GRC Porticos. Lightweight entrance porticos ABBEY ARTSTONE

Similar documents
Understanding BS EN 771-3: Aggregate concrete masonry units

LAYING BLOCK AND BRICK

Asphalt Shingle Application Requirements

Chapter 2 Basis of design and materials

Hanson Building Products. precast basement solutions

Introduction. Eurocodes. Specification. Cost

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Design and Construction of Cantilevered Reinforced Concrete Structures

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Stone crusher dust as a fine aggregate in Concrete for paving blocks

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Division 4 Section Concrete Masonry Specifications

Technical Notes 3B - Brick Masonry Section Properties May 1993

Squash Court Design general points

Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete

MeltonStone Cast Stone Product Specifications

Fire and Concrete Structures

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Analysis II Façade Redesign: Architectural Precast Panels

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council. *Corrected March 2014

Materials and Colors

1.5 Concrete (Part I)

Dubai Municipality Standard DMS 1: Part 5: 2004

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Eurocode 4: Design of composite steel and concrete structures

Concrete for industrial floors

Detailing of Reinforcment in Concrete Structures

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

Commercial And Industrial Steel Buildings

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

STRENGTH OF CONCRETE INCORPORATING AGGREGATES RECYCLED FROM DEMOLITION WASTE

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

RENOVATION AND RESTORATION OF OLD BUILDINGS IN SRI LANKA

Safe & Sound Bridge Terminology

Composite Panel Firewall Systems

September Joint

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

SECTION 3 ONM & J STRUCTURAL ANALYSIS

Integrated Manhole Ladder System

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Mission 7: Saving Energy

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Connex. Mortarless Masonry Block System

ADVANCED SYSTEMS FOR RATIONAL SLAB REINFORCEMENT

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

GUIDELINES FOR REHABILITATION OF TRADITIONAL COMMERCIAL BUILDINGS DESIGN GUIDELINES

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

If stepping is required, step at 180mm as seen in this picture.

Specification for the Manufacture, Curing & Testing of Glassfibre Reinforced Concrete (GRC) Products.

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

CONTE NT DESIGN PROCESS. Appendix. 01 First Issue. 02 Revision A. 03 Revision B. 04 Co-ordination. 05 Panel Thicknesses. 06 Panel Surface Quality

ISO Types 1-6: Construction Code Descriptions

HOUSE BUILDING DIGEST

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Preparing a maintenance plan

SECTION 7: C - STRUCTURAL ENGINEERS SPECIFICATIONS

Glass and Building Regulations Impact Safety

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

Technical Manual - Section 1 Introduction to Lytag lightweight aggregate

Hanson Building Products. guide to London Brick

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

K17.12 Door closers K17. Doors

Vanishing Lid Trays Construction Methods with Tile or Masonry

CHAPTER 6 CONSTRUCTION TYPES

Special Use Commercial Properties

Think Of Us First! When It s Time to Distribute Your Plans

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

Excerpts from the Canadian National Building Code (NBC)

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

Monocouche Best Practice Guide. New-Build Housing Managing movement to avoid cracking

Rockwool Flexi Insulation Application Guide

CONTRACT PRICE ADJUSTMENT PROVISIONS (CPAP)

Structural fire design Eurocode Timber structures

Types of Structures. Mass Structures. A Layered Look

The full range of Kilsaran products are manufactured to fully meet all requirements of all current British and European Standards.

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

Spill Containment. Contents

Metropolitan Builders Association Masonry & Concrete Standard

Installation Instructions

Energy Company Obligation (ECO): Technical Monitoring Questions

Building Code Clarifications - 7. Fire Resistance

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

European Technical Assessment ETA-15/0028 of 23/02/2015

Annex of the certificate (Page 1/6) Accreditation Scope

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

Eurocode 2: Design of concrete structures

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Hardened Concrete. Lecture No. 14

FIRE RATED GLAZING System Guide

Transcription:

GRC Porticos Lightweight entrance porticos ABBEY ARTSTONE

GRC Porticos Lightweight entrance porticos Abbey Artstone's range of lightweight products designed for the construction industry is the only range of post fix lightweight GRC door surrounds available. With our range of GRC porticos you have an alternative to traditional precast or natural stone. Advantages of GRC over precast Post fix design reducing the amount of damage that can occur prior to the structure completion. Ultra thin and lightweight units that reduce labour and mechanical lifting (time and cost.) Very little demand on the structure to which it is attached to. Hidden fixing system. High resistance to water absorption. Weathering occurs almost the same as with any precast stone keeping the building constant over time. Low maintenance with no UV light deterioration We have a wide range of portico styles to suit your needs. TECHNICAL DATA COMPOSITION Abbey Artstone Architectural masonry is manufactured in accordance with GRCA Specification. We use naturally occurring aggregates, sand, Portland cement and an integral waterproofer; pigments are added were necessary. COMPRESSIVE STRENGTH Whereas traditional concrete is classified by its compressive strength, GRC is classified by reference to its characteristic flexural strength, referred to as Modulus of Rupture or MOR). GRC When tested in accordance with BS1881:Part 116: 1983 and BS1217:1997 and the United Kingdom cast Stone Association, the cast stone was tested over t hree 150mm cubes giving an average crushing strength well in excess of 50KN/mm2. MANUFACTURING TOLERANCES All Abbey Artstone Architectural masonry complies with following tolerances unless otherwise agreed in writing by The maximum permitted variation from plane is 0.03% of the maximum dimension of the item of 3mm whichever is the greater. The actual dimensions of individual regular units should conform to the stated dimensions subject to the tolerances in our full specification DENSITY The typical mean density of Abbey Artstone Limited Architectural GRC masonry is 2000kg/m3 WEATHERING Many factors influence the way GRC weathers; such as design, exposure, climate and surrounding. All pigments used are colorfast and durable and confirm to BS1014. Abbey Art Stone architectural dressings will weather in a similar manner to natural stone, when exposed to similar conditions. FIRE RESISTANCE Units manufactured in accordance GRCA standards and have been tested by Warrington Fire Global Safety. Tested in accordance with EN 13501-1:2007 GRC Reaction to Fire classification: A1 Polymer GRC - Reaction to Fire classification: A2-s1, d0 STRUCTURAL USE All GRC Units are non structural and must not be used in compression. All fixing must be used in accordance with the drawings provided failure to do so will invalidate any product warranty. HEALTH, SAFETY & WELFARE The contractor shall ensure that health, safety and welfare measures required or by virtue of the provision of any enactment or regulation or the working rules of the industry are complied with. COLOURS Portland Grey McDonald Red M08 The colours shown are indicative and colour samples should be requested for a true representation of the products colour Calder (M03), Buff Bath TECHNICAL DATA 01

PORTICO OVERVIEW OPTIONAL GRP ROOF WITH DRAINAGE HOLLOW PORTICO BEAM MECHANICALLY FIXED WITH STEELWORK FRAME HOLLOW COLUMN MECHANICALLY FIXED WITH STEELWORK FRAME 4 DIFFERENT STYLES TO SUIT 02 PORTICO OVERVIEW

PORTICO COLUMN DETAILS 440 390 360 370 2140 2630 2100 3410 max 810 max 810 max 810 max 600 440 440 440 530 COLUMN TC1 COLUMN TC2 COLUMN TC5 COLUMN TC6 max 2950mm max 3440mm max 2910mm max 4010mm PORTICO COLUMN DETAILS 03

PORTICO BEAM DETAILS OVERHANG Beam projects UNDERHAND Column projects GRC Beam Options 390 485 650 715 BEAM TYPE A BEAM TYPE B BEAM TYPE C BEAM TYPE D 390mm high 485mm high 650mm high 715mm high Optional Roof and Drainage cast from glass reinforced plastic supplied with internal drainage pipe 04 PORTICO BEAM DETAILS

ADVANTAGES OF GRC PORTICOS Our range of GRC Porticos give a great modern lightweight alternative to precast and natural stone products which are bulky, expensive, heavy and time consuming to fit. Advantages of GRC Porticos Post fix design reduces the amount of damage which can occour prior to project completion. Ultra thin and lightweight design reduces mechanical lifting and on site labour both a time and cost saving. Very little demand on the existing structure to which it is attached. High resistance to water absorbtion Weathering occurs almost the same as precast stone keeping the appearance of your building constant Low maintenance with no UV light deterioration Hidden lightweight steel support system eliminating heavy steel and concrete support for precast Integral pre finished soffit, no other trades required after construction Pre finished lead coloured GRP roof with drainange, no requirements for Lead or Asphalt to be laid Typical speed of construction for two / three men is 1 to 2 days Can be used in refurbishment situations and existing building structures Construction method is not weather dependant. GRC PORTICO ADVANTAGES 05

PORTICO SPECIFYING Column Type You must choose your column type carefully as these vary in height, although some adjustment is available to each column type a very tall portico would require a different column to a very short one. GRP Roof This is an optional component and can be supplied at extra cost, if you choose can can create your own leadroof or other detail to match your requirements grp roof with drainage fig1 beam type column to beam detail w x 50mm fig2 ffl - finished floor level fgl - finished ground level column type FGL and FFL Setting out Generallay above the FFL we recommend an upstand of 150mm minimum but this can be created to suit your requirements, Below the FFl we again recommend 150mm plus another 50mm below FGL. Opening Sizes This helps us get an overall view of how the portico will look and help to spot any potential areas for problems with the provided sizes. P fig4 S Q fig3 Column Positioning Is one of the most important aspects of specifying your portico it determins the overall size of the beam units. The way to do this is to specify the distance from the door to the column both from the side view of the portico (S) and from the front view (Q) 06 PORTICO SPECIFYING

PORTICO SPECIFYING Space above door specifying the amount of space you require above the door below the bottom of the portico beam allows us to determine the exact height you would like for your portico. This also creates a visual break between the door and the stonework. If this dimension is not specified a nominal figure of 290mm is assumed. fig5 Enquiry Site surveys are required if "as build drawings" are not available. This will require a survey by our structural engineer to asertain the building intergrity. Surveying of the ground conditions and its ability to support the portico is the responsibility of the contractor / client. R Dimensions submitted are the responsibility of the client / main contract. No responsibility will be accepted for incorrect dimensions submitted that result in the portico not fitting correctly. We reserve the right to re charge our design fee for incorrectly produced drawings. Portico Requirements / Specification Project Name Site Location Is the structure new build or existing? NEW EXISTING Is a site survey required? YES NO See fig.1 Column Type Beam Type Column to beam detail See fig.2 Distance between FGL and FFL X Distance between FFL and top of base W See fig.3 Height of structural opening T Width of structural opening P See fig.4 Distance to column base from door S Distance to column base from door Q See fig.5 Height above door R If it is possible please could you also supply any plans. sections and elevations of the structure that the portico is going to be attached to. This enables us to flag up any possible structural problems that may cause your portico design to be delayed. It will also allow us to check that the supplied dimensions are also suitable for the project. Contact Details Name Company Address Telephone Facsimile Email Please contact me via. (tick all that apply) Telephone Facsimile Email Post PORTICO SPECIFYING 07

ABBEY ARTSTONE Worth Valley Works, Pitt Street, Keighley, West Yorkshire, BD21 4PF Tel. 01535 610964 Fax. 01535 690989 Email. info@abbeyartstone.co.uk Semi Dry Wet Cast Glass Reinforced Concrete Glass Reinforced Plastic Company Registration Number : 7529533