49 Series - Relay interface modules 8-10 - 16 A. Features



Similar documents
pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

48 SERIES Relay interface modules 10 A

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

40 Series - Miniature PCB/Plug-in relays A. Features

38 Series - Relay interface modules A

38 Series - Relay interface modules A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

60 Series - General purpose relays 6-10 A. Features

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules

80 Series - Modular timers 16 A. Features

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

80 Series - Modular timers 16 A. Features

RY2 miniature industrial relays

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

13 SERIES. Electronic step relays A

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Relays, Timers, Interface Modules, Sockets and Accessories Catalogue. S.p.A. ISO 9001 ISO The power in relays and timers since 1954

Pluggable interface relays CR-P Pcb relays

Three-phase monitoring relay CM-PFE

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

12 Series - Time switches 16 A. Features

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Thermistor motor protection

Electronic overload relay EF19 and EF45

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

General Purpose Relays Accessories. Accessories Miniature Relay PT

Safety technique. Emergency stop module BO 5988 safemaster

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic overload relay EF65, EF96 and EF146

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

RM4TG20 three-phase network control relay RM4-T - range V

Goodsky Technical Data. Contact Details

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Description Part-No. Type PU. Nominal voltage DC12V Relais-SNR 12V 1W 20 DC 24 V Relais-SNR 24V 1W 20

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet _en_02. 1 Description

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Relays and Timers Specifications Bulletin Number 700

Redundancy Module QUINT-DIODE/40

MULTIFUNCTION TIME RELAY CRM-93H

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Relés e Contatores de Estado Sólido SIRIUS

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

AZ420 MINIATURE GENERAL PURPOSE RELAY

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

SPST-NO SPDT DPST-NO DPDT

Catalog. Modular DIN rail components Installation contactors

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Contact expander modules

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Technical catalogue. Modular DIN rail components Installation contactors

SKR - industry relay

3-phase, bidirectional energy meter

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

15 Series - Electronic step relay and dimmer. Features SERIE

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Type: DILM32 10(24V50HZ) Article No.:

Contact expansion modules

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

General technical information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Type: DILM50(230V50HZ,240V60HZ) Article No.:

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

1 POLE - 8A Medium Load Control

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

Control Devices Catalogue. Control Devices. Preferred and Standard Products

The complete range of consumer switchboards and switchgear

E-STOP relays, safety gate monitors

Plug-in relays Mini ISO relays

LAUBE TECHNOLOGY DRY REED RELAYS

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Solid-State Timer H3G

1a/1c 5A/10A small power relays

Transcription:

Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole 8 A (screwless terminal) 15.5 mm wide Ideal interface for PLC and electronic systems AC coils & DC coils Instant ejection of relay using plastic retaining clip Supply status indication and coil suppression module Identification labels 49.31-50x0 1 pole, 10 A AgNi + Au (5 µm) contact material 49.52/72-50x0 2 pole, 8 A AgNi + Au (5 µm) contact material 49.31-50x0 / 49.52 49.72-50x0 For outline drawing see page 8 Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220V A Minimum switching load mw (V/mA) Standard contact material Coil specification Nominal voltage (U N ) V AC (50/60 Hz) V DC Rated power /sens.dc (50 Hz)/W/W Operating range AC DC/sensitiv DC Holding voltage Must drop-out voltage Mechanical life cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals relay (according to type) ** By external parallel connection of the contacts the values within [1 (0.1/1)] can be acheived. 1 CO (SPDT) 2 CO (DPDT) 10/20 8/15 250/400 250/250 2,500 2,000 500 400 0.37 0.3 10/0.3/0.12 8/0.3/0.12 50 (5/2) 50 (5/2) - [1 (0.1/1)]* AgNi + Au (5 µm) AgNi + Au (5 µm) 12-24 - 110-120 - 230 12-24 - 110-120 - 230 12-24 - 125 12-24 - 125 1.2/0.65/0.5 1.2/0.65/0.5 (0.73 1.5)U N /(0.73 1.7)U N (0.73 1.5)U N /(0.73 1.7)U N 0.8 U N /0.4 U N 0.8 U N /0.4 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 10 10 6 /20 10 6 10 10 6 /20 10 6 150 10 3 150 10 3 7/4 (AC) - 12/12 (DC) 7/4 (AC) - 12/12 (DC) 6 (8 mm) 6 (8 mm) 1,000 1,000 IP 20 IP 20 1

Features 1 & 2 Pole relay interface modules AgNi contacts for medium duty switching 49.31-00x0-1 Pole 10 A (screw terminal) 49.52-00x0-2 Pole 8 A (screw terminal) 49.72-00x0-2 Pole 8 A (screwless terminal) 15.5 mm wide Ideal interface for PLC and electronic systems AC coils & DC coils Instant ejection of relay using plastic retaining clip Supply status indication and coil suppression module Identification labels 49.31-00x0 1 pole, 10 A AgNi contact material 49.52/72-00x0 2 pole, 8 A AgNi contact material 49.31-00x0 / 49.52 49.72-00x0 For outline drawing see page 8 Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220V A Minimum switching load mw (V/mA) Standard contact material Coil specification Nominal voltage (U N ) V AC (50/60 Hz) V DC Rated power /sens.dc (50 Hz)/W/W Operating range AC DC/sensitiv DC Holding voltage Must drop-out voltage Mechanical life cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals relay (according to type) 1 CO (SPDT) 2 CO (DPDT) 10/20 8/15 250/400 250/250 2,500 2,000 500 400 0.37 0,3 10/0.3/0.12 8/0.3/0.12 300 (5/5) 300 (5/5) AgNi AgNi 12-24 - 110-120 - 230 12-24 - 110-120 - 230 12-24 - 125 12-24 - 125 1.2/0.65/0.5 1.2/0.65/0.5 (0.73 1.5)U N /( 0.73 1.7)U N (0.73 1.5)U N /( 0.73 1.7)U N 0.8 U N /0.4 U N 0.8 U N /0.4 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 10 10 6 /20 10 6 10 10 6 /20 10 6 200 10 3 150 10 3 7/4 (AC) - 12/12 (DC) 7/4 (AC) - 12/12 (DC) 6 (8 mm) 6 (8 mm) 1,000 1,000 IP 20 IP 20 2

Features 1 & 2 Pole relay interface modules AgCdO contacts for heavy duty switching 49.31-20x0-1 Pole 10 A (screw terminal) 49.52-20x0-2 Pole 8 A (screw terminal) 49.72-20x0-2 Pole 8 A (screwless terminal) 15.5 mm wide Ideal interface for PLC and electronic systems AC coils & DC coils Instant ejection of relay using plastic retaining clip Supply status indication and coil suppression module Identification labels 49.31-20x0 1 pole, 10 A AgCdO contact material 49.52/72-20x0 2 pole, 8 A AgCdO contact material 49.31-20x0 / 49.52 49.72-20x0 For outline drawing see page 8 Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220V A Minimum switching load mw (V/mA) Standard contact material Coil specification Nominal voltage (U N ) V AC (50/60 Hz) V DC Rated power /sens.dc (50 Hz)/W/W Operating range AC DC/sensitiv DC Holding voltage Must drop-out voltage Mechanical life cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals relay (according to type) 1 CO (SPDT) 2 CO (DPDT) 10/20 8/15 250/400 250/250 2,500 2,000 500 400 0.37 0.3 10/0.3/0.12 8/0.3/0.12 500 (10/5) 500 (10/5) AgCdO AgCdO 12-24 - 110-120 - 230 12-24 - 110-120 - 230 12-24 - 125 12-24 - 125 1.2/0.65/0.5 1.2/0.65/0.5 (0.73 1.5)U N /(0.73 1.75)U N (0.73 1.5)U N /(0.73 1.75)U N 0.8 U N /0.4 U N 0.8 U N /0.4 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 10 10 6 /20 10 6 10 10 6 /20 10 6 200 10 3 150 10 3 7/4 (AC) - 12/12 (DC) 7/4 (AC) - 12/12 (DC) 6 (8 mm) 6 (8 mm) 1,000 1,000 IP 20 IP 20 3

Features 1 Pole relay interface module AgCdO contacts for heavy duty switching 49.61-20x0-1 Pole 16 A (screw terminal) 49.81-20x0-1 Pole 16 A (screwless terminal) AgSnO 2 contacts for heavy duty, high current inrush switching 49.61-40x0-1 Pole 16 A (screw terminal) 49.81-40x0-1 Pole 16 A (screwless terminal) 15.5 mm wide Ideal interface for PLC and electronic systems AC coils & DC coils Instant ejection of relay using plastic retaining clip Supply status indication and coil suppression module Identification labels 49.61/81-20x0 1 pole, 16 A* AgCdO contact material 49.61/81-40x0 1 pole, 16 A* AgSnO 2 contact material 49.61 49.81-20x0/40x0 For outline drawing see page 8 Contact configuration Rated current/maximum peak current A Rated voltage/maximum switching voltage V AC Rated load AC1 Rated load AC15 (230 V AC) Single phase motor rating (230 V AC) kw Breaking capacity DC1: 30/110/220V A Minimum switching load mw (V/mA) Standard contact material Coil specification Nominal voltage (U N ) V AC (50/60 Hz) V DC Rated power /sens.dc (50 Hz)/W/W Operating range AC DC/sensitiv DC Holding voltage Must drop-out voltage Mechanical life cycles Electrical life at rated load AC1 cycles Operate/release time ms Insulation between coil and contacts (1.2/50 µs) kv Dielectric strength between open contacts V AC Ambient temperature range C Protection category Approvals relay (according to type) * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). * For currents >10 A, contact terminals must be connected in parallel (21 with 11, 24 with 14, 22 with 12). 1 CO (SPDT) 1 CO (SPDT) 16*/30 16*/100 (5 ms) 250/400 250/400 4,000 4,000 750 750 0.55 0.55 16/0.3/0.12 16/0.3/0.12 500 (5/5) 1,000 (10/10) AgCdO AgSnO 2 12-24 - 110-120 - 230 12-24 - 110-120 - 230 12-24 - 125 12-24 - 125 1.2/0.65/0.5 1.2/0.65/0.5 (0.73 1.5)U N /(0.8 1.5)U N (0.73 1.5)U N /(0.8 1.5)U N 0.8 U N /0.4 U N 0.8 U N /0.4 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 10 10 6 /20 10 6 10 10 6 /20 10 6 100 10 3 100 10 3 7/4 (AC) - 12/12 (DC) 7/4 (AC) - 12/12 (DC) 6 (8 mm) 6 (8 mm) 1,000 1,000 IP 20 IP 20 4

Ordering information Example: 49 series, 35 mm rail (EN 60715) mount screw terminal relay interface module, 2 CO (DPDT) 8 A contacts, 24 V sensitive DC coil, green LED + diode (polarity +A1), 99.80 coil indication. 4 9 A B C D. 5 2. 7. 0 2 4. 0 0 5 0 Series Type 3, 5, 6 = 35 mm rail (EN 60715) mount, screw terminal 7, 8 = 35 mm rail (EN 60715) mount, screwless terminal No. of poles 1 = 1 pole for 49.31, 10 A 49.61, 49.81, 16 A 2 = 2 pole for 49.52, 49.72, 8 A Coil version 7 = Sensitive DC (500 mw) 8 = AC (50/60 Hz) 9 = DC (650 mw) Coil voltage See coil specifications A: Contact material 0 = Standard AgNi for 49.31/52/72, AgCdO for 49.61/81 2 = AgCdO for 49.31/52/72 4 = AgSnO 2 for 49.61/81 only 5 = AgNi + Au (5 µm) not for 49.61/81 B: Contact circuit 0 = CO (npdt) D: Special versions 0 = Standard C: Options 5 = Standard for DC: green LED + diode (polarity +A1) 6 = Standard for AC: green LED + Varistor Selecting features and options: only combinations in the same row are possible. Preferred selections for best availability are shown in bold. Type Coil version A B C D 49.31/52/72 AC 0-2 - 5 0 6 0 49.31/52/72 DC - sens. DC 0-2 - 5 0 5 0 49.61/81 AC 0-4 0 6 0 49.61/81 DC - sens. DC 0-4 0 5 0 Insulation 49.31/61 49.52/72 49.31/61/81 Insulation according to EN 61810-1 insulation rated voltage V 250 250 400 rated impulse withstand voltage kv 4 4 4 pollution degree 3 2 2 overvoltage category III III III Insulation between coil and contacts (1.2/50 µs) kv 6 (8 mm) Dielectric strength between open contacts V AC 1,000 Dielectric strength between adjacent contacts V AC 2,000 (49.52/72) Conducted disturbance immunity Burst (5...50)ns, 5 khz, on A1 - A2 EN 61000-4-4 level 4 (4 kv) Surge (1.2/50 µs) on A1 - A2 (differential mode) EN 61000-4-5 level 3 (2 kv) Other data Bounce time: NO/NC ms 2/5 Vibration resistance (5 55)Hz: NO/NC g 10/4 (for 1 pole) 15/3 (for 2 pole) Power lost to the environment without contact current W 0.7 with rated current W 1.2 (49.31/61/81) 1.3 (49.52/72) Wire strip length mm 8 Screw torque Nm 0.5 Max. wire size solid cable stranded cable solid cable stranded cable mm 2 1x6 / 2x2.5 1x4 / 2x2.5 2x(0.2...1.5) 2x(0.2...1.5) AWG 1x10 / 2x14 1x12 / 2x14 2x(24...18) 2x(24...18) 5

F 49 - Electrical life (AC) v contact current Types 49.31/61/81 F 49 - Electrical life (AC) v contact current Types 49.52/72 Cycles Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 Cycles Resistive load - cosϕ = 1 Inductive load - cosϕ = 0.4 limit for 49.31 H 49 - Maximum DC1 breaking capacity Types 49.31/52/61/72/81 DC breaking current (A) 49.61/81 current limit 49.31 current limit 49.52/72 current limit single contact 49.52/72-2 contacts in series DC voltage (V) When switching a resistive load (DC1) having voltage and current values under the curve, an electrical life of 100 10 3 can be expected. In the case of DC13 loads, the connection of a diode in parallel with the load will permit a similar electrical life as for a DC1 load. Note: the release time for the load will be increased. 6

Coil specifications DC coil data (0.5 W sensitive) Nominal Coil Operating range Rated coil voltage code consumption U N U min* U max** I at U N V V V ma 12 7.012 8.8 21 41 24 7.024 17.5 42 22.2 125 7.125 91.2 219 4 *U min = 0.8 U N for 49.61 and 49.81 **U max = 1.5 U N for 49.61 and 49.81 AC coil data Nominal Coil Operating range Rated coil voltage code consumption U N U min U max I at U N (50Hz) V V V ma 12 8.012 9.6 13.2 90.5 24 8.024 19.2 26.4 46 110 8.110 88 121 10.1 120 8.120 96 132 11.8 230 8.230 184 253 7.0 DC coil data (0.65 W) Nominal Coil Operating range Rated coil voltage code consumption U N U min U max I at U N V V V ma 12 9.012 8.8 18 56 24 9.024 17.5 36 29 125 9.125 91.2 188 6 R 49 - DC coil operating range v ambient temperature Standard (650 mw) R 49 - AC coil operating range v ambient temperature 1 1 2 2 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. R 49 - DC coil operating range v ambient temperature Sensitive coil (500 mw) 49.31/52/72 49.61/81 1 49.61/81 49.31/52/72 2 1 - Max. permitted coil voltage. 2 - Min. pick-up voltage with coil at ambient temperature. 7

21 49 Series - Relay interface modules 8-10 - 16 A Combinations Code Type of socket Type of relay Module Retaining clip 49.31 95.93.3 40.31 99.80 095.91.3 49.52 95.95.3 40.52 99.80 095.91.3 49.61 95.95.3 40.61 99.80 095.91.3 49.72 95.55.3 40.52 99.80 095.91.3 49.81 95.55.3 40.61 99.80 095.91.3 Outline drawing 73.7 15.5 15.5 75 64.8 46.8 28.8 COM 11 24.6 4 4 81.9 78.6 81.9 78.6 95.6 24 NO 14 22 NC 12 30.3 34.7 30.6 A2 COIL A1 29.8 33.8 15.8 22.6 32.5 49.31 49.52 49.61 49.31-50x0 / 49.31-00x0 / 49.31-20x0 / 49.52 / 49.61 49.72 49.81 49.72-50x0 / 49.72-00x0 / 49.72-20x0 49.81-20x0 / 49.81-40x0 Accessories 8-way jumper link for screw terminal versions 095.08 (blue) 095.08.0 (black) Rated values 10 A - 250 V 095.08 Sheet of marker tags, plastic, 72 tags, 6x12 mm 060.72 060.72 Packaging codes How to code and identify retaining clip and packaging options for sockets. Example: 4 9. 5 2. 7. 0 2 4. 0 0 5 0 S P A A B Standard packaging Blister packaging 8 SP Plastic retaining clip