CE6500 Energy Recovery Ventilator



Similar documents
Mechanical Rooftop Custom Capabilities

Bring the fresh in. Dedicated Outside Air Systems

Operation and Installation Manual. Max Series

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Commercial Gas Furnace Upflow

Innovent LASER Packaged Fresh Air Conditioning Units

Johnson Air-Rotation Systems

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Element D Services Heating, Ventilating, and Air Conditioning

SECTION MORTUARY REFRIGERATORS

Zehnder Focus 200. Ventilation device

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

RPV - RP - RA air handling units

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

DDC Controls Package Manual

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

Heating oven with mechanical convection

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

PLUG and PLAY VRV Connection

SWIMMING POOL HEAT PUMP Owners Manual

ECOCIAT. Domestic hot water heat recovery unit

Cooling Capacity CFM in. w.c. (125 Pa)

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Single Package Vertical Air Conditioners. Vert-I-Pak

Variable Air Volume - VAV

Heating oven with mechanical control

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

Explosion-Proof Electric Unit Heaters

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

CHILLED WATER DATA ROOM UNITS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Installation Manual CLIFC Fan & Coil Variable Speed

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

SECTION AIR CONDITIONING UNIT

CADB and CADT-D / DI / DC Series

TWE+TTA TWE+TWA T.R.

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation and maintenance instructions. Danfoss Vent

Material test chamber with mechanical convection

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

ENHANCED LABORATORY HVAC SYSTEM

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

GTS Gas-to-Steam Humidification System

Modular Make-Up Air Unit

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

SECTION HEAT PUMPS

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

CoolTeg Plus Chilled Water (CW) version: AC-TCW


Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Energy Efficiency HOSPITALITY.

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Cased/Uncased Coils For Gas And Oil Furnaces

HVAC Processes. Lecture 7

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Evaluate, Clean, and Tune Guidance

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Direct Gas-Fired Indoor and Outdoor Heating and Make-Up Air Units

Thyristor-controlled power supplies and battery chargers

Incubator with mechanical convection

F9MXE. Product Specifications

PMI-IF-H High Efficiency Gas Heat Units

ROOF TOP MOUNTED Air Handler Specification

Installation Instructions

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Electronic Control Devices The European Product Catalogue 2007

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Packaged Cooling with Electric Heat Rooftop Units

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

york air-conditioning products Residential & VRF News 2015

GCS16 GCS20 WARNING CAUTION

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

How To Get A Passive House

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

GCS

Ventilation System Air Conditioner SVC MANUAL(Exploded View)

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

FOXAIR 60/50 ALL MODELS

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Energy Efficiency. Bars & RestauRants.

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Transcription:

ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge galvanized steel interior walls Access doors with quarter-turn handles -gauge stainless steel drain pan Drain Connections: 1 NPT Insulation: MOUNTING On roof curb or on platform Interior Unit i PLATE EXCHANGER Material: Enthalpy Quantity: 2 Pitch: 0.13 (3.3 mm) Dimensions: 30 x 30 x 27.5 (762 mm x 762 mm x 699 mm) BLOWERS Quantity: 2 Forward-curved Permanently sealed and lubricated ball bearings Power transmission by adjustable pulleys and belts Exterior Unit e MOTORS Type: Inverter duty 10:1, ODP or TEFC, EPAct or Premium Maximum Power: 10 hp Drive Assembly/Blower: On vibration-isolating springs FILTERS Type: MERV 8 Quantity: 6 per circuit Dimensions: 16 x 20 x 4 (406 mm x 508 mm x 102 mm) ELECTRICAL & CONTROLS Start/stop dry contact and general alarm dry contact Occupancy control dry contact Fan interlock dry contact 24VAC, 20VA power available for accessories Access panel with non-fused disconnect (NEMA 4) Single-point power connection 120, 208, 230 V / 1ph / 60Hz 208, 230, 460, 575 V / 3ph / 60Hz WARNTY Core: Limited 10-year warranty All Other Covered Components: Limited 2-year warranty LISTED BY

2 al Features FROST PREVENTION/CONTROL OPTIONS Frost control activated by a temperature reference Set point: 14 F (-10 C) Internal Pre-Heat by Electric Coil: Powered by unit Factory calibrated SCR control Internal Pre-Heat by Hot Water Coil: 0-10 V signal on the control panel Front or back piping connections Internal Face and Bypass Damper: Fresh air deviation Defrost Cycles: Exhaust Only or Recirculation Comes with motorized and insulated damper on OA only See table below for temperature references Exchange Period (Minutes) 35 30 25 20 15 10 Defrost Cycle Exchange Period - -13-4 5 14 23 (-30) (-25) (-20) (-15) (-10) (-5) Outside Air Temperature in ºF (ºC) Cycles (7-Minute Defrost) AVAILABLE OPTIONS Cabinet s: Supply and Exhaust Hoods with bird screens Roof Curb: 14 (356 mm) high, -gauge galvanized steel, insulation optional Front or back piping connections (drain pan and water coil and/or cooling connections) Pool Construction: TEFC motors, stainless steel interior, and epoxy-coated fans (NOTE: ERV not recommended for indoor pool applications) AVAILABLE OPTIONS Components s: Final MERV 13 filters added to the fresh air circuit Motorized and insulated dampers (on OA and/or EA openings) Non-insulated backdraft damper (on EA opening only) Post-Heat by Electric Coil: Powered by unit Post-Heat by Hot Water Coil: 0-10VDC signal to maintain supply air temperature, or 0-10VDC signal by others Cold Water Cooling Coil: Control by others, comes with -gauge stainless steel drain pan DX Cooling Coil: All controls and condensation unit by others, comes with -gauge stainless steel drain pan Blower Motor s: TEFC, Premium (only available with 1.5 hp/ 3ph) 2-Speed motors (only available with ODP, EPAct motors) Programmable 2-Speed (VFD) Variable Frequency Drive (VFD), 0-10VDC control signal by others Backward-inclined blowers Control s: Economizer Cycle: Free cooling management by temperature sensor on OA (available with face and bypass damper only) Dirty Filters Contact: Will close a dry contact when dirty filters are detected Low Airflow Switch: Will open a dry contact when no airflow is detected on supply blower Low Temperature Limit: Unit will stop if fresh air supply is under set point (adjustable) for more than 5 minutes Phase Loss Detection: Unit will stop when a phase loss occurs, automatic restart (3-phase power only) Damper End Switch: Unit start up conditional to dampers opening Recirculation Dry Contact: For unoccupied mode, must select recirculation defrost option Terminals for OA and/or EA damper power and control (24VAC, 10VA): Included when OA/EA damper selected Programmable Timer C0 2 or Relative Humidity (RH) Sensor: Sequence of operations must be verified by factory BacNet Compatible Controller Available Upgrades:»» IP Communication Network Module»» MS/TP Communication Network Module»» Remote Keypad»» Remote Keypad with Touchscreen

3 Components & Configurations *Motorized Damper *Exhaust Hood *Supply Hood with bird screen *MERV 8 Filters *MERV 13 Filters *Pre-Heat Coil (electric or hot water) *Bypass Damper Recovery Core Exhaust Blower Motor A *Motorized Damper A *Recirculation Damper Control Panel MERV 8 Filters Drain Pan Drain 1 NPT, front connection (optional back connection) *Post-Cooling Coil (water), front connection (optional back connection) Motor Supply Blower *Post-Heat Coil (electric or hot water), front connection (optional back connection) Return Supply * = OPTIONAL FEATURE AVAILABLE CONFIGUTIONS 1-2-6-7 OA 1-3-5-7 1-3-6-7 1 1-2-5-7 Mirror Image Cabinet Also Available EA LEGEND 2 OA Return Air Supply Air Outside Air 3 7 EA Exhaust Air 5 6 Access internal components on this side.

4 Dimensions & Weights Unit BP** CABINET* Height Width Length A Overall 79.8 (2027) 79.8 (2027) B Base - 69.5 (1765) 81.5 (2070) 75.5 (19) 87.5 (23) Overall Overall - Overall - 1 Coil Overall - 2 Coils C D E D E D E Hoods 75.5 (19) 87.5 (23) Base - 141.3 (3589) 141.3 (3589) 147.3 (3741) 147.3 (3741) Motorized Exhaust Damper 151.8 (3856) 151.8 (3856) Hoods 7.1 (4752) 7.1 (4752) Base - 161.3 (4097) 161.3 (4097) 167.3 (4249) 167.3 (4249) Motorized Exhaust Damper option 171.8 (4364) 171.8 (4364) Hoods 207.1 (5260) 207.1 (5260) Base - 1.3 (4605) 1.3 (4605) 7.3 (4757) 7.3 (4757) Motorized Exhaust Damper 191.8 (72) 191.8 (72) Hoods 7.1 (5768) 7.1 (5768) V Front Clearance Required 64 (1626) 64 (1626) OPENINGS Unit F G H I J K L M N O P Q R S BP** 24 (610) 24 (610) 24 (610) 24 (610) N/A N/A N/A N/A * All dimensions in inches (mm) ** Unit with bypass damper OA F G I EA H K J S R A E D N O Q P Dimension V : Clearance required in front of the unit for access to the internal components. B C WEIGHT - Minimum 3607 lbs (1636 kg) Maximum 93 lbs (19 kg) WEIGHT - BP Minimum 4134 lbs (75 kg) Maximum 53 lbs (2412 kg) Actual weight may vary by ±10%. Shipping weight calculated after final selection. Roof curbs shipped separately.

5 Roof Curb Dimensions NOTE: Drawings not to scale -1/4 (464 mm) 9-1/ (241 mm) 21 (533 mm) (457 mm) 14 (356 mm) -3/8 (19 mm) (559 mm) 64-3/8 (1635 mm) Subtract 5-1/8 (130 mm) from Dimension D on Page 4 BP -1/4 (464 mm) 9-1/ (241 mm) 14 (356 mm) 27 (686 mm) (457 mm) -3/8 (19 mm) (559 mm) 76-3/8 (1940 mm) Subtract 5-1/8 (130 mm) from Dimension D on Page 4

6 Roof Curb Assembly Unit ROOF CURB WEIGHTS & DIMENSIONS Unit 3-7/8 (98 mm) Gasket (Not Included) Roof Curb Weight Shipping Weight 5 lbs (84 kg) 230 lbs (104 kg) 1/ (13 mm) Shipping Dimensions (W x H x D) 96 x 24 x 25 (2438 mm x 610 mm x 635 mm) Roof Membrane Roof Curb ROOF CURB WEIGHTS & DIMENSIONS Unit BP Rigid Insulation (Not Included) Roof Curb Weight Shipping Weight 215 lbs (98 kg) 260 lbs (1 kg) Building Frame Shipping Dimensions (W x H x D) 96 x 24 x 25 (2438 mm x 610 mm x 635 mm)

7 Enthalpy Core Performance AHRI STANDARD CONDITIONS Outside Temperature Winter CONDITIONS Summer AHRI STANDARD CONDITIONS Exhaust Air Temperature Winter CONDITIONS Summer Dry Bulb 35 F (1.7 C) 95 F (35 C) Dry Bulb 70 F (21.1 C) 75 F (23.9 C) Wet Bulb 33 F (0.6 C) 78 F (25.6 C) Wet Bulb 58 F (14.4 C) 63 F (17.2 C) Note: Efficiencies are based on AHRI standard winter conditions. 65 Enthalpy Core Efficiency Efficiency (%) 55 45 35 Sensible Winter-Total Winter-Latent Summer-Total Summer-Latent 25 5500 (9345) 5600 (9515) 5700 (9685) 5800 (9855) 5900 (10025) 6000 (10195) 6100 (10365) 6200 (10535) 6300 (10705) 6400 (10875) 6500 (11045) 6600 (11215) 6700 (11385) 6800 (11555) 6900 (11725) 7000 (195) Airflow in CFM (m 3 /h)

8 Motor Selection Enthalpy Core SUPPLY/EXHAUST EXTERNAL STATIC PRESSURE (IN H AIRFLOW 2 0) - SUPPLY/EXHAUST MOTOR 0.25 (60 Pa) 0.50 (125 Pa) 0.75 (5 Pa) 1.00 (250 Pa) 1.25 (310 Pa) 1.50 (375 Pa) CFM (m 3 /h) RPM BHP HP RPM BHP HP RPM BHP HP RPM BHP HP RPM BHP HP RPM BHP HP 5 hp 5500 (9345) 1007 4.07 4.88 1047 4.32 5. 1088 4.58 5.50 1129 4.84 5.81 1170 5.09 6.11 1211 5.35 6.42 5600 (9515) 1020 4.26 5.11 1059 4.51 5.41 1099 4.77 5.73 1139 5.04 6.05 10 5.30 6.36 10 5.56 6.67 5700 (9685) 1032 4.45 5.35 1071 4.71 5.65 1110 4.98 5.97 1150 5.25 6.30 1190 5.51 6.61 19 5.78 6.93 5800 (9855) 1045 4.66 5.59 1083 4.92 5.90 1121 5. 6. 1160 5.46 6.55 1200 5.73 6.88 1239 6.00 7.20 5900 (10025) 1058 4.87 5.85 1095 5.13 6.15 1133 5.40 6. 1171 5.68 6.81 1210 5.96 7.15 12 6.23 7. 7.5 hp 6000 (10195) 1072 5.09 6.11 1107 5.35 6.42 1144 5.62 6.75 12 5.90 7.08 10 6.19 7.42 1258 6.47 7.76 6100 (10365) 1085 5.31 6.38 1119 5.58 6.69 1156 5.85 7.02 1193 6.14 7.36 1230 6.43 7.71 1267 6.71 8.06 6200 (10535) 1098 5.54 6.65 1132 5.81 6.97 1167 6.09 7.30 1204 6.38 7.65 1240 6.67 8.00 1277 6.96 8.36 6300 (10705) 1111 5.78 6.94 1144 6.05 7.26 1179 6.33 7.60 1215 6.62 7.95 1251 6.92 8.31 1287 7. 8.66 6400 (10875) 1125 6.03 7.23 1157 6.30 7.56 1191 6.58 7.90 16 6.88 8.25 1261 7. 8.61 1297 7. 8.98 6500 (11045) 1138 6.23 7.54 1170 6.55 7.86 1203 6.84 8.21 1237 7.14 8.56 1272 7.44 8.93 1307 7.75 9.30 6600 (11215) 1152 6.54 7.85 13 6.81 8. 1215 7.10 8.52 1249 7.40 8.88 1283 7.71 9.26 1317 8.03 9.63 10 hp 6700 (11385) 1166 6.81 8.17 1196 7.08 8.50 17 7.37 8.85 1260 7.68 9.21 1294 7.99 9.59 1328 8.81 9.97 6800 (11555) 1179 7.08 8.50 1209 7.35 8.83 1240 7.65 9. 1272 7.96 9.55 1305 8.27 9.93 ND 6900 (11725) 1193 7.36 8.83 12 7.64 9.17 1252 7.94 9.53 1283 8.24 9.89 ND ND 7000 (195) 1207 7.65 9. 1235 7.93 9.52 1265 8.23 9.88 ND ND ND MOTOR 7.5 hp 10 hp ND NOTE: hp = bhp x 1.2 Additional Air Pressure Drop with MERV 13 Filters Airflow CFM (m 3 /h) APD in. H 2 O (Pa) Airflow CFM (m 3 /h) APD in. H 2 O (Pa) 5500 (9345) 0.20 (50) 5600 (9515) 0.21 (51) 5700 (9685) 0.21 (53) 5800 (9855) 0. (54) 5900 (10025) 0. (55) 6000 (10195) 0.23 (57) 6100 (10365) 0.23 (58) 6200 (10535) 0.24 (59) 6300 (10705) 0.24 (61) 6400 (10875) 0.25 (62) 6500 (11045) 0.25 (63) 6600 (11215) 0.26 (65) 6700 (11385) 0.27 (66) 6800 (11555) 0.27 (67) 6900 (11725) 0.28 (69) 7000 (195) 0.28 (70)

Selection Information = Feature = al Feature (check the box to select this option) Send finished selection to American ALDES. MODEL Series: Advanced Commercial (CE) Nominal Capacity: 5500-7000 CFM Application: Interior (i) Exterior (e) 9 CASING Cabinet Finish Painted Pool Construction Supply & Exhaust Hoods al (exterior models) Duct Configuration (see pg. 3) 1-2-6-7 1-3-5-7 1-3-6-7 1-2-5-7 Mirror Image Cabinet al Roof Curb (exterior models) None Insulated Non-Insulated Piping Connections Front Back ELECTRICAL REQUIREMENTS 120V/1ph/60Hz 208V/1ph/60Hz 230V/1ph/60Hz 208V/3ph/60Hz 230V/3ph/60Hz 460V/3ph/60Hz 575V/3ph/60Hz FILTERS MERV 8 MERV 13 (Final Filter) FROST CONTROL None Exhaust Defrost 1 Recirculation 1 Pre-Heat (Electric Coil) Pre-Heat (Hot Water Coil) Face & Bypass Damper BLOWERS & MOTORS Supply Blower 5 hp 10 hp 7.5 hp Exhaust Blower 5 hp 10 hp 7.5 hp Motor Type ODP, EPAct 2 ODP, Premium 3 TEFC, EPAct 2 TEFC, Premium 4 Blower Type Forward Curved Backward Inclined Blower Control Single Speed 2-Speed 5 Programmable 2-Speed (VFD) VFD HEATING OPTIONS None Post-Heat (Electric Coil) Post-Heat (Hot Water Coil) COOLING OPTIONS None Cold Water Cooling Coil DX Cooling Coil ADD-ONS Motorized & Insulated Damper for EA Non-Insulated Backdraft Damper for EA Motorized & Insulated Damper for OA 1 Terminals for OA and/or EA damper power and control (24VAC, 10VA) Low Temperature Limit Economizer Cycle Dirty Filters Contact Low Airflow Switch Phase Loss Detection Damper End Switch Recirculation Dry Contact 6 Programmable Timer CO 2 Sensor 7 Relative Humidity Sensor 7 BacNet Compatible Controller With IP Module With MS/TP Module With Remote Keypad With Remote Keypad (Touchscreen) Spare MERV 8 Filters QTY: Spare Belts QTY: 1 OA Motorized & Insulated Damper included with exhaust defrost and recirculation 2 EPAct efficiency only available when Premium efficiency is not available (e.g., with single-phase motors) 3 ODP, Premium only available with 3 hp/ 3ph motors 4 TEFC, Premium only available with 1.5 hp/ 3ph motors 5 2-Speed only available with ODP, EPAct motors 6 Recirculation Dry Contact requires selection of recirculation defrost 7 Sequence of operations must be verified by factory Project: Location: Model #: Quantity: Submitted By: Date: Architect: Engineer: Contractor: Comments: 2016 American ALDES Ventilation Corporation. Reproduction or distribution, in whole or in part, of this document, in any form or by any means, without the express written consent of American ALDES Ventilation Corporation, is strictly prohibited. The information contained within this document is subject to change without prior written notice. American ALDES Ventilation Corporation 4521 19th Street Court East, Suite 104 Bradenton, FL 34203 U 941.351.3441 800.255.7749 941.351.3442 (fax) info@americanaldes.com www.aldes.us _spec_0416