Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems



Similar documents
POST AND FRAME STRUCTURES (Pole Barns)

Additions and Alterations

Mark Cramer Inspection Services, Inc.

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

1/2" CDX PLY W/ 6"/ 6"/ 12" 2x ROOF 16"OC W/ R-30 BATT. INSUL. (COMMON NAILS)

Superform Products Ltd.

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

STANDARD OPEN PATIO COVER

8/18/14. Introduction to. Framing. Terminology and Concepts

SUPER SHED. Indoor shelter for your outdoor tools.

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

Page & Turnbull imagining change in historic environments through design, research, and technology

TYPICAL PATIO COVERS 111

Best Barns USA Assembly Book

Section A Roof Truss

PDmB, Inc. Definitions

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Chapter 6 ROOF-CEILING SYSTEMS

Attached/Detached Patio Cover/Carport

March 14, Installation of Bay, Bow and Garden Windows

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Whitley Manufacturing Co., Inc. 201 W. First Street S. Whitley, IN Phone (260) Sales Fax (260)

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

COMMONLY USED RESIDENTIAL BUILDING CODES

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Pre-Drywall Inspection Report

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Building Construction. Lightweight construction. Conventional Construction

PANELIZED HOME INSTALLATION GUIDELINE

Residential Building Inspection Policies

Footing and Temporary Power Inspection

Asphalt Shingle Application Requirements

Residential Deck Safety, Construction, and Repair

How to secure your property after a disaster

Pole Building Estimate Number: /2/2010 NORTH SIDE-EAVE SIDE 2 ELEVATION

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

NAVAJO COUNTY ADDENDA & ADDITIONS TO THE INTERNATIONAL BUILDING CODES. Public Works/Planning & Zoning Building & Safety AMENDED ( )

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

DEFAULT HEAT LOSS COEFFICIENTS

Formwork for Concrete

Patio Covers / Carports

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Casa de Dios. Ventilated Improved Pit Latrine. Construction Plans

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Basic Requirements for Residential Plan Review _

2014 FLORIDA BUILDING CODE

ISO Types 1-6: Construction Code Descriptions


Typical Finished Basement Details

A0 SHEET 1 OF LOCUST STREET FRANKFORT, KANSAS FRANKFORT, KANSAS ROOF REPAIR OF THE 400 LOCUST STREET

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Residential Decks. Planning and Development Services Department

AMERICAN GOTHIC PLAYHOUSE

EnergyMate Homes - Lexington Series

INSTALLATION OF A BAY WINDOW

Uncovered Decks & Porches

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

BEAMCHEK EXAMPLES. RIDGE BEAM SIMPLE SPAN EXAMPLE No. 1 ACTUAL MATERIALS, LOADS AND CODE REQUIREMENTS MAY VARY. THIS IS AN ILLUSTRATION ONLY.

CHAPTER 6 CONSTRUCTION TYPES

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Sample Drawing Package for One and Two Family Dwelling Applications

Excerpts from the Canadian National Building Code (NBC)

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines

How To Repair A Boat Landing Deck With A Boat Bed

Georgia Association of Home Inspectors

PANEL CONCEPTS LLLP.

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

CALIFORNIA BUILDING CODE

Typical Finished Basement Details

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE

Protecting Your Home from Wind Damage

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Building Information Packet

Owner's Manual & Assembly Instructions

MICHIGAN RESIDENTIAL CODE 2003

providing documentation that validates the year of construction. Acceptable documents include

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

Estimated Cost of Repair

Engineered Wood Foundations

Owner's Manual & Assembly Instructions

Ceiling Mounted Folding Attic Ladders Installation Instructions

Happily PHOTOGRAPHY BY MICHAEL ANDERSON AND LARRY OKREND

Chapter 3 Pre-Installation, Foundations and Piers

Certification: Building Plans Examiner. Exam ID: B3

INFORMATION BULLETIN NO.

STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA

The Cabin Shell Series

How To Make A House Safe

DETAILS FOR CONVENTIONAL WOOD FRAME CONSTRUCTION

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

HfHMD uses LP SmartSide siding and trim.

6 RETROFITTING POST & PIER HOUSES

Transcription:

P O Box 34 Mendon, Utah Custom 30 x 20-8 Garage Plan Plan #g233 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical Section Page Materials List @COPYRIGHT SDSCAD 1

30 year dimensional shingles and sturdy panel siding running vertical with 8" on center groove. Nailing schedule is 6" on ends 12" on centers 6d nails. Trusses are engineered on 24" and framing is 2" x " on 16" centers. 8' ceiling height. 30'-0" SINGLE POUR CORNER INSTALLATION ONE #4 REBAR IN SHEAR CONE 12" MINIMUM REBAR LENGTH 20'-0" '-6" 5'-0" '-6" 5030 A (2) 2" x 10" Nailed Header (2) 2" x 10" Nailed Header 800 A 1600 A 3068 WP 3'-0" 3'-0" 14'-0" 20'-0" 30" MINIMUM REBAR LENGTH CDX PLYWOOD SHEAR WALL INSTALLED W/ LONG DIMENSION ACROSS STUDS. STAGGER VERTICAL JOINTS PANEL SHEATHING USED AS CORNER BRACING W/ LONG DIMENSION PARALLEL TO STUDS SIDING MATERIAL STRUCTURAL PANEL CAN ACT AS SIDING IF EXTERIOR GRADE CORNER DISTANCE FROM EDGE STRAP TO CORNER Simpson Strong-Tie HPAHD HPAHD straps for all (A) Alternate Braced Wall Panels See detail below for all () Braced Wall Panels LEAVE 1/4" GAP @ EDGES & 1/8" GAP @ ENDS UNLESS OTHERWISE REC- OMMENDED BY MANUFACTURER WALL FRAMING P O Box 34 Mendon, Utah 2'-0" 8'-0" 2'-0" 16'-0" 2'-0" 30'-0" 10d NAILS @ 6" O.C. AT EDGES & SEAMS AND 10d NAILS @ 12" O.C. IN FIELD U.N.O. ON SHEAR WALL SCHEDULE TYPICAL BRACED WALL PANEL () N.T.S. GARAGE MAIN FLOOR PLAN SCALE 1/4"=1' @COPYRIGHT SDSCAD 2

GRADE 2 % MIN. SLOPE 8" @32" MAX. SPACING. BOLTS SHALL BE EMBEDDED " MIN. 4" CONC. SLAB 4" COMPACTED GRAVEL 30'-0" 8" MIN. THICKNESS CONCRETE WALL Footing and concrete wall option Bottom of footing to be a min of 24" below grade or as required by local code 4" Concrete Floor over compacted gravel fill, sloped 1" per 10' to door Thickened edge slab 16" x 24" 20'-0" P O Box 34 Mendon, Utah 1/2" ANCHOR BOLT 32" O.C. 4" CONCRETE SLAB 6" MIN. GRADE VAPOR BARRIER 4" GRAVEL BASE 16" X 24" DEEP CONT. CONCRETE THICKENED EDGE SLAB Monolithic slab foundation option FOUNDATION PLAN SCALE 1/8"=1' Concrete: 1. All slabs are to be 4" concrete over 4" gravel unless otherwise noted on the plans. 2. Concrete to be ACI 301-66, Type II cement, 2500 psi at 28 days, 5" maximum slump. 3. Reinforcing to be ASTM A615-Bars with Fy=60 ksi lamp 30 diameter minimum at splices or weld per ACI Std. 4. Concrete design based on Fc 2000 psf, Fc 2500 psi for quality only. 5. Anchor bolts shall be A-30 embedded " minimum into concrete or masonry grout. 6. All footings minimum 24" below final grade @COPYRIGHT SDSCAD 3

P O Box 34 Mendon, Utah RIGHT ELEVATION REAR ELEVATION SCALE 1/8"=1' LEFT ELEVATION 4 /12 PITCH Asphalt Shingles Sturdy Panel Structural Siding 8' Tall 2 x Walls PICTORIAL FRONT ELEVATION SCALE 1/4"=1' 4 @COPYRIGHT SDSCAD

5030 A (2) 2" x 10" Nailed Header (2) 2" x 10" Nailed Header A GARAGE RO PRE-ENGINEERED TRUSSES AS SUPPLIED BY TRUSS MANUFACTURER 24" o.c. End Walls Cross Section A 8' Tall 2 x Walls Back Wall Front Wall WALL FRAMING SECTIONS SCALE 1/8"=1' Roof Framing: 1. Fascia to be 2"x Douglas Fir. 2. For soffit size see details. 3. For spans and dimensions refer to floor plans. 4. Trusses are to be an approved truss design from the truss manufacture's engineer. 5. Use Simpson H-1 hurricane anchors at each truss or rafter to wall connection. 6. Solid blocking required between joists, rafters, and trusses over all bearing walls. Such blocking shall be 1 ½" minimum thickness and full depth of joists, rafters, or trusses.. Minimum header sizes shall be according to the header size table unless otherwise noted. 8. Basis of design roof live/snow load of 3 psf, and roof dead load of 15 psf. 9. Plywood roof decking to be Min ½" thick, 24/0, CDX or 5/8 wafer. General framing: (Douglas Fir) 1. Minimum header sizes shall be according to the following table unless otherwise noted. Header sizes (single story construction) 2'-0" to 4'-0" Span 2-2x4's 4' + to 6'-0" Span 2-2x6's 6' + to 8'-0" Span 2-2x8's 8' + to 10'-0" Span 2-2x10's 10' + to 12'-0" Span 2-2x12's or as noted on plan 2. Brace all exterior walls and cross-stud partitions at each end of building and at least every 25' of length by one of the following: a. Simpson WB 126 wall bracing with 3-16d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of /16 inch. 3. Fire stopping: a. Fireblock stud spaces over 10' in height, furred spaces, soffits, drop ceilings, cove ceilings, stair stringers at top and bottom of run, bearing walls and ceiling joist lines, etc. Firestopping shall consist of 2" nominal lumber. b. Firestop openings around vents, pipes, ducts, chimneys, and fireplaces at ceiling and floor levels with approved noncombustible materials. 4. CDX plywood is not approved where exposed to weather, i.e., roof overhangs. 5. Exterior wall framing to be 2"x6" studs at 16" o.c. Interior wall, framing at non-bearing walls to be 2"x4" studs at 24" o.c. and at bearing walls 2"x4" studs at 16" o.c. with double top plate. 6. Shear wall to be /16" Sheathing, see detail.. All stress grade lumber shall comply with WCLA specs and bear approval stamp on all pieces in place. 8. Framing lumber shall be Douglas Fir construction grade Fb 1450 or better unless otherwise noted. 9. Nailing to be per current U.B.C. unless otherwise noted. 10. All bearing partitions shall have double top plates. 11. Structural glued laminated timbers to be stamped by an approved agency. 12. Use redwood or pressure treated sole plates at all exterior walls. @COPYRIGHT SDSCAD 5 P O Box 34 Mendon, Utah

P O Box 34 Mendon, Utah ASPHALT SHINGLES OVER 30# FELT /16" SHEATHING SIMPSON H1 TRUSS CLIP 1 x 6 FASCIA PRE-ENGINEERED TRUSSES @ 24" O.C. 2 x STUD @ 16" O.C. 12 4 12" MIN /16" MIN STRUCTUTAL SHEATHING 2 x MUDSILL 1/2" x 10" ANCHOR BOLT EMBEDDED " INTO CONC. 4" CONC. SLAB OVER 4" GRAVEL 2% SLOPE TO OUTSIDE 9" 5" 8" 1'-6" GARAGE TYPICAL SECTION 6 @COPYRIGHT SDSCAD

P O Box 34 Mendon, Utah Computer Generated Materials List for reference only and gives approximated materials as per the 3D CAD model @COPYRIGHT SDSCAD REVISIONS General GN1 1 96 high wall Siding-4 99 0 ft GN2 1 heated ceiling area 600.00 0.00 sq ft GN3 1 heated floor area 600.00 0.00 sq ft GN4 1 heated wall area 58.00 0.00 sq ft GN5 1 heated glass area 16.00 0.00 sq ft GN6 1 heated door area 188.00 0.00 sq ft GN 2 58 13/16 high wall Siding-4 58 0 ft Subfloor SF1 1 8'x4'x3/4" Sheet Plywood 19 0 Framing F1 1 2x4-16ft+ fir plate 300 0 ft F2 1 2x4"-91 1/2" fir stud 69 0 F3 1 2x4-16ft+ fir stud stock 80 0 ft F4 1 2x12-16ft+ header - lumber 15 0 ft F5 1 2x8-16ft+ header - lumber 50 0 ft F6 2 2x4-16ft+ fir plate 121 0 ft F 2 2x4-16ft+ fir stud stock 115 0 ft Siding S1 1 96" wide Sturdy Panel 0 ft S2 1 house wrap 820.00 0.00 sq ft S3 2 96" wide Sturdy Panel 18 0 ft Ext Trim EX1 0 4" thick - concrete grey 16.6 0.00 cu yd EX2 1 1x5-36" door threshold 1 0 EX3 1 1x4-16ft+ ext. door casing 1 0 ft EX4 1 5 in ext. door jamb 1 0 ft EX5 1 1x4-16ft+ garage door casing 54 0 ft EX6 1 5 in garage door jamb 54 0 ft EX 1 1x4-16ft+ exterior sill 5 0 ft EX8 1 1x4-16ft+ ext. window casing 13 0 ft Roofing R1 1 393" roof truss 11 0 R2 1 2x8"-16'+ ridge board - lumber 23 0 ft R3 1 2x8"-24' rafters - lumber 2 0 R4 1 2x8"-18' rafters - lumber 4 0 R5 1 2x4"-16'+ rafters - lumber 53 0 ft R6 1 ridge cap 23 0 ft R 1 Roofing Dimensional Comp. 800.00 0.00 sq ft R8 1 4x8' sheets roof sheathing 25 0 R9 1 2x8" gable fascia 69 0 ft R10 1 2x8" eave fascia 46 0 ft R11 1 metal drip edge 116 0 ft Insulation IN1 1 12x24x48" batts ceiling insulation 5 0 IN2 1 12x16x48" batts floor insulation 112 0 IN3 1 4x16x93" batts wall insulation 55 0 Flooring FL1 1 2 1/4" wide Flooring Oak-Golden 306 0 ft Wall Brd WB1 1 4'x8'x1/2" Sheet Sheetrock 25 0 WB2 1 Color Bone White 56.00 0.00 sq ft WB3 1 4'x8'x3/4" Sheet Sheetrock 18 0 WB4 2 4'x8'x1/2" Sheet Sheetrock 4 0 $0.00 $0.00 $0.00 Windows W1 1 60x36 right sliding 1 0 Doors D1 1 36x80x1 3/4L ext. 3068 19 1 0 D2 1 handle: Lever (decorative) 1 0 D3 1 handle: Exterior Handle (ext.) 1 0 D4 1 lock: Dead Bolt (interior) 1 0 D5 1 lock: Dead Bolt (exterior) 1 0 D6 1 hinge: hidden 3 0 D 1 192x84 garage 2-Panel Garge Door 1 0 D8 1 96x84 garage 2-Panel Garge Door 1 0 Int Trim T1 1 1x4-16ft+ interior casing 31 0 ft T2 1 1x4-16ft+ window apron 5 0 ft T3 1 1x4-16ft+ sill 5 0 ft T4 1 1x6-16ft+ base molding 9 0 ft Fixtures FX1 1 12W108D Garage Door Opener 2 0 Electrical E1 1 wall mount Duplex 8 0 E2 1 wall mount 220V 1 0 E3 1 wall mount Caged Lantern 3 0 E4 1 wall mount Duplex (weatherproof) - color light 1 gra 0 E5 1 wall mount Single Pole 2 0 E6 1 ceiling mount Half Dome Light - lighting grey 3 0 Total: $0.00