PSR The compact range Description



Similar documents
Phone: Fax: Web: info@clrwtr.com

Softstarters. Index. 5 - Softstarters. Phone: Fax: Web: info@clrwtr.com.

Softstarters Type PSR

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB. Latest updated not printed, only in PDF-format

Phone: Fax: Web: info@clrwtr.com

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Panorama. Softstarters The complete range

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Installation and Maintenance manual. Softstarters PST / PSTB

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Catalog. Modular DIN rail components Installation contactors

Mykstartere. Type PSS Type PST/PSTB - New range. Katalog 1SEC132001C2101, Juli SFC132016F0201

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Softstarters. Type PST30...PSTB1050 Installation and Commissioning Manual. Manual 1SFC132003M0201 June Fault. Power on Protection

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Technical catalogue. Modular DIN rail components Installation contactors

Three-phase monitoring relay CM-PFE

Number 1 in efficiency

Manual motor starter MS116

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Softstarters Type PSE18...PSE370 Installation and commissioning manual

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

40.3. Control Relays and Timers

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

US Catalog. Softstarters Type PSTX and PSTB

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

D-Line Contactors, Overload Relays and Accessories

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Type: DILM32 10(24V50HZ) Article No.:

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Electric Rotary Actuator - On/Off or programmable control actuator

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Quick Connect. quick - simple - efficient.

48 SERIES Relay interface modules 10 A

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Manual Motor Starter MS 116 up to 16 A Technical Data

49 Series - Relay interface modules A. Features

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

SMC -3 Specifications

SOFTSTARTER HANDBOOK

Plug and Socket Devices CES 63 A Series 8579

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Low Voltage Products. Switches Automatic Transfer Switches

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

R.C.C.B. s two-pole LEXIC

Rotary Disconnect Switch Specifications

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Type: DILM9 10(24VDC) Article No.:

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

RM4TG20 three-phase network control relay RM4-T - range V

Technicaldata General

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Vario-Series Accessories

Analog signal converters CC-E I/I Current / current isolators

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Maximum Demand Control

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

3753 en /b VE/B - VE/RG Va V riable speed drives

Pluggable interface relays CR-P Pcb relays

Relés e Contatores de Estado Sólido SIRIUS

E-STOP relays, safety gate monitors

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Products and solutions for lifting systems

MOTOR CONTROL IS OUR NATURE

T7079A,B Solid State Remote Temperature Controllers

Thermistor motor protection

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

Speed Control Relays SX2

Specifying a Variable Frequency Drive s

HERZ-Thermal Actuators

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Circuit Breakers. Next Generation of Protection Capabilities

Transcription:

Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides a far more compact starting solution than for example a star delta starter. Flexible mounting PSR softstarters from 3 to 45 A are possible to mount on a din rail, ensuring quick and easy mounting. Naturally, all sizes can be screw mounted. Few settings The set-up of the PSR is easily done and confirmed using the three clearly marked potentiometers on the front. Product description Wide rated operational voltage 208 600 V Rated control supply voltage 24 V DC or 100 240 V AC Rated operational current 3 105 A Wide ambient temperature range, -25 to +60 ºC (-13 to 140 ºF) Built-in by-pass on all sizes, saving energy and reducing installation time Potentiometer settings Run signal relay on all devices TOR signal relay on PSR25 PSR105 Modbus, Devicenet or CANopen DIN rail mounting on PSR3 PSR45 Screw mounting on all sizes Connection kits for easy connection with ABB manual motor starters Sophisticated algorithm eliminating the DC-component and thereby providing excellent starting performance. Built-in by-pass for energy saving The built-in by-pass on all sizes does not only save energy; it will also ensure the most compact ABB softstarter design and reduce the installation time. Suitable for stopping pumps Even without using torque control, the PSR range is designed to reduce water hammering and will allow a superior stop compared to the direct stop resulting from a star delta starter or a DOL starter. See the special designed stop ramp with step down voltage below. System concept with manual motor starters All PSR softstarter sizes can easily be connected to the corresponding manual motor starters from ABB, using the special designed connection kits. This will both make the mounting and the connection easier and will provide a very compact starting solution containing short circuit and thermal protection, isolation function and softstarter - everything that you need. Settings 2 Step down 1 2 3 Start = 1... 20 sec Stop = 0... 20 sec - including the step down voltage. Step down = 2% reduction for each second increased stop ramp Stop ramp 10 sec -> Step down 80% (20% reduction) U ini = 40... 70% results in End voltage = 30... 60% 1 2 3 3 U ini 3 Uend 1 Start 2 Stop 8 Softstarters

Overview PSR3... PSR16 PSR25... PSR30 PSR37... PSR45 PSR60... PSR105 Softstarter Normal start In-line connected PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105 (480 V) hp 2 3 5 7.5 10 15 20 25 30 40 50 60 75 (600 V) hp 2 5 7.5 10 10 20 25 30 40 50 60 75 100 UL/CSA, Max FLA 3.4 6.1 9 11 15.2 24.2 28 34 46.2 59.4 68 80 104 Using manual motor starter, type 1 coordination will be achieved Manual motor starter (5 ka, 600 V, 40 ºC) MS116 MS132 MS450 MS495 Using J fuses, type 1 coordination will be J type fuse protection (85 ka) achieved 175 % rating 5 A 10 A 15 A 15 A 25 A 40 A 45 A 50 A 80 A 100 A 110 A 125 A 175 A Max rating 35 A 35 A 35 A 35 A 35 A 60 A 60 A 90 A 90 A 110 A 125 A 150 A 200 A Minimum enclosure size 1) 254 x 204 x 153 mm / 10 x 8 x 6 in 305 x 254 x 204 mm / 12 x 10 x 8 in 600 x 400 x 210 mm / 24 x 16 x 8 in Fusible disconnect switch for the above J fuses Fusible disconnect switch OS30 OS60 OS100 OS200 Overload protection is used to protect the motor from over heating Thermal overload relay TF42DU TA75DU TA110DU The line contactor is not required for the softstarter itself but often used to open if OL trips Line contactor AF9 AF12 AF16 AF26 AF30 AF50 AF63 AF75 AF95 AF110 Using by-pass will reduce the power loss and allow more starts per hour Bypass contacts Built-in 1) Enclosure that has two latching points minimum. For use in pollution degree 2 environment. Softstarters 9

Ordering details PSR3... PSR105 Rated operational voltage U e, 208-600 V AC Rated control supply voltage, U s, 100-240 V AC 230 V kw 400 V kw 500 V kw 208 V hp 230 V hp 480 V hp 600 V hp UL/CSA Max rated operational current I e A Part number 0.75 1.5 2.2 0.5 0.75 2 2 3.4 PSR3-600-70 0.450 (0.99) 1.5 3 4 1 1.5 3 5 6.1 PSR6-600-70 0.450 (0.99) 2.2 4 4 2 2 5 7.5 9 PSR9-600-70 0.450 (0.99) 3 5.5 5.5 3 3 7.5 10 11 PSR12-600-70 0.450 (0.99) PSR3... PSR16 4 7.5 7.5 3 5 10 10 15.2 PSR16-600-70 0.450 (0.99) 5.5 11 15 7.5 7.5 15 20 24.2 PSR25-600-70 0.650 (1.43) 7.5 15 18.5 7.5 10 20 25 28 PSR30-600-70 0.650 (1.43) 7.5 18.5 22 10 10 25 30 34 PSR37-600-70 1.000 (2.20) 11 22 30 15 15 30 40 46.2 PSR45-600-70 1.000 (2.20) 15 30 37 20 20 40 50 59.4 PSR60-600-70 2.200 (4.85) 22 37 45 20 25 50 60 68 PSR72-600-70 2.270 (5.00) PSR25... PSR30 22 45 55 25 30 60 75 80 PSR85-600-70 2.270 (5.00) 30 55 55 30 40 75 100 104 PSR105-600-70 2.270 (5.00) Rated operational voltage U e, 208-600 V AC Rated control supply voltage, U s, 24 V DC 0.75 1.5 2.2 0.5 0.75 2 2 3.4 PSR3-600-81 0.450 (0.99) 1.5 3 4 1 1.5 3 5 6.1 PSR6-600-81 0.450 (0.99) 2.2 4 4 2 2 5 7.5 9 PSR9-600-81 0.450 (0.99) PSR37... PSR45 3 5.5 5.5 3 3 7.5 10 11 PSR12-600-81 0.450 (0.99) 4 7.5 7.5 3 5 10 10 15.2 PSR16-600-81 0.450 (0.99) 5.5 11 15 7.5 7.5 15 20 24.2 PSR25-600-81 0.650 (1.43) 7.5 15 18.5 7.5 10 20 25 28 PSR30-600-81 0.650 (1.43) 7.5 18.5 22 10 10 25 30 34 PSR37-600-81 1.000 (2.20) 11 22 30 15 15 30 40 46.2 PSR45-600-81 1.000 (2.20) 15 30 37 20 20 40 50 59.4 PSR60-600-81 2.200 (4.85) 22 37 45 20 25 50 60 68 PSR72-600-81 2.270 (5.00) PSR60... PSR105 22 45 55 25 30 60 75 80 PSR85-600-81 2.270 (5.00) 30 55 55 30 40 75 100 104 PSR105-600-81 2.270 (5.00) 10 Softstarters

Accessories Connection kit For softstarter type Part number Pack ing piece 1 piece PSR3...PSR16 with MS116 PSR16-MS116 1 0.030 (0.07) PSR25...PSR30 with MS132 PSR30-MS132 1 0.030 (0.07) PSR16-MS116 PSR30-MS132 PSR37...PSR45 with MS450 PSR45-MS450 1 0.030 (0.07) PSR60...PSR105 with MS495 PSR105-MS495 1 0.050 (0.11) PSR45-MS450 PSR105-MS495 Fan For softstarter type Part number Pack ing piece 1 piece PSR3...PSR45 1 0.010 (0.02) PSR60...PSR105 1 0.013 (0.03) Terminal enlargements PSR-FAN PSR-FAN 60-105 A For softstarter type PSR60...105 Wire range mm2 1x10...50, 2x10...25 Part number Pack ing piece 1 piece PSLW-72 1 0.150 (0.33) PSLW FieldBus plug connection accessory For softstarter type Part number Pack ing piece 1 piece The same accessory for all sizes PS-FBPA 1 0.060 (0.13) ABB Field Bus Plug suitable for all sizes. See page 38-41 PS-FBPA Connection kit Thermal motor overload protection Isolating function Short circuit protection Connection device Softstarter providing excellent start and stop Softstarters 11

Technical data Rated insulation voltage U i 600 V Rated operational voltage U e 208...600 V +10 %/-15 %, 50/60 Hz ±5 % Rated control supply voltage U s 100...240 V AC, 50/60Hz ±5 % or 24 V DC, +10 %/-15 %, Power consumption PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105 Supply circuit at 100-240 V AC 12 VA 10 VA at 24 V DC 5 W Max. Power loss at rated I e PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105 0.7 W 2.9 W 6.5 W 11.5 W 20.5 W 25 W 36 W 5.5 W 8.1 W 3.6 W 5.2 W 7.2 W 6.6 W Starting capacity at I r 4 x Ir for 6 sec. See table on page 13. standard 10 1) with aux. fan 20 1) Service factor 100 % Ambient temperature during operation -25 ºC to + 60 ºC (-13 to 140 ºF) 2) during storage -40 ºC to + 70 ºC (-40 to 158 ºF) Maximum altitude 4000 m (13123 ft) 3) Degree of protection PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 PSR60 PSR72 PSR85 PSR105 main circuit IP20 IP10 control circuit IP20 Connection PSR3-PSR16 PSR25-PSR30 PSR37-PSR45 PSR60-PSR105 main circuit cable area 1 x 2.5mm 2 1 x 2.5-10 mm 2 1 x 6-35 mm 2 1 x 10-95 mm 2 1 x 14 AWG 1 x 12-8 AWG 1 x 8-4 AWG 1 x 6-2/0 AWG tightening torrque 1 Nm - 9 lb.in 2.3 Nm - 20 lb.in 4.0 Nm - 35 lb.in 8.0 Nm - 71 lb.in PSR3-PSR16 PSR25-PSR105 control circuit cable area 1 x 1.5-2.5 mm 2 1 x 1.5-2.5 mm 2 2 x 1.5 mm 2 2 x 1.5 mm 2 1 x 16-14 AWG 1 x 16-14 AWG 2 x 16 AWG 2 x 16 AWG tightening torque 1 Nm - 9 lb.in 0.6 Nm - 5 lb.in Signal relays PSR3-PSR16 PSR25-PSR105 for Run signal Resistive load 240 V AC, 3 A / 24 V DC, 3 A 240 V AC, 3 A / 24 V DC, 3 A AC-15 (Contactor) 240 V AC, 0.5 A / 24 V DC, 0.5 A 240 V AC, 0.5 A / 24 V DC, 0.5 A for Top ramp signal Resistive load - 240 V AC, 3 A / 24 V DC, 3 A AC-15 (Contactor) - 240 V AC, 0.5 A / 24 V DC, 0.5 A LED for On/Ready Green for Run/Top Of Ramp Green Settings Ramp time during start 1-20 sec. Ramp time during stop 0-20 sec. Initial- and End Voltage 40-70% 1) Valid for 50 % on time and 50 % off time. 4 x I e 2) Above 40 ºC (104 ºF) up to max. 60 ºC (140 ºF) reduce the rated current with 0.8 % per ºC (0.44 % per ºF). 3) When used at high altitudes above 1000 meters (3281 ft) up to 4000 meters (13123 ft) you need to derate the rated current using the following formula. [ % of I e = 100 - x - 1000 ] x = actual altitude for the softstarter in meter 150 [ % of I e = 100 - x - 3280 ] x = actual altitude for the softstarter in feet 497 12 Softstarters

Technical data Motor Starts/hour without auxiliary fan Starts/hour with auxiliary fan current I e 10 20 30 40 50 60 80 100 10 20 30 40 50 60 80 100 3 A PSR3 PSR6 PSR3 6 A PSR6 PSR9 PSR6 PSR9 9 A PSR9 PSR12 PSR16 PSR25 PSR9 PSR12 12 A PSR12 PSR16 PSR25 PSR30 PSR12 PSR16 PSR25 16 A PSR16 PSR25 PSR30 PSR37 PSR16 PSR25 PSR30 25 A PSR25 PSR30 PSR37 PSR45 PSR60 PSR25 PSR30 PSR37 PSR45 30 A PSR30 PSR37 PSR45 PSR60 PSR72 PSR30 PSR37 PSR45 37 A PSR37 PSR45 PSR60 PSR72 PSR85 PSR105 PSR37 PSR45 PSR60 45 A PSR45 PSR60 PSR72 PSR85 PSR105 - PSR45 PSR60 PSR72 60 A PSR60 PSR72 PSR85 PSR105 - - PSR60 PSR72 PSR85 PSR105-72 A PSR72 PSR85 PSR105 - - - - PSR72 PSR85 PSR105 - - 85 A PSR85 PSR105 - - - - - PSR85 PSR105 - - - - 105 A PSR105 - - - - - - - PSR105 - - - - - - Data based on an ambient temperature of 40 C (104 ºF), starting current of 4 x I e and ramp time 6 seconds. For more optimized selections, or to use PSR for heavy duty starts, please use the softstarter selection program, ProSoft. Softstarters 13

Dimensions PSR softstarters PSR3 16 PSR37 45 PSR60... 105 PSR25 30 Dimensions in mm (and inches) Softstarters 43

Dimensions PSR softstarters PSR3 16 PSR37 45 PSR60... 105 PSR25 30 Dimensions in mm (and inches) Softstarters 43