Basic Nameplate Information



Similar documents
MAC-120HE-01 Air-Cooled Chiller

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Centrifugal Fans and Pumps are sized to meet the maximum

Pump Formulas Imperial and SI Units

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

HVAC FORMULAS. TON OF REFRIGERATION - The amount of heat required to melt a ton (2000 lbs.) of ice at 32 F. 288,000 BTU/24 hr. 12,000 BTU/hr.

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

Gas Line Sizing. Z Maximum gas demand shall be determined by adding all of the equipment Btu ratings from appliances connected on the system.

Electric Motor Brake Horsepower Calculations

General Information. ME-business can be accessed through: www. marathonelectric.com.

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

How To Make A High Efficiency Thermostat

Section 10. Application Manual for NEMA Motors. Special Applications

We will discuss common industrial applications with guides for the proper use of electric motors on these.

Performance Rating of Room Fan- Coils

GCS16 GCS20 WARNING CAUTION

Model 1210C Battery Powered Pump Shown. Description

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

G234X-55 Conventional Gas Boiler

Frequently Asked Questions Generators

Cooling Capacity CFM in. w.c. (125 Pa)

300 Series PA Pump and Cooler Assemblies

THE PROPANE TECHNICAL POCKET GUIDE

What Do All Those Things on an AC Motor Nameplate Mean?

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

TERMINAL MARKINGS AND CONNECTIONS PART WINDING START

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Cooling Capacity CFM in. w.c. (125 Pa)

UNDERSTANDING REFRIGERANT TABLES

F9MXE. Product Specifications

Fuel and Energy Conversion and Equivalence Chart

Preferred SI (Metric) Units

Goulds Water Technology

GCS

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

Characteristics of Evaporators

Cooling Capacity CFM in. w.c. (125 Pa)

Glossary of Heating, Ventilation and Air Conditioning Terms

TECHNICAL MANUAL GDS8 & GHS8

Xcel Business Customers: Program and Rebate Summary

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Bell & Gossett Parts List DHP-650-PL. Replacement Parts for Hoffman Series VBF & Hoffman Series HBF. Boiler Feed Units

Home Energy Evaluation Report

INTERIM UNITS OF MEASURE As suggested by Federal Standard 376B January 27, hectare (ha) Hundred for traffic buttons.

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Low Profile Unit Cooler

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Creating Efficient HVAC Systems

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

2 MODEL AND APPLICATION INFORMATION

ARMSTRONG AIR HEAT PUMPS

GE Industrial Systems. AC Motor Selection and Application Guide

This slide is hidden. It will not show up during presentation.

Engineering Excellence HVAC Retrofit Keyword Dictionary

Commercial Gas Water Heaters

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

G9MXE. Product Specifications

AHRI Standard 325 (Formerly ARI Standard 325) 1998 Standard for Ground Water-Source Heat Pumps

Heating, Ventilation & Air Conditioning Equipment

MODEL DJ-3 DRAFT INDUCER SPECIFICATIONS

COMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC)

Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After

Introduction. Basic Electricity. Frequency. Direct Current. Alternating Current DIRECT CURRENT DC

Commercial Gas Furnace Upflow

Certified Residential Energy Auditor (REA) Study Guide

Motor Specifications. Nameplate

Evaporative Cooling System for Aquacultural Production 1

Specifying a Variable Frequency Drive s

The Different Types of AC Power Connectors in North America

Energy Efficiency. Energy Efficient Home Cooling:

The Ultimate Truck Stock Motor

DATA CENTER SOLUTIONS. For More Information: (866) Technical Data

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

TECHNICAL INFORMATION Bulletin

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

Inverter technology. bulletin

FAIRBANKS NIJHUIS FIRE PUMPS.

HVAC Efficiency Definitions

HVAC Basic Science - System Capacity

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

White paper on the comparative energy efficiency of zoned electric heaters Convectair, Inc. / Convectair-NMT Inc. September 2004

ENERGY CONSERVATION PRESENTATION BY : PCG CORPORATION

Installation Manual CLIFC Fan & Coil Variable Speed

Heavy Duty Industrial Air Compressors

AABC Specifications for Testing and Balancing HVAC Systems

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Bulletin Approval of electrical equipment. Bulletin Approval of electrical equipment

Appendix C. Minimum Equipment Efficiency Standards

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

Energy Savings With Adjustable Frequency Drives. for Centrifugal Fans

IV. Rear Mount System

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

SUNON SPECIFICATION FOR APPROVAL

Transcription:

Basic Nameplate Information General Information: Most equipment nameplates will have some common items of information. Many of these are self explanatory, and include: Manufacturer Manufacturerʼs address Model number Serial number Certification mark(s) This general information can be useful in finding out more details about particular through the manufacturerʼs published information. Various certification marks are shown below. The model number and serial number may provide specific information. The manufacturerʼs literature may help decipher the coding used for particular equipment. As an example, a generator serial number might be P4W00236D05045, where: P4W - Product designation 00236 Sequential number assigned on manufacturing date D Manufacturing location letter code 05 Year manufactured 045 Day of the year manufactured (045 = Feb 14) A light fixture model number might be SH 400MP A16 240 HEB WGA16, where: SH - Fixture series 400MP Lamp type A16 Reflector style 240 Voltage HEB HID electronic ballast WGA16 Wire guard for A16 reflector Basic electrical information, common to lighting fixtures, motors, electrical appliances and heating and cooling equipment, includes the following: Voltage (V) Amperage (A, Amps) Frequency (Hz or cycles per second) Power in Watts (W) or Horsepower (HP)

Nameplate Data for Different Equipment Types Motors: The National Electric Code requires that motor nameplates include the following information in addition to the manufacturerʼs name and address: Rated voltage(s) Rated full-load amperage at each voltage level (FLA) Frequency typically 60 or 50hz Phase Single or three phase Speed - Rated full-load speed (in RPM) Insulation Class and rated ambient temperature Insulation class may be B, F and H, and the rated ambient temperature is the maximum allowable ambient temperature during operation. Rated Horsepower Time Rating Usually continuous duty, but some motors may be rated for as low as 5 minutes of continuous operation. Locked-rotor code letter Other motor data may include: Frame size NEMA design letter indicates the relationship between speed and torque Full-load efficiency Power factor

Pumps: Items specific to pumps may include: Rated Flow (Q) - gallons or liters per minute (GPM or lpm) Head pressure at rated flow - feet of water, pounds per square inch (psi), pascals (pa) Power Horsepower (HP) Rated rotational speed revolutions per minute (RPM) Maximum pressure feet of water, psi Maximum fluid temperature degrees Fahrenheit or Celsius ( o F or o C) Other information that may appear on the nameplate, or may be encoded in the Type or Model number, may include: Type of pump centrifugal Materials used in components Seals, impellers, shafts, etc. Number of stages Number of impellers

Fans: Air flow CFM Static pressure inches of water Fan diameter inches, for centrifugal fans Heating Equipment: Fuel Type Natural gas, LPG (propane), #2 oil, etc. Input Heat input in Btu/hr Minimum input minimum heat input in Btu/hr Thermal Output Useful heat, in Btu/hr Efficiency In percent (can be estimated by dividing thermal output by the input) Gas Supply Pressure

Refrigeration Condenser Nameplate Lighting Fixtures: Lighting ballasts generally have nameplates with a variety of information, including: Operating temperatures Input voltage(s) V Output voltage(s) V Input frequency (usually 50 or 60) Hz Sound rating Ballast type and class The ballast nameplate may also indicate compatible bulbs and include wiring diagrams, start temperatures and other characteristics.

Common Nameplate Information, Abbreviations, and Units Description Abbreviation Common Units and notes Rated Flow Q Gallons per minute (GPM) Liters per minute (lpm) Air Flow Cubic feet per minute (CFM) Pressure P Inches of water (in.) Feet of water (feet, ft.) Pounds per square inch (psi) Pascals (pa) Power Horsepower (HP) Watts (W) Rated Rotational Speed Revolutions per minute (RPM) Head pressure at rated See Pressure H, TDH flow Maximum pressure Pmax See Pressure Maximum fluid Degrees Fahrenheit ( o F) Tmax temperature Degrees Celsius ( o C) Fuel Type Minimum input Thermal Output Efficiency Percent (%) Natural gas Propane (LPG) #2 Oil British Thermal Units per hour (Btu/hr, BTUh) British Thermal Units per hour (Btu/hr, BTUh) inches of water (in., in-wc) Gas Supply Pressure Pounds per square inch (psi) Pascals (pa) Rated voltage(s) V Volts (V) Rated full-load amperage A Amperes (A) listed for each voltage Frequency Phase! Single or three Speed Revolutions per minute (RPM, R.P.M.) Full Load Efficiency Percent (%) Power Factor PF

Abbreviations and Certification Marks Common Abbreviations A Amperes or amperage (electrical current) AC (A.C.) Alternating current AFUE Annual Fuel Utilization Efficiency Amp. Amperes (electrical current) BTU British thermal units (heat energy) BTU/hr BTUs per hour (rate of heat delivery) CFM Cubic feet per minute EER Energy Efficiency Ratio FLA Full load amperes (electrical current) o F Degrees Fahrenheit o C Degrees Celsius DC (D.C.) Direct current Feet On pumps, feet of water (pressure) Gal. Gallons (liquid volume) GPM Gallons per minute (flow) HP (H.P.) Horsepower (motor power) HSPF Heating Season Performance Factor Hz Hertz (alternating current frequency in cycles per minute, typically 60 or 50) In. W.C. (also W.C. ) Inches of water column (pressure) LRA Locked rotor amperes (electrical current) PSI Pounds per square inch (pressure) PSIG (P.S.I.G.) Gauge pressure in pounds per square inch PH or Φ Phase (typically single or three) QTY - Quantity RLA Running load amperes (electrical current) RPM (R.P.M.) Revolutions per minute (rotational speed) SEER Seasonal Energy Efficiency Ratio S.F. Service Factor W Watts (power)

Common Certification Marks Canadian Standards Association (CSA) Conformité Européene (European Conformity) CSA Gas Appliance Certification EPA Energy Star Factory Mutual (FM) Federal Communications Commission (FCC) Intertek Equipment Testing Laboratory (ETL) Standards Council of Canada Labtest Certification Underwriters Laboratory (UL) Underwriters Laboratory Recognized Component Mark!