Information. From the LowVision Specialists. Guidelines for the fitting of telescopic systems



Similar documents
The light. Light (normally spreads out straight and into all directions. Refraction of light

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

9/16 Optics 1 /11 GEOMETRIC OPTICS

Magnification Devices

Care and Use of the Compound Microscope

Thin Lenses Drawing Ray Diagrams

EXPERIMENT 6 OPTICS: FOCAL LENGTH OF A LENS

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

Progressive Lens Troubleshooting

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Chapter 17: Light and Image Formation

Lesson 26: Reflection & Mirror Diagrams

Basic Optics System OS-8515C

Experiment 3 Lenses and Images

Clinical Techniques for Prescribing BiopticTelescope Devices

1. You stand two feet away from a plane mirror. How far is it from you to your image? a. 2.0 ft c. 4.0 ft b. 3.0 ft d. 5.0 ft

Convex Mirrors. Ray Diagram for Convex Mirror

Power Diameter Base curve SOFT TORIC CONTACT LENS PROF.DR.SAMIHA ABOULMAGD 1

EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination

RAY OPTICS II 7.1 INTRODUCTION

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Understanding astigmatism Spring 2003

Lesson 29: Lenses. Double Concave. Double Convex. Planoconcave. Planoconvex. Convex meniscus. Concave meniscus

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages Equipment Needed

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.

Alignement of a ring cavity laser

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

THE COMPOUND MICROSCOPE

Chapter 27 Optical Instruments The Human Eye and the Camera 27.2 Lenses in Combination and Corrective Optics 27.3 The Magnifying Glass

4. CAMERA ADJUSTMENTS

Solution Derivations for Capa #14

2WIN Binocular Mobile Refractometer and Vision Analyzer

Chapter 22: Mirrors and Lenses

Chapter 23. The Reflection of Light: Mirrors

First let us consider microscopes. Human eyes are sensitive to radiation having wavelengths between

Contents. Introduction 2. Features and Benefits 3. Freeform Design Range 10. Custom 14/16/ Custom U 15. Custom V 17.

Light and Sound. Pupil Booklet

Light and its effects

Vestibular Assessment

See a world more with Keeler Loupes

MT-30 & MT-90 Series. Advanced Academic Microscopes/ Advanced Academic Polarizing Microscope INSTRUCTION MANUAL

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

1 of 9 2/9/2010 3:38 PM

Introduction to Lensometry Gregory L. Stephens, O.D., Ph.D. College of Optometry, University of Houston 2010

Handheld USB Digital Endoscope/Microscope

OPTICAL IMAGES DUE TO LENSES AND MIRRORS *

Geometrical Optics - Grade 11

Pole Lathe and Shave Horse Design

Binocular Vision and The Perception of Depth

DEPENDABLE ACCURACY. RIGHT TO THE POINT.

Physics 1230: Light and Color

7.2. Focusing devices: Unit 7.2. context. Lenses and curved mirrors. Lenses. The language of optics

progressive lenses. ADJUSTING TO PROGRESSIVE LENSES Progressive Bifocal Lenses Explained By Dr. Dhavid Cooper

PATIENT INFORMATION BOOKLET

SafetyScan Lens. User Manual

Endoscope Optics. Chapter Introduction

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Protocol for Microscope Calibration

Optics. Kepler's telescope and Galileo's telescope. f 1. f 2. LD Physics Leaflets P Geometrical optics Optical instruments

CYBEX GmbH Riedinger Str Bayreuth Germany.

Microscope Lab Introduction to the Microscope Lab Activity

Chapter 36 - Lenses. A PowerPoint Presentation by Paul E. Tippens, Professor of Physics Southern Polytechnic State University

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

SCHOOL ACCREDITATION DOCUMENT

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

LEVEL I SKATING TECHNICAL. September 2007 Page 1

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Exercise 1: Knee to Chest. Exercise 2: Pelvic Tilt. Exercise 3: Hip Rolling. Starting Position: Lie on your back on a table or firm surface.

Fundamental Shift in Use of Vision. Fundamental Shift in Use of Vision. Visual Fatigue Syndrome. Widespread Computer Use. Work, Home, School:

GRID AND PRISM SPECTROMETERS

Proper Workstation Setup

Vision Correction in Camera Viewfinders

Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03

Phoroptor VRx Digital Refraction System

Making a reflector telescope

Information for parents and guardians

FirstView 3 Reflector Telescope Owner s Manual

Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2. Before starting, make sure firearm is UNLOADED!!

Product Range Overview

Professional Fitting and Information Guide

VISM CQB Scope Series

SP AF 300mm F/2.8 LD [IF] for Canon (Model 360EE)

PRACTITIONER S FITTING GUIDE. Keratoconus Irregular Cornea Post Graft

Flat-Field IR Mega-Pixel Lens

Physics 116. Nov 4, Session 22 Review: ray optics. R. J. Wilkes

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Chapter 8: Perceiving Depth and Size

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Reflection and Refraction

SPECTANGLE PRO USER MANUAL

ENGINEERING METROLOGY

National Optical & Scientific Instrument Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

GLobAL Dental Microscopes. Dentists First Choice

A Guide to Work with Computers

RX Webshop User Guide

Lenses and Telescopes

Do you sit at a desk all day? Does your 9 to 5 leave no time for structured exercise..?

The Vortex Spitfire 1x Prism Scope

Transcription:

Information From the LowVision Specialists Guidelines for the fitting of telescopic systems

About a successful fitting Eye care professionals dispensing telescopic spectacles must ensure they have successfully fitted and tested them with the visually impaired person beforehand. The fitting of telescopic spectacles takes place over several steps: Anamnesis Refraction and visual acuity testing Choice of the telescopic system Optical and anatomical fitting Dispensing and familiarisation A detailed anamnesis significantly eases the fitting of any magnifying visual aid and prevents wrong fittings or fittings which ignore the requirements of the patient. It also is the basis for the choice of the magnifying visual aid. Considerable instinct and sensitivity is demanded from the eye care professional. This brochure mainly describes the optical and anatomical fitting of telescopic spectacles. 2

The differences between Galilei and Kepler systems The systems primarily differ in terms of their design. While Galilei systems consist of a converging and a diverging lens and create an upright image, Kepler systems are made from two positive lenses and use prisms to reverse the inverted image and to shorten the system. The specific advantages of the different systems are described on the following page. 3

937185 1,8 x Field of view 23 ; 13 g The differences between Galilei and Kepler systems Advantages of Galilei systems Light and unobtrusive 937215 2,1 x Field of view 20 ; 15 g Good contrast vision Large field of view Easy to use Exact centration 937255 2,5 x Field of view 18 ; 20 g 937275 2,7 x Field of view 13 ; 30 g 931935 Kepler 3 x 9 Magnification 3 x, field of view 12,5, objective Ø 9 mm 931945 Kepler 4 x 10 Magnification 4 x, field of view 10,0, objective Ø 10 mm 931955 Kepler 4 x 12 Magnification 4 x, field of view 12,5, objective Ø 12 mm 932165 Kepler 6 x 16 Magnification 6 x, field of view 10, objective Ø 16 mm, black metal housing Advantages of Kepler systems Better image quality Higher telescopic magnifications possible Longer working distance Well-defined and evenly illuminated field of view Can be used for different distances by focusing 4

The right choice of the system Amongst others the following criteria have to be considered when choosing the system for a user: Kind of visual impairment Residual visual acuity Remaining field of view Transparency of the ocular media Binocular or monocular vision Ability of the visually impaired person to use the visual aid Following the determination of the data listed below, which are conditions for the successful fitting of a visual aid, it now is up to the fitting eye care professional to choose the optimum aid for the visually impaired person and to test this aid with them. However, the final decision which specific visual aid is suitable can only be made by the visually impaired person themselves on basis of a thorough consultation and intensive testing. Conditions for the successful fitting of a visual aid Determination of the following data: Distance visual acuity Visual acuity requirement Magnification requirement Reading ability Light requirement 5

The calculations at specific viewing distances Galilei and Kepler systems in general are initially designed for infinity. For use at finite distances the systems have to be adjusted accordingly. Most Kepler systems can be focused on the viewing distance by turning the objective lens in a different position. As Galilei systems apart from a few exceptions are fixed focus systems an accommodation compensation lens is normally used on the ocular side or an appropriate front cap lens. Option 1 Calculation of the accommodation compensation Accommodation compensation A = System a E L, 2 = System magnification 2 Viewing distance This accommodation compensation is then offset against the distance correction. 6

Option 2 Adjustment of the viewing distance with a front cap lens It is possible to combine a basic front cap lens for the intermediate viewing distance with a flip-up front cap lens as a magnifying lens for an additional reading distance. This combined front cap lens has two viewing distances. The first lens adjusts the system to a medium viewing distance (2.0 m, 1.52 m or 1.0 m). This for example corresponds to the TV distance. With an easy flip mechanism the second lens can be added in front of the system. The system is now set up for near vision. Front cap lens Basic (D) Intermediate viewing distance (m) 0,50 D 2,00 m 0,66 D 1,52 m 1,00 D 1,00 m Front cap lens Basic 938055 + 0,50 938065 + 0,66 938105 +1,00 Viewing distance = 1 D 7

The calculations of the total magnification In order to use the system for near vision the object distance is shortened. With Kepler systems this is done by turning the objective lens in a different position or also the way done with Galilei systems by the addition of a magnifying front lens. These ways telescopic spectacles become telescopic magnifying spectacles. The total magnification with a magnifying front lens is calculated as follows: Example calculation: Magnification of the system: 2.10 x Magnification of the front cap lens: 1.25 x L, = 2.1 x 1.25 = 2.625 total Total magnification L, L, L, total = system x front cap lens = system magnification x front cap lens magnification Example calculation: 5 D front cap lens L, front cap lens = 5 D = 1.25 4 D Magnification of the front cap lens L, front cap lens = D 4 D Consequently the viewing distance with telescopic magnifying spectacles is longer by the factor of the telescopic system magnification in comparison with microscopic magnifying spectacles of the same magnification. 8

N B F U D R V E H B N B F R V E The optical fitting of the telescopic spectacles 1. Eye test at the viewing distance First of all it is advisable to position the visually impaired person at the same distance from the eye test chart at which they will watch TV with the system (or at the regular viewing distance with the system). On the eye test chart they will be provided those optotypes which they are barely but still able to recognise at this distance with the earlier determined distance correction but without a magnifying visual aid. 2. Fitting with the trial frame Depending on the achieved visual acuity, magnification requirement and field of view a telescopic system will now be added (monocular on the better eye). With Galilei systems (unless already adjusted to the shorter distance) the accommodation compensation has to be added on the ocular side in the trial frame. A Kepler system has to be focused on the viewing distance. Important are an exact centration and the Corneal Vertex Distance (CVD) to be as short as possible. 30 m 24 m 19 m 15 m 12 m 9,5 m 7,5 m 6 m 4 m 3,6 m 3 m 2,4 m 1,8 m F D B F D B E V N P R U K D V E B H R K U P F B V H E N U F P K D E N V H R P K F D B V R H N U K B D F E H N U R F V U R D K N P R D V E R K U B V H U F P E N V P K F V R H K B D H N U V U R With this magnifying system an increase in visual acuity by about the factor of the system magnification can be expected. At this point a check of the earlier determined distance correction makes sense. As the visually impaired person now can recognise more visual acuity levels it is possible for them to give more precise responses. The additional trial lenses are added behind the system on the ocular side. CVD as short as possible! 9

The optical fitting of the telescopic spectacles (continued) 3. Eye test at the reading distance With an added magnifying front lens it is possible to test the near vision reading right away. The power of the front lens depends on the determined magnification requirement for near vision and the total magnification formula described before. With focusable systems the close distance can be set by turning the objective lens in the appropriate position. 4. Testing the second eye Insofar as the conditions are met, the same testing procedure is applied to the second eye. The examination of the binocular visual improvement for the distance vision is carried out with two telescope systems positioned in parallel under consideration of the same rules as those applying to the monocular test. Please note : The magnification (for both near and distance vision) generally has to be chosen as low as possible because the viewing distance, the field of view and the depth of focus decrease rapidly with increasing magnification. 10

The mechanical fitting of the telescopic spectacles The mechanical fitting is at least as important as the choice and the optical fitting of the telescopic system. It is carried out in three steps: 1. Choice of a suitable frame 2. Anatomic adjustment of the frame 3. Determination of the visual points Korrekte Anpa Choice of a suitable frame When choosing the frame it is of utmost importance to ensure a good fit especially in the nasal area. Medical requirements for telescope frames: The frame has to be adjustable to the anatomic conditions of the patient (fit, pantoscopic angle, temple length, visual points, etc.) in a way that ensures a comfortable firm hold and that also the optical correction requirements can be fulfilled in combination with the mounted optics. The material of the frame must not emit any toxic substances and has to be skin-friendly. The frame has to be designed in such a way that its shape remains unchanged after the adjustment. 11

The mechanical fitting of the telescopic spectacles (continued) Choice of a suitable frame (continued) The frame must not impose any risk of injury and all of its edges and/or surfaces must be rounded off. Technical requirements for telescope frames: 935806 Titanium telescope frame Titanium grey colour, matt, size 50-18-145 Compliance with current standards, laws and regulations Secure hold of the lenses Adjustable temple length The frame including all bridges, joints, etc. has to be designed in such a way that any strain during the adjustment and the correct use does not lead to damages of the spectacles 935576 Titanium telescope frame female model Titanium grey colour, matt, size 51-19-145 Contact surfaces in the nasal area have to be adjustable and must not fall below the following values: with a total weight of < 25 g at least 250 mm 2 with a total weight of > 25 g at least 300 mm 2 935626 Titanium telescope frame male model Titanium grey colour, pearlescent, size 50-19-145 Note: SCHWEIZER frames are available in numerous different designs, colours and frame sizes. 12

Anatomic adjustment of the frame Shortest possible Corneal Vertex Distance (CVD) Same as during the testing procedure the CVD has to be as short as possible. As a result the user can take the best possible advantage of the field of view of the system. The system should be as close as possible to the eye but without the eyelashes touching the lens. Therefore SCHWEIZER offers different mounting lenses for the assembly of telescopic spectacles to ensure the optimum position of the system in front of the eye. Standard mounting lens with 932765 mounting slot 3 mm thickness, CR39, Ø 80 mm, pack of 2 pieces Already with the mounting lens it is possible to vary the CVD by up to 8,5 mm. Change of the CVD by 8,5 mm! Mounting lens inclusive adapter for 933265 back correction lens 15 mm Without convergence for adjustment of the CVD, pack of 2 pieces 13

The mechanical fitting of the telescopic spectacles (continued) Centre of rotation requirement Anatomic adjustment of the frame (continued) Pantoscopic angle and centre of rotation The appropriate pantoscopic angle is the basis for a comfortable posture of the head and the body. The centre of rotation requirement has to be fulfilled, this means the major visual direction and the optical axis of the system have to overlap. In order to achieve this with a head posture which is as relaxed as possible it is necessary to adjust the pantoscopic angle to the principle visual task. The frame plane is set in a way that it is positioned in a right angle to the major visual direction. If the telescopic spectacle is primarily used for watching television and if the user leans back in an armchair when watching television, maybe even putting their feet up, a greater pantoscopic angle is required than if they sit up with a straight posture on a chair in front of the television set. Adjustment tip from SCHWEIZER The habits and desires should be ascertained in detail. It for example is important to find out at which height the television set stands. The same also applies if the system is primarily used for near vision. If the visually impaired person reads at a reading stand they require a smaller pantoscopic angle than they do when reading in a writing posture leaning over the table without a reading stand. If the system is used for near vision and for distance vision an appropriate compromise should be made. 14

Correct adjustment of the pantoscopic angle of the frame The visually impaired person has to take the appropriate sitting position and the eye care professional controls from the side the pantoscopic angle. The pantoscopic angle has to be corrected until the frame plane is vertical to the major visual direction. In actual use the optical axis of the system is in a right angle to the frame plane. Major visual direction Determination of the visual points 1. 2. For the determination of the horizontal and vertical visual points there normally is applied the Viktorin s method. In this process the eyes of the test person and the eyes of the examiner face each other. The test person first looks into the examiner s left eye followed by their right eye. The respective visual points are marked on the lens, checked again and are corrected if necessary. Auge Closed eye geschlossen Examiner Prüfer 15

The mechanical fitting of the telescopic spectacles (continued) Determination of the visual points (continued) Systemträger Frame Mounting Trägerscheibe lens Eccentric fixation with head movement Interpupillary distance measurement If it already is noticed during the monocular refraction that the patient turns their head in one direction for fixation an eccentric fixation with head movement is evident. During the interpupillary distance measurement the patient should look at the eye care professional in a way that they can see the face or eyes of the eye care professional as good as possible. The visual points have to be marked in this position. In order to fulfil the centre of rotation requirement in this case, there will be used mounting lenses with convergence for 330 mm with the raised side in the direction of the head movement. Occluded or tinted mounting lenses In monocular telescopic spectacles the other eye is occluded. For this purpose there are available different options. The full lens can be occluded, partial areas can be left clear or only the pupil can be covered. In the case of a high glare sensitivity it can make sense to tint the mounting lenses and possibly to add a tinted side protection. Tinted mounting lenses also ease the fixation through the system and the contrast through the system seems to increase as well. 16

The dispensing of the telescopic spectacles When dispensing the telescopic spectacles the fit of the frame is controlled and the adjustment of the system is checked as these have to be tuned exactly. Checking the centration of a Galilei system Checking the centration For checking the centration of Galilei systems a penlight is used from the side shining between the system and the eye. By looking through the system from the front it now is possible to check the central position. With Kepler systems the penlight is used from the front shining through the system. From the side there is then visible the exit pupil light dot. This light dot has to overlap the pupil of the eye. Checking the centration of a Kepler system Adjustment tip from SCHWEIZER Control of the shortest possible CVD As a general rule the system has to be adjusted as close as possible to the eye. On systems with a real exit pupil such as all Kepler systems it is necessary that the exit pupil of the system overlaps the entrance pupil of the eye to see the telescopic image without vignetting. By lifting the telescopic spectacles slightly it is possible to check whether the CVD is adjusted correctly. At the correct CVD a slight lifting does not change the position of the visible area. A further lifting creates the impression that the full visible area suddenly is becoming darker. If the user claims that the image is getting darker from below and thus the visible area is moving upwards the CVD is too long. In the rare case that the CVD is too short the visible area moves downwards upon lifting and the image is getting darker from above. 17

The familiarisation The familiarisation with the new visual aid takes place at the reading stand. The reading stand enables reading in a relaxed posture and makes it easier to maintain the shorter distance. As the whole text is at the same distance from the eye the optimum sharpness is available to the user over the entire area of the text. If the reading material is on a flat table the upper part will lack sharpness as it already is outside of the system s focal length. The written material will only be clear in the lower part. The advantage of a reading stand is easily demonstrated by just folding the reading stand away once. If not before the user will now experience its advantages. The familiarisation naturally takes place with a light of the initially determined light temperature. To practice the exact reading distance it is necessary for the person to move very close to the reading material (they should smell the print ), before then slowly moving their head backwards until they find the optimum sharpness. When reading with telescopic systems it often is more pleasant not to move the head but to move the written material on the reading stand a little. This avoids the movement of the image which takes place when turning the head. 18

The conclusion With telescopic spectacles a visually impaired person can be assisted with both their near and distance vision. For many people concerned this combination represents the ideal solution for satisfying some of their individual basic visual requirements and also enables them to participate in social life. The eye care professional can make use of a wide range of options for choosing the most optimum solution for the person concerned. It is the case, however, that this one aid alone will rarely be enough for the visually impaired person. It is up to the eye care professional to offer them something adequate for their additional visual requirements and tasks. The Author Andreas Schaufler is a trained optician who has been working at SCHWEIZER since 1997. He has played a leading role in the development of the corporate identity and the brand image. Through his work he has made a significant contribution to the acceptance and today s wide level of interest in the subject of LowVision. In 2001 Andreas Schaufler completed an extra-occupational study course at the Bavarian Academy of Advertising and Marketing and is now Head of the Marketing Department at SCHWEIZER. He is the author of several professional papers on LowVision. This document in English language was translated from the original German version. 19

Do you have questions about our products or do you need further information? Please give us a call, we have the right specialists for you! Phone + 49-9191- 72 10 56 Fax + 49-9191- 72 10 73 E-Mail info@improvision-lvs.com Internet www.improvision-lvs.com 13-071 / 410128-EN ImproVision GmbH Hans-Böckler-Str. 7, 91301 Forchheim, Germany Phone: +49-9191-721056, Fax: +49-9191-721073 www.improvision-lvs.com