Mykstartere. Type PSS Type PST/PSTB - New range. Katalog 1SEC132001C2101, Juli SFC132016F0201
|
|
- Gwenda Goodman
- 7 years ago
- Views:
Transcription
1 Mykstartere Type PSS Type PST/PSTB - New range Ny Katalog 1SEC132001C2101, Juli SFC132016F0201
2 PSS03... PSS25 For normal starts Application The softstarter types PSS03... PSS25 are compact solutions for small motors. It is easy to install and to adjust as access for connections and adjustments is from the front. The unit is for DIN-rail mounting. Description Current ratings 3, 12 and 25 A Main voltage levels 230, 400, and 600 V Control voltage range V AC/DC and V AC Settings for Start ramp, Stop ramp and Initial Voltage For mounting on 35 mm DIN-rail Built-in by-pass contacts Operator panels PSS03 PSS SFT PSS25! SFT PSS03...PSS12 Three potentiometers for: -Start ramp -Stop ramp -Initial voltage Front access for connections Clear markings DIN-rail mounting Integrated by-pass contacts PSS25 LED indications: Power supply on Running mode/by-pass Completed start ramp LED indications: Power supply on Ramping up/down (flashing) Completed start ramp General fault PSS03 PSS12 PSS25 Ordering details V 230 V 400 V 500 V 600 V Rated motor P e P e P e P e current, I e El.nummer kw kw kw kw A Type 1) Order code PSS03-220B 1SFA R PSS12-220B 1SFA R PSS25-220B 1SFA R PSS03-400B 1SFA R PSS12-400B 1SFA R PSS25-400B 1SFA R PSS03-480B 1SFA R PSS12-480B 1SFA R PSS25-480B 1SFA R PSS12-600B 1SFA R PSS25-600B 1SFA R ) Control voltage, U c Type V, AC/DC V, AC 220B B B B ABB
3 PSS18/30... PSS300/515 For normal starts. In-Line PSS18/ / PSS50/ / PSS18/ / PSS85/ / PSS85/ / Ordering details. In-Line V P e P e P e current, I e kw kw kw A Type *) Order code **) PSS18/ SFA R PSS30/ SFA R PSS37/ SFA R PSS44/ SFA R PSS50/ SFA R PSS60/ SFA R PSS72/ SFA R PSS85/ SFA R PSS105/ SFA R PSS142/ SFA R PSS175/ SFA R PSS250/ SFA R PSS300/ SFA R How to select correct size for heavy duty starts See the quick guide on page 6. P e P e P e current, I e kw kw kw A Type *) Order code **) PSS18/ SFA R PSS30/ SFA R PSS37/ SFA R PSS44/ SFA R PSS50/ SFA R PSS60/ SFA R PSS72/ SFA R PSS85/ SFA R PSS105/ SFA R PSS142/ SFA R PSS175/ SFA R PSS250/ SFA R PSS300/ SFA R PSS175/ / PSS175/ / *) Add code letter in Type for: Supply voltage, U c F = V, 50/60 Hz L = V, 50/60 Hz Fault signal relay no code letter = NO C = NC **) Add code number in Order code for: Supply voltage, U c 1 = V, 50/60 Hz 2 = V, 50/60 Hz Fault signal relay 1 = NO 2 = NC 10 ABB
4 PSS18/30... PSS300/515 For normal starts. Inside Delta PSS18/ / PSS50/ / PSS18/ / PSS85/ / PSS85/ / Ordering details. Inside Delta V P e P e P e current, I e kw kw kw A Type *) Order code **) PSS18/ SFA R PSS30/ SFA R PSS37/ SFA R PSS44/ SFA R PSS50/ SFA R PSS60/ SFA R PSS72/ SFA R PSS85/ SFA R PSS105/ SFA R PSS142/ SFA R PSS175/ SFA R PSS250/ SFA R PSS300/ SFA R How to select correct size for heavy duty starts See the quick guide on page 6. P e P e P e current, I e kw kw kw A Type *) Order code **) PSS18/ SFA R PSS30/ SFA R PSS37/ SFA R PSS44/ SFA R PSS50/ SFA R PSS60/ SFA R PSS72/ SFA R PSS85/ SFA R PSS105/ SFA R PSS142/ SFA R PSS175/ SFA R PSS250/ SFA R PSS300/ SFA R PSS175/ / PSS175/ / *) Add code letter in Type for: Supply voltage, U c F = V, 50/60 Hz L = V, 50/60 Hz Fault signal relay no code letter = NO C = NC **) Add code number in Order code for: Supply voltage, U c 1 = V, 50/60 Hz 2 = V, 50/60 Hz Fault signal relay 1 = NO 2 = NC ABB 11
5 Accessories for PSS18/30... PSS300/515 Ordering details LZ... PSCT.. SB854C2 1SFT C1 1SFT C3 LT... -AC LT... -AL LE185 PSLW-44 LW... 1SFT C2 1SFT SFT C3 Current transformer for current limit function To be connected to terminals 11 and 12 on the softstarter. The setting range (1.5 4) corresponds to a multiple of the transformer ratio. Technical data below shows transformer ratio and number of turns for the primary winding. You can also use your own current transformer with corresponding transformer ratio and with minimum 1 VA. For softstarter Transformer ratio, type Number of turns Type Order code piece 1 piece PSS18/30 60/1 2 turns PSCT-60 1SFA R PSS30/52 60/1 1 turn PSCT-40 1SFA R PSS37/64 60/1 1 turn PSCT-50 1SFA R PSS44/76 60/1 1 turn PSCT-60 1SFA R PSS50/85 75/1 1 turn PSCT-75 1SFA R PSS60/105 75/1 1 turn PSCT-75 1SFA R PSS72/ /1 1 turn PSCT-100 1SFA R PSS85/ /1 1 turn PSCT-125 1SFA R PSS105/ /1 1 turn PSCT-150 1SFA R PSS142/ /1 1 turn PSCT-200 1SFA R PSS175/ /1 1 turn PSCT-250 1SFA R PSS250/ /1 1 turn PSCT-400 1SFA R PSS300/ /1 1 turn PSCT-400 1SFA R Cable connectors for Cu cables For Wire Tightening softstarter range torque type mm 2 max. Nm Type Order code piece 1 piece PSS85/ / SDA R PSS85/ /245 2x(50-120) 16 LZ185-2C/120 1SFN R PSS175/ / SDA R Cable connectors for Al and Cu cables For Wire Tightening softstarter range torque type mm 2 max. Nm Type Order code piece 1 piece PSS85/ / SDA R PSS85/ / SDA R PSS175/ / SDA R Terminal shrouds For softstarter type Suitable for Type Order code piece 1 piece PSS85/ /245 Cable connectors LT185-AC 1SFN R PSS85/ /245 Compression lugs LT185-AL 1SFN R PSS175/ /515 Cable connectors LT300-AC 1SFN R PSS175/ /515 Compression lugs LT300-AL 1SFN R Terminal nut washer For softstarter type Type Order code piece 1 piece PSS85/ /245 LE185 1SFN R PSS175/ /515 LE300 1SFN R Terminal enlargements For Wire softstarter range type mm 2 Type Order code piece 1 piece PSS18/ / x x PSLW-44 1SFA R PSS50/ / PSS18/ / x10,,,50 2x PSLW-72 1SFA R PSS85/ /245 LW185 1SFA R PSS175/ /515 LW300 1SFA R ABB
6 PST and PSTB For normal starts, class 10. In-Line PST30...PST72 PST85...PST142 PST175...PST300 PSTB370...PSTB470 PSTB570...PSTB1050 1SFC132014F0201 1SFC132018F0201 1SFC132015F0201 1SFC132013F0201 1SFC132017F0201 Ordering details In-Line PST30... PST V P e P e P e current, I e kw kw kw A Type Order code PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R P e P e P e current, I e kw kw kw A Type Order code PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PSTB PSTB1050 with integrated by-pass V P e P e P e current, I e kw kw kw A Type Order code PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R How to select correct size for heavy duty starts See the quick guide on page 16. P e P e P e current, I e kw kw kw A Type Order code PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R ABB
7 PST and PSTB For normal starts, class 10. Inside Delta PST30...PST72 PST85...PST142 PST175...PST300 PSTB370...PSTB470 PSTB570...PSTB1050 1SFC132014F0201 1SFC132018F0201 1SFC132015F0201 1SFC132013F0201 1SFC132017F0201 Ordering details Inside Delta PST30... PST V P e P e P e current, I e kw kw kw A Type Order code PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R P e P e P e current, I e kw kw kw A Type Order code PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PST SFA R PSTB370...PSTB1050 with integrated by-pass V P e P e P e current, I e kw kw kw A Type Order code PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R How to select correct size for heavy duty starts See the quick guide on page 16. P e P e P e current, I e kw kw kw A Type Order code PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R PSTB SFA R ABB 21
8 Accessories for PST and PSTB Ordering details LZ... LX... LW... SB854C2 1SFT C1 1SFT C2 1SFT C3 LE185 1SFT C3 1SFT C3 1SFT LT... -AC LT... -AL Cable connectors for Al and Cu cables For PST you need 9 pieces if also using the terminals B1, B2, B3 for external by-pass contactor. For Wire Tightening softstarter range torque type mm 2 max. Nm Type Order code piece 1 piece PST SDA R PST x (50-120) 16 LZ185-2C/120 1SFN R PST SDA R Cable connectors for Al and Cu cables For PST you need 9 pieces if also using the terminals B1, B2, B3 for external by-pass contactor. For Wire Tightening softstarter range torque type mm 2 max. Nm Type Order code piece 1 piece PST SDA R PST SDA R PST SDA R Terminal extensions For Dimensions softstarter hole ø bar type mm 2 mm Type Order code pieces 1 piece PST x 5 LX300 1SFN R PST x 5 LX185 1SFN R PSTB x 5 LX400 1SFN R PSTB x 6 LX750 1SFN R Terminal enlargements For Dimensions softstarter hole ø bar type mm 2 mm Type Order code pieces 1 piece PST x 3 LW110 1SFN R PST x 5 LW185 1SFN R PST x 5 LW300 1SFN R PSTB x 5 LW460 1SFN R PSTB x 6 LW750 1SFN R Terminal nut washer For softstarter type Type Order code piece 1 piece PST85/ /245 LE185 1SFN R PST175/ /515 LE300 1SFN R Terminal shrouds For softstarter type Req. qty Type Order code pieces 1 piece PST pcs and LT185-AC 1SFN R pcs LT460-AC 1SFN R PST pcs and LT185-AL 1SFN R pcs LT460-AL 1SFN R PST pcs LT300-AC 1SFN R PST pcs LT300-AL 1SFN R PSTB pcs LT460-AC 1SFN R PSTB pcs LT460-AL 1SFN R PSTB pcs LT750-AC 1SFN R PSTB pcs LT750-AL 1SFN R ABB
9 FBP FieldBusPlug AS-i Fieldbus Connectors and Accessories Orange cable AS-i FieldBusPlug Performance Ready-made AS-i Slave fieldbus interface with various cable lengths. Applicable on all FBP motor starters and devices with max. 4 input signals and 3 output signals Degree of protection IP65, diagnostic LED Designation FieldBusPlug Cable length Type Order code pieces 1 piece AS-i Performance 0.25 m ASP22-FBP.025 1SAJ R AS-i Performance 0.50 m ASP22-FBP.050 1SAJ R AS-i Performance 1.00 m ASP22-FBP.100 1SAJ R AS-i Performance 5.00 m ASP22-FBP.500 1SAJ R ASP22-FBP ASF11-FBP ASX11-FBP ASM11-FBP.0 ASF11-FBP.0 Accessories for AS-i Bus Connection AS-i Round Cable for Bus Junctions Ready-made bus cable with an M12 connector and an open cable end. Application on bus junctions such as e.g. AS-i couplers or devices with an integrated AS-i interface AS-i Round Cable with female connector 0.30 m ASF11-FBP.030 1SAJ R AS-i Round Cable with male connector 0.30 m ASM11-FBP.030 1SAJ R AS-i Round Cable for Bus Extension Ready-made bus cable with M12 male and female connectors AS-i Extension Cable 1.00 m ASX11-FBP.100 1SAJ R AS-i Extension Cable 3.00 m ASX11-FBP.300 1SAJ R AS-i Extension Cable 5.00 m ASX11-FBP.500 1SAJ R AS-i Extension Cable 100 m ASC11-FBP.999 1SAJ R AS-i Round Cable and Accessories for Bus Extension Bus cable and coupling accessories Designation Type Order code pieces 1 piece AS-i Round Cable, male conn. ASM11-FBP.0 1SAJ R AS-i Round Cable, female conn. ASF11-FBP.0 1SAJ R AS-i Flat-Cable Branch Circuit with M12 socket AST11-FBP.0 1SAJ R AS-i Addressing Device, Power Unit, miscellaneous accessories AST11-FBP.0 Designation FieldBusPlug Type Order code pieces 1 piece AS-i Addr. Device, including plug-in power unit ASA21-FBP.0 1SAJ R Power Unit PS 24V/5A, adjustable Systron PS24/ Address Signs for FieldBusPlug CAL11-FBP.0 1SAJ R ABB 23
10 FBP FieldBusPlug DeviceNet Fieldbus Connectors and Accessories Black cable DeviceNet FieldBusPlug Ready-made DeviceNet fieldbus interface with various cable lengths. Applicable on all FBP motor starters and other devices Degree of protection IP65, diagnostic LED Designation FieldBusPlug Cable length Type Order code pieces 1 piece DeviceNet 0.25 m DNP21-FBP.025 1SAJ R DeviceNet 0.50 m DNP21-FBP.050 1SAJ R DeviceNet 1.00 m DNP21-FBP.100 1SAJ R DeviceNet 5.00 m DNP21-FBP.500 1SAJ R DNP21-11FBP DNF-11FBP.050 DNM-11FBP.050 DNX11-FDP DNC11-FBP.999 DNM11-FBP.0 DNF11-FBP.0 Accessories for the DeviceNet Bus Connector DeviceNet round cable for bus junctions Ready-made bus cable with an M12 connector and an open cable end. Application on bus junctions such as e.g. DeviceNet couplers or devices with an integrated DeviceNet interface DeviceNet Round Cable with female connector 0.50 m DNF11-FBP.050 1SAJ R DeviceNet Round Cable with male connector 0.50 m DNM11-FBP.050 1SAJ R DeviceNet Round Cable for Bus Extension Ready-made bus cable with M12 male and female connectors DeviceNet Extension Cable 1.00 m DNX11-FBP.100 1SAJ R DeviceNet Extension Cable 3.00 m DNX11-FBP.300 1SAJ R DeviceNet Extension Cable 5.00 m DNX11-FBP.500 1SAJ R Device Net Round Cable 100 m DNC11-FBP.999 1SAJ R DeviceNet Round Cable and Accessories for Bus Extension Bus cable and coupling accessories Device Net Round Cable Male Connector DNM11-FBP.0 1SAJ R Device Net Round Cable Female Connector DNF11-FBP.0 1SAJ R Termination Resistor, Power Unit, Miscellaneous Accessories Designation Type Order code pieces 1 piece Device Net Termination Resistor, 120 Ohm DNR11-FBP.120 1SAJ R Power Unit PS 24 V/5 A, adjustable Systron PS24/ To connect the PST Softstarter to a DeviceNet fieldbus system... you need specific software for PLC set-up, (EDS file) which is available at on the Softstarter pages. Look under the documentation-link named Software. If you need help or advice, please contact your local ABB office. 24 ABB
11 FBP FieldBusPlug Fieldbus Connectors and Accessories Lilac cable FieldBusPlug Ready-made fieldbus interface with various cable lengths. Applicable on all FBP motor starters and other devices Degree of protection IP65, diagnostic LED Designation FieldBusPlug Cable length Type Order code pieces 1 piece -FBP 0.25 m PDP21-FBP.025 1SAJ R FBP 0.50 m PDP21-FBP.050 1SAJ R FBP 1.00 m PDP21-FBP.100 1SAJ R FBP 5.00 m PDP21-FBP.500 1SAJ R PDP21-FBP PDF11-FBP.50 PDM11-FBP.50 PDX11-FBP PDM11-FBP.0 PDF11-FBP.0 Accessories for the Bus Connector Round Cable for Bus Junctions Ready-made bus cable with an M12 connector and an open cable end. Application on bus junctions such as e.g.profibus DB couplers or devices with an integrated Profibus DB interface Round Cable with female connector 0.50 m PDF11-FBP.050 1SAJ R Round Cable with male connector 0.50 m PDM11-FBP.050 1SAJ R Round Cable for Bus Extension Ready-made bus cable with M12 male and female connectors Extension Cable 1.00 m PDX11-FBP.100 1SAJ R Extension Cable 3.00 m PDX11-FBP.300 1SAJ R Extension Cable 5.00 m PDX11-FBP.500 1SAJ R Extension Cable 100 m PDX11-FBP.500 1SAJ R Accessories for Bus Extension Designation Type Order code pieces 1 piece Male Connector PDM11-FBP.0 1SAJ R Female Connector PDF11-FBP.0 1SAJ R Termination Resistor, Miscellaneous Accessories Designation Type Order code pieces 1 piece Termination resistor, 120 ohm PDR11-FBP.120 1SAJ R To connect the PST Softstarter to a fieldbus system... you need specific software for PLC set-up, (GSD file) which is available at on the Softstarter pages. Look under the documentation-link named Software. If you need help or advice, please contact your local ABB office. ABB 25 1SEC132001C2101
Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB. Latest updated 2010-02-23 not printed, only in PDF-format
Main Catalogue Latest updated 2010-02-23 not printed, only in PDF-format Softstarters Type PSR Type PSS Type PST/PSTB Catalogue 1SFC132004C0201, Edition 7 February 2010 (1SFC132198F0001) News Functionality
More informationSoftstarters. The PSTB "Advanced" softstarter line Same features as PST except PSTB softstarters include ABB AF contactors for by-pass.
The PST "Advanced" softstarter line Wide main voltage range, 200-690 VAC Wide control voltage range, 100-250 V, 50/60 Hz Current ratings 30 to 1050 A (In Line) and 52-1800 A (Inside Delta) Same unit can
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Product description Wide rated operational voltage 208 600 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 18 to 370 A Wide ambient temperature range, -25 to +60 ºC
More informationSoftstarters. Index. 5 - Softstarters. Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com.
Index 5 5 - General information... 5.1 Softstarter overview...5.2-5.3 Applications...5.4-5.5 PSR - The compact range Description...5.7-5.8 Overview... 5.9 Ordering details... 5.10 Accessories... 5.11 Technical
More informationPSR The compact range Description
Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides
More informationPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Description Wide rated operational voltage 208 690 V AC Wide rated control supply voltage 100 250 V, 50/60 Hz Rated operational current 30 to 1050 A (Up to 1810 A inside delta) Wide ambient temperature
More informationUS Catalog. Softstarters Type PSTX and PSTB
US Catalog Softstarters Type PSTX and PSTB 2 1SXU132222C0201 Softstarters Catalog Softstarters type PSTX PSTX - The advanced range Description 4 Overview 6 PSTX and PSTB, Ordering details 8 Accessories,
More informationInstallation and Maintenance manual. Softstarters PST / PSTB
Installation and Maintenance manual Softstarters PST / PSTB Installation and maintenance PST30... PST1050 manual PST30...PSTB1050 Installation and maintenance manual Introduction... 1.1-1.3 1 Quickstart...
More informationSoftstarters Type PSR
Catalog Softstarters Softstarters ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 1 ABB Automation Products serve customers
More informationSoftstarters. Type PST30...PSTB1050 Installation and Commissioning Manual. Manual 1SFC132003M0201 June 2007. Fault. Power on Protection
Power on Fault Protection Power on Fault Protection Power on Fault Protection Power on Protection Fault Power on Protection Fault Softstarters Type PST30...PSTB1050 Installation and Commissioning Manual
More informationSoftstart. Upgrade to Torque control PSTB370 1050. Contents. 1. ESD Warning...2. 2. Tools...2. 3. PCB information...2. 4. Step by step...
Softstart Upgrade to Torque control PST30 300 PSTB370 1050 1SFC132040M0201 RevA Dec-06 Contents 1. ESD Warning...2 2. Tools...2 3. PCB information...2 4. Step by step...3 5. Configuration of the LV board...7
More informationSoftstarters Type PSE18...PSE370 Installation and commissioning manual
Softstarters Type PSE18...PSE370 Installation and commissioning manual PSE 18-600-70 PSE 18-600-70 PSE 18-600-70 This manual belongs to: 2 Softstarters Type PSE18...PSE370 Installation and commissioning
More informationSoftstart. Changing of Printed Circuit Board, Display, Keypad and upgrade to Torque control PSTB370 1050. Contents. 1. ESD Warning...2. 2. Tools...
Softstart Changing of Printed Circuit Board, Display, Keypad and upgrade to Torque control PST30 300 PSTB370 1050 1SFC132009M0201 Rev A Dec-06 Contents 1. ESD Warning...2 2. Tools...2 3. PCB information...2
More informationSoftstarters. Type PSE Fieldbus communication DeviceNet for PSE fw rev. 01.01.02. 1SFC132066M0201 November 2010 1SFC132066M0201 1
Softstarters Type PSE Fieldbus communication DeviceNet for PSE fw rev. 01.01.02 1SFC132066M0201 November 2010 1SFC132066M0201 1 DeviceNet The DeviceNet protocol is a fieldbus protocol that provides full
More informationTechnical Catalogue. Automation Components ABB
Technical Catalogue Automation Components ABB Components that suit each other Programmable Logic Controllers, I/O-Modules & Operator Terminals Proximity Switches Wireless Sensors & FBP FieldBusPlug Communicative
More informationSoftstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU 06.00.00. 1SFC132070M0201 February 2011 1SFC132070M0201 1
Softstarters Type PST/PSTB Fieldbus communication CANopen for PST sw CU 06.00.00 1SFC132070M0201 February 2011 1SFC132070M0201 1 CANopen The CANopen protocol is a fieldbus protocol that provides full control
More informationPanorama. Softstarters The complete range
Panorama Softstarters The complete range Why does soft starting matter? Controlling industrial electricity. The vast majority of the world s industrial applications are driven by motors. It is estimated
More informationNumber 1 in efficiency
PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why
More informationSoftstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April 2015 1SFC132089M0201 1
Softstarters Type PSTX Fieldbus communication, Built-in Modbus RTU 1SFC132089M0201 April 2015 1SFC132089M0201 1 1 Modbus RTU The Modbus protocol is a fieldbus protocol that provides full control and status
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationAllen-Bradley 1397 400-600HP AC Line Filter Kit
Installation Instructions IN Allen-Bradley 1397 400-600HP AC Line Filter Kit Cat. Nos. 1397-LF600 What This Option Provides What This Kit Contains This option is intended to be applied when the primary
More informationBulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
More informationHARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols.
HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter
More informationGivare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationDeviceNet Bus Software Help for Programming an Allen Bradley Control System
FBP FieldBusPlug V7 DeviceNet Bus Software Help for Programming an Allen Bradley Control System DeviceNet Software Help for Programming an Allen Bradley Control System Contents Page General Purpose...
More informationSmartWire Panel Wiring Solutions the easy way to connect
SmartWire Panel Wiring Solutions the easy way to connect Richard Chung SmartWire Program Manager Milwaukee, WI 2008 Eaton Corporation. All rights reserved. SmartWire Panel Wiring Solution Key Customer
More informationInstallation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C
Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS
More informationCPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationEFC 3600. Frequency converters
2 Bosch Rexroth AG Electric Drives and Controls Documentation Compact and complete: space saving side-by-side assembly, plug-in I/O terminals, with brake chopper and mains filter for ultra-simple installation
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationAltistart. 01 Soft Start The starting solution. For single-phase and three-phase asynchronous motors 3 to 85 Amps 1/4 to 75 HP (0.
Altistart 01 Soft Start The starting solution For single-phase and three-phase asynchronous motors 3 to 85 Amps 1/4 to 75 HP (0.37 to 75kW) T Advanced functionality in a mini soft start The Altistart 01
More informationTechnical catalogue. Modular DIN rail components Installation contactors
Technical catalogue Modular DIN rail components Installation contactors Installation Contactors Overview... ESB Installation Contactors 0 A / AC-/AC-7a ESB0...4 4 A / AC-/AC-7a ESB4...5 40 A / AC-/AC-7a
More informationSPEED CONTROL SYSTEM
SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W
More informationAuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:
AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use: advanced soft start and soft stop control protection functions that operate even when
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationDigital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
More informationKit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
More informationMagnetic Proximity Switches Series CST - CSV and CSH
Magnetic Series CST - CSV and CSH Reed, Electronic»» Designed to fit into the cylinder profile barrel»» 3 models (CST - CSV - CSH) are suitable for all Camozzi s cylinder range»» With or without M8 connector
More informationFrequency Converter Fv
2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)
More informationLow Voltage Products. Switches Automatic Transfer Switches
Low Voltage Products Switches Automatic Transfer Switches Growing importance of a secure power supply Standby power is an integral part of many industrial and domestic electrical systems. High energy prices,
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationAF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101403D0201 24/03/11 AF09-30-22-.. / AF09Z-30-22-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF09(Z) contactors are used for controlling power circuits
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationSIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationOptions for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface
Options for ABB drives, converters and inverters User s manual FDPI-02 diagnostics and panel interface Table of contents Table of contents 3 1. FDPI-02 diagnostics and panel interface Safety..............................................
More informationSECTION 26 29 23 VARIABLE FREQUENCY DRIVES
SECTION 26 29 23 VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 SCOPE A. Furnish and install individual freestanding variable frequency AC drives (VFD) as shown on the Drawings and specified herein. 1.02
More informationINDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016. www.elipse-automation.eu
INDUSTRIAL AUTOMATION EQUIPMENT EDITION 2016 Your partner in an automated industry Our combination of technical know-how, product responsibility and on-time deliveries guarantees you the best WHY CHOOSE
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationRF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc. http://www.spincore.com
RF Power Amplifier PA10W Owner s Manual SpinCore Technologies, Inc. http://www.spincore.com Congratulations and thank you for choosing a design from SpinCore Technologies, Inc. We appreciate your business!
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationAir damper actuators
4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically
More informationCruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor
CruzPro VAF110 AC Volts, Amps, Frequency, kw Monitor Table of Contents Introduction............................ 3 Specifications........................... 4 Installation..............................5
More informationPower Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN
Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit
More information80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
More informationHelmut Schoenfelder, ABB Stotz-Kontakt, 31.03.2015 UMC100.3 Technical Presentation. ABB Stotz-Kontakt May 18, 2015 Slide 1
Helmut Schoenfelder, ABB Stotz-Kontakt, 31.03.2015 UMC100.3 Technical Presentation ABB Stotz-Kontakt May 18, 2015 Slide 1 ABB Solutions for Motor Feeders Standard Protection Functions overload short circuit
More informationTechnical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
More informationIntroduction to the Actuator Sensor-Interface
Introduction to the Actuator Sensor-Interface Andy Verwer Automation Systems Centre, Manchester Metropolitan University Outline of Presentation Introduction to the Actuator-Sensor Interface,. Characteristics
More informationPA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.
Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor
More informationCatalog. Modular DIN rail components Installation contactors
Catalog Modular DIN rail components Installation contactors 0 CDC00C00 Installation contactors Benefits and features Overview Ordering details ESB installation contactors ESB0 ESB ESB0 ESB 7 EN installation
More information12 Series - Time switches 16 A. Features 12.01 12.11 12.31
Mechanical time switches - daily time setting Type 12.01-1 Pole 16 A CO (SPDT) Type 12.11-1 Pole 16 A O (SPST-O) 17.6 mm width Type 12.31-0000 - 1 Pole 16 A CO (SPDT) Type 12.31-0007 - 1 Pole 16 A CO (SPDT)
More informationElectronic overload relay EF19 and EF45
Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationInstall the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
More informationABLOY DA60 SWING DOOR OPERATOR Installation and commissioning manual Abloy Oy An ASSA ABLOY Group company APPROVALS / STANDARDS Low Voltage directive 7//EEC as amended by the directive 9/68/EEC EMC directive
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationArecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
More informationNXL Series Inverters. HVAC Inverters made simple
NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter
More informationABB central inverters PVS800 100 to 1000 kw
Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationField bus connections Link structure CMS link structure CMS, B-design. Brochure
link structure CMS, B-design Brochure 2 link structure CMS, B-design Bus coupler with driver Optional field bus connection with I/O function (CMS), B-design Bus coupler with driver Field bus protocol:
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationSafety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
More informationABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
More informationAC 800M. EtherNet/IP DeviceNet Linking Device LD 800DN. Power and productivity for a better world TM SP1134
AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN SP1134 Power and productivity for a better world TM AC 800M EtherNet/IP DeviceNet Linking Device LD 800DN NOTICE This document contains information
More informationMINIMAT-EC-Servo Screwdriver Spindles
Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range
More informationNF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101433D0201 28/03/11 NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits.
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationKOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB
KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB KOLMA and IHDA Indoor Type Cable Current Transformers Index Description... 3 Technical
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationLine Level Converter Box. S Class Signal Processors
Line Level Converter Box S Class Signal Processors Table Of Contents Introduction and Features 3 Front and Rear Panel Layout 4 Operating the S convert Using the LEVEL controls 5 Typical Set-up 6 Wiring
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.
More informationContractors Guide Central Inverter System Installation
Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.
More informationUninterruptible Power Supply. 500 kva - 750 kva
9 315 Uninterruptible Power Supply 500 kva - 750 kva T1 and T3 Installation Addendum 164201244-001 Rev. A ------------------------------------------------------------------------ ------------------------------------------------------------------------
More informationM1000 Process Alarm Monitor
Data Sheet Process Alarm Monitor Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationCatalog. Arc Guard System TM TVOC-2
Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already
More informationUser Manual. Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com
Air-conditioner Controller SB-DN-HVAC (MAC01.331) www.hdlautomation.com Document updates: Version Data Description V1.0 2015.05.25 Finish new document HVAC Controller User Manual INDEX 1. Overview...1
More informationSYSTEM 4C. C R H Electronics Design
SYSTEM 4C C R H Electronics Design SYSTEM 4C All in one modular 4 axis CNC drive board By C R Harding Specifications Main PCB & Input PCB Available with up to 4 Axis X, Y, Z, A outputs. Independent 25
More informationPOWER SUPPLY MODEL XP-15. Instruction Manual ELENCO
POWER SUPPLY MODEL XP-15 Instruction Manual ELENCO Copyright 2013 by Elenco Electronics, Inc. REV-A 753020 All rights reserved. No part of this book shall be reproduced by any means; electronic, photocopying,
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationTechnical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
More informationMLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More information