Softstarters Type PSR



Similar documents
PSR The compact range Description

Softstarters. Main Catalogue. Type PSR Type PSS Type PST/PSTB. Latest updated not printed, only in PDF-format

Phone: Fax: Web: info@clrwtr.com

Softstarters. Index. 5 - Softstarters. Phone: Fax: Web: info@clrwtr.com.

Phone: Fax: Web: info@clrwtr.com

Panorama. Softstarters The complete range

Electronic overload relay EF19 and EF45

Installation and Maintenance manual. Softstarters PST / PSTB

Softstarters. Type PST30...PSTB1050 Installation and Commissioning Manual. Manual 1SFC132003M0201 June Fault. Power on Protection

Electronic overload relay EF65, EF96 and EF146

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Softstart. Upgrade to Torque control PSTB Contents. 1. ESD Warning Tools PCB information Step by step...

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

40.3. Control Relays and Timers

Softstarters Type PSE18...PSE370 Installation and commissioning manual

Softstart. Changing of Printed Circuit Board, Display, Keypad and upgrade to Torque control PSTB Contents. 1. ESD Warning Tools...

Altistart. 01 Soft Start The starting solution. For single-phase and three-phase asynchronous motors 3 to 85 Amps 1/4 to 75 HP (0.

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Number 1 in efficiency

Mykstartere. Type PSS Type PST/PSTB - New range. Katalog 1SEC132001C2101, Juli SFC132016F0201

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Catalog. Modular DIN rail components Installation contactors

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

SOFTSTARTER HANDBOOK

Manual motor starter MS116

US Catalog. Softstarters Type PSTX and PSTB

Products and solutions for machine builders (OEM) 100% electricity

3753 en /b VE/B - VE/RG Va V riable speed drives

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

D-Line Contactors, Overload Relays and Accessories

49 Series - Relay interface modules A. Features

Safety technique. Emergency stop module BO 5988 safemaster

Torque control MSF Softstarter

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Relés e Contatores de Estado Sólido SIRIUS

Circuit Breakers. NRC Series. NRC Series

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Three-phase monitoring relay CM-PFE

48 SERIES Relay interface modules 10 A

Frequency Converter Fv

Products and solutions for lifting systems

INDUSTRIAL AUTOMATION EQUIPMENT EDITION

mecotron Safety relay ESTOP-2 For emergency stop monitoring

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

... Electronic Softstarter...

Circuit Breakers. Next Generation of Protection Capabilities

HERZ-Thermal Actuators

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RM4TG20 three-phase network control relay RM4-T - range V

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Contact expansion modules

WYE-DELTA AND SOLID STATE STARTER APPLICATION GUIDE

Products and solutions for pumping, irrigation and piping

Contact expander modules

Handbook Softstarter Handbook

SMS 4 / SMS 5 safety mat Product information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Safety Relays ESM/ESM-F

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

MOTOR CONTROL IS OUR NATURE

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Manual Motor Starter MS 116 up to 16 A Technical Data

Power Supplies 3. SDN-P DIN Rail Series

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

80 Series - Modular timers 16 A. Features

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

E-STOP relays, safety gate monitors

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Digital input modules

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

E-STOP relays, safety gate monitors

1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting

TX OPEN RS232/485 module

Speed Control Relays SX2

CompactLogix Power Supplies Specifications

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Softstarters. Type PST/PSTB Fieldbus communication CANopen for PST sw CU SFC132070M0201 February SFC132070M0201 1

Rotary Phase Converters

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PHOENIX CONTACT Features

Efficient and reliable fans, compressors and blowers

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

SMC -3 Specifications

E-STOP relays, safety gate monitors

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Transcription:

Catalog Softstarters

Softstarters ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 1 ABB Automation Products serve customers worldwide and have long experience and comprehensive know-how of the development and production of softstarters. After the PSS and the PST(B) ranges, it is now time to introduce the small compact PSR Softstarter. The Softstarter is the solution to both mechanical and electrical problems. Constant-speed AC motors are the workhorses of industry; they are used to drive fans, pumps, conveyors and lots of other types of machinery. These motors are tough machines, but they have some drawbacks. During start and stop both mechanical and electrical stresses are high, causing undesirable load peaks each time the motors are started. An ABB Softstarter eliminates many of these problems. The voltage is smoothly applied to, and removed from, the motor. Both the torque and the current consequently behave in the same way. The result is that mechanical and electrical stresses are significantly lower than with conventional starting methods. Fewer electrical problems The starting current will be significantly lower than with across the line starting and compared with Y/D starters the switching transients will be eliminated. Fewer mechanical problems Sliding drive belts and gearbox wear caused by heavy torque peaks are familiar problems that require lots of maintenance. Our PSR Softstarters reduce the torque peaks as they apply the torque smoothly. Fewer operational problems Pressure surges in pipelines are often called water hammer. It is a common but undesirable effect when stopping almost all pumps. PSR Softstarters allow smooth stops and reduce the problems associated with water hammer. 1 In the background an application example, a snow cannon from Lenko Snow, Sweden ABB softstarters - Advanced, Flexible and Compact Range ABB offers three different ranges of softstarters to cover every customer need for solutions for small to medium-sized motor applications. PST(B) - Advanced range, covers motor currents from 30 to 1050 A and provides advanced functionality, including integrated protections, programmable signal relays, a flexible communication system and an LCD display. Sizes PSTB370 to 1050 A include a by-pass contactor as a standard function. PSS - Flexible range covers motor currents from 18 to 300 A and offers a flexible solution with easy installation and setup. It can also be connected in-line or inside delta. PSR - Compact range, covers motor currents from 3 to 45 A. It is the latest addition to the softstarter family and has an attractive, compact design. Further, the system concept includes the possibility to easily connect our Type MS manual motor protectors when used in Group motor applications and the softstarters are available for remote control connection using the FieldBusPlug as an accessory. All sizes include a Run signal relay. The 25A and above are also provided with an output signal for TOR (Top Of Ramp), i.e. full voltage). With standard performance the PSR Softstarters handle ten starts per hour. When an auxiliary cooling fan is added, the starting capacity is increased to 20 starts per hour. l Current ratings 3.9 45 A l Motor voltage 208 600 V l Supply voltage 24 V DC or 100-240 V AC l Easy to install and adjust l DIN rail or screw mounting With their compact design, the PSR Softstarters are ideal for installation in places where space is limited and where there is a demand for easy installation. Low Voltage Products & Systems

PSR3... PSR45 Softstarters Motor power 208 V 240 V 480 V 600V Max rated Weight motor PSR3... PSR16 PSR25, PSR30 P e P e P e P e current, I e HP HP HP HP A Catalog No. List Price 208 600 V AC Supply voltage 100-240 V AC 0.5 0.75 2 2 3.4 PSR3-600-70 $ 190 1 1.5 3 5 6.1 PSR6-600-70 225 2 2 5 7.5 9.0 PSR9-600-70 265 3 3 7.5 10 11.0 PSR12-600-70 270 3 5 10 10 15.2 PSR16-600-70 310 7.5 7.5 15 20 24.2 PSR25-600-70 320 7.5 10 20 25 28.0 PSR30-600-70 410 10 10 25 30 34.0 PSR37-600-70 510 15 15 30 40 46.2 PSR45-600-70 640 Supply voltage 24 V DC 0.5 0.75 2 2 3.4 PSR3-600-81 190 1 1.5 3 5 6.1 PSR6-600-81 225 2 2 5 7.5 9.0 PSR9-600-81 265 3 3 7.5 10 11.0 PSR12-600-81 270 3 5 10 10 15.2 PSR16-600-81 310 7.5 7.5 15 20 24.2 PSR25-600-81 320 7.5 10 20 25 28.0 PSR30-600-81 410 10 10 25 30 34.0 PSR37-600-81 510 15 15 30 40 46.0 PSR45-600-81 640 PSR37... PSR45 Accessories Description Catalog No. List price Fieldbus Plug Connection Accessory The same accessory for all sizes PSR-FBPA $ 290 PSR-FBPA Connection kit PSR3-16 and MS116 PSR16-MS116 12 Connection kit PSR37-45 and MS450 PSR45-MS450 25 PSR16-MS116 Fan All sizes can be equipped with auxiliary cooling fan for increased starting capacity. PSR-FAN 64 PSR-FAN ABB Field Bus Plug The same accessory for all sizes, see Catalog LV023, Product Selector, pages 6.33-6.35, November 2005 or later revisions. Low Voltage Products & Systems Discount schedule PSR 3

Softstarters PSR3... PSR45 Technical data Technical data Rated insulation voltage, U i 600 V Rated operational voltage, U e 08...600 V Rated supply voltage, U s 100...240 V AC or 24 V DC Rated operational current, I r PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 3.9 A 6.8 A 9 A 12 A 16 A 25 A 30 A 37 A 45 A Starting capacity at I r 4 x I r for 6 sec. Number of starts per hour, standard 10 (4 x I e during 6 s) with aux. fan 20 (4 x I e during 6 s) Service factor 100 % Ambient temperature during operation 1) -25 C to +60 C -13 F to +140 F during storage -40 C to +70 C -40 F to +158 F Maximum altitude 2) Settings 4000 m Degree of protection, PSR3 PSR6 PSR9 PSR12 PSR16 PSR25 PSR30 PSR37 PSR45 main circuit IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP10 IP10 control circuit IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 Connectable cable area, PSR3 - PSR16 PSR25 - PSR30 PSR37 - PSR45 main circuit 1 x 2.5 mm 2 (1 x 14 AWG) 1 x 10 mm 2 (1 x 8 AWG) 1 x 35 mm 2 (1 x 2 AWG) x 2.5 mm 2 (2 x 14 AWG) x 10 mm 2 (2 x 8 AWG) x 16 mm 2 (2 x 6 AWG) PSR3 - PSR16 PSR25 - PSR45 control circuit 1 x 2.5 mm 2 (1 x 14 AWG) 1 x 2.5 mm 2 (1 x 14 AWG) x 2.5 mm 2 (2 x 14 AWG) x 1.5 mm 2 (2 x 16 AWG) Signal relays PSR3 - PSR16 PSR25 - PSR45 for Run signal Resistive load 40 V, 2 A 50 V, 5 A AC-15 (Contactor) 240 V, 0.5 A 50 V, 0.5 A for Top of Ramp signal Resistive load - 50 V, 2 A AC-15 (Contactor) - 50 V, 0.5 A LED for On/Ready for Run/Top Of Ramp Setting of Start Ramp Stop Ramp Green Green 1-10 sec. 0-20 sec. Initial- and End Voltage 40-70% 1) Above 40 C (104 F) up to max. 60 C (140 F) reduce the rated current with 0.8 % per C (0.44% per F) to derate the softstarter. EX: At 122 F, the derating is: 122 F - 104 F = 18 F; 18 F x 0.44 = 7.92%, approximately 8%. Current FLA is derated by 8%. 2) When used at high altitudes above 1000 meters (3300 feet) up to 4000 meters (13,000 feet) you need to derate the rated current using the following formula. x - 1000 [ % of I e = 100 - ], where x = actual altitude for the softstarter 150 U 1 2 3 3 U ini Start 1 Stop 2 time 1 Ramp time START = 1... 10 sec 2 Ramp time STOP = 0... 20 sec 3 Initial voltage U ini =40... 70 % (also set end voltage ) 4 Low Voltage Products & Systems

PSR3... PSR45 Technical data Softstarters UL ratings (File #E161428) Softstarter Motor power P (hp) and full load current FLA (A) Max. fuse Max Breaker U e U e U e U e FLA 208 V 240 V 480 V 600V Type A hp hp hp hp Type A 208 600 V AC Supply voltage 100-240 V AC alt. 24 V DC PSR3 3.4 0.5 0.75 40 A J-Type 50 PSR6 6.1 1 1.5 3 5 40 A J-Type 50 PSR9 9 5 7.5 40 A J-Type 50 PSR12 11 3 3 7.5 10 40 A J-Type 50 PSR16 15.2 3 5 10 10 40 A J-Type 50 PSR25 24.2 7.5 7.5 15 0 60 A J-Type 100 PSR30 28 7.5 10 0 25 70 A J-Type 100 PSR37 34 10 10 5 30 100 A J-Type 150 PSR45 46.2 15 15 30 40 100 A J-Type 150 Low Voltage Products & Systems 5

Softstarters PSR3... PSR45 Application diagrams PSR3...16 A) With MCCB B) With MCCB and auxiliary contact C) With fuses, contactor and O.L. L/+ N/C L/+ N/C L/+ N/C MCCB MCCB PSR25... 45 D) With MCCB E) With MCCB and auxiliary contact F) With fuses, contactor and O.L. L/+ N/C L/+ N/C L/+ N/C MCCB MCCB A26...50 6 Low Voltage Products & Systems

PSR3... PSR45 Dimensions Softstarters PSR3... 16 PSR3... 16 PSR25... 30 PSR25... 30 PSR37...45 PSR37...45 Low Voltage Products & Systems 7

ABB is leader in power and automation technologies that enable utility and industry customers to improve performance while lowering their environmental impact. Together with our program of low voltage products, we also offer worldwide support and easy access to all documentation such as installation drawings, dimension drawings, coordination tables and certificates. For more information please visit www.abb.us/controlproducts Publication LV063 No. Printed in USA, January, 2007 ABB Inc. 1206 Hatton Road Wichita Falls, TX 76302 Telephone 888-385-1221; 940-397-7000 Fax 940-397-7085 http://www.abb-control.com ABB Inc. 2105 32nd Avenue Lachine, QC H8T 3J1 Canada Telephone: 800-567-0203 (Atlantic & Quebec region) 866-460-3300 (Ontario Region) 866-222-8368 (Midwest & Pacific region)