DISTRIBUTOR TECH DATA



Similar documents
K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

FRAME PROFILE MASONRY METAL DOOR FRAME FLUSH MASONRY KD MITER CORNER JOINT. #8 Screw (MS002485) Required on all fire rated KD frames. Bend Tabs.

INSTALLATION INSTRUCTIONS

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

DE Frame with C Series Sidelight

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

Technical Data Honeycomb Door Leaf

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

Brick Veneer Construction

n Three 4 x 4 butt hinges per door - prevents wracking and assures smooth positive operation n Heavy duty 16 gauge steel frame

Steel Door Frame Installation in Steel Stud Construction

Wood Sound Retardant Door Hardware Information Bulletin

Doors and frames. Technical data manual 2015 rev. 8/17/15

PANELIZED HOME INSTALLATION GUIDELINE

WINDOW PANNING AND TRIMS

March 14, Installation of Bay, Bow and Garden Windows

Installation S D I TECHNICAL DATA SERIES. and Troubleshooting Guide. for Standard Steel Doors and Frames STEEL DOOR INSTITUTE

Guidelines for Earthquake Bracing of Residential Water Heaters

PART 1 GENERAL 1.1 SECTION INCLUDES

INSTALLATION OF A BAY WINDOW

HMMA 830 HARDWARE SELECTION FOR HOLLOW METAL DOORS AND FRAMES HOLLOW METAL MANUAL -02 NAAMM STANDARD METAL DOORS & FRAMES NAAMM 01 NAAMM 01

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA METAL DOORS & FRAMES METAL. A Division of

Installation Instructions and Ordering Information

DOOR COMPONENTS, INC Technical Data

Nomenclature for: Standard Steel Doors and Frames

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

Clad Direct Glaze Window Installation Instructions

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

AMERICAN GOTHIC PLAYHOUSE

Guidelines for Earthquake Bracing Residential Water Heaters

Ceiling Mounted Folding Attic Ladders Installation Instructions

Window Installation Instructions

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

SECTION 6. Glass Storefront Doors:

Installing Window and Door Mouldings

Important Information for Installer & Homeowner

MGB Chrome Bumper Conversion

Superform Products Ltd.

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Stainless Steel Continuous Hinges

Best Barns USA Assembly Book

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

Sun Windows General Information Sun New Construction Window Installation Instructions

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

CLEAR-DIVISIONS VARIOFOLD

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Installation Guide for Andersen Architectural Wood Inswing Entry Doors

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

9300BC SERIES Light Commercial Door Closer

Installation Guide. Bath and Wall Surrounds SERIES B

CRASH RAIL INSTALLATION HEIGHT

Basement Window Installation Guide Hopper and Sliding

INSTALLATION INSTRUCTIONS for Premium Pocket Windows (JII022) IMPoRtaNt INFoRMatIoN & glossary. safety & HaNdlINg

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN

These instructions will show you how to install an internal door into a non-loadbearing partition wall. The instructions are split into three parts.

Introduction...COMB-2 Design Considerations and Examples...COMB-3

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

CLEAR-DIVISIONS CENTERFOLD

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

Installation Guide for Andersen Architectural Clad Outswing Commercial Doors

CONCEALED BEARING HINGES. StANLEy ARCHItECtuRAL HARDwARE

2.9 WINDOW & DOOR BUCKS

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Packaged Terminal Air Conditioner Wall Sleeve Installation

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

Cedar Cottage Doghouse Plans

WINDOW REPAIR MANUAL & REFERENCE GUIDE

CLEAR-DIVISIONS APERTO

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

Speed-Mat Rectangle Cutter

Hive Top Ventilation Shims

Sash Replacement Guide

Installation Instructions For Slider Casement Air Conditioners

SHOP NOTES METAL SHAPER FOR YOUR SHOP

security products metric sizes Redefine your comfort zone.

Slide the new steering column shaft through the steering column from the driver compartment.

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

6 RETROFITTING POST & PIER HOUSES

C. Codes and References: Comply with the version year adopted by the Authority Having Jurisdiction.

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

Owner's Manual & Assembly Instructions

GYPSUM AREA SEPARATION FIREWALLS GA

2. This is a close up of a typical area where the rocker is rusted out leaving holes under where the rocker moulding would be..

Tundra Series Windows January 2016

DIY CABINET REFACING INSTALLATION GUIDE

AZEK Rail Install Guide

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

Technical Information

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

RadianceRail Installation Guide

Vinyl Greenhouse Window Page 2 of 6 New Contruction Installation Instructions

Transcription:

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data INDEX SECTION 11 - FRAMES, GENERAL Technical Information: Prime Paint Data.........................................................11-002 Colorstyle Paint Data..................................................... 11-003 Frame, Door Opening Sizes and Hardware Provisions: 1-3/8 Door - Single and Double.......................................11-101 Hardware Locations - Standard 1-3/8 Door...................................11-102 1-3/ Door - Single and Double............................................ 11-103 Hardware Locations - Standard 1-3/ Door 6-8, 7-0, 7-2 High, -1/2 or 5 High Hinge............................. 11-10 7-10, 8-0, 9-0, 10-0 High, -1/2 or 5 High Hinge........................11-10A 5-0 Thru 10-0.................................................. 11-10B, 11-10C 6-8, 7-0, 7-2, 8-0 High, Dutch, -1/2 or 5 High Hinge....................11-10D Hardware Locations - Optional (NAAMM), 1-3/ Door 6-8, 7-0, 7-2 High, -1/2 High Hinge.................................. 11-105 7-10, 8-0, 9-0 High, -1/2 High Hinge................................. 11-105A 6-8, 7-0, 7-2 High, 5 High Hinge..................................... 11-106 7-10, 8-0, 9-0 High, 5 High Hinge.................................... 11-106A 1-3/8 Door Frames, Hinge and Strike Preparations.............................11-201 1-3/ Door Frames, -1/2 and 5 Hinge Preparations..........................11-202 1-3/ Door Frames, ANSI (-7/8 ) Strike Preparations........................... 11-203 1-3/ Cylindrical Strike Preparation..........................................11-20 Series SQW Weatherstrip Kerf Frame Hinge Preparation......................... 11-205 Series SQW Weatherstrip Kerf Frame Strike Preparation......................... 11-206 Full Depth Hinge Reinforcement............................................ 11-207 High Frequency Hinge Preparation...........................................11-208 1-3/8 and 1-3/ Door Frame Mute Application............................... 11-209 Reversible Flush Bolt Preparation............................................11-210 Frame Construction: Double Rabbet Frames, Die-cut, Welded Corner Assembly T-1......................................................11-301 Double Rabbet Frames, Die-cut, Welded Corner Assembly T-2, T-3.................................................. 11-302 Double Rabbet Frames, Die-cut, Welded Corner Assembly V-1, V-2..................................................11-303 Double Rabbet Frames, Die-cut, Welded Corner Assembly V-3......................................................11-30 Double Rabbet Frames, Miter-sawed, Welded Corner Assembly V-, V-5..................................................11-305 Double Rabbet Frames, Coped, Butted, Welded Corner Assembly V-7......................................................11-306 Double Rabbet Frames, Welded Junctions Assembly V-8, V-9..................................................11-307 11-001

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data INDEX SECTION 11 - FRAMES, GENERAL Hardware Reinforcements: Closer Reinforcements, Plate Type.......................................11-01, 11-02 Miscellaneous Hardware Reinforcements, Plate Type............................11-03 Frame Anchors: Anchor Quantity.........................................................11-500 Floor Anchors......................................................11-501 thru 11-503 Masonry Anchors.....................................................11-50, 11-505 Existing Opening Anchors.............................................11-505 thru 11-507 Wood Stud Anchors................................................... 11-508, 11-509 Metal Stud Anchors....................................................11-510, 11-511 Before Drywall Stud Anchor................................................11-512 Closure Clip............................................................. 11-512 Frame Splines............................................................11-513 Special Information: Standard Frame Installation............................................. 11-901, 11-902 Frame Spreader Bars......................................................11-903 11-001A

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data COLORSTYLE PAINT DATA DOOR FRAMES Process Data Factory-applied Colorstyle finish is a two-part, urethane top-coat that is electrostatically applied over the standard primer. The paint is then oven cured. The chemically reactive cure provides a top quality, abrasion resistant finish with excellent weathering characteristics. This finish is environmentally friendly in that it does not contain heavy metal pigments. 60 Gardner Gloss: 15 to 20. Colors: Standard color selectors available upon request. Performance Data Colorstyle, factory applied finish paint process has been subjected to the following tests: Salt Spray Humidity Accelerated Weathering Impact Film Adhesion Abrasion Factory applied Colorstyle finish paint meets the performance requirements and acceptance criteria as stated in ANSI Standard A250.3, Test Procedure and Acceptance Criteria for Factory Applied Finish Painted Steel Surfaces.... 11-003

NOMINAL SIZES 1-3/8 DOOR FRAME NOMINAL DOOR OPENING WIDTH NOMINAL DOOR OPENING WIDTH NOMINAL DOOR OPENING HEIGHT NOMINAL DOOR OPENING HEIGHT FINISH FLOOR SINGLE FRAME DOUBLE FRAME STANDARD DOOR OPENING SIZES OPENING HEIGHT SINGLE PAIR WIDTH WIDTH 2-0 -0 2- -8 2-6 5-0 2-8 5-2-10 5-8 3-0 6-0 6-8 7-0 7-2 FRAMES ON THIS PAGE ARE FOR USE WITH 1-3/8" THICK DOORS. 11-101

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data 1-3/8 DOOR FRAMES HINGE AND STRIKE LOCATIONS FRAME HEIGHTS 7-2 7-0 * 6-8 6-8 ( 32 16 15" ) 15" 32.93" (32 16 ) 32.93" 15" (31 16 ) 31.93" 15" (31 16 ) 31.93" 9.75" 15" (29 16 ) 29.93" 15" (29 16 ) 29.93" 3" ( 9 ) ( 59 7" ) 8 59.87" HINGE SPACING C L C L C L * Labeled 6-8 frames require 3 hinges. 2 hinges standard for non-labeled 6-8 frames 3 hinges optional for non-labeled 6-8 frames 0.31" STRIKE HEIGHT ( ) 0 5" 16 10.37" ( ) 10 3" 8 C L FRAME HEIGHTS STANDARD FRAME 7-2 7-0 6-8 9.75" 3" ( 9 ) C L 26.18" 2.18" ( 19 1" ) 2 19.5" (20 16 3" ) HINGE SPACING ( 26 3" 16 ) ( 2 3" 16 ) ( 20 3" 16 ) 20.18" C L C L C L STRIKE HEIGHT 20.18" 10.37" ( 10 3" 8 ) C L 33.62" ( 33 5" 8 ) DUTCH DOOR FRAME 11-102

NOMINAL SIZES 1-3/ DOOR FRAME SIZES NOMINAL DOOR OPENING WIDTH NOMINAL DOOR OPENING WIDTH NOMINAL DOOR OPENING HEIGHT NOMINAL DOOR OPENING HEIGHT FINISH FLOOR SINGLE FRAME DOUBLE FRAME STANDARD DOOR OPENING SIZES OPENING HEIGHT SINGLE PAIR WIDTH WIDTH 2-0 -0 2- -8 2-6 5-0 2-8 5-2-10 5-8 3-0 6-0 3-6-8 3-6 7-0 3-8 7-3-10 7-8 -0 8-0 5-0 10-0 6-8 7-0 7-2 7-10 8-0 9-0 10-0 11-103

Ceco Door Products DOOR OPENING HEIGHTS DISTRIBUTOR TECH DATA Distributor Tech Data STANDARD HARDWARE LOCATIONS 1-3/ DOOR FRAMES: 6-8, 7-0 & 7-2 HEIGHTS -1/2 OR 5 HIGH HINGES 7-2 7-0 6-8 9" C L 3" 33" HINGE SPACING 31" C L C L STRIKE HEIGHT 3" 33" 31" 1.81" ( ) 1 13" 16 9" C L These hardware locations are Ceco Door Products standard and will be furnished unless otherwise agreed to. 11-10

NOMINAL SIZES STANDARD HARDWARE LOCATIONS FOR 1-3/ DOOR FRAMES: 7-10, 8-0, 9-0, AND 10-0 HEIGHTS DOOR OPENING HEIGHTS 10-0 9-0 8-0 7-10 9" 3" 25.33" 30" 26" * 21" (25 6 ) C L C L 3" 3" 30" 30" 26" 26" ( 21" *25 ) 6 25.33" ( 21" *25 ) 6 25.33" HINGE SPACING C L C L 1.81" STRIKE HEIGHT ( ) 1 13" 16 C L 9" * 21/6" represents a measurable approximation to.33". These hardware locations are Ceco Door Products standard and will be furnished unless otherwise agreed to. 11-10A

NOMINAL SIZES FACTORY STANDARD HARDWARE LOCATIONS: HEIGHTS 5-0 THRU 10-0 OPENING HEIGHT NUMBER OF HINGES DIM "A" 5'-0" 2 2" OPENING HEIGHT NUMBER OF HINGES DIM "A" 5'-1" 3 2 @ 21.5" 5'-2" 3 2 @ 22" 5'-3" 3 2 @ 22.5" 5'-" 3 2 @ 23" 5'-5" 3 2 @ 23.5" 5'-6" 3 2 @ 2" 5'-7" 3 2 @ 2.5" 5'-8" 3 2 @ 25" 5'-9" 3 2 @ 25.5" 5'-10" 3 2 @ 26" 5'-11" 3 2 @ 26.5" 6'-0" 3 2 @ 27" 6'-1" 3 2 @ 27.5" 6'-2" 3 2 @ 28" 6'-3" 3 2 @ 28.5" 6'-" 3 2 @ 29" 6'-5" 3 2 @ 29.5" 6'-6" 3 2 @ 30" 6'-7" 3 2 @ 30.5" 6'-8" 3 2 @ 31" 6'-9" 3 2 @ 31.5" 6'-10" 3 2 @ 32" 6'-11" 3 2 @ 32.5" 7'-0" 3 2 @ 33" 7'-1" 3 2 @ 33.5" 7'-2" 3 2 @ 3" 7'-3" 3 2 @ 3.5" 7'-" 3 2 @ 35" 7'-5" 3 2 @ 35.5" 7'-6" 3 2 @ 36" OPENING HEIGHT NUMBER OF HINGES DIM "A" 7'-7" 3 @ 2.33" 7'-8" 7'-9" 7'-10" 7'-11" 8'-0" 8'-1" 8'-2" 8'-3" 8'-" 8'-5" 8'-6" 8'-7" 8'-8" 8'-9" 8'-10" 8'-11" 9'-0" 9'-1" 9'-2" 9'-3" 9'-" 9'-5" 9'-6" 9'-7" 9'-8" 9'-9" 9'-10" 9'-11" 10'-0" 3 @ 2.66" 3 @ 25" 3 @ 25.33" 3 @ 25.66" 3 @ 26" 3 @ 26.33" 3 @ 26.66" 3 @ 27" 3 @ 27.33" 3 @ 27.66" 3 @ 28" 3 @ 28.33" 3 @ 28.66" 3 @ 29" 3 @ 29.33" 3 @ 29.66" 3 @ 30" 3 @ 30.33" 3 @ 30.66" 3 @ 31" 3 @ 31.33" 3 @ 31.66" 3 @ 32" 3 @ 32.33" 3 @ 32.66" 3 @ 33" 3 @ 33.33" 3 @ 33.66" 3 @ 3" 11-10C

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data STANDARD HARDWARE LOCATIONS, 1-3/ DUTCH FRAMES: 6-8, 7-0, 7-2 & 8-0 HEIGHTS - -1/2 OR 5 HIGH HINGES DOOR OPENING HEIGHTS 8-0 7-2 7-0 6-8 9" C L 38.31" 22 5" ( 17 3" 8 ) 17.37" HINGE SPACING 28.31" 26.31" 22.31" ( 38 5" 16 ) 5" ( 28 16 ) 5" ( 26 16 ) 22.31" ( 16 ) 5" ( 22 16 ) LC LC LC 33.62" STRIKE HEIGHT ( 33 5" 8 ) LC 9" These hardware locations are Ceco Door Products standard and will be furnished unless otherwise agreed to. 11-10D

NOMINAL SIZES NAAMM ALTERNATE HDWE LOCATIONS, 1-3/ DOOR FRAMES: 6-8, 7-0 & 7-2 HEIGHTS -1/2 HIGH HINGES DOOR OPENING HEIGHTS HARDWARE LOCATIONS SHOWN BELOW ARE BASED ON THE FOLLOWING: 5" from head to top of upper hinge. 10" from bottom of jamb to bottom of lower hinge. Equal spacing between intermediate hinges. 7-2 7-0 6-8 7.25" ( 7 1" ) LC 33.25" 32.25" 30.25" HINGE SPACING 33.25" 32.25" 30.25" ( 33 1" ) ) (32 1" ) (30 1" ) (33 1" ( 32 1" ) ( 30 1" ) LC Strike Height On Frame Is Dependent On Knob Or Crossbar Height. Refer To Door Hardware Locations (p. 01-03) And Manufacturer's Lock Template To Determine Relationship Between Lock And Strike. 12.25" ( 12 1" ) LC The above hardware locations will be furnished only when agreed to. 11-105

NOMINAL SIZES NAAMM HDWE LOCATIONS, 1-3/ DOOR FRAMES: 7-10, 8-0, 9-0, AND 10-0 HEIGHTS - -1/2 HIGH HINGES DOOR OPENING HEIGHTS HARDWARE LOCATIONS SHOWN BELOW ARE BASED ON THE FOLLOWING: 5" from head to top of upper hinge. 10" from bottom of jamb to bottom of lower hinge. Equal spacing between intermediate hinges. 10-0 9-0 8-0 7-10 ) ( 33 1" 33.5" 2 ) ( 33 1" 33.5" 2 ( 33 1" ) 33.5" 2 29 ) ( 1" 7.25" 2 29.5" 29 ) ( 1" 2 29.5" ( 29 1" ) 29.5" 2 25 1" 2 ) ( ( 25 1" ) 1" ( 7 ) 25.5" 25 1" 2 ) ( 25.5" 25.5" 2 * ) 53" 6 (2 53" 2.83" (2 6 2.83" HINGE SPACING * ) * 53" (2 6 ) 2.83" C L CL C L Strike Height On Frame Is Dependent On Knob Or Crossbar Height. Refer To Door Hardware Locations (p. 01-03a) And Manufacturer's Lock Template To Determine Relationship Between Lock And Strike. 12.25" ( 12 1" ) LC * 53/6" represents a measurable approximation to.83". The above hardware locations will be furnished only when agreed to. 11-105A

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data NAAMM ALTERNATE HDWE LOCATIONS, 1-3/ DOOR FRAMES: 6-8, 7-0 & 7-2 HEIGHTS 5 HIGH HINGES HARDWARE LOCATIONS SHOWN BELOW ARE BASED ON THE FOLLOWING: DOOR OPENING HEIGHTS 5" from head to top of upper hinge. 10" from bottom of jamb to bottom of lower hinge. Equal spacing between intermediate hinges. 7-2 7-0 6-8 7.5" ( 7 1" 2 ) LC 33" 33" 32" 30" 32" 30" HINGE SPACING LC Strike Height On Frame Is Dependent On Knob Or Crossbar Height. Refer To Door Hardware Locations (p. 01-0) And Manufacturer's Lock Template To Determine Relationship Between Lock And Strike. 12.5" ( 12 1" 2 ) LC The above hardware locations will be furnished only when agreed to. 11-106

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data NAAMM ALTERNATE HDWE LOCATIONS 1-3/ DOOR FRAMES: 7-10, 8-0, 9-0 AND 10-0 HEIGHTS - 5 HIGH HINGES HARDWARE LOCATIONS SHOWN BELOW ARE BASED ON THE FOLLOWING: DOOR OPENING HEIGHTS 5" from head to top of upper hinge. 10" from bottom of jamb to bottom of lower hinge. Equal spacing between intermediate hinges. 10-0 9-0 8-0 7-10 7.5" ( 7 1" 2 ) * * * * 21" (33 6 ) 21" (29 6 ) 21" (25 6 ) C L CL C L Strike Height On Frame Is Dependent On Knob Or Crossbar Height. Refer To Door Hardware Locations (p. 01-0a) And Manufacturer's Lock Template To Determine Relationship Between Lock And Strike. 33.33" 29.33" 21" (2 32 ) 25.33" 2.66" 33.33" * ) ( 33 21" 6 33.33" ) ( 33 21" 6 29.33" * 29 21" ( 6 ) 29.33" 29 21" ( 6 ) 25.33" ) 21" ( 25 6 25.33" ) 21" ( 25 6 2.66" ( ) * * * * * * 2 2.66" 32 21" HINGE SPACING ( 2 32 21" ) 12.5" ( 12 1" 2 ) LC * 21/6" represents a measurable approximation to.33". * 21/32" represents a measurable approximation to.66". The above hardware locations will be furnished only when agreed to. 11-106A

NOMINAL SIZES 1-3/8 DOOR FRAME STRIKE AND HINGE PREPS 3/16"(NOM.) BACKSET 1-5/32" 7/32" 16 GAGE STRIKE REINFORCEMENT 16 GAGE FORMED STEEL STRIKE REINF. PROJECTION WELDED (2) PLACES EACH END PIERCE, DRAW AND TAP FOR #8-32 MS TO PROVIDE A MIN. 1/8" THREAD DEPTH 21/6" PLASTER GUARD FORMED AS PART OF STRIKE REINF. 1-17/32" 2-1/8" 2-25/32" 1-1/" (NOM.) 5/16"(NOM.) BACKSET STRIKE REINFORCEMENT USE WITH CYLINDRICAL LOCKS ONLY (1-1/8" x 2-3/" "T" STRIKE) PLASTER GUARD 1-9/16" 1-1/" 21/6" FACE NOTCH VARIES PER FRAME GAGE 26 GAGE STEEL PLASTER GUARD IS SNAPPED-IN PLACE AFTER HINGE REINF. IS WELDED TO JAMB 23/6" 1-25/6" 3-1/2" 8" 1-25/6" 3/8" 21/6" 12 GA. HINGE REINF. PROJECTION WELDED TO FRAME (3) PLACES EACH END 23/6" FACE NOTCH VARIES PER FRAME GAGE 1-9/16" TAPPED HOLES FOR #10-2 MS (3) PLACES HINGE PREPARATION FOR USE WITH 3-1/2" HIGH TEMPLATE HINGES (ANSI A156.7) 11-201

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data 1-3/ DOOR FRAME -1/2 & 5 HINGE PREPS 11-202

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data 1-3/ DOOR FRAME CYLINDRICAL STRIKE PREPARATION 3" 8 (NOM.) BACKSET PLASTER GUARD FORMED AS PART OF STRIKE REINFORCEMENT 1 5" 32 CUTOUT 13" 32 16 GAGE FORMED STEEL STRIKE REINFORCEMENT PROJECTION WELDED (2) PLACES EACH END PIERCE, DRAW AND TAP FOR #8-32 MS TO PROVIDE A MINIMUM 1/8" THREAD DEPTH 21" 6 1 17" 32 2 1" 8 2 25" 32 21" 6 1 15" 16 11-20

NOMINAL SIZES SERIES SQW WEATHERSTRIP KERF FRAME HINGE PREPARATION 1-5/8" (N0M.) 1/2"(NOM.) BACKSET TAPPED HOLE FOR #12-2 M.S. () PLACES ELEVATED PIPS REMAIN INTACT FOR.13 HINGES BUT MUST BE REMOVED FOR.180 HINGES () PLACES 1-1/" 26 GAGE STEEL PLASTER GUARD IS SNAPPED-IN PLACE. HINGE REINFORCEMENT IS WELDED TO JAMB. PLASTER GUARD 9" 1/2" -1/2" 2 1-1/8" 1-1/" 1-1/8" 1/2" FIT FOAM FILLED WEATHERSTRIP TO FRAME AFTER FINISH PAINTING 2-1/8" FACE NOTCH VARIES PER FRAME GAGE AND HINGE WEIGHT 1-1/" 7 GAGE HINGE REINFORCEMENT PROJECTION WELDED TO FRAME () PLACES EACH END -1/2" HINGE PREP FOR USE WITH -1/2" HIGH TEMPLATE HINGES (ANSI A156.7) 26 GAGE STEEL PLASTER GUARD IS SNAPPED-IN PLACE. HINGE REINFORCEMENT IS WELDED TO JAMB. 1-5/8" (N0M.) 1/2"(NOM.) BACKSET 5/16" 5/8" TAPPED HOLE FOR #12-2 MS () PLACES PLASTER GUARD 1/2" 9" 5" 1-1/" 1-1/2" 7 GAGE HINGE REINFORCEMENT PROJECTION WELDED () PLACES EACH END 1-1/" 2 5/16" 5/8" 1/2" FACE NOTCH VARIES PER FRAME GAGE AND HINGE WEIGHT 2-1/8" 5" HINGE PREP FOR USE WITH 5" HIGH TEMPLATE HINGES (ANSI A156.7) 11-205

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data SERIES CF PROFILE WK WEATHERSTRIP - KERF FRAME STRIKE PREPARATION 1" 2 BACKSET (NOM.) 1 9" 32 CUTOUT 11" 32 PUNCH AND TAP FOR 12-2 MS (2) PLACES 12 GAGE STEEL STRIKE REINF. PLATE - PROJECTION WELDED TO FRAME (6) PLACES 26 GAGE STEEL SNAP-IN PLASTER GUARD 9" 16 BACKSET (NOM.) 1 5" 32 CUTOUT 13" 32 2 1" 8 3 13" 32 25" 6 1" 8 25" 6 29" 32 16 GAGE FORMED STEEL STRIKE REINF. PROJECTION WELDED (2) PLACES EACH END PIERCE, DRAW AND TAP FOR #8-32 MS TO PROVIDE A MIN. 1/8" THREAD DEPTH FIT FOAM FILLED WEATHERSTRIP TO FRAME AFTER FINISH PAINTING 1 17" 32 2 1" 8 6 21" 2 25" 32 16 GAGE STRIKE REINFORCEMENT 1" 2 8 FACE NOTCH VARIES PER FRAME GAGE 21" 6 PLASTER GUARD FORMED AS PART OF STRIKE REINF. 11-206

NOMINAL SIZES 1-3/ DOOR FRAME, FULL DEPTH HINGE REINFORCEMENT FRAME WIDTH LESS 1/2" 5" (NOM) 16 BACKSET 1 5" 8 (NOM.) XX X X 12" XXXX TAPPED HOLE FOR #12-2 MS () PLACES 5" 16 5" 8 1" 2 7 GAGE HINGE REINFORCEMENT WELDED TO FRAME 1" 1 8 1" 2 1 1" 1" 1 8 XXXX 1" 2 XXXX AVAILABLE FOR FRAME DEPTHS 5-1/2" THRU 10-5/8" 1 15" 16-1/2" HIGH HINGE APPLICATION SHOWN 11-207

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data DOOR FRAME HIGH FREQUENCY HINGE REINFORCEMENT STRAP 3 " 2" 5/8" STOP 1 8 " 1" 1/" LONG ARC WELDS (3) PLACES PER STRAP STEEL STRAP HINGE REINFORCEMENT AND PLASTER GUARD APPLIED PER PAGE #11-202 11-208

NOMINAL SIZES DOOR FRAME MUTES SINGLE SWING DOOR FRAMES - 3 MUTES DOUBLE SWING DOOR FRAMES - 2 MUTES DUTCH DOOR FRAMES - MUTES 12" MAX. M 6" ON CENTER M M M 9 3/" MAX. M = MUTE C L OF STRIKE SINGLE SWING M 12" MAX. DOUBLE SWING STANDARD LOCATION OF DOOR MUTES 1. 2. 3. INSERT BLUNT END OF 3/32" DIAMETER WIRE OR TOOL IN HOLE IN CENTER OF MUTE. MOISTEN CONE PORTION AND INSERT IN HOLE IN STOP OF FRAME, PUSHING SLOWLY WITH CIRCULAR MOTION TO ELONGATE MUTE SUFFICIENTLY TO SET IN PLACE. REMOVE WIRE Fed. Spec. Type 1337A DOOR MUTES (SILENCERS) MAINTAIN PROPER SPACE (1/16") BETWEEN DOOR AND FRAME STOP AND CUSHION DOOR CLOSING. INSERT MUTES INTO FRAME BEFORE FRAME IS INSTALLED INTO WALL TO PREVENT GROUT, PLASTER, ETC. FROM FILLING HOLES. 11-209

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data REVERSIBLE FLUSH BOLT PREPARATION Center of cutout and door Center line of Door Opening Width and Cutout Part A HEAD 15/16" RRA/LA shown Flip flop Part B for LRA/RA Weld Part A to Head at each side Part B Note 1 Pips are provided for projection welding. If other welding is used, flip Part A over. Tackweld Part E on back of reinforcement as necessary. PLASTER GUARD RFB Assembly Parts A,B, and D as listed below: A. (12 ga. galv. steel) Note 1 Tapped for #8-32 MS Part A REINFORCEMENT B. (16 ga. galv. steel, prime paint) C. (16 ga. galv. steel, prime paint) Part B STRIKE D. #8-32 x 1/2" UCFHMS (2) E. Plaster guard (Included on SU and SQ frames only) Part C STRIKE FILLER Part D 11-210

NOMINAL SIZES DIE-CUT, DOUBLE-RABBET FRAME WELDED CORNER ASSEMBLY Reference: This corner has a full and continuous backbend at the head and jambs. It can be used on frames that cap the wall. STANDARD KD HEAD 1. Assemble frame: Bend tabs after assuring that face-miter seam is "closed" and "tight". Bend corner reinforcement tabs toward inside (toward throat) of frame. Bend rabbet tabs towards outside (toward jamb backbends). 2. Place weld bead as required at the joint of the head and jamb soffits from the backside. 2a. If weld penetration occurs, file smooth. 2b. Spot paint STANDARD KD JAMB Narrow Stop FACE-MITER SEAM IS VISIBLE NARROW STOP (up to 1-1/2" wide) One 1/2" (minimum) length stitch weld, located in the center of the soffit. WIDE STOP (1-1/2" wide and up) Wide Stop: Two 1/2" long stitch welds located at each end of the head and jamb soffit seam. WELDING TYPE T-1 "STITCH WELD at SOFFIT ONLY" Standard KD frame components from stock with corner reinforcements. NO SAWING REQUIRED. WELDING TYPE T-1 11-301

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data DIE-CUT, DOUBLE-RABBET FRAME WELDED CORNER ASSEMBLY 1. Assemble frame: Bend tabs after assuring that face-miter seam is "closed" and "tight" Bend corner reinforcement tabs toward inside (toward throat) of frame. Bend rabbet tabs toward outside(toward jamb backbends) of frame. 2. Weld the entire face-miter seam, between head and jamb, from the outside (both faces). 3. Grind and dress smooth both face-miter seams after welding. 3a. Spot paint STANDARD KD HEAD 2 FACE-MITER SEAM IS COMPLETELY INVISBLE STANDARD KD JAMB T-2 WELDING TYPE T-2 "OUTSIDE FACE WELD ONLY" Standard KD frame components from stock with corner reinforcements. NO SAW CUTTING REQUIRED. Reference: This corner has a full and continuous backbend at the head and jambs. It can be used on frames that cap the wall. STANDARD KD HEAD Reference: This corner has a full and continuous backbend at the head and jambs. It can be used on frames that cap the wall. 1. Assemble frame: Bend tabs after assuring that face-miter seam is "closed" and "tight" Bend corner reinforcement tabs toward inside (toward throat) of frame. Bend rabbet tabs toward outside(toward jamb backbends) of frame. 2. Weld the entire face-miter seam, between head and jamb, from the outside (Both faces). STANDARD KD JAMB 3. Grind an dress smooth both face-miter seams after welding. FACE-MITER SEAM IS COMPLETELY INVISIBLE. Weld the entire web seam (including the seams between head and jamb rabbets, stops and soffits) from the backside, with a continuous weld bead. a. If weld penetration occurs, file smooth. T-3 5. Spot paint WELDING TYPE T-2 "OUTSIDE FACE WELD and FULL WEB WELD" Standard KD frame components from stock with corner reinforcements. NO SAW CUTTING REQUIRED. 11-302

NOMINAL SIZES DIE-CUT, DOUBLE-RABBET FRAME WELDED CORNER ASSEMBLY Reference: This corner has a full and continuous backbend at the head and jambs. It can be used on frames that cap the wall. rabbet tabs toward outside (toward jamb backbends) face-miter seam is "closed" and "tight". Bend 1. Assemble frame: Bend tabs after assuring that of frame. DIE-CUT HEAD 2. Weld the entire face-miter seam from the inside. Weld is to penetrate to exterior. 2a. Grind the exterior face and fill as necessary. FACE-MITER SEAM IS COMPLETELY INVISIBLE DIE-CUT JAMB V-2 WELDING TYPE V-2 " INSIDE FACE WELD ONLY" Die-cut frame components - VOID OF CORNER REINFORCEMENTS NO SAW CUTTING REQUIRED 11-303

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data DIE-CUT, DOUBLE RABBET FRAME WELDED CORNER ASSEMBLY 1. Assemble frame: Bend tabs after assuring that face-miter seam is "closed" and tight. Bend rabbet tabs toward outside (toward jamb backbends) of frame. 2. Weld the entire face-miter seam from the inside. Weld is to penetrate to exterior. 2a. Grind the exterior face and fill as necessary. FACE-MITER SEAM IS COMPLETELY INVISIBLE Reference: This corner has a full and continuous backbend at the head and jambs. It can be used on frames that cap the wall. 3. Dress reworked areas.. Weld the entire web seam (including the seams between head and jamb rabbets, stops, and soffits) from the backside with a continuous weld bead. a. If weld penetration occurs, file smooth. 5. Spot weld. 2 DIE-CUT HEAD V-3 WELDING TYPE V-3 "INSIDE FACE WELD and FULL WEB WELD" Die-cut frame components - VOID OF CORNER REINFORCEMENTS NO SAW CUTTING REQUIRED. DIE-CUT JAMB 11-30

1a. Clamp the head and jamb at 90.

2. Clamp head and jamb at 90.

frame sections is 90.

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data & 6 HOSTPITAL STOPS 11-308

NOMINAL SIZES CLOSER REINFORCEMENT PLATE TYPE REINFORCEMENT PLATE: 1 GAGE MIN. STEEL x 1/3/" x 1" (1) Note: If 1-3/" dimension is too big to fit face...decrease size to suit. REINFORCEMENT PLATE: 1 GAGE MIN. STEEL x 1/3/" x 1" (1) Note: If 1-3/" dimension is too big to fit stop..decrease size to suit. PLACE FLAT AGAINST INSIDE OF FACE AND " 1" BUTT AGAINST INSIDE 2" 1" OF DOOR RABBET. HEAD HEAD PLACE FLAT AGAINST INSIDE OF DOOR SOFFIT AND BUTT AGAINST INSIDE OF DOOR STOP (1) 1" LONG (APPROX) STITCH WELD AT EACH END OF PLATE DOOR RABBET (1) 1" LONG (APPROX) STITCH WELD AT EACH END OF PLATE DOOR RABBET LOCATION OF OPTIONAL PLATE, SEE 11-02 HINGE JAMB HINGE JAMB Note: Verify against manufacturer's template that size and position of plate satisfy hardware needs. REGULAR ARM CLOSER MOUNTING PARALLEL ARM CLOSER MOUNTING REINFORCEMENT PLATE: 1 GAGE MIN. STEEL x 1/3/" x 1" (2) Note: If 1-3/" dimension is too big to fit stop...decrease size to suit. REINFORCEMENT PLATE: 1 GAGE MIN. STEEL x 1/3/" x 1" (1) Note: If 1-3/" dimension is too big to fit face...decrease size to suit. 1" HEAD PLACE FLAT AGAINST INSIDE OF DOOR SOFFIT AND BUTT AGAINST INSIDE OF DOOR STOP 2" 1" HEAD PLACE FLAT AGAINST INSIDE OF FACE AND BUTT AGAINST INSIDE OF HEAD BACKBEND. 1" (1) 1" LONG (APPROX) STITCH WELD AT EACH END OF EACH PLATE (1) 1" LONG (APPROX) DOOR STITCH WELD AT EACH RABBET END OF PLATE HINGE JAMB Note: Do not use with standard DW plumb anchor. Not recommended when door opening height is less than 7'-'0". DOOR RABBET STOP HINGE JAMB CORNER BRACKET CLOSER MOUNTING TOP JAMB CLOSER MOUNTING 11-01

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data CLOSER REINFORCEMENT PLATE TYPE REINFORCEMENT PLATE: 1 GAGE MIN. STEEL x 1/3/" x 1" (1) Note: If 1-3/" dimension is too big to fit face..decrease size to suit. REINFORCEMENT PLATE: 1 GAGE MIN. STEEL x 1/3/" x 1" (1) Note: If 1-3/" dimension is too big to fit stop..decrease size to suit. PLACE FLAT AGAINST IN- SIDE OF RABBET OPPOSITE 2" 1" DOOR AND BUTT AGAINST 7" INSIDE OF DOOR FACE HEAD 1" HEAD PLACE FLAT AGAINST INSIDE OF DOOR SOFFIT AND BUTT AGAINST INSIDE OF DOOR STOP (1) 1" LONG (APPROX) STITCH WELD AT EACH END OF PLATE DOOR RABBET LOCATION OF OPTIONAL PLATE, SEE 11-01 (1) 1" LONG (APPROX) STITCH WELD AT EACH END OF PLATE CL of opening DOOR RABBET HINGE JAMB Note: Verify against manufacturer's template that size and position of plate satisfy hardware needs. PARALLEL ARM CLOSER MOUNTING Note: Verify against manufacturer's template that size and position of plate satisfy hardware needs. OUTSWING DOOR: SURFACE BOLTS AND REMOVABLE MULLIONS REINFORCEMENT PLATE: 1 GAGE MIN. STEEL x 1/3/" x 1" (1) REINFORCEMENT PLATE: 1 GAGE MIN. STEEL x 1/3/" x 1" (1) Note: If 1-3/" dimension is too big to fit face..decrease size to suit. 7" 1" HEAD PLACE FLAT AGAINST INSIDE OF FACE AND BUTT AGAINST INSIDE OF DOOR RABBET Note: If 1-3/" dimension is too big to fit stop..decrease size to suit. PLACE FLAT AGAINST INSIDE OF DOOR SOFFIT AND BUTT AGAINST INSIDE OF DOOR STOP 1" DOOR RABBET 7" cl (1) 1" LONG (APPROX) STITCH WELD AT EACH END OF PLATE DOOR RABBET (1) 1" LONG (APPROX) STITCH WELD AT EACH END OF PLATE CL of opening Note: Verify against manufacturer's template that size and position of plate satisfy hardware needs. 33-5/16" 0-5/16" INSWING DOOR: SURFACE BOLTS RIM TYPE PANIC DEVICE MOUNTING BOTTOM OF STRIKE JAMB 11-02

NOMINAL SIZES HALF-CLOSER REINFORCEMENT " 13-7/8" HEAD CR/HALF DOOR SIDE 1GA. GALV. STL. 1-5/8" 13-7/8" 1-31/32" 5/8" HINGE JAMB REGULAR & PARALLEL ARM CLOSER MOUNTING 1-1/2" SPOT OR TACK WELDED IN PLACE. (2) WELDS PER END 2" MIN. FACE FRAME HEAD SECTION 1-15/16" RABBET 11-03

NOMINAL SIZES JAMB ANCHOR QUANTITIES FOR STANDARD HEIGHT FRAMES ANCHOR TYPE QUANTITY JAMB ANCHORS PER FRAME 6-8 THRU 7-2 7-10 THRU 10-0 FLOOR ANCHORS PER FRAME NEW MASONRY 6 8 2 EXISTING OPENING 8 10 OMIT WOOD STUD 6 8 2 * METAL STUD 6 8 2 * SOLID PLASTER 6 8 2 * LAMINATED DRYWALL 6 8 2 * * Floor anchors may be omitted and replaced with two additional jamb anchors. Unless otherwise indicated, jamb anchors are normally located on the same center line as the hinge preparations except where interference would occur with hardware reinforcements. Where interference would occur, anchors should be positioned above or below hinge reinforcements and directly opposite on the strike jamb. For sizes other than listed above, the following guidelines are followed (unless otherwise indicated)...for heights to 6-0: Two jamb anchors per jamb; For heights greater than 6-0 thru 7-6: Three jamb anchors per jamb; For heights greater than 7-6 thru 10-0: Four jamb anchors per jamb; and for each additional 2 feet of height or fraction thereof: One additional jamb anchor per jamb. 11-500

NOMINAL SIZES WELDED FLOOR ANCHOR WELD 11/16 11/16 CENTER OF JAMB AND ANCHOR WELD TWO PIECE APPLICATION ONE PIECE APPLICATION 3-1/8 1-1/2 5/16 DIA. HOLES 1-1/2 1-7/16 5/16 DIA. HOLES 1/2 1/2 1" CTC SPACES 1-23/32 1/2 1/2 DIM A 16 GAGE GALV STEEL TWO PIECE ANCHOR (16 GA. GALV.) (16 GA. COLD ROLLED) ONE PIECE ANCHOR SELECTION CHART DIM A FRAME DEPTH HOLES 3-1/2 5 6-1/2 8-1/2 to 5-1/ 5-3/8 to 6-3/ 6-7/8 to 8-1/ 8-3/ to 9-3/ All dimensions are in inches. For SI conversion: 1" = 25. mm. Anchors for depths outside the above range are made to order. 3 5 6 8 11-501

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data ADJUSTABLE FLOOR ANCHOR " TRAVEL HAT: -1/" WIDE x 3/" LEGS x 5/8" OFFSET @ 3-1/" LONG 2-1/8" ANGLE: 1-1/2" x 6-3/" @ 2-3/" LONG SCREW: #10 x 3/" THSMS FLUSH WITH JAMB BOTTOM 5/16" DIA. 2-1/8" O.A. 11-502

NOMINAL SIZES SIDELITE FLOOR ANCHOR Note: Anchor is attached to floor at two places. Mullion or sill is slipped over anchor (fastening is optional). IMPOST IMPOST FOR VERTICAL MULLIONS FLOOR 12 GAGE STEEL (2) 9/32" DIA. HOLES Dim A Dim A = Depth (-) 3/16" FOR BASE SILLS FLOOR Dim A SILL BRACING STRAP Note: Position sill anchor to avoid possible interference with sill bracing strap if present. Dim A = Depth (-) 1-3/16" (assuming 1/2" backbends) 11-503

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data ANCHORS FOR NEW MASONRY 7 GAGE GALV. STEEL WIRE THROAT RANGE 2 THRU 8-3/ R 1-1/" 8" WIRE MASONRY ANCHOR 1 MFG DEPTH FIELD MODIFIED DEPTH 3 3 3 3 3 1 5 1 2" 5-3/ 5-1/ -3/ -1/ 3-3/ 3-3/ - - -1/ 3-3/ 2-5/16" 9-3/8" SPOTWELDED All dimensions are in inches; for SI conversion, 1" = 25. mm. 16 GAGE GALV STEEL 2" DEPTH 6-3/ 7-3/ 8-1/" 8-3/ MASONRY "T" ANCHOR 1-13/16" 11-50

NOMINAL SIZES MASONRY ANCHORS CONT. EXISTING OPENING ANCHOR WELDED Available on special order only FOR ALL FRAME DEPTHS YOKE AND STRAP MASONRY ANCHOR Available on special order only EXISTING OPENING ANCHOR 11-505

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data EXISTING OPENING STANDARD JAMB ANCHOR 11-506

NOMINAL SIZES EXISTING OPENING ANCHOR FOR SPECIAL FACES 1-1/ 1 1/8 1 3-1/ 1-1/2 DIM A EXISTING OPENING/NARROW EXISTING OPENING/NARROW ANCHOR SIZE CHART FACE 1 1-1/ 1-1/2 1-3/ 2 2-1/2 DIM A 1-9/16 1-13/16 2-1/16 2-5/16 2-9/16 3-1/16 All dimensions are in inches. For SI conversion: 1" = 25.mm. Dimension A assumes a 5/8 frame stop height. Suggested Rough-opening clearance: 1/" @ head and jambs. See page 11-506 for jamb punching, spacing, fastener, and floor anchor notes. 11-507

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data WELDED WOOD STUD ANCHOR The wood stud anchor depicted below is shop attached. Unless otherwise designated, a stud anchor will be attached at each sill in lieu of a floor anchor. MSZ1 ANCHOR SPOT WELDED TO JAMB 5/32 DIA. HOLES (2) PLACES EACH STRAP STRAP ANCHOR SPOT WELDED TO MSZ1 ANCHOR 18 GAGE STEEL PORTION OF JAMB REMOVED FOR CLARITY *DIM "X" JAMB * Or to suit other stud sizes. For stud sizes other than shown below: actual stud dimension should be noted. Also, wall board thicknesses should be shown so that straps can be properly positioned. TO SUIT WALL Straps are nailed to stud by contractor 3/16 5/8 JAMB DEPTH EQUALS WALL THICKNESS PLUS 1-1/8 WOOD STUD ANCHOR SELECTION CHART STUD SIZE 2 x 2 x 6 DIM "X" 3-1/2 5-1/2 Wood blocking by contractor as necessary. WALL SECTION INSTALLATION SEQUENCE 1. WALL FRAMING 2. DOOR FRAME 3. WALL SURFACE MATERIAL All dimensions are in inches, for SI conversion, 1" = 25. mm. 11-508

8 7 6 1 8 NOMINAL SIZES ADJUSTABLE JAMB ANCHOR FOR STUD WALLS FRAME ANCHOR NAILS OR SCREWS WALL STUD Wood stud shown Metal stud similar HOLLOW METAL FRAME WALL BOARD TYPICAL APPLICATION ASSEMBLY DETAIL (END VIEW) 5 6 Anchors are adjustable in 1/8" increments within given ranges. FRAME DEPTH: 3-3/" thru 6-1/" FRAME DEPTH: 6-1/" thru 8-3/" 11-509

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data WELDED METAL STUD ANCHOR RECESSED TYPE The metal stud anchor depicted below is shop attached. Unless otherwise designated, a stud anchor will be provided for each sill. ZEE ANCHOR (1x1-1/x1 @ Dim "A" long) SPOT WELDED TO JAMB 18 GAGE STEEL For single rabbet depths over inches, a 3/ x 5/8 x 3/ x 1 long steel "zee" clip is welded to MSZ anchor and stop as necessary EQUAL EQUAL DIM "A" JAMB Stud is screwed to anchor 5/8 If second stud is used, attach it after jamb is fastened. DIM FRAME "A" DEPTH RANGE 3-1/2-1/2 THRU 5-1/ 5 5-3/8 THRU 6-3/ 6-1/2 6-7/8 THRU 8-1/ 8 8-3/8 THRU 9-3/ WALL SECTION INSTALLATION SEQUENCE 1. DOOR FRAME 2. WALL FRAMING 3. WALL SURFACE MATERIAL All dimensions are in inches, for SI conversion, 1" = 25. mm. 11-510

NOMINAL SIZES WELDED METAL STUD ANCHOR FLUSH TYPE The metal stud anchor depicted below is shop attached. at sill. Designate if floor anchor or jamb anchor is desired 16 GAGE STEEL DIM "B" DIM "A" DIM "C" For single rabbet depths over inches, a 3/ x 5/8 x 3/ x 1 long steel "zee" clip is welded to MSZ anchor and stop as necessary DIM "B" DIM DIM "A" "B" -5/8 13/16 5-7/8 1-7/16 7-1/2 2-1/8 DIM FRAME "C" DEPTH RANGE 3 5-3/8 THRU 6 3 6-1/8 THRU 7-5/8 3-1/ 7-3/ THRU 9-1/ Stud is screwed to anchor Allow 3/16" clearance between stud and jamb Shim Anchor is normally positioned in the center of throat to accommodate equal thicknesses of wallboard at each side of stud. If wall is not symmetrical, drawings showing condition should be provided. INSTALLATION SEQUENCE If second stud is used, attach it after jamb is fastened. 1. WALL FRAMING 2. DOOR FRAME 3. WALL SURFACE MATERIAL Series BQ should be considered All dimensions are in inches, for SI conversion, 1" = 25. mm. 11-511

Ceco Door Products DISTRIBUTOR TECH DATA Distributor Tech Data BEFOR DRYWALL STUD ANCHOR AND CLOSURE CLIP FOR 2" FACE 1-1/16 C L BEND HERE FOR ONE LAYER OF 1/2" > 5/8" WALLBOARD BEND HERE FOR TWO LAYERS OF 1/2" > 5/8" WALLBOARD TAP-IN PLACE C L 3/ 18 GAGE GALV STEEL 5-5/8 9/16 BEND STUD SIZE 2 FACE NOTE FRAME IS SET-UP AND JAMBS ANCHORED BEFORE WALLBOARD IS INSTALLED. STUD ANCHORS ARE BENT IN FIELD TO THICKNESS OF WALLBOARD. IF WALL FRAME WORK IS SET UP BEFORE DOOR FRAME, USE AN ADDITIONAL JAMB ANCHOR AT SILL INSTEAD OF SILL ANCHOR. BEFORE DRYWALL STUD ANCHOR All dimensions are in inches, for SI conversion, 1" = 25. mm. 1-5/16 3/ 7/32 R. WELD TO JAMB Contractor snaps closure into place after frame is installed. JAMB 16 GAGE STEEL SILL CLIP AT EACH END AND 2" O.C. 1/2" BACKBENDS CLOSURE CLIP 11-512

NOMINAL SIZES FRAME SPLINES Frame components should have open ends. Mitered corners prevent spline installation without modification of backbend. Allot one spline for every 2 feet of impost height. Drive spline in from ends, locate approx. equal distance from one another. Stitchweld 8" 16 Ga. steel 1" 3/32" DEPTH REWORK FSPA 3-7/8" or OVER 33 SPLINE APPLICATION -3/" or OVER 3 5-3/" or OVER 53 6-3/" or OVER 63 For shipping via common carrier, frame size should not exceed 8'-0" in more than one dimension. SPLINE APPLICATION (For Custom Depths) 11-513

NOMINAL SIZES FRAME INSTALLATION MASONRY AND STUD WALLS JOBSITE STORAGE: Store frames off the ground on wood runners or skids. Do not store directly on the ground. Cover frames with tarpaulin or plastic but do insure that adequate ventilation is provided to eliminate moisture condensation. When frames are to be fully grouted and when plaster or mortar contain "anti-freeze" agents, the inside of the frames should be coated with a bituminous, water-resistant paint by the installation contractor. ASSEMBLY of FRAME SLOTS FOR CORNER TABS HEAD CORNER TABS JAMB BEND CORNER TABS TOWARD INSIDE OF FRAME CORNER ASSEMBLY SLOTS FOR JAMB TABS JAMB TABS Install rubber silencers before frame is setup to avoid grout plugging holes. BEND JAMB TABS TOWARD OUTSIDE OF FRAME PLUMBING FRAME FRAME DEPTH DOOR OPG AT HEAD SQUARING THE FRAME The installer should use wood spreaders (as described at right), a carpenters level (the longer the better), and a carpenters square (the bigger the better). Set the frame in the desired location. Level head and plumb jambs. Shim under jambs if necessary. SPREADER Typical wood spreader must be square and made from lumber at least 1" thick. Length of spreader equals door opening width at the head. Cut clearance notches for frame stops as shown. Spreader must be nearly as wide as frame depth for proper installation. 11-901

90

NOMINAL SIZES X X X X FRAME SPREADER BARS 1. SPREADER BAR PROFILE 2. SPREADER BAR LENGTH Length of spreader bar is equivalent to door opening width dimension. This bar is not to be used for installation. A wood spreader is to be used for maintaining proper spacing between jambs. (See the DHI publication "The Installation of Commercial Steel Doors and Steel Frames", "Insulated Steel Doors in Wood Frames", and "Builder's Hardware"). DOOR RABBET 3. SPREADER BAR QUANTITY AND LOCATION A. All single rabbet frames and double rabbet, single swing frames with depth not exceeding 6 inches: attach (1) spreader bar to the door rabbet. (See Fig. #1) SPREADER B. All double rabbet, double swing frames or double rabbet, single swing frames with depth exceeding 6 inches: attach one (1) spreader bar to each frame rabbet (two total). (see Fig. #2) Fig. #1 X X X X X JAMB. SPREADER BAR ATTACHMENT Verify spreader bar length by checking to see that said length is equivalent to the door opening width dimension at head. Place the spreader bar at the bottom of the door opening and tack weld in place. Strength of welds should be such that spreader bar remains in place during transit and also be such that the spreader bar can be removed when required (by means of a sharp hammer blow) without incurring frame damage. JAMB SPREADERS Fig. #2 X X X X BOTH RABBETS 11-903