly escalate to a higher current 3-P Arc. For 1-P circuits, the path through grounded conductors with higher impedance may be the only route for the flow of I a. The behaviour of Line to Line 1-P circuits is not expected to be much different from that of 3-P arcs because we should not have higher resistance paths involved. Of course the appropriate magnitude of the Line to Line bolted fault currents must be estimated before determining the arc current. Low voltage arcs have different behaviour. Depending on the kva rating of the equipment, the LV arc may or may not have enough voltage difference between the source voltage E s and the arc voltage drop E a to power up the arc and bridge the gap between conductors. The arc voltage drop is about 75 to 100Volts/inch and the source voltage E s is relatively small. For a 2 inch gap, we are already looking at 150 to 200 Volt arc voltage drop and this value would be very near the source voltage E s. Depending on the source voltage E s and the available fault current, the LV arcs may or may not be self- sustaining. A typical threshold for self-sustaining arcs can be set at around 208 to 240 VAC and fault current of about 10 ka (at 240 Volts). For our 1-P system in Figure 4, you may expect an arc to be possibly generated on the 240 Volt circuit, but not on the 120 Volt circuit. Regardless, we can still estimate the heat and power which are present in the 120 Volt circuits using the bolted fault current I bf and source voltage Es however it would not be really necessary since we do not expect any significant heat to be generated from this circuit. How To Obtain 1-Phase Arc Flash Results With the understanding of the behaviour of arc faults at different voltage levels, we can proceed to determine how to obtain analysis results for different types of 1-P equipment. The 3-P equations can be used to obtain conservative results on 1-P applications and are likely to yield conservative results (CSA Z462-08 Annex D.7.3 and IEEE 1584 2002 Section 5.1). Therefore, the equations of CSA Z462-08 Annex D.7.3 and D.7.4 (IEEE 1584 2002 Empirical equations) can be used as long as the voltage of the 1-P circuits is between 0.208 kv and 15 kv. The equation of CSA Z462-08 Annex D.7.5 may be used for 1-P circuits (AB, BC, CA, and LL) with nominal voltage above 15kV. The results should be conservative. For possible AN, BN and CN circuits above 15 kv, but it is also possible to use CSA Z462-8 Tables D.6 and D.7 to obtain a less conservative (but maybe more accurate) estimate of the released arc energy. Please keep in mind that the voltages in these tables are given as the Phase to Phase circuit voltage and you will need to divide by 3 to find the values for the 1-P to Neutral or Ground faults. For low voltage equipment, it is recommended that 1-P AF results be obtained from the equations given in

30 Electrical Safety Measures - Summer 2009 CSA Z462-08 Annex D.7.3 and D.7.4 as long as the 1-P pole voltage is above 0.208 kv and the available bolted 1-P fault current is between 0.7 ka and 106 ka. These equations may yield over conservative results especially as the voltage levels go below 0.240 kv. Alternative to the empirical equations, we can use the equations of CSA Z462-08 Annex D.7.5 for 1-P circuits which fall outside of this range. Exceptions For 1-Phase Circuit Arc Flash Analysis CSA Z462-08 Section 4.3.3.1 contains an exception for not providing a detailed AF hazard analysis if the circuit voltage is less than 240 Volts AC and the circuit is supplied by a single transformer rated < 125 kva. Taking credit for this exception limits the amount of 1-P circuits which need to be analyzed. However, taking credit for this exception does not imply that a Hazard/Risk Category does not need to be applied using the Table Method of arc flash hazard analysis. The requirements of CSA Z462-08 Section 4.3.7.3.9 Table 4 must still be met and the tasks require Hazard/Risk Category 0 or 1 PPE. Circuits fed from 1-P transformers rated < 125 kva fall into this Hazard/Risk Category. If a Hazard/Risk Category 1 level is assigned to any circuit within this range, then we are making the assumption that the circuit s released energy is not higher than 4.0 cal/cm 2. The arc flash protection boundary (AFPB ft) can be determined based on this energy limit. Figure 5 shows the difference in the energy and AFPB obtained from two simulations. The results in the blue colour were obtained from the equations of CSA Z462-08 Annex D.7.3and D.7.4. The results in the red colour were automatically assigned a Hazard/Risk Category 1 level. The calculation results determined the Hazard/Risk Category 2 results for the 240 V Panel 1. The AF Figure 5. AF calculated results (blue) vs. Category assumptions (red). results at Panel 1 depend exclusively on the total fault clearing time of Fuse 1 on the primary side of the pole transformer (7.2 kv Line to Neutral). The selected fuse is size 8A, but it would not be uncommon to see a size 12A fuse being used to protect this transformer (high overloads are sometimes used to maintain higher service continuity). If this were the case, the predicted energy obtained from the equations would be as high as 13 cal/cm 2 with a fault clearing time of almost 1.5 seconds. The conclusion from this example is that the equations can be safely used to determine 3- P and 1-P AF results and will yield conservative results. However, as long as the circuits fall within the guidelines of CSA Z462-08 Section 4.3.3, then it is safely assumed that Hazard/Risk Category 1 or 0 PPE requirements are good for these locations. Conclusion CSA Z462-08 and NFPA 70E 2009 do not provide specific 1-P circuit calculation methods, however, it can be generalized that the behaviour of 1-P faults is very similar to that of 3-P faults since the same fundamental physical principles of system impedance and voltage apply to both. It would be of great benefit to the public in general for the technical committees to extend the research of arcs to specifically common 1-P applications. This will remove some of the ambiguity in the available guideline so that individuals can assess the hazard of this type of circuit more easily. There are deficiencies in the available equations and they may not account for all the parameters involved in unbalanced arc faults; however, we still have to arrive at conservative conclusions based on the current methods. Albert Marroquin is a principal electrical engineer and a registered professional engineer in the state of California. He is the test manager for Operation Technology, Inc developer of ETAP Arc Flash analysis software. Circle 86 on Reader Service Card Circle 87 on Reader Service Card