1 CoolMaster Universal Interface Adapter for VRV, VRF Air Conditioning Systems CoolMaster 1000D CoolMaster 2000S CoolMaster 3000T CoolMaster 4000M CoolMaster 6000L CoolMaster 7000F CoolMaster 8000MH CoolMaster 9000H Revision /06/2012
2 Contents 2 Table of Contents Foreword 0 General Description 3 Overview...3 Compatibility...3 Main Features...4 Functional Description 5 Specifications 7 Port Definition Technical specifications Installation Instructions Accessories Placement and Mounting Power Supply Connecting to non VRV/VRF Units...12 Connecting and Wiring Precautions User Interface LCD Screen Explanation Led Functions...16 PC Connectivity...16 Commands List...19 Troubleshooting 20
3 1 General Description 1.1 Overview General Description 3 CoolMaster is a versatile seamless Control adapter connecting VRV / VRF Air Conditioning Systems with any RS232 or USB featured devices like Home PCs, Embedded PCs or Home Automation Controllers. Connecting such Controllers through common RS232 or USB interfaces with the CoolMaster will provide end-users with full control of all indoor units enabling them with access to HVAC's various functionalities including diagnostic. Home Automation Integrators and HVAC installers when utilizing CoolMaster will not have to worry anymore about the complexity involved in understanding and working with HVAC's internal Communication lines and gateways including their unique physical layers. Now, with the CoolMaster integrators will be provided only with a simple, well documented open ASCII protocol over RS232 or USB to seamlessly integrate with any Home Automation applications.. The product is provided with LCD that continuously indicates the status of indoor units and malfunction alerts. Basic connectivity of the product to the system can be viewed in the following schematic. 1.2 Compatibility The CoolMaster range of products is compatible with several leading VRV/VRF air conditioning systems. Each manufacturer requires different model of the CoolMaster, as described in the following table. VRV/VRF Manufacturer Daikin Sanyo Toshiba Mitsubishi Electric LG Product Name CoolMaster 1000D CoolMaster 2000S CoolMaster 3000T CoolMaster 4000M CoolMaster 6000L
4 Fujitsu Mitsubishi Heavy Hitachi General Description 4 CoolMaster 7000F CoolMaster 8000MH CoolMaster 9000H In VRV/VRF air conditioning system, regardless of the specific AC manufacturer, CoolMaster should be connected to the main air conditioning communication line. The specific details about connection to the AC system are provided in Connection and Wiring paragraph. Using the CoolMaster with non VRV/VRF systems will require additional interface adaptors for each indoor unit. VRV/VRF Manufacturer Daikin Mitsubishi Electric Product Type Interface Adaptor Split, Sky Air, Multi Mr Slim, Multi Split Toshiba RAV series KRP928, DTA112, DTA102 MAC-399IF-E, PAC-SF81MA TCB-PCNT30TLE2 LG Inverter splits PI485 Mitsubishi Heavy split units SC-ADNA-E Detailed description of connectivity can be found in Connection to non VRV/VRF Units paragraph. CoolMaster can be connected to different home automation controllers that have a controllable RS232 port (Vantage, Lite Touch, Unitronics, AMX, Crestron, Pronto, Control4, Domintel, etc), BMS, PC. 1.3 Main Features Simple RS232 Interface for Easy Integration Monitoring of the Air Conditioning System Operation Status Operation mode (Cool/Heat/Fan/Dry/Auto) Set Point Temperature Fan Speed Room Temperature Swing status (On/Off) Filter Sign Malfunction code Controlling of the Air Conditioning System Operation status (On/Off) Operation mode (Cool/Heat/Fan/Dry) Set Point Temperature Fan Speed Reset Filter Sign Swing (On/Off) Plug&Play Device Field Upgradeable Firmware Customizable for Specific Applications
5 2 Functional Description 5 Functional Description Simple RS232 Interface for Easy Integration CoolMaster is equipped with an RS232 serial port. The port can be used in two different ways: 1. Configuration and monitoring of the air conditioning system from PC using simple Windows based terminal program. (See PC connection) 2. Connected to Home Automation controller or BMS. See Commands List for brief description of supported commands. The complete documentation can be found in the Programmers Reference Manual. Air Conditioning System Monitoring CoolMaster enables Home Automation controllers or BMS to receive the air conditioning system status. The status is provided by CoolMaster as a response to "stat" command (The syntax and operands of the command can be found in the Programmers Reference Manual). CoolMaster provides the following information for each indoor unit of the AC system: Operation mode - This parameter indicates whether the required indoor unit is set for Cooling, Heating, Fan, Dry or Auto operation. The feedback returns the operation mode regardless of operation status (whether the unit is "ON" or "Off'). Within the same air conditioning system different indoor units can be in different operation modes. Set Point Temperature - This is the desired temperature defined by the user on a given indoor unit. Fan Speed - Currently set fan speed of the monitored indoor unit. There are 4 available Fan Speeds: High, Medium, Low and Automatic. Sanyo and Toshiba support all 4 Fan Speeds. Most of the Daikin indoor units support only 2 Fan Speeds: High and Low. Some of the new Daikin units (FXDQ-P and FXMQ) support 3 Fan Speeds: High (HH), Medium (H) and Low (L). Room Temperature - This is the temperature, measured in the return air inside the monitored indoor unit. This temperature measurement shows only the temperature inside the indoor unit and it doesn't always indicate correctly the temperature in the room. Swing status - This parameter indicates whether the swing operation is "on" or "off" in the monitored indoor unit. This parameter is only available for wall mounted and cassette type indoor units. Filter Sign - Each indoor unit is designed to show a reminder regarding cleaning of the filters. After certain number of operation hours the "filter" sign will be shown on the local remote controller. The time period, after which the sign appears may differ between different types of indoor units. Malfunction code - When abnormal operation of the air conditioning system occurs, there will be an indication, regarding the malfunction. The malfunction can be local. In this case the specific indoor unit will halt and malfunction code will appear on the local thermostat. When the malfunction is general, the entire air conditioning system will stop and the malfunction code will show in all local thermostats. When running "stat" command for a certain indoor unit there could be more than one malfunction code.
6 Functional Description 6 Controlling the Air Conditioning System Operation mode - CoolMaster enables Home Automation controllers or BMS to set the operation mode of each indoor unit independently. Cool, Heat, Fan, Dry and Auto operations are possible. For heat pump air conditioning system Coo" and Heat operation status cannot be set simultaneously for 2 different indoor units. For example, once at least one of the indoors has been set for Cool, all other indoor units of the system cannot be set to Heat. In Daikin air conditioning systems one of the indoor units can be set as a master for Cool or Heat operation. In this case, Cool or Heat operation of the entire air conditioning system may be carried only by sending the Cool or Heat command to this specific indoor unit. Sending the Cool or Heat command to other indoor units will have no effect. Operation status - CoolMaster enables Home Automation controllers or BMS to turn indoor units to: ON and OFF. Set Point Temperature - The Set Point Temperature of each indoor unit can be changed separately in two ways: 1. Defining the desired temperature. 2. Raising or lowering the existing set temperature by the defined delta. Fan Spped - CooMaster enables Home Automation controllers or BMS to change the fan speed of the specified indoor unit.there are 4 available fan speeds: Low, Medium, High and Auto. Sanyo and Toshiba support all 4 Fan Speeds. Most of the Daikin indoor units support only 2 Fan Speeds: High and Low. Some of the new Daikin units (FXDQ-P and FXMQ) support 3 Fan Speeds: High (HH), Medium (H) and Low (L). Reset Filter Sign - Each indoor unit is designed to show a reminder regarding cleaning of the filters. After certain number of operation hours the "filter" sign will show on the local remote controller. The time period, after which the sign appears may differ between different types of indoor units. CoolMaster enables Home Automation Controllers or BMS to send a command to the system that will reset the filter sign. Swing (On/Off) - CoolMaster enables Home Automation Controllers or BMS to change the status of the "Swing" function on each indoor unit from "On" to "Off" and vise versa. Swing function is available on wall mounted and cassette type Plug&Play Device When CoolMaster is connected to the air conditioning system, it does not require any additional configuration. After connecting the wiring, supplying the power and defining addresses of the indoor units (as explained in the installation chapter) the system is ready to work. Field Upgradeable Firmware When new features are added or some changes have been applied to the CoolMaster's functionality, the firmware of the already installed CoolMaster can be easily upgraded by the user himself. The latest firmware can always be downloaded from using the following user name and password: User : cooluser Password : coolpasswd The upgrade process is described in details in the Programmers Reference Manual. Customizable for Specific Applications CoolMaster has a number of optional functions, that can be ordered by request in order to fit specific customer's needs. Example of optional features: 1. Digital/Analog I/O. 2. Connection to the additional devices, such as CoolEx, CoolBridge etc'.
7 3 Specifications 3.1 Port Definition Specifications 7 RS232 Interface connector used in Cool Master is D-Type 9-pin DB9 female connector. Cool Master DB9 Connector front view DB9 Pin Signal Lvel ±12V ±12V GND Description TxD (Data from Cool Master) RxD (Data to Cool Master) Ground Connecting Cool Master to Home Automation Equipment According to RS232 specification cable length should not exceed 25m. RS232 Cable supplied with Cool Master is 1.5m length suitable for direct connection to PC RS232 serial port. Please note that for certain controllers it will be mandatory to use cable with cross linked the Transmit(2) and the Receive(3) pins.
8 3.2 Specifications 8 Technical specifications Item Power Supply Installation Method Surrounding C Temperature Humidity % Dimensions HxWxD mm Weight gr LCD Characters Maximal number of indoor units Maximal number of outdoor units Maximal allowable wiring length (to BMS over m RS232) RS232 Communication functions Aircon Communication Operating Conditions Specification 9 v DC Wall Mounted or DIN Rail Mounted 0 45 C Less then 85 % RH 30 x 115 x x 1 Depends on the manufacturer Depends on the manufacturer 25 9P RS232 Port (F Connection) 2 wired cable
9 4 Installation Instructions 4.1 Accessories Installation Instructions 9 Standard Accessories The following accessories are shipped in the kit. The power adaptor can be selected according to domestic AC standards (see Power Supply). Name Quantity RS232 Cable 1 Power Adaptor 1 Shape Optional Accessories The following accessories can be supplied at request depending on the desired installation location of the CoolMaster. Name Quantity DIN Rail Fixing 1 Shape 4.2 Wall Mounting Plate 1 Currently N / A Placement and Mounting The CoolMaster should be placed in a dry ventilated place. It is advised to be installed in the electricity cabinet near the BMS/Home Automation controller since the length of the RS232 connecting cable is limited (see Technical specifications). In this case it is advised to use the optional DIN Rail Fixing, as shown in the following diagrams. Another option is mounting the CoolMaster directly on wall with Wall Mounting Plate (Accessories).
10 4.3 Installation Instructions 10 Power Supply The CoolMaster device requires standard power supply of 9V DC voltage. The power transformer is included in the kit and varyies according to the country of the user. Please make sure there is a standard power plug point prepared near the CoolMaster for connection of the power transformer. The supplied types of the power transformer are described in the following table: AC Parameters Regions & Countries v 60 Hz USA, Canada, Japan, Mexico, Brazil, South America v 50 Hz United Kingdom v 50 Hz Australia, New Zealand, Asia v 50 Hz Europe, South Africa, Israel, Russia, Hong Kong, India Picture It is not recommended to use a substitutional power adaptor.
11 4.4 Installation Instructions 11 Connecting to non VRV/VRF Units CoolMaster can be used also with split units. In this case each indoor has to be provided with a communication interface (for example, D3 net interface for Daikin Units, M-Net interface for Mitsubishi Electric units, etc'). All those interfaces are plugged into the PCB of the indoor unit (the cable is provided with the interface), and their output has to be inter chained by 2 wired communication line, similarly to the wiring connection of the indoor units in a regular VRV/VRF system. CoolMaster has to be connected to this line, as shown in the following diagram. When using the CoolMaster 1000D with KRP928 or DTA102/112 adaptors in Multi/Split/Sky air range of Daikin Air Conditioning systems a change should be made also inside the CoolMaster itself. This change should be made only if there is no VRV/Centralized Controller connected to this F1 F2 communication line1. Change will be as follows: Step1 - Open the top cover of the unit Step 2 - Change the position of the dip switch (all 4 pins), as shown in the following figure Original Position (Factory supplied) New Position Please note, that when using CoolMatser with Daikin KRP and DTA D3 net interfaces, the fan speed control and room temperature monitoring is not possible.
12 4.5 Installation Instructions 12 Connecting and Wiring Connecting the CoolMaster to the system is done by 3 steps: 1. Power supply connection. 2. Connecting to the Air Conditioning Communication line. 3. Connecting to the BMS/Home Automation controller. Power Supply Connection The power plug is supplied with the CoolMaster and connected as shown in the following figure. Connecting to the Air Conditioning Communication line The CoolMaster is simply wired to the Main air conditioning Communication Line anywhere within the system. It can be wired to the terminals on one of the indoor units, directly to the terminals on the outdoor unit or to the terminals on one of the centralized controllers. A connectivity schematic is shown in the diagram below.
13 Installation Instructions 13 Make sure to connect the communication wires to exact terminal names according to the table below. Daikin Toshib Sanyo Mitsubis Fujitsu a hi Electric D3 Net TCC S3 Net M-Net VRF Main Link (TB3, transmissi Communicatio TB7) on line n Line F1 F2 Terminal names none Polarity 64 Number of Indoors 10 Number of Outdoors Shielded wiring not required Mitsubis hi Heavy Hitachi U1 U2 U1 U2 M1 M2 X1 X2 Super Link New Super Link AB none 64 none 64 none 50 none 64 none 128 none 64 Inter A, Inter B (outdoor only) none required required required required required required H Link, H Link 2 LG 12 required The connection to the CoolMaster is performed by a specified plug, as shown in the picture below. The communication wiring usually consists of two wires with mm2 cross section diameters. The wiring diameters must be the same as the wires used within the air conditioning system, according to the AC manufacturer requirements. The total wiring length within the system should not exceed AC manufacturer limitations. The following table describes the wiring specifications for different manufacturers Connecting to the BMS/Home Automation Controller The onboard RS232 connector of the CoolMaster is used for configuration, and connection to the BMS/Home Automation controller. The 1.5 m long RS232 Male/female cable is supplied with the CoolMaster. In order to operate Daikin Air Conditioning systems all the indoor units must be provided with the centralized addresses Main Communication Line is defined as the communication line between the indoor and the outdoor units. Please make sure not to connect the CoolMaster to the communication line between the indoor unit and its local remote controller. CoolMaster 6000L (LG) must be connected to the terminals of the outdoor unit (Inter A, Inter B)
14 4.6 Installation Instructions 14 Precautions Attention 1. During the system automatic operations the CoolMaster must be disconnected from the system. Examples of the automatic operations are: Test Reset Automatic charge 2. Do not change the original positions of the quadruple dip switch SW1 inside CoolMaster when using it with VRV/VRF systems.
15 5 User Interface 5.1 LCD Screen Explanation User Interface 15 Two types of screens can appear on the LCD of the CoolMaster. One screen shows the indoor units status, as shown in the figure and the explanation table below. The following table describes what is shown on the LCD Display of the CoolMaster. Segment Description Number 1 Address of the indoor unit 2 Operation Status 3 Set Point Temperature Range Example "+" - off, "-" - on "-" "18" Low Medium 4 Fan Speed High high Auto 5 Operation Mode 6 Filter Sign 7 Error Status Cool Heat Fan Dry OK - Normal Opearation U4 - example of malfunction "Cool" Ok Another screen shows the number of identified indoor units and number of groups U Number of recognized indoor units (in the example above 10) G Number of groups (in the example above 8) A3 U4 current malfunction codes in the system
16 5.2 User Interface 16 Led Functions The unit is equipped with 2 leds, as can be seen in the figure below. Leds indicate whether there is a communication with the Air Conditioning system. When there is no communication, the upper led is off. When the CoolMatser senses the communication from the Air Conditioning system, the upper led starts blinking. The lower led is currently not functioning. 5.3 PC Connectivity When the CoolMaster is connected to the air conditioning system it is suggested to check its performance by connecting it to a PC or Laptop. In order to do so the device has to be connected to the serial PC Port (RS232) or to USB port by using a transformer cable RS232 to USB and appropriate driver. After the connection, the Hyper Terminal program should be engaged, using the following sequence: Start -> Programs -> Accessories -> Communications -> Hyper Terminal
17 User Interface 17 In the opened window Connection Description an arbitrary name should be chosen. Then, in the next window named Connect to a correct port has to be chosen at the bottom box, called: Connect Using: (for example: modem, com1, com4 etc ). Next, the port setting has to be defined as following: After finishing the above definitions, if everything is correct, the version of the CoolMaster software is
18 User Interface 18 supposed to appear at the top of the window. At this point all the commands from the command list can be typed and transferred to the air conditioning system.
19 5.4 User Interface 19 Commands List on - on <UID Turn the unit on off - off <UID> Turn the unit off temp - temp <UID> <temp> Defines the unit s Set Point cool - cool <UID> Turns the system to the cooling mode heat - heat <UID> Turns the system to the heating mode fan - fan <UID> Turns the system to the Fan mode dry - dry <UID> Turns the system to the Dry mode auto - auto <UID> Turns the system to the "Auto" mode fspeed - fspeed <UID> <l m h a> Sets the unit s fan speed swing - swing <UID> Turns on/off swing operation stat - Prints the status of the all indoor units stat - stat <UID> Prints status of the specified indoor unit stat2 - Prints the status of all indoor units (including filter sign) stat3 - Prints the status of all indoor units when each parameter has a constant place in the string set - set [<echo myid> <val> allon - Turns all the indoors on alloff - Turns all the indoors off boot - Runs bootloader simul - simul <N> Simulates the specified number of indoors filt - Resets Filter Sign For detailed updated info please refer to the "Programmers reference manual" document.
20 6 Troubleshooting 20 Troubleshooting Symptom The LCD of the CoolMaster is off 1 (there is no visible display on it). After connecting the CoolMaster it does 2 not show on its LCD the correct number of indoor units. Cause a. Incorrect power supply a. Check the power adaptor and supplied voltage. Must be stable 9v DC. a. It takes several minutes to recognize the system. b. The communication line to the air conditioner is connected improperly. a. Wait for about 5 minutes b. Check the connection of the air conditioner communication line. Look if the upper led is blinking. c. If the led is off, check the wiring connection of the communication line. a. Improper serial port definitions. b. The centralized The communication addresses of the indoor does not work (the units are not defined. 3 system does not react c. The wires: transmit and to any of your sent receive of the RS232 cable commands). are not twisted. d. Carriage return has not been added to your command. The typed commands cannot be seen on the 4 a. The echo is set to "off". "hyper terminal" screen What to do a. Check that all port definitions (baud rate, flow control, parity etc ) are properly defined. b. Define the centralized addresses of all indoor units. c. Check and fix the RS232 cable connection (twisting the Tx and Rx wires). d. Add 0d at the end of the command that is sent to the CoolMaster. a. Run "echo" command and set "echo" to "On".
IntesisBox ASCII Server - LON
IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi
IntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
Modbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 [email protected]
Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 [email protected] www.ingeniumsl.com
RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.
IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A
IntesisBox Modbus Server - Mitsubishi Electric G50
IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel )
Bluetooth to Serial Adapter
Bluetooth to Serial Adapter Third Edition, Oct 2007 Version 3.0 771-BTS1009C3-001 Contents 1.0 Features....P.2 2.0 Package Content....P.2 3.0 Hard Drives Requirement.P.2 4.0 Specifications.P.3 5.0 Pin
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
KNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
How to setup a serial Bluetooth adapter Master Guide
How to setup a serial Bluetooth adapter Master Guide Nordfield.com Our serial Bluetooth adapters part UCBT232B and UCBT232EXA can be setup and paired using a Bluetooth management software called BlueSoleil
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
User Manual. Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600
User Manual Interface Adapter IA1 / Computer Interface EFOY 600 / EFOY 900 / EFOY 1200 / EFOY 1600 2 1. Introduction 1. Introduction 1.1 Introduction Thank you for choosing an EFOY product. Please read
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
Troubleshooting and Diagnostics
Troubleshooting and Diagnostics The troubleshooting and diagnostics guide provides instructions to assist in tracking down the source of many basic controller installation problems. If there is a problem
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.
Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities. More Freedom to Administrators Connectable up to 128 Indoor Unit Groups (256 indoor
TX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
QSE-CI-NWK-E Control Interface
QSE-CI-NWK-E Control Interface 369373e 1 04.05.16 The QSE-CI-NWK-E is a versatile integration access point for Lutron QS-based systems. Through either RS232 or TCP / IP over Ethernet, third-party devices
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
Vroom Hardware manual ver. 1.00 Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR
Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR ENGLISH HARDWARE MANUAL ver. 1.00 CODE 114VROOHWE00 page 1 of 22 Important Important Read these instructions
Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7
1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote
User Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com
Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1
connecdim Gateway G1 Ethernet TCP/IP to DALI
Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7
FAQs Conserve package Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7 FAQs Gateway Can I have someone install my system for me? If you are concerned
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
Setting Up the ZigBee Ethernet Gateway
Setting Up the ZigBee Ethernet Gateway MAN-01-00030-1.4 This manual describes how to install and set up ZigBee communication between a SolarEdge device (Inverters or Safety and Monitoring Interface) and
SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0
SolarEdge RS485 Expansion Kit Installation Guide Version 1.0 Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in
F2103 GPRS DTU USER MANUAL
F2103 GPRS DTU USER MANUAL Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China 1 Zip Code:361008 Contents Chapter 1 Brief Introduction of Product... 3 1.1 General... 3 1.2 Product Features...
LS-101 LAN to Serial Device server. User s Manual
LS-101 LAN to Serial Device server User s Manual Revision History Revision No Date Author Remarks 0.1 August 29, 2001 IDC Initial document INTRODUCTION Overview Almost all instruments and most industrial
ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten
ALL-USB-RS422/485 USB to Serial Converter RS422/485 User Manual ALL-USB-RS422/485 USB to RS-422/485 Plugin Adapter This mini ALL-USB-RS422/485 is a surge and static protected USB to RS-422/485 Plugin Adapter.
EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch
Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com
SVA025 Netcom2 FAQ Rev 1. Mitsubishi Netcom 2 FAQ
SVA025 Netcom2 FAQ Rev 1 Mitsubishi Netcom 2 FAQ SVA025 Netcom2 FAQ Rev 1 2 What series of Netcom did we purchase? Netcom 2 FAQ Mitsubishi has several different versions of communications available. 1.
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...
User Manual. EtherUSB
User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents
Telephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
Disclaimers. Important Notice
Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,
1. SAFETY INFORMATION
RS-232 Sound Level Meter 72-860A INSTRUCTION MANUAL www.tenma.com 1. SAFETY INFORMATION Read the following safety information carefully before attempting to operate or service the meter. Use the meter
sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
BW-500 BED WEIGHER USER MANUAL
BW-500 BED WEIGHER USER MANUAL 0 1 TABLE OF CONTENTS SPECIFICATION... 3 Equipment... 4 INSTALLING WEIGH BEAM... 5 PREPARATION FOR MEASUREMENT... 6 DP3800 Indicator... 8 POWER SUPPLY... 8 PANEL... 9 KEY
GV-Data Capture V3 Series User's Manual
GV-Data Capture V3 Series User's Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2006 GeoVision, Inc. All rights
Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI
Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling
MANUAL PC1000R [email protected]
MANUAL PC1000R [email protected] Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital
The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT
The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT Presented by: Michael Kuhlmann President Residential Control Systems Inc The Basics Thermostat Functions Measure Room
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
T-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0
T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop
Liebert IntelliSlot Web Cards
Monitoring For Business-Critical Continuity Liebert IntelliSlot Web Cards Firmware Upgrade Manual Liebert IntelliSlot Web Card, Liebert IntelliSlot Web Card-LB, Liebert IntelliSlot Web Card-LBDS, Liebert
BITMAIN. APW3-12-1600 PSU Series User Guide
BITMAIN APW3-12-1600 PSU Series User Guide Contents 1 Overview... 3 2 Features... 3 3 Specifications... 4 4 Switching On/Off Remotely... 5 5 Order Information & Wire Type... 6 5.1 Order Information...
User Manual Revision 1.002 English
Document code: MN67075_ENG Revision 1.002 Page 1 of 15 User Manual Revision 1.002 English Modbus RTU / Modbus ASCII - Converter (Order Code: HD67075-A1) for Website information: www.adfweb.com?product=hd67075
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It
its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.
Troubleshooting Poor Temperature Regulation This page lists problems that may affect the temperature performance of your LUX thermostat with suggested resolutions. For more detailed information please
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
RS232 Programming and Troubleshooting Guide for Turbo Controls
RS232 Programming and Troubleshooting Guide for Turbo Controls This Troubleshooting guide is intended for the set up and troubleshooting of the control panels onboard RS232 output. Refer to the Installation
CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual
CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CelluLine CGW-TS GSM Cellular Gateway Installation and Programming Manual CGWTS-M001A Version 1, Release 1, December 2004 NOTICE
Ordering Part Numbers:
TECHNICAL DATASHEET #TDAX021500 HYDRAULIC FAN CONTROLLER Application Platform 3 erature Sensors 4 Digital Command Interfaces 1 PWM Input and 1 Analog Input 1 Proportional or ON/OFF Current Output RS232
AXIS T81B22 DC 30W Midspan
INSTALLATION GUIDE AXIS T81B22 DC 30W Midspan ENGLISH About this Document This document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficial
Advanced Data Capture and Control Systems
Advanced Data Capture and Control Systems Tronisoft Limited Email: [email protected] Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document
Operation and Installation Manual
Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control
INSTALLATION GUIDE 1
INSTALLATION GUIDE 1 Setting information MAC-558IF-E address(mac) MAC-558IF-E serial number(id) MAC-558IF-E code(pin) Indoor unit model name Indoor unit serial number Outdoor unit model name Outdoor unit
Panasonic/Sanyo A/C Interface Modbus RTU Installation Instructions
Panasonic/Sanyo A/C Interface Modbus RTU Installation Instructions Preface Safety warnings To avoid injury, or damage to the Modbus interface, read all installation and configuration instructions in this
USB 2.0 4-Port Extender Kit
USB 2.0 4-Port Extender Kit 500072 MuxLab Inc. 2014 94-000760-A / SE-000760-A Table of Contents 1. Introduction... 2 2. Features... 2 3. Specifications... 2 4. Package Contents... 3 5. Physical Diagram...
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual Version: 1.0.1 Dec. 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Configuration (PC-PC
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.
SA-2000-II HARDWARE MANUAL Access Technologies International, Inc. 1 Table of Contents 1. Introduction 3 2. Features 3 3. Specification 4 4. Identifying Supplied Parts 4 5. Panel Description 5 6. Connection
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier. Troubleshooting Tips
Troubleshooting Tips Lifestyle SA-2 & SA-3 Amplifier Refer to the Lifestyle SA-2 & SA-3 Amplifier service manuals, part number 271720 for schematics, PCB layouts and parts lists. Preventative Repair Measures
RPLIDAR. Low Cost 360 degree 2D Laser Scanner (LIDAR) System Development Kit User Manual. 2014-2 Rev.1
RPLIDAR Low Cost 360 degree 2D Laser Scanner (LIDAR) Development Kit User Manual 2014-2 Rev.1 Team Contents: 1. OVERVIEW... 2 ITEMS IN DEVELOPMENT KIT... 2 RPLIDAR... 2 USB ADAPTER... 3 2. CONNECTION AND
1 Serial RS232 to Ethernet Adapter Installation Guide
Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).
HP 2530 8-Port Switches Quick Setup Guide
HP 2530 8-Port Switches Quick Setup Guide The switch drawings in this document are for illustration only and may not match your particular switch model. For more detailed instructions and information to
User Guide Reflow Toaster Oven Controller
User Guide Reflow Toaster Oven Controller Version 1.5-01/10/12 DROTEK Web shop: www.drotek.fr SOMMAIRE 1. Introduction... 3 2. Preparation of THE REFLOW CONTROLLER... 4 2.1. Power supply... 4 2.2. USB
F2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
Bluetooth UART/RS232 Module
Introduction BLUEMORE600 is a professional, slim, wireless module ready for integration in brand new or existing electronic products. Based on CSR chipset BC03MM it s fully compatible for Serial Port profiles.
Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY.
Manufacturer: Model Number(s): Minimum Core Module Version: Comments: HAI Document Revision Date: 4/18/2013 OMNISTAT 2 (RC-1000 and RC-2000) WIRED MODELS ONLY Firmware V. 1.03 Tested Integration Note OVERVIEW
Industrial Bar Code Scanners
DS2100N & DS2400N Industrial Bar Code Scanners Enhanced Connectivity Ease of use Configuration SW Tool ACR-Lite APPLICATIONS Small conveyor sorting Picking systems Items and parts tracking Process control
PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL
Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page
Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface
Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual
Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by
Energy Communication Unit (ECU)
Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2
Bluetooth HC-06 with serial port module Easy guide
1 Bluetooth HC-06 with serial port module Easy guide This manual consists of 3 parts: PART 1. Overview of Bluetooth HC-06 module with serial port. PART 2. Installing Bluetooth HC-06 module with Bolt 18F2550
User Manual Revision 1.002 English
Document code: MN67513_ENG Revision 1.002 Page 1 of 15 User Manual Revision 1.002 English Gateway / Adapter CAN to Ethernet (Order Code: HD67513 HD67513M) HD67513 for Website HD67513 information: www.adfweb.com?product=hd67513
UPS Network Interface. Quick InstallationGuide
UPS Network Interface Quick InstallationGuide Version 1.1 March 1999 COPYRIGHT Copyright 1999 RINGDALE UK Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed,
VOICE RECORDING SYSTEM ISDN PRI / BRI
Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE
Paragon Explorer Lite Communication Software
CU-111 APRIL 11, 2013 Paragon Explorer Lite Communication Software For Fireye Paragon Scanners using Windows XP DESCRIPTION Paragon Explorer Lite, is the basic PC based configuration tool for Paragon model
Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS
+ Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
User Manual Revision 2.101 English
Document code: MN67011_ENG Revision 2.101 Page 1 of 18 User Manual Revision 2.101 English CAN / Modbus Master - Converter (Order Code: HD67011) for Website information: www.adfweb.com?product=hd67011 HD67011
Quick start: Energy Switch EU
Technical specifications Normal operating voltage Quick start: Energy Switch EU 230Vac/50Hz Recommended max. load 3000W 600W Frequency range Wireless range Energy measurement 868.42 MHz 30~100 meters in