FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS
|
|
|
- Daniel Randall
- 9 years ago
- Views:
Transcription
1 Perry Fiberglass Products, Inc. FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS
2 PERRY FIBERGLASS Perry Fiberglass Products, Inc. is a leading manufacturer of high quality Class 1 (Flame and Smoke) fiberglass reinforced plastic (FRP) products for exhaust, ventilation and process related duct systems in aquatic environments. Unlike stainless steel and aluminum, Perry Fiberglass FRP duct is impervious to the high chlorine concentrations in aquatic settings. Whether the application is a natatorium, aquatic center, aquarium, marine lab or other aquatic environment, Perry Fiberglass offers a variety of quality products and superior service. We supply both single wall and pre-insulated double wall duct to meet every ventilation need. Perry Fiberglass Products was established in 1984 and is headquartered in Avon Lake, Ohio, a suburb of Cleveland, Ohio. AQUATIC DUCT FROM PERRY FIBERGLASS Perry 20S Low Smoke Class 1 Flame and Smoke duct is used in a wide variety of aquatic settings. Typical applications include the following: Natatoriums Aquatic Centers Aquariums Marine Labs WHY CHOOSE PERRY FIBERGLASS FRP FOR YOUR DUCT NEEDS Perry Fiberglass FRP duct products offer numerous advantages over other duct materials such as galvanized, stainless steel, and PVC, especially in aquatic applications where corrosion is a concern. Below you ll find some of the many reasons we feel Perry Fiberglass FRP duct represents the best the industry has to offer: MATERIAL INTEGRITY Perry Fiberglass FRP duct is filament wound with glass and resins formulated for aquatic applications. The duct is manufactured to comply with recognized industry standards and can be customized to your exact specifications. STRENGTH Filament winding provides greater hoop strength, resulting in a much stronger duct than other methods of construction such as hand lay-up, and is far superior to metal products in many corrosive environments. Perry Fiberglass FRP duct is lighter than steel while offering superior corrosion qualities and equal air flow performance. DURABILITY Superior resistance to corrosion and leakage are hallmarks of Perry Fiberglass FRP duct. The same corrosion resistant qualities can be maintained on both the inside diameter (ID) and outside diameter (OD) allowing for a wide range of applications. SAFETY Perry Fiberglass FRP duct products meet the Flame and Smoke requirements of a Class 1 Flame and Smoke (25/50 respectively) duct per Underwriter s Laboratories (UL) 181 and Uniform Mechanical Code (UMC) 10-1 and are verified by an ASTM E-84 testing laboratory recognized by the following building code organizations under the Council of American Building Officials: ICBO; BOCA; SBCCI. VERSATILITY Perry Fiberglass FRP duct is available in long lengths up to 50 feet. A complete complement of standard fittings and special shapes are manufactured. The light weight duct is exceptionally strong, making it easy for workers to handle on the jobsite. Factory manifolding, color options and custom wall thickness are all available to meet unique job requirements. EFFICIENCY A duct system from Perry Fiberglass can be sealed to achieve a liquid-tight system. This assures efficient movement of the exhaust air while removing any risk of contamination. EASE OF USE Perry Fiberglass FRP duct can be field installed using simple tools. The joining material is the same glass and resin combination as the duct. Perry Fiberglass can provide field training for the installing personnel. Optional flanged or bell and spigot joints can be provided upon request. SUPERIORITY OF PRE-INSULATED DUCT Perry 20S-IR7 pre-insulated double wall duct offers superior performance over field-applied insulation. Advantages include: assured uniformity of insulation; permanent protection of insulation by encasement on both ID and OD by a FRP shell; permanent vapor barrier to prevent moisture from condensing within the insulation; and superior thermal conductivity.
3 PRODUCTS SAMPLE SPECIFICATION The following is for Aquatic Overhead and Underground Ductwork. AQUATIC OVERHEAD AND UNDERGROUND PERRY 20S LOW SMOKE CLASS 1 DUCT FLAME AND SMOKE DUCTWORK: single wall (20S) and pre-insulated double-wall (20S-IR7) Ductwork, including fittings, shall be constructed of filament wound fiberglass reinforced plastic, as manufactured by Perry Fiberglass Products, Inc. Manufactured per industry standards SMACNA, ASTM and PS minimums. Designed for min 10" WC pressure and 10" WC vacuum. A minimum designed structural safety factor of 5 shall be used. The resin shall be Perry 20S Low Smoke/Hetron FR992. Resin shall not contain fillers except as required for thioxtropic control of fire retardance. The duct and fittings, as a finished composite shall meet the Flame and Smoke requirements (25 and 50 respectively) of a Class 1 duct per UL 181 and UMC 10-1, and ASTM E-84. Liners and or coatings are not acceptable. Performance shall have been verified by an independent laboratory testing to UMC 10-1 standards. The testing laboratory shall have ICBO and BOCA approval. REQUIREMENTS OF A CLASS 1 DUCT PER UL 181 AND UMC 10-1 FLAME SPREAD: less than 25 SMOKE DEVELOPMENT: less than 50 FUEL CONTRIBUTED: less than 10 Wall thickness shall comply with PS duct standards. The ductwork shall be furnished with the following minimum wall thickness 0.125" for ducts up to 20" in diameter, 0.187" for ducts 21" to 36" in diameter, and 0.25" for ducts 37" to 60" in diameter. Rectangular Ductwork wall thickness shall be determined by substituting the long side for the round diameter. The inner surface shall contain a 20 mil thick C veil saturated with Hetron FR992 resin, (approx. 90% by weight resin). This will be followed by a 100 mil corrosion barrier (2 layers of 1-1/2 oz. chopped mat) with Hetron FR992 resin. The structural layer shall be as required for design service and shall be filament wound using resin as detailed in paragraph 2. Duct exterior shall have a relatively smooth surface free of exposed fibers and shall contain an ultraviolet inhibiting agent. All resin and joint material is suitable for a 250ºF service. When specified, double wall pre-insulated (20S-IR7) duct shall be furnished where indicated on the bid drawings. Construction will comply with PS standards and include 1" of insulation, with a K factor of 0.14 and an R value of 7. INSTALLATION Field joints shall be butt-type wet lay-up method. Flanged connections shall be provided where indicated on the contract drawings. Both of these joining methods are of the same material as the duct, thus forming a continuous FRP component system. Manufacturer s installation instructions to be followed. Overhead ductwork, when exposed, shall be manufactured incorporating a color selected by the Architect. Underground duct shall be manufactured as above and with an additional OD resin rich veil. For assistance in resin selection for specific corrosive environments * contact Perry Fiberglass Products, Inc.
4 Perry Fiberglass FRP duct products are as versatile and varied as the industries they serve. The wide range of configurations available ensures that we have duct products to meet your needs. PRODUCT OFFERINGS Perry Fiberglass offers two main categories of FRP duct products: single wall and pre-insulated double wall. SINGLE WALL Perry 20S Low Smoke, our Class 1 rated single wall duct, meets 25/50 flame/smoke requirements of UL 181. Perry 20S Low Smoke is unique in the industry and has found wide acceptance for both industrial and commercial projects. It is especially desirable in corrosive environments where flame and smoke development is a concern. PRE-INSULATED DOUBLE WALL If thermal control is a concern, then Perry 20S-IR7 pre-insulated double wall duct solves the problem. When supplied with the standard 1" insulation thickness, our double wall duct has a k factor of 0.14 and an R value of 7. The same corrosion resistant qualities can be maintained on both the ID and OD. Also available in R-5, R-10, R-14 or as specified. FIGURE 1 Typical Duct Shapes from Perry Fiberglass [Custom shapes available upon request.] ROUND RECTANGULAR OVAL CONFIGURATION OPTIONS SHAPE (SEE FIGURE 1) Typical shapes for filament wound construction are round, rectangular and oval. Special shapes such as triangular are also available. Engineering assistance is available for designing projects requiring non-standard construction. DIAMETER Duct diameters are available from 2" 144". Rectangular sizes are available as required for your projects. The same range of sizes are available in Perry 20S-IR7 pre-insulated double wall duct. WALL THICKNESS Duct wall thickness ranges from 1/8" to 1" (increasing in increments of 1/16"). Other wall thicknesses are available for abnormal burial depths or other special loading requirements. Standard ductwork is furnished with the following minimum wall thickness as set forth in PS and SMACNA: Diameter Wall Thickness 2" to 20".125 inches 21" to 36".187 inches 37" to 60".250 inches LENGTHS Standard length is 10'-0". Lengths up to 50 feet are available. FITTINGS (SEE FIGURE 2) Standard fittings include: Elbows Dampers Blastgates Tees Register Boxes Access Doors Laterals Square to Rounds Stacks Y s Crosses Caps Reducers Flanges Hoods COLORS A wide range of colors is available for overhead exposed applications. Please refer to the supplemental color chart for complete details. CONFIGURATIONS
5 FIGURE 2 Typical Duct Fittings from Perry Fiberglass [Custom fittings available upon request.] 61º 90º EL Long Radius 31º 60º EL Cross 90 Tee Y Lateral Eccentric Reducer Concentric Reducer Square to Round SPECIFICATIONS Perry Fiberglass FRP duct is manufactured from premium grade resins, filament wound over steel mandrels. This product meets the standards of UL 181, NFPA 90A and Uniform Mechanical Code (UMC) 10-1 for non-metallic ducts. Perry 20S Low Smoke duct is classified as a Class 1 air duct having a flame spread not over 25, and a smoke development rating not over 50. ASTM E84 (recognized by all as the most definitive of all fire test methods) tests were made by HPVA Laboratory and Testing Service, Reston, VA. HPVA is a recognized laboratory for the E84 fire rating test by the building code organizations under the Council of American Building Officials: Report No. Ner-TL329; ICBO; BOCA and SBCCI. Perry Fiberglass duct is fabricated to meet the requirements of National Bureau of Standards Voluntary Product Standard PS 15-69, SMACNA, ASTM D-2310 and ASTM D-2996 for establishing wall thickness, pressure capacity, and quality of fabrication. This summary is provided as an overview of the strict standards that Perry Fiberglass meets with the production of all our products. Complete technical specifications are available upon request for all Perry Fiberglass products. & SPECS
6 INSTALLATION & JOINING Perry Fiberglass FRP duct is easy to configure and install. Our ducts can be installed overhead or directly buried into a pea gravel backfilled trench without concrete encasement. Duct supports/hangers should be per recognized standards such as SMACNA or ASTM D In general, spacing is 8 12 feet dependent upon diameter and loading factors. Supports should be a minimum 120 degrees of diameter. Particular attention should be given to properly design supports and hangers to avoid point loading. INSTALLATION & JOINING Basic installation of Perry Fiberglass FRP duct is quick, easy, and economical. FIELD WET LAY-UP JOINT INSTRUCTIONS (SEE FIGURES 3, 4, & 5) This requires joining duct and/or fittings with resin and fiberglass mat. See separate Joining Procedures for complete details. Wet field joints shall be a minimum four (4) inches in width and at least the same thickness as adjoining duct wall. Butted sections may be tabbed/hot patched to hold alignment until a complete joint can be made. Note: Leak test the system before placing into service. BELL AND SPIGOT CONNECTION (SEE FIGURES 3, 4, & 5) This requires joining duct and/or fittings with resin and fiberglass mat and additionally filling the bell gap with putty. See separate Joining Procedures for complete details. FLANGED CONNECTION Flanges are furnished undrilled for field drilling to match equipment. Flanges are furnished factory mounted or as loose stub flanges. Flange connections should be gasketed per architect s/engineer s specification.
7 FIGURE 3 Preparation of Strapping [Complete instructions available upon request.] * Refer to manufacturer s joining procedures. 1" OVERLAP SIDES AND ENDS LAY UP ON RELEASE FILM 1 1/2 oz/ft 2 CHOPPED STRAND MAT FIBERGLASS MAT IMPREGNATED WITH RESIN TO FORM AN INTEGRAL UNIT FOR BUTT AND STRAP FIELD JOINTS. 4" WIDTH FIRST PLY EQUAL OVERLAP ON EACH SIDE FIGURE 4 Application of Strapping [Complete instructions available upon request.] * Refer to manufacturer s joining procedures. GLASS / RESIN WRAP BLEND AREAS THICKNESS OF OVER WRAP SHOULD BE EQUAL TO OR GREATER THAN THE THICKNESS OF THE FRP DUCT. FIGURE 5 Butt and Strap End to End Joint [Complete instructions available upon request.] * Refer to manufacturer s joining procedures. APPLY TOP COAT FOR APPEARANCE MULTIPLE PLIES WITH THE THICKNESS OF WRAP EQUAL TO OR THICKER THAN THE FRP DUCT OVERLAP ENDS A MINIMUM OF 4 INCHES LARGER DIAMETERS MAY BE WRAPPED WITH MULTIPLE SECTIONS
8 Perry Fiberglass Products, Inc Pin Oak Parkway Avon Lake, Ohio Phone: Fax: On-line:
San Antonio Water System Standard Specifications for Construction ITEM NO. 1100 SLIP-LINING SANITARY SEWERS
ITEM NO. 1100 SLIP-LINING SANITARY SEWERS 1100.1 DESCRIPTION: This item shall consist of slip-lining sanitary sewer pipe, which is accomplished by pulling or pushing liner pipe into existing sewers by
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES
ENGINEERING SPECIFICATION PULTRUDED DYNARAIL FIBERGLASS LADDER & LADDER CAGES PART 1 - GENERAL 1.1 SCOPE OF WORK SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED SQUARE TUBE LADDER
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
SECTION 15190 HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section 15010.
SECTION 15190 HVAC INSULATION PART ONE - GENERAL PART 1 - GENERAL 1.01 DESCRIPTION A. All work specified in this Section is subject to the provisions of Section 15010. B. All insulation products shall
07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
B. Types of mechanical insulation specified in this section include the following:
SECTION 23 0700 HVAC INSULATION PART 1 - GENERAL 1.1 SUMMARY A. Extent of mechanical insulation required by this section is indicated on drawings and schedules, and by requirements of this section. B.
All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.
DIVISION 15 MECHANICAL SECTION 15100 - PLUMBING PART 1 - GENERAL SCOPE Plumbing work includes all domestic water, gas, and sanitary sewer systems as shown on plans. Also all fixtures and equipment which
Joining and Bonding Procedures For Resin Based FRP Equipment
Joining and Bonding Procedures For Resin Based FRP Equipment VIRON INTERNATIONAL CORPORATION 989 723 8255 Introduction The bonding of FRP ductwork is a process requiring some degree of skill, which can
SECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.
SUBDRAINS AND FOOTING DRAIN COLLECTORS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Subdrains B. Subdrain Cleanouts and Outlets C. Footing Drain Collectors D. Storm Sewer Service and Connections 1.02 DESCRIPTION
Underwriters Laboratories Testing Information
Underwriters Laboratories Testing Information R-8078 Underwriters Laboratories Inc. R-13173 Classified Spray Fiber Surface burning characteristics applied to inorganic reinforced cement board with a maximum
CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements
16600 Underground Electrical Duct Bank This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24, 2014 06610-1
ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING January 24, 2014 06610-1 SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS MOLDED GRATING PART 1 - GENERAL 1.1 SCOPE OF WORK A. The CONTRACTOR
SECTION 16402 UNDERGROUND ELECTRIC SERVICE
SECTION 16402 UNDERGROUND ELECTRIC SERVICE PART 1 GENERAL 1.1 SUMMARY A. Description of System 1. Furnish all labor, materials, and equipment for below grade work external to buildings as required, and
CHAPTER 7: Building Systems ROOFING SYSTEMS
ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen
FINAL December 2012 SECTION 233100 DUCTWORK
SECTION 233100 DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insula tion shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation
Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems
Pipe and Equipment Insulations Zeston PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems Zeston PVC Insulated Fitting Covers Installation Instructions for Hot,
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES. July 1, 2008 Revision 2
ENGINEERING SPECIFICATION PULTRUDED DYNAFORM FIBERGLASS STRUCTURAL SHAPES 1 PART 1 - GENERAL 1.0 GENERAL 1.1 REFERENCES: SECTION 06610 FIBERGLASS REINFORCED PLASTICS (FRP) FABRICATIONS PULTRUDED FIBERGLASS
GreenGuard Housewrap Installation Guide
000768PACBPHW_Flashing Bro 5/23/03 2:52 PM Page 1 For the most current product information, go to www.green-guard.com. Pactiv Building Products believes the information and recommendations herein to be
DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION
SECTION 230713- ALUMAGUARD ENGINEER SPECIFICATION DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,
SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
Section 02702 SEWER PIPE INSTALLATION AND TESTING
PART 1 - GENERAL Section 02702 SEWER PIPE INSTALLATION AND TESTING 1-1. SCOPE. This section covers the installation and testing of all sewer pipe furnished under the following specification sections: Concrete
foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.
Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12
How To Repair A Steel Pier With A Watertight Frame
INNOVATIVE FRP PILING REPAIR WITHOUT THE USE OF COFFER DAMS Steve Bazinet, Larry Cercone, Franz Worth Air Logistics Corporation Field-Applied Composite Systems Group Pasadena, California 91107 ABSTRACT
Secondary Containment Options for Aboveground and Underground Tanks. Wayne Geyer Steel Tank Institute
Secondary Containment Options for Aboveground and Underground Tanks Wayne Geyer Steel Tank Institute Secondary containment tanks first appeared in the United States in the early 1980's, when several local
B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Scepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW
Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS
Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS TABLE OF CONTENTS I. RULES AND REGULATIONS A. TABLE OF CONTENTS... 2 B. TERMS AND DEFINITIONS... 3 C. DEVELOPER S/CONTRACTOR S RESPONSIBILITIES...
Best Available Technology for Sodium Hypochlorite Storage Tanks
Best Available Technology for Sodium Hypochlorite Storage Tanks Michael G. Stevens, Senior Staff Scientist, Ashland Inc. Paul Cohen, Diamond Fiberglass ABSTRACT Sodium hypochlorite disinfection has become
Fire Barrier Duct Wrap 15A
3 Fire Barrier Duct Wrap 15A Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions Compliance 1998 Edition Complies with International Mechanical Code Complies
Green Thread Product Data
Green Thread Product Data Applications Dilute Acids Caustics Produced Water Industrial Waste Hot Water Condensate Return Materials and Construction All pipe manufactured by filament winding process using
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA
Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,
Flowtite Jacking Pipe
U.S. COMPOSITE PIPE SOUTH, LLC. MEMBER OF KTI PIPE GROUP OF COMPANIES Flowtite Jacking Pipe 18585 Samuels Rd. Zachary, La. 70791 PH. 225-658-6166 Fax 225-658-0947 www.flowtitepipe.com Flowtite GRP Pipe
GUIDELINE SPECIFICATIONS
GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced
Fabricated Drainage Products
Fabricated Drainage Products Complete Drainage System Inline Drains are used At the beginning of a drain line Add a new water inlet to an existing drain line using a riser pipe and tee HARCO Surface Drainage
SECTION 07400 STANDING SEAM METAL ROOF
SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and
HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA
HVAC Air Duct Leakage Eli P. Howard, III Group Director Technical Resources SMACNA Key Variables that Affect the Amount of Leakage Static Pressure Amount of Duct Openings in the Duct Surface Seams, Joints,
Fiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
Native InDesign 2890 SaniTite Brochure 1/8" 100 300 CMYK April 17, 07
Sanitary Sewer Pipe Tough pipe for a tough environment SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling, toughness
Preformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
4 Installation Requirements
4 Installation Requirements 9 4.1 Code Reference The authority having jurisdiction should be referenced to determine what law, ordinance or code shall apply in the use of flexible duct. Ducts conforming
Roof Curbs, Extensions and Equipment Supports
Roof s, Extensions and Equipment Supports December 2012 Roof Page s, Header Extensions and Equipment Supports Table of Contents Model GPI Standard and Optional Construction Features... 3 Model Number Code....
SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS
SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials
External Wrapping of Steel Riser Pipe. Case Study HJ3 CS200902
External Wrapping of Steel Riser Pipe Case Study HJ3 CS200902 Introduction Refineries process a wide variety of petroleum products. As part of the process, they rely on cooling towers, which recycle water
List of Frequently Utilized Storage Tank Standards and Practices
List of Frequently Utilized Storage Tank Standards and Practices Below is a list of frequently used storage tank standards and practices from organizations that are referenced in 25 PA Code, Chapter 245.
PART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES
SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES 4121 N.W. 37 th Street, Lincoln, NE 68524 Telephone (402) 470-2627 Fax (404) 470-2410 www.gtexhaust.com
DIVISION 4300 STORM DRAINAGE
DIVISION 4300 STORM DRAINAGE SECTION 4305 STORM SEWER PART 1 - GENERAL 1.01 SCOPE This section covers the construction of storm sewers for the collection and transport of stormwater runoff. 1.02 REFERENCES
SECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
Oil and Gas Pipeline Design, Maintenance and Repair
Oil and Gas Pipeline Design, Maintenance and Repair Dr. Abdel-Alim Hashem Professor of Petroleum Engineering Mining, Petroleum & Metallurgical Eng. Dept. Faculty of Engineering Cairo University [email protected]
All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD
SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation
SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS
SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING
Automatic Door Selection Guide
Automatic Door Selection Guide AAADM 1300 Sumner Avenue Cleveland, OH 44115 P: 216-241-7333 F: 216-241-0105 [email protected] Automatic Door Selection Guide General: The members of AAADM manufacture an assortment
Product Guide Specification
Reef Industries, Inc. 9209 Almeda Genoa Rd. Houston, Texas 77075 Toll Free (800) 231-6074 Phone (713) 507-4251 Fax (713) 507-4295 Web Site www.reefindustries.com E-Mail [email protected] Product Guide
Removable Insulation Blankets from A to Z
Removable Insulation Blankets from A to Z At first glance, making up a removable insulation blanket seems somewhat simple take some insulation, put some mesh on one side, a cover on the other, sew them
FIBERGLASS REINFORCED PLASTIC (FRP) PIPING SYSTEMS DESIGNING PROCESS / FACILITIES PIPING SYSTEMS WITH FRP
FIBERGLASS REINFORCED PLASTIC (FRP) PIPING SYSTEMS DESIGNING PROCESS / FACILITIES PIPING SYSTEMS WITH FRP A COMPARISON TO TRADITIONAL METALLIC MATERIALS Prepared by: Kevin Schmit, Project Engineer Specialty
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes
CANTEX INC. 301 Commerce Ste 2700 Fort Worth, Texas 76102 817-215-7000 Fax: 817-215-7001 Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes YOUR FULL
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS
State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS While its use is not required, this checklist has been prepared to provide the field inspector a summary
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION
The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe
The Most Advanced Name in Drainage Systems Sanitary Sewer Pipe SaniTite Sanitary Sewer Pipe delivers the features that engineers, contractors and municipalities demand durability, performance, handling,
INDEX. Sec. No. Items Page Nos.
INDEX Sec. No. Items Page Nos. 1. Types of Pipe............... MSSP- 2 2. Concrete Pipe............... MSSP- 2 thru MSSP-3 3. ABS and PVC Truss Pipe............... MSSP- 3 4. ABS and PVC Solid Wall Pipe...............
James M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines
EXHIBIT "A Technical Specifications for Water and Sewer Service Lines Water and Sewer Line Bedding and Backfill: Drawings show cross-section of trench, pipe laid on top of 6" min. bedding material, bedding
Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association
Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-
TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL. 23 21 13.19 Pre-Insulated Piping 4-8-13
TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL 23 21 13.19 Pre-Insulated Piping 4-8-13 MATERIAL SUBMITTAL JOB NAME: TEXAS A&M SAN ANTONIO CENTRAL ACADEMIC BUILDING & PATRIOTS CASA CONTRACTOR:
Product Information Sheet
Distributed by Thermal Products Company, Inc. Product Information Sheet FyreWrap Elite 1.5 Duct Insulation Air Distribution System (ADS Ducts) Introduction Unifrax s FyreWrap Elite 1.5 Duct Insulation
SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section 02250.
02150-1 of 6 SECTION 02150 REMOVAL OR ABANDONMENT OF EXISTING 02150.01 GENERAL A. Description Removal or abandonment of existing utilities and underground structures shall include, but not necessarily
GAS INSTALLERS MANUAL CINERGY AND SUBSIDIARY COMPANIES CUSTOMER PROCEDURE FOR INSTALLING 3", 4", 6", AND 8" IPS PLASTIC GAS SERVICE PIPING
CINERGY AND SUBSIDIARY COMPANIES CUSTOMER PROCEDURE FOR INSTALLING 3", 4", 6", AND 8" IMPORTANT TELEPHONE NUMBERS IPS PLASTIC GAS SERVICE PIPING Cinergy Gas & Electric Services For information regarding
City of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
SECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner
The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional
Fabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1" 1.5" x 1.
Features: Will not rust. Corrosion resistant. Non-sparking. Fire retardant. Non-conductive. Maintenance free. Molded-in color. Light weight. Easy to install. Impact resistant. Quality appearance. Fabcograte
How To Compare Roofing Material
Roofing Material Comparisons Housing Fact Sheets One of the great strengths of our market economy is the number of product choices we are provided with. So when it comes time to replace the roof on your
COMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
COATING & WRAPPING OF UNDERGROUND PIPING
CONSTRUCTION STANDARD SPECIFICATION DOCUMENT NO :SEC-PJ-000-SPC-PI-008 TOTAL PAGES : 8 Page 1 of 8 CONTENTS 1. SCOPE 2. DEFINITION 3. CODES AND STANDARDS 4. MATERIALS Page 2 of 8 1. SCOPE This specification
LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m
FIREX Interlock Armored Cables TECK90 and MC Industrial Cables LEAD FREE O V E R 1 8 0 Y E A R S O F E X P E R I E N C E 866-663-9267 w w w. n e x a n s e n e r g y. c o m Interlock Armored Cables Introduction....2
ASX7-4-IOM-7 J30-08579
INSTALLATION INSTRUCTIONS 4" COMBUSTION AIR INLET KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 30,000 to 75,000 BTU/HR SUPPLEMENT
SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD
SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD 21.01 SCOPE: It is the intent of the Specification to define the approved methods and materials
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
WATER & SEWER CORROSIVE RESISTANT PRODUCTS
WATER & SEWER CORROSIVE RESISTANT PRODUCTS The Standard of Excellence in the Industry CASING SPACERS COUPLINGS & FLANGE COUPLING ADAPTERS REPAIR CLAMPS DUCTILE IRON SADDLES STAINLESS STEEL SADDLES TAPPING
Solid-Cast Versus Resin-Encapsulated Transformers
Data Bulletin 7300DB0402 12/2004 Monroe, NC USA Replaces 7300PD9202, 02/1992 Solid-Cast Versus Resin-Encapsulated Transformers Class 7300 Retain for future use. OVERVIEW The continuing development of dry-type
SECTION 02400 - STORM DRAIN SYSTEM
SECTION 02400 - STORM DRAIN SYSTEM CONTENTS: Part 1 - General... 1 1.01 Work Included... 1 1.02 Related Requirements... 1 1.03 Reference Standards... 1 1.04 Quality Assurance... 1 1.05 Measurement And
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)
SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701) 55-1 GENERAL The Contractor shall perform all work required by the plans for construction of pipe for storm drains, precast polymer trench drains
3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.
The following shall serve as the minimum requirements for contractors performing work in relation to the Authority s potable water and sanitary sewer system(s), appurtenances and service connections. General:
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL
DIVISION 2 - SEWERAGE AND DRAINAGE SECTION 02720 - STORM DRAIN SYSTEMS PART 1 - GENERAL 1.01 DESCRIPTION A. Furnish and install all storm drains, including manholes, inlets, service lines and other appurtenant
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
MOBILE HOME SERVICE REQUIREMENTS GAS
ELECTRIC AND GAS 1.0 INDEX 1.0 INDEX 2.0 PURPOSE 3.0 GENERAL 4.0 REFERENCE MATERIAL 5.0 TYPICAL UNDERGROUND UTILITY LAYOUT 6.0 METER PAD DETAILS 7.0 GENERAL INSTALLATION PROCEDURES 8.0 PEDESTAL SPECIFICATIONS
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING
SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,
Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: [email protected]. The Passive Fire Protection Specialists
Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
Seamless stainless tubes for hydraulic and instrumentation systems
Seamless stainless tubes for hydraulic and instrumentation systems stock assortment integrated production technical knowledge network of sales and service Reduce your lifecycle costs When selecting tubes
Pipe Protection Tape System
Pipe Protection Tape System PASCO All Weather Pipe Protection Tape is a pure physical barrier that is moisture proof, inert and non-conducting. Whether the need is to protect overhead piping in industrial
SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 *
SFI SPECIFICATION 28.1 EFFECTIVE: SEPTEMBER 23, 2011 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards