7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules



Similar documents
7800 SERIES RM7838B,C Relay Module

SIL 3 Capable. RM7890A,B,C/EC7890A,B 7800 SERIES Relay Modules SPECIFICATIONS APPLICATION INSTALLATION INSTRUCTIONS

How To Use A Power Supply With A Powerline 2.2 (Powerline) And Powerline 3.2 Power Supply (Powerplant)

7800 SERIES Relay Modules

Honeywell Programmer Control Cross Reference

Programmer Control Cross Reference

7800 SERIES S7800A Keyboard Display Module

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

T7079A,B Solid State Remote Temperature Controllers

SECTION VARIABLE FREQUENCY DRIVES

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

DKG 972 Gas Burner Safety Control

Y7230A CO 2 Alarm System

FIREYE MODULAR MicroM FLAME SAFEGUARD CONTROLS

RA890F Flame Safeguard Primary Control

TrueAlarm Fire Alarm Systems

AIS750 Series Alarm Annunciator

E110 FIREYE FLAME-MONITOR BURNER MANAGEMENT CONTROL FOR USE WITH THE MICROPROCESSOR-BASED EP AND EPD STYLE PROGRAMMER MODULES

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types


TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table


DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

INSTALLATION INSTRUCTIONS

Solid State Timers Type F

Water Leak Detection System

Fossil fuel heating equipment

SECTION LOW VOLTAGE LIGHTING CONTROLS

Model Description / Applications. Intermittent Pilot Gas Ignition Control

G670 Intermittent Pilot Ignition Controls

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

NC-12 Modbus Application

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

FIREDEX Conventional Fire Panels

Centro-Matic Automatic Lubrication Systems System Controls

WD-AMX Water Detection Controllers

Diesel Engine Driven Generators Page 1 of 6

Veri-Flame Single Burner Monitoring System

Electronic Control Devices The European Product Catalogue 2007

Model: DC-A2IO Advanced HVAC Controller

COMPALARM AP GENERAL MAIN FEATURES

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Paragon Explorer Lite Communication Software

Circuit Breakers. NRC Series. NRC Series

Thyristor-controlled power supplies and battery chargers

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

Eclipse Veri-Flame Single Burner Monitoring System Model 5600 Version 1

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

T7560A,B,C Digital Wall Module

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

In-Sight Hardware specifications

*.ppt 11/2/ :48 PM 1

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, (210) 16 (407) 5.5 (140) (283) 16 (407) 5.5 (140)

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

DTW Works Master Specification Version 2006

, User s Manual

Q309A,B; Q335C; Q340A; Q390A Thermocouples and Q313A,B,C,F Thermopile Generators

SECTION DETECTION AND ALARM

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Modular I/O System Analog and Digital Interface Modules

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Programming Logic controllers

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

DUCT SMOKE DETECTOR D4120

User manual Rev 1.3 Contents

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

THERMAL MANAGEMENT SOLUTIONS

Digital Keypad Use s Manual

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Back-UPS Pro 1300/1500 Installation and Operation

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Remote Monitoring and REC 501 Control Unit Product Guide

MOUNTING AND OPERATING INSTRUCTIONS

Safety Relays ESM/ESM-F

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Installation and Operation Manual

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

OZW30. Central Unit SYNERGYR

Transcription:

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules SPECIFICATION DATA FEATURES APPLICATION The Honeywell EC7895/RM7895/RM7896 is a microprocessor based integrated burner control for automatically fired gas, oil, or combination fuel single burner applications. A Relay Module, Subbase, Amplifier and Purge Card are required to complete the EC7895/RM7895/RM7896 system. Options include Keyboard Display Module (KDM), Personal Computer Interface, DATA CONTROLBUS MODULE, Remote Display Module, First-Out Expanded Annunciator and COMBUSTION SYSTEM MANAGER Software. The Relay Module is programmed to provide a level of safety, functional capability and features beyond the capacity of conventional controls. Functions provided by the Relay Module include automatic burner sequencing, flame supervision, system status indication, system or self-diagnostics and troubleshooting. The RM7896 also provides 15 seconds postpurge. Safety features: Interlock check. Closed loop logic test. Dynamic AMPLI-CHECK. Dynamic input check. Dynamic safety relay test. Dynamic self-check logic. Internal hardware status monitoring. Tamper resistant timing and logic. Access for external electrical voltage checks. Airflow switch check feature (RM7895B,D/RM7896B,D). Application flexibility. Communication interface capability. Delayed main valve (EC7895C; RM7895C,D; RM7896C,D). The EC7895/RM7895/RM7896 provides either 0.8 or 3 second Flame Failure Response Time (FFRI), depending on the amplifier selected. Dependable, long-term operation provided by microcomputer technology. First-out annunciation and system diagnostics are provided by a 2 row by 20 column Vacuum Fluorescent Display (VFD) located on the optional Keyboard Display Module. First-out expanded annunciation with 26 Light Emitting Diodes (LED) for limits and interlocks (optional). Five (LED) for sequence information, see Fig. 1. Two function Run/Test Switch (EC7895C; RM7895C,D; RM7896C,D). Interchangeable plug-in flame amplifiers. Local or remote annunciation of EC7895/RM7895 and RM7896 operation and fault information (optional). 66-2026-3

Nonvolatile memory; retains history files and sequencing status after loss of power. Report generation (optional). Remote reset (optional). Selectable recycle or lockout on loss of airflow. Selectable recycle or lockout on loss of flame (RM7895C1053 does not have the selectable option. It locks out on loss of flame.) Shutter drive output. Burner controller data (optional): Expanded annunciator status. Flame signal strength. Hold status. Lockout/alarm status. Sequence status. Sequence time. Total cycles of operation. Total hours of operation. Fault history providing for the six most recent faults: Cycles of operation at the time of the fault. Expanded annunciator data at the time of the fault. Fault message and code. Hours of operation at the time of the fault. Sequence status at the time of the fault. Sequence time at the time of the fault. Diagnostic information: Device type. Flame amplifier type. Flame failure response time. Manufacturing code. On/Off status of all digital inputs and outputs. Selected prepurge time. Software revision and version of EC7895/RM7895/RM7896 and optional Keyboard Display Module. Status of configuration jumpers. Status of Run/Test Switch (EC7895C/RM7895C,D/RM7896C,D). SPECIFICATIONS Electrical Ratings, see Table 1: Voltage and Frequency: EC7895A,C: 220 to 240 Vac (+10/-15%), 50 or 60 Hz (±10%). RM7895/RM7896: 120 Vac (+10/-15%), 50 or 60 Hz (+/- 10%). Power Dissipation: EC7895/RM7895/RM7896: 10W maximum. Maximum Total Connected Load: 2000 VA. Fusing: Total Connected Load: 20A maximum, fast-acting fuse. Environmental Ratings: Ambient Temperature: Operating: -40 F to +140 F (-40 C to +60 C). Storage: -60 F to +150 F (-40 C to +66 C). Humidity: 85% RH continuous, noncondensing. Vibration: 0.5G environment. Weight: 1 pound 13 ounces, unpacked. Dimensions: See Fig. 2. SEQUENCE STATUS LEDs RESET PUSHBUTTON FLAME SIMULATOR INPUT CAPTIVE MOUNTING SCREW DUST COVER RELAY MODULE FLAME AMPLIFIER FLAME CURRENT TEST JACKS M8995 Fig. 1. Relay Module and sequence status LEDs. 66-2026-3 2

Table 1. Terminal Ratings. Terminal Ratings Number Description RM7895/RM7896 EC7895 G Flame Sensor Ground Earth G Earth Ground a L2(N) Line Voltage Common 3 Alarm 120 Vac, 1A pilot duty. 220 to 240 Vac, 1A pilot duty. 4 Burner Motor 120 Vac, 9.8AFL, 58.8ALR (inrush). 220 to 240 Vac, 4A @ PF =0.5, 20A inrush. 5 Line Voltage Supply (L1) 120 Vac (+10%/-15%), 50 or 60 Hz (±10%) b. a The relay module must have an earth ground providing a connection between the subbase and the control panel or the equipment. The earth ground wire must be capable of conducting the current to blow the 20A fuse (or breaker) in event of an internal short circuit. The relay module needs a low impedance ground connection to the equipment frame which, in turn, needs a low impedance to earth ground. b 2000 VA maximum connected load to relay module. c See Tables 3 and 4. d 220 to 240 Vac application. Requires 220 to 240 Vac to 120 Vac, 10 VA stepdown transformer to operate the shutter. Table 2. Sequence timing for normal operation. Device Initiate Standby a Purge b Pilot Main AFSC c DMV d Flame Establishing Period EC7895A/RM7895A, RM7896A 10 sec. 4 or 10 sec. No No No RM7895B/RM7896B Yes EC7895C/RM7895C/RM7896C 4 or 10 sec. e,f. 10 sec. No Yes RM7895D/RM7896D 4 or 10 sec. 10 sec. Yes a STANDBY and RUN can be an infinite time period. b PURGE will be determined by which ST7800 Purge Card is selected. c AFSC is Air Flow Switch Check. d DMV is Delayed Main Valve. e RM7895C1020, RM7896C1036 have a fixed Pilot Flame Establishing Period of 10 seconds. f RM7895C1053 has a fixed Pilot Flame Establishing Period of 4 seconds. 220 to 240 Vac (+10%/-15%), 50 or 60 Hz (±10%). 6 Burner Control and Limits 120 Vac, 1 ma. 220 to 240 Vac, 1 ma. 7 Airflow Interlock 120 Vac, 8A run, 43A inrush. 8A @ PF= 0.5, 40A inrush, 2A @ PF = 0.2. 8 Pilot Valve/Ignition 120 Vac c. 220 to 240 Vac, 4A @ PF = 0.5, 20A inrush. 9 Main Fuel Valve 120 Vac c. 220 to 240 Vac, 4A @ PF = 0.5, 20A inrush. 10 Ignition 120 Vac c. 220 to 240 Vac, 2A @ PF = 0.2. F(11) Flame Sensor 60 to 220 Vac, current limited. 60 to 220 Vac, current limited. 12 to 20 Unused 21 Delayed Main Valve (EC7895C, 120 Vac c. 220 to 240 Vac, 4A @ PF = 0.5, 20A inrush. RM7895C, RM7896C,D 22 Shutter 120 Vac, 0.5A. 220 to 240 Vac d. 3 66-2026-3

BURNER CONTROL 5 (127) 1 POWER PILOT FLAME MAIN ALARM RESET 5 (127) 5-1/4 (133) 1 REMOVE ONLY FOR TERMINAL TEST ACCESS. M5003A 1 6-3/32 (155) M17791 Fig. 2. Mounting dimensions of EC7895; RM7895; RM7896 Relay Module, Q7800A Subbase and Q7800B Subbase, respectively, in in. (mm). 66-2026-3 4

a RM7895C,D: EC7895C, RM7896C,D Jumper terminals 8-9. a Pilot Duty relates to solenoid-type valves. Table 3. Combinations for terminals 8, 9, 10 and 21. Combination No. Pilot Fuel 8 Main 9 Ignition 10 Delayed Main Valve 21 1 C F No Load No Load 2 B F No Load No Load 3 F a No Load No Load No Load 4 F F A No Load 5 F a No Load A F 6 D F A No Load 7 D a No Load A D 8 D D A No Load 9 D a No Load A D Table 4. Composition of each combination. A. B. C. D. F. 4.5A ignition 50 VA Pilot Duty a plus 4.5A Ignition. 180 VA Ignition plus Motor valves with: 660 VA inrush, 360 VA open, 250 VA hold. 2A Pilot Duty. a 65 VA Pilot Duty a plus Motor valves with: 3850 VA inrush, 700 VA open, 250 VA hold. Approval Bodies: RM7895, RM7896 only: Underwriters Laboratories Inc. listed, File No. MP268, Guide No. MCCZ. Canadian Standards Association certified, LR9S329-3. Factory Mutual Approved: J.I.1V9A0.AF. IRI acceptable. Federal Communications Commission: Part 15, Class B Emissions. EC7895A,C: Factory Mutual Report J.I.OYOA9.AF. Mounting: Q7800A for panel mount or Q7800B for wall or burner mount. Required Components: Plug-in Flame Signal Amplifier, see Table 2. Plug-in Purge Timer Cards: selectable ST7800A: two seconds to 30 minutes. Wiring Subbase Q7800A or Q7800B. Accessories: Keyboard Display Modules (KDM): S7800A1001 English language. S7800A1035 French language. S7800A1043 German language. S7800A1050 Italian language. S7800A1068 Spanish language. S7800A1118 Katakana (Japanese) language. S7800A1126 Portuguese language. Communications: Q7700A1014 Network Interface Unit, 120 Vac, 50/60 Hz applications, external modem required. QS7800A1001 ControlBus Module, standard. QS7800B1000 ControlBus Module, multidrop. QS7850A1006 ControlBus Module, General Purpose Interface. ZM7850A1001 Combustion System Manager software. S7810A1009 Data ControlBus Module (if no KDM is used). S7810B1007 Data ControlBus Module, Multi-Drop Switch Module. S7810M ModBus Module. Miscellaneous: A7800A1002 7800 SERIES Tester. S7820A1007 Remote Reset Module. S7830A1005 Expanded Annunciator, 120 Vac, 50/60 Hz. 203541 Data ControlBus Connector, 5-wire. 203765 Remote Display Mounting Bracket. 221729 Dust Cover, Relay Module. 204718A Keyboard Display Module Cover, NEMA 4, clear. 204718B Keyboard Display Module Cover, NEMA 1, clear. 204718C Keyboard Display Module Cover, NEMA 4, clear with reset button. 205321B Flush Display mounting kit. 221818A Extension Cable, display, 5 ft (1524 mm). 221818C Extension Cable, display, 10 ft (3048 mm). 123514A Rectification Flame Simulator. 203659 Ultraviolet Flame Simulator. 203968A Remote Display Power Supply, 13 Vdc, plug-in. 5 66-2026-3

Plug-in Flame Signal Amplifiers Type Color Self-Checking Model Table 5. Flame Detection System. Rectification Green No R7847A 0.8 or 3 sec. Dynamic AMPLI-CHECK R7847B c 0.8 or 3 sec. Applicable Flame Detectors Flame Failure Response Time Fuel Type Models a Order flame rod separately; see holder instructions. b The C7012A,C, C7027, C7035 and C7044 Flame Detectors should be used only on burners that cycle on-off at least once every twenty-four hours. Appliances with burners that remain on continuously for twenty-four hours or longer should use the C7012E,F Flame Detector with the R7847C Amplifier; The C7061A Flame Detector with the R7861 Amplifier, or the C7076A,D Flame Detector with the R7886A Amplifier as the ultraviolet flame detection system. c Circuitry tests the flame signal amplifier 12 times a minute during burner operation and shuts down the boiler if the amplifier fails. d Use only Honeywell Photocell, part number 38316. e Circuitry tests all electronic components in the flame detection system (amplifier and detector) at least 12 times a minute during burner operation and shuts down the burner if the detection system fails. f 220 to 240 Vac application. Requires 220-240 Vac to 120 Vac, 10 VA stepdown transformer to operate the shutter. Gas Oil 3 sec. Gas, oil, coal. Gas Rectifying Flame Rod Holders a Rectifying Photocell Ultraviolet (Purple Peeper ) Rectifying Flame Rod Holders a C7004, C7007, C7011. Complete Assemblies: C7008, C7009, Q179. C7003, C7010, C7013, C7014. C7012A,C b. C7004, C7007, C7011. Complete Assemblies: C7008, C7009, Q179. Oil Rectifying C7003, C7010, C7013, Photocell d C7014. 3 sec. Gas, oil, Ultraviolet C7012A,C b. coal. (Purple Dynamic Self-Check R7847C e,f Peeper ) C7012E,F. Infrared Red No R7848A Infrared C7015. Dynamic AMPLI-CHECK (Lead R7848B c Sulfide) Ultraviolet Purple No R7849A 0.8 or 3 Dynamic AMPLI-CHECK R7849B c sec. Gas, oil. Ultraviolet (Minipeeper) Dynamic Self-Check R7861A e,f Ultraviolet C7061. Blue Dynamic Self-Check R7886A e,f 3 sec. Gas, oil, coal. Optical White Dynamic AMPLI-CHECK R7851B 0.8/1 or 2/3 sec. Ultraviolet (Adjustable Sensitivity). Optical (UV, IR, Visible Light). C7027, C7035, C7044 b. C7076. C7927, C7935, C7915, C7962. 66-2026-3 6

7 66-2026-3

Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 customer.honeywell.com U.S. Registered Trademark 2005 Honeywell International Inc. 66-2026-3 M.S. Rev. 11-05