100DHP TM CCI DRAG Control Valve For High Pressure Turbine Bypass



Similar documents
CCI 100 DPC DRAG Wellhead Production Choke Valve

VST-SE for Steam Conditioning Applications

VAD. Variable Area Desuperheaters

VAD Variable Area Desuperheaters

Improved Modern Control Station for High Pressure Bypass System in Thermal Power Plant

GS-General Service Control Valves

Why and How we Use Capacity Control

Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves

Frequently Asked Questions

Control Valve Technical Specification

Industrial Steam System Process Control Schemes

Redefining Spray Technology

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Baumann Mikroseal Control Valve

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

The Unique Accelabar Flow Meter

Chokes. Types Reasons Basics of Operations Application

Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators

Steam System Best Practices Condensate System Piping

TYPE E Main Valve Sizes 3 /8 through 12

Baumann Little Scotty Bronze Control Valve

Signature and ISX CM870 Fuel System

SD SEVERE DUTY CONTROL VALVES BULLETIN 1149 JULY 2002

Desuperheater Online Program Sizing Guidance

Flowserve - Edward Valves Development of the Flowserve Edward Equiwedge Gate Valve

Float and Thermostatic Traps Series H, C and X

Baumann Flexsleev Sanitary Control Valve

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

TABLE OF CONTENT

Control ball valves for severe services. Author: Michele Ferrante, PARCOL S.p.A., Italy

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

PRESSURE REDUCING CONTROL VALVE

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

Chapter 19 - Common Rail High Pressure Fuel Injection Systems

Guidelines for operation of minimum flow control valves

Series PVP Variable Volume Piston Pumps

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

QLM and QLD Series Three-port Control Valves

A descriptive definition of valve actuators

Basic Hydraulics and Pneumatics

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

PBX Series Quick Fit Connector Bimetallic Steam Traps

Turbocharger System Optimization

Air Eliminators and Combination Air Eliminators Strainers

Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

Kämmer Series Laboratory Valves

Pipe Cutting and Beveling Clamshells

FlowPak TM General Application Valve 1/2-4, Class 150

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

Edward Valves Edward Introduces PressurCombo Solution for High Pressure Drain Services V-Rep 93-1

BLAKEBOROUGH. Process Control Valves and Desuperheating Equipment

Select the Right Relief Valve - Part 1 Saeid Rahimi

REGULATING VALVE APPLICATIONS

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

DOUBLE SEAT BRONZE BODY HIGH CAPACITY

Nozzle Loads, Piping Stresses, and the Effect of Piping on Equipment

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Type 92S Pilot-Operated Steam Regulator

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

ECOTROL control valve

PBM has solutions for your valve application.

VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL TEL. (630) FAX.

Operational Flexibility Enhancements of Combined Cycle Power Plants. Dr. Norbert Henkel, Erich Schmid and Edwin Gobrecht

VSO MAX HP High Flow Proportional Valve

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Direct steam injection humidifiers

The Axial Flow Valve. Class 300/ SERIES

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15

H i g H E n E r gy, M u lti-stag E, D i ffu s E r type, Bar r E l Cas E, B Oi le r fe E D pu M p

WD600 STEAM TRAPS. Thermodynamic Steam Trap

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Flanged and Butt-= Weld Type

Oil and Coolant Circulating Heating System. Model - OCSM

C. starting positive displacement pumps with the discharge valve closed.

Experience In Motion. Valtek Spring Cylinder Linear Actuators

MUELLER FALLING FILM CHILLERS

Baumann Way Bronze or Stainless Steel Control Valve

Minor losses include head losses through/past hydrants, couplers, valves,

Turbine Flowmeters for Gas Applications

Section: R100 Bulletin: R Date: 07/13 Supersedes: New TRUST. Your Water Level. Steam you can depend on, 24/7. Boiler Level Indication System

Heating Water by Direct Steam Injection

CHEXTER TM FITS YOUR APPLICATION, PROFITABLY

1300 MAXTRAK SPECIFICATION

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

API Flanged Safety Relief Valves Series 526 CATALOG

Example. Fluid Power. Circuits

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Transcription:

100DHP TM CCI DRAG Control Valve For High Pressure Turbine Bypass

2 What is a HP Turbine Bypass Valve? It routes high pressure, high temperature steam around the HP Turbine, from the main steam line typically to the cold reheat line. In doing so, the HP turbine bypass valve must perform both pressure reduction as well as temperature control. Pressure reduction is accomplished with the multi-stage trim (DRAG ) within the valve body. The inlet pressure is controlled by an upstream pressure controller, signalling the valve to modulate to maintain the pressure at the required set point. Alternatively the valve can be sent a digital signal to quick open or close to control pressure. Temperature control is accomplished through the addition of water to the steam to reduce the specific enthalpy of the steam (a process called desuperheating). A separate water valve supplies the correct amount of water to the desuperheating mechanism (typically spray nozzles) within the steam conditioning valve. A downstream temperature transmitter typically operated in conjunction with a feed-forward algorithm within DCS to dictate the amount of water injected into the steam. Combined Pressure Reduction and Desuperheating Ensure Maximum Performance and Reliability The CCI DRAG 100DHP range of valves are primarily used in utility power plants for Steam Turbine Bypass to Cold Reheat but potentially can be utilized in similar applications. As reliability and performance are paramount to the operation of the plant, the selection of the DRAG 100DHP in the turbine bypass application is critical. By utilizing the energy of the steam in the high velocity region, to desuperheat, steam at required condition can be assured.

3 Requirements for a reliable and high performance Turbine Bypass System Resistance to thermal shock and fatigue The Bypass Valve will be subject to severe thermal shock {200º C (360 ºF)}. Valve body and trim must be designed to assure reliable operation Maximising Power Output and reduced Maintenance Repeatable seat tightness is required to prevent steam leakage that can otherwise be used to generate electricity ad therefore revenue. Excessive seat leakage also results in excessive maintenance and plant shutdown. Must handle severe pressure drops. The Bypass Valve will have to throttle or control pressure drops of greater than 100 bar (2500psi). The valve trim should have sufficient Pressure reducing stages and control trim exit velocity to prevent premature erosive wear, excessive damaging vibration and noise. TYPICAL CONVENTIONAL REHEAT POWER PLANT

4 Valve should have inlet/outlet connections to suit application. Valve inlet and outlet connections should be provided to suit customers piping and to maintain inlet and exit steam velocities to reasonable levels (<80m/s 250ft/s) Control of final temperature Figure 1: OP sytle nozzles provide superior primary atomization. Figure 2: Good atomization at a wide range of flow rates. The Bypass valve should have desuperheating system capable of excellent atomization to provide rapid evaporation of high quantities of spraywater required for final temperature control. Failure to do so can lead to thermal stress of valve and piping leading to cracking as well as potential flooding or Cold Re-heat. Maintenance Valve should be in-line repairable for ease of inspection and maintenance. HP BYPASS LAYOUT SHOWING INSTRUMENTATION AND WATER VALVE The DRAG, High Pressure Steam Conditioning Solution 100DHP TM by CCI is the optimum high pressure turbine bypass valve for combined cycle plants, drum boilers and process steam plants. With a compact, robust design that fits into most existing piping arrangements, it can be installed in any orientation. All components, including the flow distributor, are removable through the top of the valve, making maintenance and inspection quick and easy. The spherical body shape has been designed to avoid material

100DHP TM delivers superior pressure reduction, temperaure control, low noise and vibration, and fast response in a complete compact steam control valve. 5 concentrations and abrupt changes in wall thickness, minimizing thermal stress in the valve. Featuring an integrated spring-loaded spraywater nozzle desuperheater manifold at the outlet, the 100DHP TM minimizes the downstream desuperheating distance making it extremely compact for high pressure turbine bypass applications. Figure 3: DRAG disk stack s multi-stage pressure reduction eliminates noise, vibration and erosion. Figure 4: Spring-Loaded Nozzle Desuperheater 100DHP TM desuperheating features integral spring-loaded waterinjection nozzles that optimize water injection over a wide range of flow rates at low pressures. With a rangability limited only by the spraywater control valve, the spring-loaded water-injection nozzles vary the water flow rate as required to achieve the fine water droplet size needed for atomization. The spring-loaded water-injection nozzle design provides the smallest droplet size possible without steam assist. Low-Noise DRAG Trim Technology Designed with Multi- Stage Pressure Reduction Velocity control is recognized throughout the industry as the only reliable long-term solution for the elimination of noise, vibration, and erosion. CCI DRAG is the leading velocity control technology; the preferred low-noise valve solution for pressure reduction. 100DHP TM features a multi-path, multi-stage design that has been used successfully for over 40 years. The DRAG disk stack forces steam through a tortuous path of right angle turns to control the pressure letdown and limit the fluid velocity, thereby limiting noise, and eliminating vibration and erosion. To deliver superior performance, the DRAG disk stack configuration can be custom designed to the requirements of each application. Accurate Control CCI s long history of advanced technology valves and actuation systems for severe service has led to the development of the most reliable actuation systems available today. CCI has supplied pneumatic and hydraulic actuation systems for over 30 years and has an extensive installed base. Our pneumatic actuation systems can delivery stroke speeds of less than one second while maintaining accurate resolution and control. The selection of pneumatic or hydraulic actuation is primarily a function of valve design for the particular application as well as customer preference. A comparison of the factors influencing actuator selection is given in Table 1.

6 Highly reliable, fast, accurate pneumatic and hydraulic actuators provide superior system control. Table 1: Factors Influencing Actuator Selection Performance Attribute Speed Accuracy Hysteresis, Linearity and Deadband CCI Pneumatic Actuator 1-2 second through accessory components tree Good with overshoot, less than 1% Improve Plant Efficiency Eliminate Lost Steam During normal operation, any leakage past the turbine bypass valve means lost revenue. Steam that does not go through the turbine does not generate electricty or revenue for the plant. Money spent generating the steam is lost. Steam leaking past a valve seat could erode the seat and cause an increase in the leakage rate and maintenance downtime. The CCI 100DHP TM valve can be supplied with a Pressurized Seat Trim TM, which provides dependable, repeatable, Class V Shutoff. The special CCI seat configuration ensures that the valve seat is not exposed to high velocity steam flow, thus protecting the seat and assuring tight shutoff the first time and everytime. CCI Pneumatic Actuator with QuickTrak 1 Less than 1 second with standard pneumatic servo Excellent with no overshoot CCI Hydraulic Actuator Very fast, less than 1 second Excellent with no overshoot Less than 1-3% Less than 0.5% Less than 0.3% Dead Time on Seat Less than 300-600 ms Less than 100-200 ms Less than 100 ms Calibration/Tuning 1-4 hours Less than 10 minutes 3 2-4 hours 1. More information on CCI QuickTrak intelligent digital valve controller is available upon request and at www.ccivalve.com 2. Optional optimized CCI QuickTrak performance package including remote mounting is recommended for most applications 3. The CCI QuickTrak system allows for fast, accurate and repeatable calibration without an expert technician.

7 Modern Contoured Body DRAG Trim Technology Valve design utilizes multi-stage DRAG technology to eliminate high enegry generated noise, vibration and erosion. Removable Flow Distributor Outlet flow distributor to prevent outlet expansion noise and provide uniform flow profile for spray injection. Device is removable to accomodate line flushing shut-off. Valve body utilizes special contour design to minimize thermal stresses for high temperature applications. Fully Removable Trim No screwed or welded components to simplify installation process. Spring Loaded Spray Injection Desuperheating with high turn down spring loaded spray injection nozzles.

8 Use check list to evaluate the benefits of CCI s 100DHP design Benefits 100DHP TM Competition 1 2 Multi-stage velocity control with up to 10 stages of pressure letdown reduces noise levels to below 85 dba and eliminates noise-induced vibration which can cause fatigue failure of piping components. High performance, high thrust, fast stroking pneumatic or hydraulic actuation with many years of documented service. Accurate control and resolution to less than 1 second stroke time for pneumatics (optional). 3 4 5 6 7 8 9 10 11 Repeatable Class V Shutoff in service and improved plant efficiency through elimination of lost steam. High rangeability of steam flow achievable. Up to 100:1 with pneumatic actuation (1% resolution) and over 100:1 with hydraulics. Rangeability of desuperheating is limited by water valve selection. Spraywater manifold system allows for multiple attemperation injection points while requiring only one water supply connection. Removable flow distributor outlet cage for quick and easy maintenance. Outlet distributor utilizes Small-Drilled-Hole-Case design which reduces noise levels to below 85dBA. Compact and flexible in design easily fits into most existing piping arrangements. Can be installed in any orientation without additional support for the upper structure. Contoured valve body designed for frequent start-ups and cyclic operation. Low maintenance costs with quick change trim. No parts are welded or screwed into the valve body. Extended trim life through the reduction of flow velocity and use of properly selected materials. Optional condensate drain or pre-warming connection available if required. Special needs can be accommodated. Please consult the factory.

9 H H Table 2:Appromixate Flow to Close Dimensions (in inches) Plug Rating Std. Connections (1) A B C D E F G H 4 5 6 G F A C D B E NOTE: DIMENSIONS "C" AND "D" SHALL BE SAME FOR OPTION W/ OUTLET EXPANDER AND OPTION W/O OUTLET EXPANDER. 1900 6,8 x 12,14,16 9.25 12.50 29.00 25.00 14.38 (2) 15.62 38.25 53.0 2450 6,8 x 12,14,16 9.25 13.25 29.00 25.00 14.38 (2) 15.62 38.25 53.0 1850 8,10 x 14,16,18 10.50 14.25 30.75 25.50 15.00 (2) 16.00 41.25 55.0 2500 8,10 x 14,16,18 10.50 15.25 30.75 25.50 15.00 (2) 16.00 41.25 55.0 1850 10,12 x 16,18,20 11.75 16.25 32.00 26.00 16.00 (2) 19.88 43.75 55.0 2420 10,12 x 16,18,20 11.75 17.25 32.00 26.00 16.00 (2) 19.88 43.75 55.0 1. The 100DHP body is designed to accomodate a range of inlet and outlet connection sizes. The outlet connection can accomodate various sizes through DAM-E style expanders. 2. Dimension listed assumes buttweld or socketweld connection. Dimensions will increase for flanged connections. D E C D C E G G A A F B

10 Technical Specifications Table 3: Approximate Flow to Open Dimensions (in inches) Plug Rating Std. Connections (1) A B C D E F G H 6,8,10 x 8,10,12 (2) 8.25 11.75 31.00 25.00 11.88 (5) 15.62 39.25 53.0 1900 x 900 6,8,10 x 14 (3) 8.25 11.75 6 6 6 15.62 6 53.0 4 6,8,10 x 16,18,20 (4) 8.25 11.75 42.75 26.00 15.50 (5) 15.62 51.00 53.0 6,8,10 x 8,10,12 (2) 8.50 11.75 31.00 25.00 11.88 (5) 15.62 39.50 53.0 2450 x 900 6,8,10 x 14 (3) 8.50 11.75 6 6 6 15.62 6 53.0 5 6 1850 x 900 2500 x 900 1850 x 900 2420 x 900 6,8,10 x 16,18,20 (4) 8.50 11.75 42.75 26.00 15.50 (5) 15.62 51.25 53.0 8,10,12 x 10,12,14 (2) 10.00 13.50 31.00 25.00 12.88 (5) 16.00 41.00 55.0 8,10,12 x 16 (3) 10.00 13.50 6 6 6 16.00 6 55.0 8,10,12 x 18,20,22 (4) 10.00 13.50 46.50 26.50 16.50 (5) 16.00 56.50 55.0 8,10,12 x 10,12,14 (2) 10.00 13.50 31.00 25.00 12.88 (5) 16.00 41.00 55.0 8,10,12 x 16 (3) 10.00 13.50 6 6 6 16.00 6 55.0 8,10,12 x 18,20,22 (4) 10.00 13.50 46.50 26.50 16.50 (5) 16.00 56.50 55.0 10,12,14 x 10,12,14 (2) 10.75 14.00 31.00 25.00 12.88 (5) 19.88 41.75 55.0 10,12,14 x 16 (3) 10.75 14.00 6 6 6 19.88 6 55.0 10,12,14 x 18,20,22 (4) 10.75 14.00 46.50 26.50 16.50 (5) 19.88 57.25 55.0 10,12,14 x 10,12,14 (2) 10.75 14.00 31.00 25.00 12.88 (5) 19.88 41.75 55.0 10,12,14 x 16 (3) 10.75 14.00 6 6 6 19.88 6 55.0 10,12,14 x 18,20,22 (4) 10.75 14.00 46.50 26.50 16.50 (5) 19.88 57.25 55.0 1. The 100DHP body is designed to accomodate a range of inlet and outlet connection sizes. 2. For this size outlet, desuperheater shall be DAM or DAM-E style. 3. For this outlet, desuperheater shall be DAM-D or DAM-DE style. 5. Dimension listed assumes buttweld or socketweld connection. Dimensions will increase for flanged connections. 6. Final dimension shall be based on desuperheater design, which shall be dependent on operating conditions. Consult factory.

11 BALANCED PLUG OPTION Table 4: Capacity and Performance Trim Size 4 5 6 Max Capacity (Cv) (Flow to Open) 320 500 700 Max Capacity (Cv) (Flow to Close) 215 310 450 Valve Characterization (% Cv vs % Opening) Linear (Standard)Equal% or Modified Equal % Shuttoff Class BALANCED PLUG OPTION Class V Actuator Type Double-Acting Low Volume Pneumatic Piston Actuator 1 Model Number 320 SC/V 400 SC/V 400 SC/V Valve Position on Loss of Actuator Motive Power Open, Closed, Or In-Place as specified Opening/Closing Stroke Time 2 Second Standard < 1 second optional Inlet Design Rating 1900 or 2450 1850 or 2500 1850 or 2420 Outlet Design Rating (Flow to Close) 900 900 900 Outlet Design Rating (Flow to Close) 1900 or 2450 1850 or 2500 1850 or 2420 1. Hydraulic Actuator available upon request. PRESSURIZED SEAT OPTION Table 5: Materials PRESSURIZED SEAT OPTION Component Item No. Materials of Construction Body 1 A182-F91 or A182-F22 Bonnet 2 A182-F91 or A182-F22 Disk Stack 3 Inconel 718 Plug 4 A182-F22 with Stellite Stem 5 Inconel 718 Seat Ring 6 A182-F22 with Stellite

Contact us at: info@ccivalve.com For sales and service locations worldwide, visit us online at: www.ccivalve.com Throughout the world, customers rely on CCI companies to solve their severe service control valve problems. CCI has provided custom solutions for these and other industry applications for more than 80 years. DRAG is a registered trademark of CCI. 2008 CCI 932 12/08 5K