VGA INPUT MONITOR OUT VGA INPUT MONITOR OUT 3.5mm STEREO MINI 3.5mm STEREO MINI L R Audio L R Audio AUDIO INPUTS + - + - AUDIO INPUTS + - + - AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V AMPLIFIED OUTPUT 4/8 ohm COM 70V 100V Serial Data Grade Cables Data... Delivered. Serial digital systems such as RS-232, RS-422, and RS-485 require digital signals to be delivered from component to component with minimal distortion. West Penn Wire serial data grade cables are manufactured with low loss insulation providing superior electrical characteristics with either single or dual shields. When the application calls for digital 1s and 0s, graduate to the level of serial data grade. To additional Doors A A FEATURES Superior electrical characteristics Low Loss s Superior RS-232 Applications RS-422 Applications RS-485 Applications 1-1000ft Incremental Footage Markers Advantage Box Packaging MINI INDEX A Non- Low Cables Multiple Pair/ Overall Shield.. 1 Multiple Pair Series/ Individually Shielded... 2 Low Cables Multiple Pair Series/ Overall Shielded.... 3 Multiple Pair Series/ Individually Shielded... 2 DB9 Connectors and Assemblies 4 RS-485 Cables Non- RS-485 5 RS-485 6
Serial Data Grade Cable ASTM Tinned Copper insulation Overall shield coverage of aluminum polyester foil with strd. TC Twisted Pair Construction Overall jacket CM Meets 300V requirements as specified in the Flame UL1685 D2401 D2402 D2404 of 1 Pair 2 Pair 4 Pair Coverage O.D. Data Grade Cable Multiple Pair / Overall Shielded.160 CM.228 CM.268 CM Indoor for: Control Signaling Electronic Data Microprocessor Based Serial Data DMX Audio RS-485 RS-232 14.5pf/ft* 26pf/ft ** 14.5pf/ft* 26pf/ft ** 14.5pf/ft* 26pf/ft ** D3651 2 Pair.235 CM 26pf/ft* 47pf/ft ** D3653 4 Pair Code Pair s 1 Black/Red 2 Black/White 3 Black/Green 4 Black/Blue JACKET: Cables are packaged in the Advantage Box. Orange ripcord included on cables containing 3 or more pairs..268 CM 26pf/ft* 47pf/ft ** Vel of Propagation - 66% Impedance Ω 24 Awg.- 100Ω Impedance Ω 22 Awg.- 55Ω * between conductors. ** between one conductor and the 1
Serial Data Grade Cable Data Grade Cable Multiple Pair Series / Individually Shielded Indoor for: Control Signaling Electronic Data Microprocessor Based Serial Data of D420 2 Code Pair Solid 17.5 Ω/Mft s 1 Black/Yellow 2 Red/Green JACKET: ASTM Tinned Copper insulation Each pair shielded coverage of aluminum foil with Strd. TC Twisted pair construction Overall CM Meets 300V requirements as specified in the Flame UL1685 Coverage O.D. Individual.261 CM 15.5 pf/ft* 28 pf/ft** * between conductors. ** between one conductor and the Data Grade Cable Multiple Pair Series / Individually Shielded CMP (UL)-C(UL) Listed or c(etl)us Listed Meets 300V requirements as specified in the Flame NFPA-262 Smoke Flame Test of D25420 2 Solid 17.5 Ω/Mft Drain wire Solid Tinned copper Cables are packaged in the Advantage Box. Coverage ASTM Tinned Copper insulation Each pair shielded coverage of aluminum foil with Strd. Twisted pair construction plenum jacket O.D..012 Individual PVDF.185 CMP 15.5 pf/ft* 28 pf/ft** Vel of Propagation - 66% Impedance Ω D420 D25420-100Ω * between conductors. ** between one conductor and the 2
Serial Data Grade Cable ASTM Tinned Copper Overall shield coverage of aluminum polyester foil with 24 Awg. Strd. drain wire Twisted Pair Construction plenum jacket CMP (UL)-C(UL) Listed or c(etl)us Listed Meets 300V requirements as specified in the Flame NFPA-262 Smoke Flame Test of D252401 1 D252402 2 D252404 4 D253651 2 D253652 3 D253653 4 Code Pair s 1 Black/Red 2 Black/White 3 Black/Green 4 Black/Blue JACKET: Coverage Data Grade Cable Multiple Pair Series / Overall Shielded O.D. Indoor within ducts,plenums and other spaces used for environmental air: Control Signaling Electronic Data Microprocessor Based Serial Data.115 CMP.188 CMP.224 CMP.191 CMP.204 CMP.224 CMP 14.5 pf/ft* 26 pf/ft** 14.5 pf/ft* 26 pf/ft** 14.5 pf/ft* 26 pf/ft** 25 pf/ft* 45 pf/ft** 25 pf/ft* 45 pf/ft** 25 pf/ft* 45 pf/ft** Vel of Propagation - 69% Impedance Ω 24 Awg.- 100Ω Impedance Ω 22 Awg.- 55Ω * between conductors. ** between one conductor and the Cables are packaged in the Advantage Box. - Dupont Tradename for FEP-Fluorinated Ethylene Propylene Installation Precautions see Technical Reference Section Page 192 3
RS-485 Non- SERIAL DATA CONTORS DB9 DB9 Terminal Block Connectors Description CN-MX9F CN-MX9M CN-MX915H PREMIUM DB9 (F) Terminal Block RS-232 PREMIUM DB9 (M) Terminal Block- RS-232 Hood for PREMIUM Terminal Blocks CN-MX9M With Hood CN-MX915H SERIAL DATA CONTORS DB9 Assemblies DB9 Assemblies - Non- Description CND2404DB9-xx CND2404FF9-xx CND2404MF9-xx DB9 M to DB9 M -xx: 6,10,15,25 ft DB9 F to DB9 F -xx: 6,10,15,25 ft DB9 M to DB9 F -xx: 6,10,15,25 ft DB9 Assemblies - Description CND252404DB9xx DB9 M to DB9 M -xx: 6,10,15,25 ft CND252404FF9xx DB9 F to DB9 F -xx: 6,10,15,25 ft CND252404MF9-xx DB9 M to DB9 F -xx: 6,10,15,25 ft Other lengths are available upon Request 4
RS-485 Indoor for: Computer Application Low Data RS-485 Data Applications Data Grade Cable Multiple Pair Series / Overall Shielded RS-485 Data Cables ASTM Tinned Copper Twisted pair construction Polyester wrap Overall shield coverage of aluminum polyester foil with 24 Awg. Stranded Tinned Copper Braid Overall of D4851 1 D4852 2 D4853 3 D4854 4 Code Pair s 1 Blue- White 2 Orange- White 3 Green- White 4 Brown- White JACKET: CM Meets 300V requirements as specified in the Flame UL1685 Coverage O.D. - with - with - with - with.275 CM.305 CM.320 CM.345 CM Vel of Propagation - 66% Impedance Ω 24 Awg.- 120Ω * between conductors. ** between one conductor and the 5
RS-485 Data Grade Cable Multiple Pair Series / Overall Shielded RS-485 Data Cables ASTM Tinned Copper Foam Twisted Pair Construction Polyester wrap Overall shield coverage of aluminum polyester foil with 24 Awg. Stranded Tinned Copper Braid Overall CMP Meets 300V requirements as specified in the Flame NFPA-262 Smoke Flame Test Indoor within ducts,plenums and other spaces used for environmental air: Computer Application Low Data RS-485 Data Applications of Coverage O.D. D254851 1 Foam - with Flex..017.202 CMP 12 pf/ft* 22 pf/ft** D254852 2 Foam - with Flex..017.305 CMP 12 pf/ft* 22 pf/ft** Vel of Propagation - 76% Impedance Ω 24 Awg.- 120Ω Code Pair s 1 Blue- White 2 Orange- White JACKET: * between conductors. ** between one conductor and the - Dupont Tradename for FEP-Fluorinated Ethylene Propylene 6