Improved Energy Efficiency for Data Center Cooling Fans



Similar documents
Application of CFD modelling to the Design of Modern Data Centres

Pushing the limits. Turbine simulation for next-generation turbochargers

University Turbine Systems Research 2012 Fellowship Program Final Report. Prepared for: General Electric Company

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Thinking Outside the Box Server Design for Data Center Optimization

Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360

Using CFD to improve the design of a circulating water channel

Unique Airflow Visualization Techniques for the Design and Validation of Above-Plenum Data Center CFD Models

Characteristics of Centrifugal Blower and Its Effective Use in High Static Pressure Area

Thermal Analysis, Heat Sink Design and Performance Verification for GE Fanuc Intelligent Platform s WANic 3860 Packet Processor PCI Card

PUTTING THE SPIN IN CFD

Understanding How Cabinet Door Perforation Impacts Airflow by Travis North

INFLUENCE OF VARIATION IN CPU UTILIZATION ON THE RACK LEVEL FAN CONFIGURATION AS A COOLING TECHNIQUE FOR HIGH END SERVERS SHREYAS NAGARAJ

FAN PROTECTION AGAINST STALLING PHENOMENON

Modeling Rack and Server Heat Capacity in a Physics Based Dynamic CFD Model of Data Centers. Sami Alkharabsheh, Bahgat Sammakia 10/28/2013

Fan Basics and Selection Criteria (How to Use)

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial

Compatibility and Accuracy of Mesh Generation in HyperMesh and CFD Simulation with Acusolve for Torque Converter

Thermoelectric Generator (TEG) for Heavy Diesel Trucks John C. Bass, Aleksandr S. Kushch, Norbert B. Elsner Hi-Z Technology, Inc.

IT Cost Savings Audit. Information Technology Report. Prepared for XYZ Inc. November 2009

Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Analysis of the UNH Data Center Using CFD Modeling

Benefits of Cold Aisle Containment During Cooling Failure

CFD Analysis of a butterfly valve in a compressible fluid

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

Performance prediction of a centrifugal pump working in direct and reverse mode using Computational Fluid Dynamics

Effect of Rack Server Population on Temperatures in Data Centers

Using Simulation to Improve Data Center Efficiency

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Flow in data racks. 1 Aim/Motivation. 3 Data rack modification. 2 Current state. EPJ Web of Conferences 67, (2014)

CFD ANALYSIS OF CONTROLLABLE PITCH PROPELLER USED IN MARINE VEHICLE

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

ME6130 An introduction to CFD 1-1

Express Introductory Training in ANSYS Fluent Lecture 1 Introduction to the CFD Methodology

COMPUTATIONAL FLUID DYNAMICS (CFD) ANALYSIS OF INTERMEDIATE PRESSURE STEAM TURBINE

Introduction: Keywords: CFD, MRF, Blower Angular Orientation

Chapter 3.5: Fans and Blowers

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

DataCenter 2020: first results for energy-optimization at existing data centers

RESEARCH PROJECTS. For more information about our research projects please contact us at:

Rapid Design of an optimized Radial Compressor using CFturbo and ANSYS

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

The CEETHERM Data Center Laboratory

Eco Pelmet Modelling and Assessment. CFD Based Study. Report Number R1D1. 13 January 2015

Computational Modeling of Wind Turbines in OpenFOAM

Development of Ventilation Strategy in Diesel Engine Power Plant by Using CFD Modelling

Access Server Rack Cabinet Compatibility Guide

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

AN EFFECT OF GRID QUALITY ON THE RESULTS OF NUMERICAL SIMULATIONS OF THE FLUID FLOW FIELD IN AN AGITATED VESSEL

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

Battery Thermal Management System Design Modeling

Using CFD for optimal thermal management and cooling design in data centers

FAC 2.1: Data Center Cooling Simulation. Jacob Harris, Application Engineer Yue Ma, Senior Product Manager

A TEST RIG FOR TESTING HIGH PRESSURE CENTRIFUGAL COMPRESSORS MODEL STAGES AT HIGH REYNOLDS NUMBER

Centrifugal Fans and Pumps are sized to meet the maximum

Power Supply, Cooling and Mechanical Technologies for Green IT

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

Model 1210C Battery Powered Pump Shown. Description

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

Use of OpenFoam in a CFD analysis of a finger type slug catcher. Dynaflow Conference 2011 January , Rotterdam, the Netherlands

Practice Problems on Boundary Layers. Answer(s): D = 107 N D = 152 N. C. Wassgren, Purdue University Page 1 of 17 Last Updated: 2010 Nov 22

Accurate Air Flow Measurement in Electronics Cooling

CFD analysis for road vehicles - case study

Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity

CFD Beyond the Whitespace. Datacentres Central & Eastern Europe

A Simplified 3d Model Approach in Constructing the Plain Vane Profile of A Radial Type Submersible Pump Impeller

FINE TM /Marine. CFD Suite for Marine Applications. Advanced Development for Better Products.

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

Pros and Cons. of CFD and Physical Flow Modeling. A White Paper by: Kevin W. Linfield, Ph.D., P.E. Robert G. Mudry, P.E.

CHAPTER 1. Introduction to CAD/CAM/CAE Systems

SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER

2013 Code_Saturne User Group Meeting. EDF R&D Chatou, France. 9 th April 2013

Reducing Data Center Energy Consumption

Server Chassis and Triplet Hardware v1.0

How To Model With Cfd Using Phoenics

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

O.F.Wind Wind Site Assessment Simulation in complex terrain based on OpenFOAM. Darmstadt,

The Influence of Aerodynamics on the Design of High-Performance Road Vehicles

How To Run A Data Center Efficiently

Application of CFD in connection with ship design

Shrinking a power supply and the challenge to maintain high reliability.

1150 hp motor design, electromagnetic and thermal analysis

COOKING THE ROOF CFD BEYOND THE WHITE SPACE

CONVERGE Features, Capabilities and Applications

Gas Handling and Power Consumption of High Solidity Hydrofoils:

Experimental investigation of golf driver club head drag reduction through the use of aerodynamic features on the driver crown

Mixing in the process industry: Chemicals Food Pharmaceuticals Paper Polymers Minerals Environmental. Chemical Industry:

Keywords: CFD, heat turbomachinery, Compound Lean Nozzle, Controlled Flow Nozzle, efficiency.

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Module 6 Case Studies

Experiment 3 Pipe Friction

Transcription:

Improved Energy Efficiency for Data Center Cooling Fans Kimberly Penney, PAX Scientific, Inc. Cecelia Golden, California Energy Commission ABSTRACT Data centers worldwide use about 3 billion watts of electricity per year, with the US making up one-quarter to one-third of that load (Glanz 212). Rack servers in data centers produce excess heat as a byproduct of computation, and require internal cooling fans to cool Central Processing Units (CPUs) and other components. These fans use significant energy, which is parasitic in that it does not go toward any actual computing task. PAX Scientific, Inc. (PAX) has developed the Streamlining Principle, a technology based on principles of fluid movement in biological systems. When applied to fan geometries, the Streamlining Principle creates fans that are significantly more energy efficient than fans designed by conventional means, and quieter, since noise reflects wasted energy. PAX technology was demonstrated and tested by Cisco Systems in San Jose, California, where PAX fans were compared to the fans in Cisco s Nexus 7 Series server switch. The demonstration was highly successful, with a power drop by PAX fans of 35%-45% for matched cooling. This greatly exceeded the original goal of 15%. PAX fans can be manufactured with the similar cost and processes as current fans and have potential applicability to data centers worldwide. This report includes project specifications, information on the development of the fan design, and results of experimental testing. This project was partially funded by a grant from the California Energy Commission s research and development program. Project Overview PAX Scientific, Inc. (PAX) is a California-based research and licensing company that specializes in innovative solutions for fluid-related industrial problems using biomimicry. Biomimicry is an emerging field of engineering design that seeks to emulate the energy-efficient systems that have evolved in the natural world. After recognizing that spiraling flows could be found in all forms of nature, naturalist and PAX CEO Jay Harman used that observation to identify a set of geometries that nature applies ubiquitously to reduce friction and drag in flow structures, plants, and animals. Harman patented these geometries as they apply to many product areas in a range of industries including fans, blowers, mixers, thermal products, propellers, pumps, and turbines. PAX geometries bring a variety of benefits to products, including: Friction and drag reduction in fluid handling Reduction in fluid noise/cavitations Improved energy efficiency in rotating blade and propulsion mechanisms Improved structural integrity in surface profiles Reduced environmental impact 215 ACEEE Summer Study on Energy Efficiency in Industry 6-1

Application Computer servers, and their associated cooling and auxiliary infrastructure, account for roughly 1.7-2.2% of the total electricity demand in the United States (Koomey 211). Large server farms are intense users of electricity and they are sited based on electricity cost and availability. Servers, in addition to being located in air-conditioned rooms, primarily cool themselves by means of several small fans mounted in the chassis of the device. These pull air across the circuit boards and other vital components. These fans are typically 4-15mm in size and use up to 2 watts of power per fan. The number of fans per system varies directly with the computing power; 12 to 24 fans per server chassis are not uncommon. Project Goal The goal of this project was to demonstrate a 15% reduction in the energy consumption of server fans by retrofitting a commercially-available server with PAX s biomimetic fans. In order to achieve this, PAX: Partnered with Cisco Systems, Inc. and Jabil Circuit. Cisco is a worldwide leader in IT hardware and software and Jabil is a supply chain management and manufacturing partner that currently provides many components, including fans, to Cisco. Iterated in-house design tools (analytic and computational fluid dynamics) to prepare them for server-specific fan designs. Designed a fan optimized for the selected server and completed baseline tests. Fabricated pre-production samples. Installed PAX fans in a server and monitored power usage under typical operating conditions to compare with current best-in-class server fans. Project Specifications Server Selection The server fan chosen to target was a mid-range 12x12x38mm fan. This type of fan is a typical server chassis and is very power intensive. Cisco currently uses this fan in its line of Nexus server switches: a 9-slot chassis and an 18-slot chassis. The 18-slot version uses 24 of the 12x12x38mm fans and the 9-slot version, referred to as Boxster, uses 12 of these fans. Both Cisco servers sell approximately 1, - 2, units/month, equivalent to 5, - 8, of the 12mm fans per year for the 5-7 year lifetime of each server. Each fan uses about 1.1Amps (at 48Volts), which can account for as much as 25% of the total power usage to the server. The Boxster is a 9-slot server chassis of approximate dimensions 18 x24 x24 shown below in Figure 1. The total power usage in the chassis is 6KW at maximum. The cooling fans are installed into a tray that slides into the back of the chassis for assembly. The fan tray has 12-12x38mm fans and 6-8x38mm fans. One side of the chassis is perforated with hexagonal 2mm holes where the air enters. Air is pulled across the server nodes (perpendicular to the rack) by the fans that are flush with the outlet wall of the chassis (also with perforated hexagonal holes). This server typically ships with a combination of Delta or Nidec fans. In order to isolate the 12x38mm fan performance, the 8x38mm fans were not powered during in-unit testing. 6-2 215 ACEEE Summer Study on Energy Efficiency in Industry

Figure 1: Boxster front view with fans visible Competitor Fan The primary fan for comparison was the Nidec Model T12E5BS2M7-7, shown below in Figure 4. The outer casing is 12mm x 12mm x 38mm. The fan has an imbedded 5V motor, and the speed is controlled using pulse-width-modulation software. The 12mm x 12mm x 38mm Delta Model AFC1248DE was also compared. These fans currently ship in the majority of Boxster units and were identified by Cisco as being best-in class. The baseline data for the fans are shown below in Figures 2 and 3. Performance & Speed for Midrange 12x38mm Nidec T12E5BS2M7 (43V) 1.4 6 Static Pressure [inwg] 1.2 1.8.6.4 Nidec Sample#1 Nidec Sample#2 Nidec Sample#3 Sample #1 Spd. Sample#2 Spd. Sample#3 Spd. 5 4 3 2 Speed [RPM].2 1 5 1 15 2 25 3 Figure 2: Airflow & Speed Baseline Data 215 ACEEE Summer Study on Energy Efficiency in Industry 6-3

Performance & Power for Midrange 12x38mm Nidec T12E5BS2M7 (43V) 1.4 45 Static Pressure [inwg] 1.2 1.8.6.4 Nidec Sample#1 Nidec Sample#2 Nidec Sample#3 Sample #1 Pwr. Sample#2 Pwr. Sample#3 Pwr. 4 35 3 25 2 15 1 Power Draw [W].2 5 5 1 15 2 25 3 Figure 3: Power Baseline Data Test Procedure with Correlation Figure 4: Upstream and Downstream View of Competitor Fan To demonstrate the PAX fan power reduction in a repeatible, real-world environment, a test procedure in accordance with AMCA 21 and international standards was developed in collaboration with Cisco. Initial fan-alone airflow and noise tests were completed at the PAX Fan Laboratory in San Rafael, California. The tests with fans installed in the server were completed at the Cisco Test Laboratories in San Jose, California. A high level of correlation was found between the two facilities. Shown below in Figures 5 and 6 are the single fan data for the midrange 12x38mm fan that Cisco uses in the Boxster chassis. Cisco also provided PAX with an operating point that represents the system resistance imposed on the fan by the fully loaded chassis. Using the performance curves and the system resistance data, PAX can approximate how the fan will perform when installed in the Boxster chassis. The curves below show the midrange Nidec fan performance in a single fan test at two different speeds. 6-4 215 ACEEE Summer Study on Energy Efficiency in Industry

Performance for Midrange 12x38mm Single Fan Test (Voltage Marked) 1.6 1.4 Nidec 48V (6rpm) Static Pressure [inwg] 1.2 1.8.6 Nidec 32V (45rpm) Boxter System Resistance.4.2 5 1 15 2 25 3 7 Power Draw for Midrange 12x38mm Single Fan Test (Voltage Marked) 6 Power [W] 5 4 3 2 Nidec 48V (6rpm) Nidec 32V (45rpm) Low Operating Point High Operating Point 1 5 1 15 2 25 3 Figure 5 & 6: Baseline Single Fan Airflow & Power Data PAX Lab Following testing at the PAX facility, twelve Nidec fans were brought to the Cisco test facility for testing. Using the operating point predictions for airflow from the PAX tests, approximated values were compared to the actual values tested in the chassis at Cisco. PAX approximated the output at 138CFM and 16CFM at the 1% and 6% duty cycle operating points, respectively. Actual airflow values per fan were 141CFM and 14CFM, respectively. These match very closely and power predictions also correlated. 215 ACEEE Summer Study on Energy Efficiency in Industry 6-5

PAX Effort: CFD Overview PAX engineers use CFD simulations both as a performance predictor and, more importantly, as a flow visualization tool. By studying the pressure contours and velocity contours along the blade surfaces and in the downstream vortex, PAX can reduce areas of unwanted turbulence and improve performance. Before PAX used CFD simulations for its fan design process, it investigated various geometric, grid, and physical modeling assumptions to establish a method with good experimental correlation. PAX s first task was to find the proper geometric control volume for defining the CFD model. It was determined that modeling the actual 1 CFM flowmeter tunnel in the PAX Laboratory would give the best correlation. This flow meter has two basic sections. The first section is where the fan and its shroud/housing is mounted flush to the front plexiglas surface. The next section allows the air to either exit to ambient, if the rear plexiglas surface is removed, or exit to a large flexible hose that is connected to a blower, which can be operated in tandem with a pivoting baffle over the flexible hose exit to control flow rate through the flowmeter tunnel. Figure 7 below shows this simplified flowmeter tunnel geometry, with an information technology (IT) fan attached to the right and an 3-inch exit nozzle on the left showing typical air particle paths. Figure 7: 1cfm Flowmeter Tunnel and Simplified Flowmeter Tunnel In order to finalize the computational control volume geometry, one must define the means by which the flow rate and pressure drop (operating point) will be regulated multiple times in order to define a fan curve. A novel approach is to model a large portion of the surrounding test area s high bay and drive the flow only by the fan and its rotation. With this approach, different operating points can be achieved by changing the exit nozzle diameter and geometric shape. In this manner, no inlet or outlet boundary conditions need to be specified. For the second task, PAX carried out a mesh sensitivity study. The goal in crafting a proper specification of isotropic mesh sizes (and viscous layer sizes) is to explore how mesh size variation effects the primary fan performance measure for a given simulation (pressure drop, flow rate and torque of the fan). In this way, a serious attempt to make the predicted results independent of the grid was executed. All simulations were carried out using PAX s High Performance Cluster (HPC). The cluster has a head node and 16 compute nodes for a total of 192 cores that include Infiniband interconnects to improve inter-processor communication and decrease memory latency. Two different commercial CFD packages were used: AcuSolve from Altair Engineering and STAR_CCM+ from CD_ADAPCO. Simulations were completed using both steady and unsteady 6-6 215 ACEEE Summer Study on Energy Efficiency in Industry

physical modeling, to help remove any potential error in the computed results due to not properly resolving temporal features of the flow. Comparing CFD and experimental curves indicated that the CFD results for the commercial cooling fan were good and those of the IT fan were fair. Both sets of fan curves showed that steady MRF simulations were not as accurate, so one should run unsteady simulations if possible. The fact that AcuSolve and STAR_CCM+ both produced similar unsteady results confirmed that simulations with basically the same ingredients gave the same results. For the remainder of the project, experimental results were used to accurately characterize the overall performance of each fan design. However, the CFD simulation was still useful. In particular, its added value was to provide fine grain flow characteristics for a given baseline fan operating point and another improved fan design variant nominated by PAX s Fan Parameter Optimizer (see next section) as a means to understand WHY certain parameter changes improve or reduce fan performance. Visualization of the three-dimensional fan flow regime (pressure, velocity and turbulence) is a real benefit. PAX Fan Parameter Optimizer The first challenge in applying the PAX optimization process to cooling fans was to develop an efficient optimization objective function specific to a cooling fan. The mathematical formulation of the optimization problem is given by ( ) = argmin (, ) where is the cost function, is the set of geometrical parameters, is the set of operating conditions (such as flow, pressure, power, etc.) and is the optimum set of parameters that minimize the cost function. Fan performance is characterized by fan curves consisting of the pressure and power as a function of the air flow rate supplied by the fan. A certain fan will generally perform better under a specific range of operating conditions. Therefore, the selection of an optimal fan depends directly on the operating conditions. In that context, it was necessary to formulate an objective function that incorporates the operating conditions, such as airflow rate, pressure and/or power, and uses the fan curves as the input information. The methodology implemented in the PAX design toolbox is depicted in Figure 8 below. Figure 8: Implementation of an Objective Function Applied to Cooling Fans 215 ACEEE Summer Study on Energy Efficiency in Industry 6-7

The second challenge was to select and quantify the parameters used for the fan design tool. PAX selected 25 initial parameters, some of which are shown in Figure 9 below. Figure 9: Fan Top View with Parameters Labeled The third step was to generate fan curves at various diameters and motor speeds using the existing database and scaling laws. This created a master database of fan curves that can be used to compute an objective function. The next step was to select an operating point along the fan curve (pressure and flow) for which the optimization will be performed. Then, each fan curve is analyzed using the following cost function equation,, ( ) (, ) =,, h where FC(X) represents the fan curve for a specific set of parameter X. Using this parameterized fan model, methodology, and process, PAX developed a functioning Fan Parameter Optimizer. Using MATLAB coding and visualization software, it was used in the development of the high efficiency PAX server fan, in combination with CFD and prototype testing. PAX Fan Design Process In order to utilize the PAX fan parameter optimizer described in the previous section, PAX needed a large database of fan samples that were diverse in their parameter combinations to provide insight over the largest range. One of the methods used to create a random sampling of parameter combinations was the Orthogonal Method. Once these designs are created in computer aided design (CAD) software, the fan performance curves must be generated so that the optimizer can evaluate a cost function correlating the parameters to how well the fan performs. Each of the fan designs was generated in CAD, and a rapid prototype was generated using the outside vendor. The fan was then tested in-house using PAX s flowmeter and dynamometer. Once the parameter combinations were established, the CAD files generated and prototyped, and all the testing completed, the PAX parameter optimizer helped PAX analyze their results. With each design iteration, PAX studied the parameter values of the most promising designs, and narrowed its focus to a subset of geometric factors that led to further improvements in design. PAX developed a parameter set and fan design, shown below in Figure 1, that it felt confident would meet the project goal of 15% power reduction in the Boxster chassis. Figures 11 6-8 215 ACEEE Summer Study on Energy Efficiency in Industry

and 12 below show data generated using prototype materials and run on PAX s dynamometer. Compared with the Nidec fan, the PAX design predicts a much higher output at the operating point while using less power. When run slower to just match the cooling capability of the competitor Nidec fan, this initial estimate predicts that the PAX V1 fan design will produce about a 35% drop in power usage compared to the best-in-class Nidec fan currently shipping in the unit. Figure 1: PAX V1 Fan Blade & Frame in CAD & Prototype Airflow Performance for PAX v. Nidec for Boxster (5rpm) 1.2 NidecUF 5rpm Static Pressure [inwg] 1.8.6.4 Boxster System Resistance PAX V1 5rpm PAX V1 42rpm.2 5 1 15 2 25 Figure 11: Airflow/Pressure Data for Final PAX V1 Design 215 ACEEE Summer Study on Energy Efficiency in Industry 6-9

Power Draw for PAX v. Nidec for Boxster (5rpm) 3 25 Shaft Power [W] 2 15 1 NidecUF 5rpm 5 PAX V1 5rpm PAX Pre-production Prototypes 5 1 15 2 25 Figure 12: Airflow/Pressure & Power Data for Final PAX V1 Design Following the design phase, PAX created a more manufacturing-ready version of the PAX prototype on a Nidec motor for testing in the Boxster chassis at Cisco. The samples to be tested by Cisco needed to have all of the same outer and mounting dimensions as the conventional fans. More importantly, they needed to interface with the server s existing internal controller and adjust in speed in an analogous manner to the conventional fans. It was determined that the best way to accomplish this was to use the motor from a Nidec model number T12E5BS2M7-7 fan currently being used in the server, and assemble it to the PAX fan and housing design. A sample set of the Nidec motors was obtained, isolated from their initial fans and frames, and verified for performance. These motors were then assembled into rapid prototypes of the PAX fan and frame design created from the optimized parameters. Because of the high rotational speeds at which these samples would be tested, it was necessary to have the functional samples balanced. The assembled samples were sent to an outside vendor that measured the imbalance of each sample while powering the fan, and added small epoxy masses in the inner hub in order to reduce the imbalance. Performance of the samples was verified at the PAX lab and corresponded well to the initial dynamometer results shown in the prior section. Comparative Power Consumption Monitoring PAX V1 42rpm All of the following test results were generated at the Cisco Test Facility in San Jose, California by Cisco engineers with the assistance of PAX engineers. The procedure followed was in accordance with AMCA 21 standards. The tests measured the performance from a 12-sample installation of three different 12x38mm fans: 1. The PAX V1 Pre-Production Samples (as shown in Figure 13) 2. The Delta Electronics Model #AFC1248DE (currently ships in unit) 3. The Nidec Model #T12E5BS2M7-7 (currently ships in unit) 6-1 215 ACEEE Summer Study on Energy Efficiency in Industry

Figure 13: Upstream & Downstream Views of PAX Pre-Production Samples Boxster Chassis Figure 14 below shows the 12-fan airflow output (proportional to cooling) measured from the Boxster chassis across the x-axis, and the power draw necessary to create that amount of airflow along the y-axis for each fan set. The PAX fans are shown in blue, the Nidec fans are in red, and the Delta fans are in green. The lower end of the curves represent the lowest duty cycle tested of 2%. The upper right-hand side of the curve represents the high duty cycle of 1%. In order to examine equal cooling, one can draw a vertical line through the graph showing equal airflow output, and then look to the left axis to see how much power is used by each fan set. Throughout the entire duty cycle, the PAX fans use significantly less power than both the Nidec and Delta fans for equal cooling. Two example points are highlighted in Figure 14. At a low duty cycle, with about 85CFM of cooling, the PAX prototypes use 41% less power than the Nidec fans and 46% less power than the Delta fans. At the high duty cycle with about 17CFM of cooling, the PAX prototypes use 37% less power than the Nidec fans and 46% less power than the Delta fans. 8 Graph5: Power Draw v. Airflow (5V with PWM) At equal cooling of ~17CFM, PAX uses 37% less power than the Nidecs and 46% less power than the Deltas 7 6 PAX V1 Nidec Fans Power Draw [W] 5 4 3 2 At equal cooling of ~85CFM, PAX uses 41% less power than the Nidecs and 46% less power than the Deltas Delta Fans 1 2 4 6 8 1 12 14 16 18 2 Figure 14: Airflow/Power Comparison for PAX & Competitors Installed in Server Figure 15 shows the same airflow output but graphs it against the total sound power level generated by each fan set in the Boxster chassis. The same low and high duty cycle comparison 215 ACEEE Summer Study on Energy Efficiency in Industry 6-11

examples are highlighted, and this graph can be analyzed in a similar manner, by drawing a vertical line for equal cooling and comparing each fan type s sound power level. At the lower duty cycle point, the PAX prototypes are 2.8dB quieter than both the Nidec and Delta fans for equal cooling. At the higher duty cycle point, the PAX prototypes are about 1dB quieter than the Nidec and Delta fans for equal cooling. Although this is a small drop in noise, the PAX prototypes are never louder than the competitor fans throughout the duty cycle, while greatly reducing the power consumption. 1 Graph6: Sound Power Level v. Airflow (5V with PWM) 9 8 PWL Leq [db] 7 6 PAX V1 Nidec Fans Delta Fans 5 4 2 4 6 8 1 12 14 16 18 2 Figure 15: Airflow/Sound Comparison for PAX & Competitors Installed in Server Conclusion With help provided by a grant from the California Energy Commission, PAX had a goal of demonstrating at least a 15% drop in power draw for matched output in a server, as tested by an outside party. PAX greatly surpassed this goal and designed a fan that produced a 35-45% power drop in the selected server chassis compared to the current best-in-class fans, as specified and tested by Cisco and Jabil. The PAX design offered an additional noise benefit as well. The twelve fans targeted used about 7W of power at full duty cycle. The PAX fans use less than 4W. This power savings only represents one 9-slot chassis. A typical data farm would have hundreds or thousands of these chassis. PAX fans are the same cost to manufacture and fit into existing architecture. Switching to PAX fans in servers can have a significant reduction in wasted energy, greatly reducing operational cost and greenhouse gas emissions. References Glanz, J. "Power, Pollution and the Internet, New York Times, September 23, 212: A1. Koomey, J. 211. Growth in Data Center Electricity Use 25 to 21. Oakland, CA: Analytics Press. 6-12 215 ACEEE Summer Study on Energy Efficiency in Industry