Increasing Power Plant efficiency for safe wet stack Operation



Similar documents
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Post-insulation of cellar ceiling and cellar walls

Mold Preventing I nterior System

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

Green Thread Product Data

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

Multi-pollutant control solutions for coal based power plants

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

BLACK JACK ALL WEATHER ROOF COATING

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a, Xue Yang 1, b and Xiao-wei Song 1, c

A Guide to Trouble-Free Cooling Towers

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

TECH BULLETIN. Roofing No. Impact of Temperature on Polyiso R-value. Subject: Impact of Temperature on the R-value for Polyisocyanurate Insulation

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Derakane epoxy vinyl ester resins: The Evolution of Corrosion Resistant FRP

Phosphoric Acid Anodized Aluminum Honeycomb

Why is my air conditioner dripping on my customers?

Technical Manual - Section 1 Introduction to Lytag lightweight aggregate

CONDENSATION. Section Break (Next Page)

Building Owners Guide to a Duro-Last System!

Asphalt Shingle Application Requirements

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Renovating Your Basement

Ground Gas Barriers.

European Technical Assessment ETA-15/0028 of 23/02/2015

PRODUCT DIRECT EVAPORATIVE COOLING PAD DATA SHEET

COMMERCIAL BUILDING APPLICATIONS

Module 3: Sewer Material Lecture 3: Sewer Material

CFD Modelling of Wet Flue Gas Desulphurization (WFGD) Unit: A New Era of Process System Control and Optimization

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

CONDENSATION IN REFRIDGERATED BUILDINGS

Module 3 : Sewer Material. Lecture 3 : Sewer Material

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Basement Moisture Problems

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

Waterproofing construction Joints

Waterproofing of exterior walls at 7 Anderson Place, Queenstown

OPTIONS. for. Replacing Boiler Plant. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

POLYURETHANE FOAM CONCEPT

Bituminous Sheet Flat Roofs: Their repair and maintenance

Automobile Air Conditioning Primer

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

The BASA Guide to the ISO Classification of Sealants for Building Construction

CODE NOTES. Insulation Requirements in Commercial Buildings for Mechanical and Service Hot-Water Piping

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS

Condensation. Some Causes, Some Advice

Peel & Seal Self-Stick Roofing Solutions

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Built to Last. Built for Beauty. Good. Solid. Logix. TM

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

MILLIKEN CLEAN COAL TECHNOLOGY DEMONSTRATION PROJECT UNIT 2 ELECTROSTATIC PRECIPITATOR PERFORMANCE TEST RESULTS BEFORE AND AFTER MODIFICATION

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

Lecture 24 - Surface tension, viscous flow, thermodynamics

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Integrated Solar Radiant Systems

Fluidized Bed Based CO 2 Capture by Carbonate Looping

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

MASONRY RESTORATION Lime Putty Mortar Repointing Guide

Guide for SOLID CONCRETE BLOCK SEALS

THE MINISTRY OF ENVIRONMENTAL PROTECTION, PHYSICAL PLANNING AND CONSTRUCTION

Gas-Fired, Residential Storage Type Water Heaters

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

Chilled Water HVAC Systems

Steam System Best Practices Condensate System Piping

Laddomat Charging unit

ICS: Strengthening retrofitting of reinforced concrete structures by gluing of fibre reinforced polymeric fabrics (FRP fabrics)

Energy Efficient Operations and Maintenance Strategies for Boilers

SECTION XXXXXX TECHNICAL SPECIFICATIONS FOR INSTALLATION OF PROTECTIVE COATINGS FOR MANHOLES, WETWELLS, AND OTHER SANITARY SEWER STRUCTURES

PTFE Slide Bearings 04/10 149

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Site Inspection Report

Best Practices for Crawl Space Insulation

DENSO WATERPROOFING SYSTEMS


Twinning «Improvement of the Energy Efficiency in Turkey»

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Water Damage & Repair

Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

1 DESCRIPTION OF THE APPLIANCE

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

Transcription:

Increasing Power Plant efficiency for safe wet stack Operation Albert de Kreij Albert de Kreij joined Hadek Protective Systems in 1989. He has been closely involved in a number of projects with the use of Borosilicate Glass Block Linings especially in wet stack operation conditions. point where they need to be modernized. Many stations have the option of not renewing their reheat system and switching to wet stack operation. Elektrárny Opatovice a.s. decided to refurbish its Opatovice power plant with two new wet limestone FGD systems (Figure 2), to eliminate its reheat system and to operate wet stack. It was also decided that the existing concrete chimney with sectional brick flue would be re-used. Introduction David K. Anderson David Anderson is currently a Principal/Owner of Alden Research Laboratory, the oldest hydraulic testing laboratory in the United States. More information about David Anderson and his company Alden, the acclaimed leader in solving flow related Engineering and Environmental Problems can be found in www.aldenlab.com. Elektrárny Opatovice a.s. is one of the leading suppliers of Electricity and Heat in the Czech Republic and the owner of the 698 MW lignite firing Opatovice Power Station (Figure 1). The power plant was built between 1959 1960 and is located 100 km eastwards of Prague. The Czech Republic has a large number of coal and lignite fired power stations that have been retrofitted with flue gas desulphurization (FGD) plants in the early 1990 s. Opatovice Power Plant has FGD systems since 1998. Many FGD plants of this generation are now reaching a Figure 2: New wet limestone FGD s left and right from the chimney This report describes the Opatovice wet stack modification project with the risks of wet stack operation and the steps taken towards safe wet stack operation. Omega Teplotechna a.s. Praha was the contractor for the Optovice wet stack modification project. Hadek Protective Systems supplied the PennguardTM lining materials and the Quality Supervision for all PennguardTM lining activities. Alden Research Laboratory performed a detailed flow model study with recommendations for Opatovice Power Station to achieve environmentally acceptable wet stack operation. Figure 1: 698 MW lignite firing Opatovice Power Station Figure 3: Outside surface brick flue attacked by acidic condensate 109

CICIND REPORT Vol. 32, No. 1 Figure 4: PennguardTM Block Lining System Risks of wet stack operation The first risk of operating wet stack is using the existing chimney. Elektrárny Opatovice a.s. decided to re-use its 142 m high chimney with 7.9 m diameter sectional brick flue for wet stack operation. By eliminating the reheat system, the plant operates with 100% treated, wet flue gas of 60 ºC, which means low temperature, acid condensing operation. Brick flues are permeable for acidic flue gas condensate. Figure 3 is an example picture showing the outside surface of a brick flue attacked by acidic condensate, caused by wet stack operation. If the brick flue would be left unprotected, the structural integrity of the whole chimney would be at risk in the end. The customer decided to use the PennguardTM Block Lining System (Figure 4) to seal the brick chimney flue from the acidic condensate. The PennguardTM Block Lining System has been proven durable and reliable for wet stack operating conditions for over 30 years. The system is completely resistant to sulfuric acid, impermeable to acidic flue gas and condensate, strongly insulating and lightweight. A PennguardTM lining is tolerant for imperfect substrates. Brick chimney flues have many imperfections, such as the many joints which may vary in width and depth. Figure 5: Gritblasting of existing brick flue Figure 6: Primer appplication The installation process of the PennguardTM Block Lining System can be summarized as follows (Figures 5-7): Step 1: Gritblasting of the brick flue to remove all dirt, deposits and other loose particles; Step 2: Application of the PenntrowelTM Epoxy Primer; Step 3: Application of the PennguardTM Blocks onto the brick surface with the PennguardTM Adhesive Membrane by semiskilled brick layers and under supervision of Hadek s QA Inspectors. Figure 7: Pennguard lining application 110

Figure 8: Sources of liquid on a chimney flue wall The second risk of wet stack operation is the risk of entrainment of acidic condensate droplets into the gas flow (which is called spitting) and the deposition of acidic droplets near the chimney. This is caused by a two-phase flow interaction of gas and liquid. There are three main sources of liquid in a wet stack, Figure 8. The first is droplet carryover from the absorbers mist eliminators and from re-entrainment of droplets off the absorber outlet duct walls. The second source is thermal condensation within the stack liner and the third is adiabatic condensation of liquid out of the saturated gas flow due to pressure drop within the liner. All of these contribute to the formation the liquid film on the liner wall which naturally wants to flow downward due to gravity. The main factor contributing to droplet re-entrainment from this liquid film is the velocity of the flue gas flow within the liner which imposes a vertical shear force on the downward flowing liquid film. As the flue gas velocity increases, the magnitude of the vertical shear force increases slowing the downward flow of the liquid film. At a critical velocity, the gravitational and gas shear forces are balanced and the liquid film stops flowing downward. As more liquid condenses on the liner wall, the resulting liquid film gets thicker and thicker until the surface of the film becomes unstable and droplets are re-entrained back into the gas flow. The critical velocity at which this occurs is dependent of the type of liner material used and is a function of the surface smoothness and construction methodology used to construct the liner. Figure 9 presents the liner flue gas velocities recommended in the EPRI/CICIND Revised Wet Stack Design Guide. As can be seen in this Figure, Borosilicate Block commercially known as the PennguardTM Block Lining System has the highest recommended favorable design flue gas velocity. This is due to two important properties of the material. First PennguardTM is made from closed cell foamed borosilicate glass which results in a significantly higher surface area inside the liner to which the down flowing liquid film can adhere. It is estimated that the actual surface area of the PennguardTM material is greater than twice the surface of a smooth surface as would be the case for an alloy or FRP liner. Second, PennguardTM is inherently an excellent insulator which Figure 9: EPRI Code recommended flue gas velocity for wet stack operation 111

CICIND REPORT Vol. 32, No. 1 Figure 10: Scale model of ducts and chimney of Opatovice plant significantly reduces the amount of thermal condensation experienced within the liner. A general rule of thumb for the impact of insulating a liner is that for every 51 mm of insulation, the quantity of thermal condensation is reduced by a factor of four. Because of this, the rate of liquid formation on the liner surface is significantly lower as compared to an uninsulated alloy or FRP liner. The insulation properties of PennguardTM are particularly noticeable during start up where the quantity of thermal condensation is significantly reduced because the hot flue gasses do not come in contact with a cold liner. This effect can be clearly seen in Figure 10 which presents the result of a study evaluating the total amount of direct film condensation vs. time in cold liners of various materials during plant start-up. Alden Research Laboratory was contracted by Hadek to perform a wet stack flow model study of the Opatovice power station with the objective of developing an effective liquid collection system for the prevention of stack liquid discharge (SLD). A physical flow model was built of the unit from the mist eliminator outlets of the plants two new WFGD absorbers Figure 11: Total direct film condensation during start up for different materials 112

Figure 12: Typical liquid collection system components through the absorber outlet ducting to a point in the stack liner approximately four liner diameters above the roof of the breach openings, Figure 11. The model was built to a scale of approximately 1:16 and was constructed primarily of Plexiglas to allow for flow observations. The liner itself was fabricated from a specially prepared fiber board to ensure that the surface in the liner model had the same wetting properties at the actual liner material. This is very important to ensure that the liquid film flow patterns are accurately modeled. To evaluate the performance of a wet stack system, the model must be run at two different flow rates to evaluate two different sets of physics. The first condition is designed to evaluate droplet trajectories within the system, the second is to evaluate the motion of the collected liquid films on the duct and liner surfaces. Using this information, liquid collectors and drains are designed and optimized both within the absorber outlet ducting and within the stack liner. These collectors and drains are designed to remove collected liquid as quickly as possible while minimizing the potential for droplet reentrainment back into the gas flow. Typical liquid collection system components are shown in Figure 12. As can be seen in this Figure, gutters are located on the duct walls, to direct collect liquid to the floor then into strategically placed drains. Within the liner, gutters are located around the breach opening and a ring collector is placed in the liner to collect all the liquid flowing downward from the upper portions of the stack. The liquid collection system designed for the Opatovice power station is expected to operate very well given the long duct runs between the absorbers and the liner which are good for wet operation. The liner is also operating at a very favorable liner velocity of 14.6 m/s which is significantly below the recommended maximum liner velocity of 18.3 m/s recommended for the PennguardTM Block Lining System. Conclusions Coal fired power plants operate more efficiently without flue gas reheat; PennguardTM linings can be used to make existing chimneys suitable for non-reheated wet stack operation; Wet stack flow model studies are a necessary tool to make wet stacks operate without discharge of acidic droplets. 113