IntesisBox ASCII Server - LON



Similar documents
IntesisBox KNX - LON

IntesisBox Modbus Server Fidelio IP

IntesisBox KNX Modbus RTU master

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox KNX LG Air Conditioning

Modbus Server SAMSUNG Air Conditioners

IntesisBox KNX Modbus TCP master

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

KNX Panasonic Air Conditioners

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox. Making Building Automation go further. KNX EIB Products

IntesisBox. Making Building Automation go further. Modbus Products

The Answer to the 14 Most Frequently Asked Modbus Questions

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Modbus Communications for PanelView Terminals

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TX OPEN RS232/485 module

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Modbus and ION Technology

PCS0100en Persy Control Services B.V. Netherlands

NC-12 Modbus Application

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

User Manual Revision English

1 Serial RS232 to Ethernet Adapter Installation Guide

IP Link Device Interface Communication Sheet

EDI Distributor Control Interface Wiring and Setup Instructions

Modbus and ION Technology

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Telephone- and leased line modem for industrial applications TD-36

User manual Compact Web PLC WP240 series IEC-line

CoolMaster User Manual

ZC-24DO CANopen I/O Module: 24 Digital Outputs

EZ-View Network Communications Guide

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Using HyperTerminal with Agilent General Purpose Instruments

Electronic Control Devices The European Product Catalogue 2007

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

PLC training panel (Twido version)

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Portable BACnet /IP to MS/TP Router

Electronic Control Devices The European Product Catalogue 2007

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Rack mounted telephone- and leased line modem for industrial applications

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

F2103 GPRS DTU USER MANUAL

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

IP Link Device Interface Communication Sheet

GV-Data Capture V3 Series User's Manual

CENTRONICS interface and Parallel Printer Port LPT

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

One Port Serial Server Users Manual Model ESP901, ESP901E

MS830 / MS833 Barcode Reader v1.0 9-December-2014

1 Application Description Objective Goals... 3

Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface

Communication standards and Carel solutions

MSR605. Programmer s Manual. Magnetic Stripe Card Reader/Writer (High & Low Coercivity) Revision B

MODBUS TCP to RTU/ASCII Gateway. User s Manual

connecdim Gateway G1 Ethernet TCP/IP to DALI

KSH-3000-MI. Swipe Card Reader. ( Magnetic / IC Card two in One Reader ) Revision Reason Date V

IntesisBox. Making Building Automation go further. OPC Servers

GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!

Process Control and Automation using Modbus Protocol

User Manual Revision English

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

User Manual Revision English

SYMETRIX SOLUTIONS: TECH TIP August 2015

Job Aid Pre-Installation Information S8500 Media Server

Temperature & Humidity SMS Alert Controller

SCADALink DC100 Data Concentrator

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Using IDENT M System T with Modbus/TCP

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

Toshiba Serial Driver Help Kepware Technologies

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

INTRODUCTION FEATURES OF THE ICM

RS-232/422/485, Power over Ethernet

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Industrial Bar Code Scanners

Cisco Aironet Wireless Bridges FAQ

Industrial Ethernet Data Gateways

1. SAFETY INFORMATION

Industrial Bar Code Scanners

HARTING mcon 1000 Introduction and features

Machine-to-Machine Management System. Datasheet. Models: mport, mport-s, mpower, mpower Mini, mpower Pro, mfi-cs, mfi-ds, mfi-ths, mfi-msc, mfi-msw

SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ

Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.

Transcription:

IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, LG electronics, Toshiba, Fujitsu General ) equipped with LON interface into your ASCII enabled control system (AMX, Crestron, LiteTouch ) "talking" simple ASCII messages. ASCII LON device ASCII enabled control system RS232/RS485 TP-FT/10 LON IntesisBox LON device RS232 LinkBoxLON Configuration Software Only needed for configuration Points in LON can be read and written easily from the ASCII controller device. LON interface of IntesisBox reads continuously LON devices configured by polling. All the updated readings are maintained in IntesisBox's memory for immediate interaction with the ASCII system when requested. Each LON basic data type of network variables in LON devices can be mapped into an individual internal register, accessible through ASCII messages. IntesisBox can be configured to notify to the ASCII controller whatever change of value detected for a point by means of spontaneous messages sent through the ASCII interface, configurable individually per point (no need of continuous polling by the ASCII controller). ASCII interface of IntesisBox uses serial RS232 communication (baud rate configurable). LON devices can be addressed either using Neuron-Id (physical address) or subnet/node for commissioned networks. IntesisBox has the ability to declare devices as commissioned, if needed, thus avoiding the need for a LON integration tool for commissioning. The configuration of the IntesisBox is done using LinkBoxLON, a friendly software configuration tool for Windows supplied also with the gateway.

IntesisBox capacity Element Type of LON devices Supported number of LON network variable fields Supported number of LON devices Max. (Basic version) Max. (Extended version) Notes Those supporting Free Topology channel (FT- 10) 500 4000 Maximum number of points (ASCII registers) that can be defined into IntesisBox. Each of them can contain an individual field from a LON network variable. 64 128 Maximum number of different LON devices that can be defined into IntesisBox (to read/write points into them). There are two different models of IntesisBox -ASCII Server LON with different capacity each. The two different models, basic and extended, allow to integrate respectively 500 points or 4000 points, integrating up to 64 or 128 devices.

Sample applications Integration of any LON device or system into ASCII enabled control systems. ASCII LON device ASCII enabled control system RS232/RS485 TP-FT/10 LON IntesisBox LON device Control system with ASCII master interface. BMS. SCADA. PLC. AMX Crestron LiteTouch, Typical LON devices or Systems equipped with LON interface: Air conditioners (Daikin, Mitsubishi Electric, Mitsubishi Heavy Ind, Toshiba, LG ). Chillers. Heaters. Thermostats. Fan coil controllers. Room controllers. Power meters. Energy meters. Building Control Systems (BMS). Programmable Logic Controllers (PLC)... ASCII Full supervision and control LON System supervising / controlling System under supervision / control

Typical applications Integration of Daikin VRV Air Conditioning into ASCII enabled control systems. For this application, Daikin VRV Air Conditioning system must be equipped with Daikin LON gateway (model DMS504B51), this Daikin gateway is normally commissioned by Daikin technical personnel, contact your nearest Daikin distributor for details. Indoor units DIII-NET Outdoor units LON Free Topology (FT-10) network DMS504B51 RS232 ASCII IntesisBox ASCII master device ASCII Server - LON In the technical documentation of IntesisBox supplied with the device, extended details on how to configure IntesisBox for this application is provided. Also, if you are interested in this kind of application, Intesis Software can provide you sample projects for IntesisBox, these sample projects contain specific configuration to integrate any brand of air conditioning with LonWorks connectivity, with these sample projects the configuration and commissioning of IntesisBox for this kind of application becomes easy and quick, almost plug & play.

ASCII interface of IntesisBox Type of communication supported Serial RS232 (DB9 male connector, DTE). Baud rate configurable from 1200 to 57600 bps. 8 data bits, no parity, 1 stop bit. Data Format All ASCII messages are always of fix format and associated to point's internal addresses, no matter the parameters of the LON SNVT associated. This means that there is no need to change the ASCII controller program whenever the LON configuration changes. When this happens just change the configuration of the gateway and that's all, the ASCII controller programming remains exactly the same. Message to read a point's value: >Daaaa?\r aaaa is a 4 digits number indicating the internal point's address inside IntesisBox. \r means carriage return character (HEX 0D, DEC 13). Message to write a point's value: >Daaaa=vv\r aaaa is a 4 digits number indicating the internal point's address inside IntesisBox. vv is the desired value for the point (it can be just integer or fractional, decimal point is used to separate integer and fractional parts if the number is fractional). \r means carriage return character (HEX 0D, DEC 13). Message informing about a point's value: >Daaaa=vv\r aaaa is a 4 digits number indicating the internal point's address inside IntesisBox. vv is the actual value of the point (it can be just integer or fractional, decimal point is used to separate integer and fractional parts if the number is fractional). \r means carriage return character (HEX 0D, DEC 13). This type of message is sent spontaneously by IntesisBox when receiving a change from LON, or sent in response to a previous poll of the point. Messages to indicate erroneous actions: >E01\r Is returned when trying to read a point not configured in IntesisBox. >E02\r Is returned when trying to write a point not permitted to be written. Examples: >D0001?\r Message sent to IntesisBox to read value of point 1. >D0001=23.5\r Message sent by IntesisBox to inform about the actual value of point 1 (value=23.5). >D0001=24.5\r Message sent to IntesisBox to write a value of point 1 (value=24.5). Acknowledgement IntesisBox can be configured to respond with an ACK message after executing a successful write request (ACK message is >OK\r)

LON interface of IntesisBox Specifications LON supported channel: Free Topology (FT-10) Configurable addressing options (on a per device basis): Subnet / node Neuron-Id Network variable sample rate: Below 60ms per network variable (each network variable may contain several fields, which will be mapped to different Modbus registers, if needed). Supported network variable types: All standard network variable types published by LonMark International are directly supported by configuration tool, LinkBoxLON. Support for user-defined network variable types can be added in each case, by entering their definition in LinkBoxLON. In this case, following information needs to be provided: Scale factors: a, b and c Number of fields Basic LON data type of each field Supported basic LON data types Basic LON data type Description Signed short 8-bit signed data Unsigned short 8-bit unsigned data Enum 8-bit unsigned data Signed long 16-bit signed data Unsigned long 16-bit unsigned data Signed quad 32-bit signed data Unsigned quad 32-bit unsigned data Float 32-bit IEEE float Bitfield 1 to 8-bit length unsigned bitfield

Configuration tool LinkBoxLON Visual engineering tool, easy of use, for gateway s configuration and supervision compatible with Microsoft Windows operating systems, supplied with the gateway free of charge. Multi-window tool allowing to supervise simultaneously the communication activity with both protocols (systems), real time values for all the signals allowing to modify any value (very useful for test purposes), console window showing debug and working status messages, and configuration windows to configure all the gateway s parameters and signals. Signals configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows to configure the gateway s parameters and signals while in off-line (not connected to the gateway). Connection to the gateway for download the configuration and supervision by using serial COM port of the PC (serial cable supplied with the gateway). Allows to configure all the external protocols available for IntesisBox - LON series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox - LON series. Multi-project tool allowing to have in the engineer s PC the configuration for all the sites with different IntesisBox - LON series gateways. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the gateway for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ). In LinkBoxLON, an embedded tool for import XIF files makes the configuration of the IntesisBox extremely easy and quick, almost plug & play.

Configuration parameters LON part LON interface Parameters configurable Domain id of target LON network Domain length of target LON network Subnet / node address (of IntesisBox) optional. LON sample rate LON Devices Parameters configurable per LON device defined into IntesisBox Points Parameters configurable per point Type of addressing (Neuron Id, or subnet / node for commissioned networks ) Neuron Id or subnet and node (depending on chosen addressing type) Name (optional). LON device to which the point belongs. Scale factors, offset and basic LON type of the data field inside its network variable (templates provided for all fields in Standard Network Variable Types) Network variable index on the target device SNVT number (optional, only used for network debugging) Read or write point (i.e., if the point is associated to an input or output network variable). Whether point needs to be sampled periodically or not ASCII part ASCII Interface Parameters configurable Baud rate. Data bits Parity Send OK for writes. Points Parameters configurable per point ASCII register address. Spontaneous sending. Writing to ASCII when a change of value is received from LON, or only in response of a request from ASCII.

Technical characteristics Envelope Metallic (aluminium). Size: 176mm x 94mm x 50mm. Colour Grey. RAL 7035. Power 9 to 30Vdc +/-10% 2.4W. 24Vac +/-10% 2.4VA. Power connector is a 3 poles plug-in terminal block (power + earth). Mounting options Desktop Wall DIN rail EN60715 TH35 (using external adapters also supplied with the device). ASCII port 1 x Serial RS232 (DB9 male DTE). LON Port 1 x LON (TP-FT/10) (2 poles plug-in screw terminal block). LED indicators 1 x Power. 2 x LON port activity (Tx, Rx). 2 x ASCII port activity (Tx, Rx). Console port RS232. DB9 female (DCE). Configuration Via console port. 1 Firmware Allows upgrades via console port. Functional -40 C to +70 C temperature range Functional humidity 5% to 95%, non condensation range Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). Certifications CE 1 Along with the device it is also supplied a standard DB9 male - DB9 female 1.8 m. cable for configuring and monitoring the device using a PC via serial COM port. The configuration software (free of charge), compatible with MS Windows operating systems, is also supplied with the device.

Dimensions Plug-in terminal blocks DB9 connectors LEDs 50 mm 176 mm 94 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections: Plug-in terminal blocks LEDs DB9 connectors 100 mm 135 mm 180 mm