Operating Instructions. Room temperature controller



Similar documents
Operating instructions. RCD flat 4-fold, 6-fold

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

OPERATING INSTRUCTIONS

Drayton Digistat +2RF/+3RF

HERZ-Thermal Actuators

ACS-30-EU-EMDR-10-MOD

3x cinch/s-video socket Order no.: xx. USB/3.5 mm audio socket Order no.: xx. VGA socket Order no.: xx

LUCCI AIRFUSION QUEST II CEILING FAN

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Installation Guide. DEVIreg 530. Electronic Thermostat.

Meaco 30L and Meaco 40L dehumidifier instruction manual

Product and functional description

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

J TB/TW Temperature limiter, temperature monitor

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

INFRARED QUARTZ WALL HEATER

Product and Application Description

Elektromotoren und Gerätebau Barleben GmbH

COLOR VIDEO DOOR PHONE CDV-71BE/D

5W LED Energy Saver PIR Bulkhead

Elektromotoren und Gerätebau Barleben GmbH

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Mounting and operating instructions. Surface-mounted hands-free feature home station

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

How To Use A Power Supply On A Powerline 2.2 (Ai)

Cable Plug acc. to DIN EN , Form A

3 IN 1 BATHROOM HEATER

How To Read A Pipe From A Sensor

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

id led 4" square housing FL44

1 Safety instructions. 2 Device components. Facility Pilot Server. Art. No. : FAPV-SERVER-REG Art. No. : FAPVSERVERREGGB. Operating instructions

RY2 miniature industrial relays

MB-Accumulator Operator's Manual

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Installation, operation and maintenance manual TX 35A

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Operating Instructions Bedienungsanleitung Mode d emploi

DALI RC BASIC SO. Control unit Operating instructions

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Triac Printed Circuit Board Replacement

Transmitter Actuator 230V wave UP 560. Operation

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Description. Dimensions. Features. precision works better

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716

LED Lighting technology. Orientation with system

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

2013 Wireless Video Intercom INSTALLATION GUIDE

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

MINI MCR-SL-R-UI(-SP)

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Rousseau 10. User Guide

16/32 Channel 1U Rack Mount CCTV Power Supply

id led square housing FL44

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

P03/3-Modbus and P03/3-Mod bus-gps

WB/WBS 3, 4, 5, 7, 8, 11, 14, 30

8146/5 Series Breaker Panelboards

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Installation and Operating Manual p. 23. Radio push button 2 channel: HM-PB-2-WM55-2

Nest Learning Thermostat Installation Guide. Installation step-by-step

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

RE-3 : SOLID TOP RANGE RANGE TOP ONLY

V94 BULK TAPE DEGAUSSER

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

RM4TG20 three-phase network control relay RM4-T - range V

User Manual. Video Doorphone CDV-1020AQ

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MOUNTING AND OPERATING INSTRUCTIONS

Heat Pump Training System

RRV934. Multi-controller. Synco living

Operating Instructions Center plate for Timer Thermostat/ Insert

INSTALLATION & USER INSTRUCTIONS

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

REDWALL-V adjustment procedures guide

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Transcription:

Operating Instructions 1. Area of application The room temperature controller is used to regulate the temperature in closed rooms such as flats, schools, function suites, workshops, etc. Safety instructions Electrical equipment may only be installed and fitted by qualified electricians while observing the current accident prevention regulations. A relative air humidity of max. 95% may not be exceeded. Avoid any moisture condensation. Non-observance of the safety warnings or installation instructions may damage the device, cause a fire or other hazards. 2. Installation Notes: Mount the room temperature controller on an internal wall opposite the heat source if possible. Do not mount the room temperature controller on outside walls. Avoid draughts from windows and doors. Ensure that the normal air circulation in the room reaches the controller without any obstacles. External heat sources influence the accuracy of the controller. Avoid direct sunlight and do not place heat-emitting devices in the vicinity of the room temperature controller (heaters, lamps, etc.). Dimmers also generate heat. If a controller is installed in a common switch frame with a dimmer, the distance between them should be as great as possible. When arranging them vertically, the controller must be installed underneath the dimmer. Mounting height: approx. 1.5 m above the floor. Mounted in a switch box in accordance with DIN 49 073. Stand: Sep-11 24091002

3. Connection 1. Carry out the electrical connection according to the respective wiring diagram (Fig. (2) or Fig. (3). Note: Ensure that the neutral conductor N is connected to terminal N. Considerable fluctuations in temperature may otherwise occur. Conductor cross-section: 1 to 2.5 mm2 solid conductor. Symbols used in the wiring diagram: L = L conductor N = N- conductor = Connection for clock signal to reduce temperature = Heating = Cooling RF = Resistor for thermal feedback TA = Resistor for night reduction of room temperature 2. Clip the rocker (A in ) on the switch in the flush insert. 3. Place the center plate together with the frame on the flush insert. The center plate must snap in place in the top left of the housing base. 4. Tighten the screw (B). 5. Clip on the setting knob (C). 2

Fig. 2 Fig. 2 4. Technical data TR 231 U TR 241 U Switching principle 1-pole break 1-pole break contact+on/off contact+on/off switch switch Temperature range 5... 30 C 5... 30 C Nominal voltage AC 230 V ~, 50/60 Hz AC 24 V ~ Nominal current* 10 (4) A 10 (4) A Differential of functioning temperature approx. 0.5 K approx. 0.5 K Temperature reduction approx. 4 K approx. 4 K * The value in brackets indicates the inductive load at a cos φ of 0.6. Subject to change without further notice. 3

Fig. 3 Fig. 3 5. Technical data TR 236 U TR 246 U Switching principle 1-pole change 1-pole changeover contact over contact without switch without switch Temperature range 5 30 C 5... 30 C Nominal voltage AC 230 V ~, 50/60 Hz AC 24 V ~ Nominal current* Heating 10 (4) A 10 (4) A Cooling 5 (2) A 5 (2) A Differential of functioning approx. 0.5 K approx. 0.5 K temperature * The value in brackets indicates the inductive load at a cos φ of 0.6. Subject to change without further notice. 4

6. Restricting the temperature setting range The temperature controller is set ex works to the maximum setting range of 5 C to 30 C. See. Two adjustment rings are located in the setting knob. You can use these rings to restrict the temperature setting range required e.g. between 8 C and 23 C. Procedure: 1. Select the temperature limits. Example: max. 23 C, min 8 C 2. Note! First position the setting knob roughly in the centre of the required setting range. Example: The centre point between 8 C and 23 C is approximately 15 C. 3. Now remove the setting knob. 4. Set the red locating ring to the max. temperature limit. Example: 23 C Rotate anti-clockwise. The numbers on the outer dial apply! Insert the tip of a pen in the hole and turn the red ring to the left until it reaches 23 C (max. scale). See. 5. Set the blue locating ring to the min. temperature limit. Example: 8 C Rotate clockwise. The numbers on the inner dial apply. Insert the tip of a pen in the hole and turn the blue ring to the right until it reaches 8 C (min. scale). See 5

6. Clip on the setting knob. The pointer must be roughly in the centre of the new setting range (see point 2). Example: approx. 15 C Scale for setting the temperature with dials 1 = approx. 05 C 2 = approx. 10 C 3 = approx. 15 C 4 = approx. 20 C 5 = approx. 25 C 6 = approx. 30 C 7. Symbols Off I On 8. Guarantee Our products are under guarantee within the scope of the statutory provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: ALBRECHT JUNG GMBH & CO. KG Service-Center Kupferstr. 17-19 D-44532 Lünen Service-Line: 0 23 55. 80 65 51 Telefax: 0 23 55. 80 61 89 E-Mail: mail.vki@jung.de General equipment Service-Line: 0 23 55. 80 65 55 Telefax: 0 23 55. 80 62 55 E-Mail: mail.vkm@jung.de KNX equipment Service-Line: 0 23 55. 80 65 56 Telefax: 0 23 55. 80 62 55 E-Mail: mail.vkm@jung.de 6