INSTALLATION INSTRUCTION Touch Panel Switch with Occupancy Sensor



Similar documents
LOS 2500 SUPER CEILING SENSOR. Installation Manual

STR7 Low Profile LED Strip Luminaire

Operating instructions IV / 2007

Drayton Digistat +2RF/+3RF

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

Motion Activated Camera User Manual

Big Ass Light High Bay LED

Roadstar Installation Instruction Manual

Operating instructions II / 2004

OLS-2100 Occupancy Light Switch

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

767 Diagnostic System

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Wireless Home Security Alarm System AM 500

NUMERIC SIGN SP2-6XX / 180mm. Presentation

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

HERZ-Thermal Actuators

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

1247 Norwood Avenue, Itasca, IL (800)

PUCK LED 3W, 12V AC/DC REV

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Installation & Maintenance Instructions

Installation Instructions. Thermo Call TC3

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

How To Read A Pipe From A Sensor

DCDC-USB. 6-34V 10A, Intelligent DC-DC converter with USB interface. Quick Installation Guide Version 1.0c P/N DCDC-USB

MOUNTING AND OPERATING INSTRUCTIONS

bba - Balboa Bluetooth Audio (AMP) Installation & User Guide

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Ducoterra Radiant Heating Panel Installation Manual

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

LED MOTION ACTIVATED FLOOD LIGHT

EBDSPIR-PRM, EBDSPIR-PRM-IP

Portable Air Conditioner

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

NFLS-x Series Flexible LED Flexible Light Strip

PUCK LED 3W, 12V AC/DC REV

Installation Instructions

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

GE Lighting. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABH2 - Series) imagination at work

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

INSTRUCTION FOR THE USER

Charge Regulator SCR 12 Marine

Universal Voltage Terminal Photoelectric E3JM

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

5W LED Energy Saver PIR Bulkhead

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Analogue + IVS Electronic Throttle Controls for CUMMINS Engines

NUMERIC SIGN SP2-6XX / 100mm. Presentation

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

RC8061 Pan and Tilt Camera Installation Guide

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Advantium 2 Plus Alarm

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

RC8021 Indoor Camera Installation Guide

Model: DC-A2IO Advanced HVAC Controller

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

DOT LED 1W, 12V AC/DC

PowlVac Vacuum Integrity Tester

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

FTDI VCP DRIVER (free) (WIN/MAC/LINUX)

Provides one channel for Ethernet over existing

Radiant Temperature Sensor TY7321

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

LED LIGHTING CATALOG 2014 vol.1. FLEX 3in1 multi

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Provides one channel for Ethernet over existing

TS93 EMR T/PT/TDE. Surface applied door closer

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

id led 4" square housing FL44

User Manual Door Camera

T-100-R Installation Guide

Dual Technology Ceiling Mount Sensor

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

Digital Keypad Use s Manual

Color Mark Sensor with Red or Green LED E3S-VS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DLP-PU/E Instruction Manual

High Bay Occupancy Sensor Selection Guide

16/32 Channel 1U Rack Mount CCTV Power Supply

Projector Dowser Userʼs Manual Part # 4160

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

SAFETY RECOMMENDATION

9452/9453 Installation and User Guide

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Transcription:

CAUTION : KEEP FROM HEAT AND METAL SURFACES This product is designed for use indoors with general electronic devices. voltage and current must meet specifications Use certified wires and cables for installation Not recommended to mount touch panel on metal surfaces PRECAUTION : GARDER DES SURFACES DE CHALEUR ET DES MÉTAUX Ce produit est conçu pour un usage en intérieur avec des appareils électroniques générales. Tension et le courant doit répondre aux exigences d entrée Utiliser des fils et des câbles certifiés pour l installation Ne montez pas l écran tactile sur des surfaces métalliques FEATURES: Intelligent motion and touch switch control of luminaires based on occupancy. Low-profile design compatible with a wide range of low voltage LED lighting luminaires. Output wattage is based on the power supply (sold separately) and luminaire (sold separately) specifications. Refer to these specs for proper installation. Programmed with three functions: and To activate both motion sensor and touch switch. Only touch switch, inactivate motion sensor. Only motion sensor, inactivate touch switch. Built-in adjustable timer on motion sensor allows automatic shut off after the sensor covered area is vacated. Maximum time delay is 20 minutes (20MIN), minimum is 10 seconds (10S). Motion sensor supplied with 18ft wire and touch panel supplied with 8ft wire. May be cut to desired length. Lengthen of wire is not recommended as will decrease sensitivity. Two different mounting options (screw or double sided tape mounting) for all undercabinet application included. Choose appropriate mounting option for rough, smooth and curved surfaces. Designed for indoor undercabinet application. Recommended ambient temperature is 14 to 122 F (-10 to 50 C) Controller Motion Sensor Touch Panel 1s 1a 1w 1s 4 5 1 10S 20MIN w Mounting distance 4x Mounting distance 1 INSTALLATION: 1. AND SEE (P. 3-4) 2. SEE (P. 5-6) 3. SEE (P. 7-8) SPECIFICATION : : 12/24V, Output: 12/24V, retains the right to modify the design of our products at any time as part of the company's continuous improvement program. December, 2014 1

MOTION COVERAGE Maximum detection angle and distance chart for Motion sensor: Side View Front View 8 Max 4.9 8 16 16 Max 16.4 Lower Sensitivity 8 Motion sensor 0 120 Motion sensor 0 Higher Sensitivity 8 Max 16.4 Lower Sensitivity Sample Application for Function 1) and Designed for indoor undercabinet application. The recommended ambient temperature is 14 to 122 F (-10 to 50 C). Recommended to use with Low Voltage LED (12V or 24V) undercabinet products. To achieve better result, install motion sensor with lens facing side ways and touch panel within sensor coverage range. Task luminaire Occupancy Sensor Touch Switch retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DeCember, 2014 2

R INSTALLATION INSTRUCTION AND - Before installation, layout the application and determine the mounting locations of Motion Sensor, and the Touch Panel. - Install within luminaires motion sensor coverage range (p.2) and adjust motion sensor to the direction of detection area to achieve best sensitivity (detection range: 120 and 16 feet). Note: Touch Panel supplied with 8 feet wire, Motion Sensor supplied with 18 feet wire. Wires may be field cuttable. WIRING OVERVIEW (Fig.1) Cover Output Cover 8 feet wire Touch Panel Install within motion sensor coverage range (see p.2) Controller Motion Sensor 18 feet wire Sensor Lens Detection angle: 120 Detection Distance: 16 feet Timer To set light off time: min. 10S (10 seconds) to max. 20MIN (20 Minutes) Luminaire (sold separately) C US Intertek INPUT 4008592 Controller with occupancy sensor and touch on-off function 12/24V For use with LED luminaire s CM WT YL RD BK OUTPUT 12/24V Black Wire White Wire Yellow Wire Red Wire Black Wire Touch panel Motion Sensor Luminaire (Sold separately) and retains the right to modify the design of our products at any time as part of the company's continuous improvement program. December, 2014 3

1. Make sure controller switch position to and. 2. Mount the motion sensor by using screw or double sided tape (Fig. 2) with the lens facing the direction where the best detection range of human movement for optimal coverage. Detection angle is 120 and max distance is 16 feet (see p. 2 for sample kitchen application and coverage chart). 3. Mount the touch panel by using screws or double sided tape (Fig. 3) within motion sensor s coverage range. 4. Mount controller by using screws or double sided tape (Fig. 4). Open the input/output cover of controller by screw to connect motion sensor, touch panel, luminaires and power supply (see Fig.1 for wiring instruction). 5. Screw back the input and output covers of the controller. The input/output covers are designed to press and secure the wires in position. Motion Sensor Screw Mounting: (Fig. 2) Use screws to mount the installation board. Fix the sensor on the board with clips. Suitable for wood cabinets with rough finishes or curved surfaces Motion Sensor Tape Mounting: Use double sided tape to mount the sensor. Board Touch Panel Screw Mounting: (Fig. 3) Use screw to mount the touch panel. Caution: Do not install on metal surfaces. Touch Panel Tape Mounting: Use double sided tape to mount the touch panel. Controller Screw Mounting: (Fig. 4) Open the input and output covers of controller. Use screws to mount by waist shaped holes. Controller Tape Mounting: Use double sided tape to mount the controller. retains the right to modify the design of our products at any time as part of the company's continuous improvement program. December, 2014 4

R INSTALLATION INSTRUCTION - Before installation, layout the application and determine the mounting locations of touch panel and luminaires. Note: Touch panel supplied with 8 feet wire. Wires may be field cuttable. WIRING OVERVIEW (Fig.5) Cover Output Cover 8 feet wire Touch Panel Controller Luminaire (sold separately) C US Intertek INPUT 4008592 Controller with occupancy sensor and touch on-off function 12/24V For use with LED luminaire s CM WT YL RD BK OUTPUT 12/24V Black Wire Touch panel Luminaire (Sold separately) and retains the right to modify the design of our products at any time as part of the company's continuous improvement program. December, 2014 5

1. Make sure controller switch position to. 2. Mount the touch panel by using screw or double sided tape (Fig. 6). 3. Mount controller by using screws or double sided tape (Fig. 7). Open the input and output covers of controller to connect, the touch panel, luminaires and power supply to the controller (see Fig.5 for wiring instruction). 4. Screw back the input and output covers of the controller. The input/output covers designed to press and secure the wires position. Touch Panel Screw Mounting: (Fig. 6) Use screw to mount the touch panel. Caution: Do not install on metal surfaces. Touch Panel Tape Mounting: Use double sided tape to mount the touch panel. Controller Screw Mounting: (Fig. 7) Open the input and output cover of controller. Use screws to mount by waist shaped holes. Controller Tape Mounting: Use double sided tape to mount the controller. retains the right to modify the design of our products at any time as part of the company's continuous improvement program. December, 2014 6

R INSTALLATION INSTRUCTION - Before installation, layout the application and determine the mounting location of motion sensor and luminaires. Adjust motion sensor to the direction of detection area to achieve best sensitivity (detection range: 120 and 16 feet). Note: Motion Sensor supplied with 18 feet wire. Wires may be field cuttable. WIRING OVERVIEW (Fig.8) Cover Output Cover 18 feet wire Controller Motion Sensor Sensor Lens Detection angle: 120 Detection Distance: 16 feet Timer To set light off time: min. 10S (10 seconds) to max. 20MIN (20 Minutes) Luminaire (sold separately) C US Intertek INPUT 4008592 Controller with occupancy sensor and touch on-off function 12/24V For use with LED luminaire s CM WT YL RD BK OUTPUT 12/24V White Wire Yellow Wire Red Wire Black Wire Motion Sensor Luminaire (Sold separately) and retains the right to modify the design of our products at any time as part of the company's continuous improvement program. December, 2014 7

1. Make sure controller switch position to. 2. Mount the motion sensor by using screws or double sided tape (Fig. 9) with the lens facing the direction where the best detection range of human movement for optimal coverage. Detection angle is 120 and max distance is 16 feet (see p. 2 for sample kitchen application and coverage chart). 3. Mount controller by using screw or double sided tape (Fig. 10). Open the input and output cover of controller to connect motion sensor, luminaires and power supply to the controller (see Fig.8 for wiring instruction). 4. Close the input and output cover of controller by screw. The input/output covers are designed to press and secure the wires in position. Motion Sensor Screw Mounting: (Fig. 9) Use screws to mount the installation board. Fix the sensor on the board with clips. Suitable for wood cabinets with rough finishes or curved surfaces Motion Sensor Tape Mounting: Use double sided tape to mount the sensor. Board Controller Screw Mounting: (Fig. 10) Open the input and output cover of controller. Use screws to mount by waist shaped holes. Controller Tape Mounting: Use double sided tape to mount the controller. retains the right to modify the design of our products at any time as part of the company's continuous improvement program. December, 2014 8