Terminal Blocks. BA Series. Specifications. Model BA111T BA211T BA311T BA411S



Similar documents
Terminal Blocks. BNH/BN Series. Specifications. Model BNH10W BNH15MW BNH15LW BNH30W

Terminal Blocks. Switching & Controls. Selection Guides

Circuit Breakers. NRC Series. NRC Series

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection

Solid-State Timer H3G

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

gesis IP + Heavy Duty Class I, Zone 2

AMPSEAL* Automotive Plug Connector and Header Assembly

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

Feed-through terminal block - SSK 110 KER-EX

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

INSTALLATION INSTRUCTIONS: Viewline 52 mm

Electronic overload relay EF19 and EF45

PITCHED ROOF STRUCTURES

Contractors Guide Central Inverter System Installation

XL PREMIUM OIL COOLER KIT

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Phone: Fax: Web: info@clrwtr.com

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

400 Series Buccaneer BUCCANEER POWER. bulgin

A Series 1-4 Pole Rotary Switches

RAIL FREE SOLAR ROOF MOUNT

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Relays. Relays. RH Series. RH Series General Purpose Midget Relays. Specifications

Waterproof Connectors for Outdoor Use

Block width on rail (mm) Standard block* is shown on blue background

MasterINTERFACE 39 Series - Relay interface modules

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Technicaldata General

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

TECHNICAL INFORMATION

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Connecting the Channel A

Description. Dimensions. Features. precision works better

V REG.-Nr , Z E Technical data 2-pole 4-pole Rated current 12 A 6 A SCHRACK. Accessories Miniature Relay PT. General Purpose Relays

No Phone Line II-48 System

TS93 EMR T/PT/TDE. Surface applied door closer

758 Heavy-duty Ratchet Guy Wire Cutter

AZ420 MINIATURE GENERAL PURPOSE RELAY

Directory chapter 04

Electronic overload relay EF65, EF96 and EF146

Installation Instructions For Slider Casement Air Conditioners

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Power Distribution & Terminal Blocks

PSR The compact range Description

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Safety technique. Emergency stop module BO 5988 safemaster

Installation Instructions

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Control Box Wiring For PRSstandard Tool

Electro-Pneumatic Bus Door Control Mechanism

49 Series - Relay interface modules A. Features

HERZ-Thermal Actuators

MasterINTERFACE 39 Series - Relay interface modules

2013 Wireless Video Intercom INSTALLATION GUIDE

Universal MATE-N-LOK Connectors

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

GENUINE PARTS INSTALLATION INSTRUCTIONS

Terminal Blocks 9080LBA Power Distribution Blocks Copper or Aluminum Wire

INSTALLATION INSTRUCTIONS: Viewline 85 mm

Co-location Interconnect Power Panel (CIPP) Installation Guide

KEYPAD LOCK RETROFIT KIT

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Switches & Pilot Devices

48 SERIES Relay interface modules 10 A

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Torque Transducers MEASURING ELECTRONIC

CUSTOM AUXILIARY FORWARD LIGHTING KIT

Industrial Control Power Transformers

08. SEK IDC CONNECTORS

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Assembly Instruction CAI- Connector with universal Endbell

Triac Printed Circuit Board Replacement

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

INSTALLATION INSTRUCTIONS

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Step 1. Item 6. Item 1

Model 201 Wiegand Touchpad Reader Installation Guide

Product and functional description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

RM4TG20 three-phase network control relay RM4-T - range V

MODEL HSR-007 Direct Drive Rolling Steel

The power module is Feature Number 8800-F2-901.

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

RayClic Connection System Installation Instructions

MCR1900 Media Converter 19-Slot Chassis

Transcription:

BA Series BA Series Specifications Key features: Self-contained: end plates are not required Rugged heavy-duty construction Current capacities up to 40A 3-pole units available as 1 piece (no endplates are needed) Fuse blocks with blown fuse indicators UL Recognized File No. E78117 Power Blocks Model BA111T BA11T BA311T BA411S Appearance CSA Certified File No. LR64803 Width 0.984 (5mm) 1.01 (30.5mm) 1.358 (34.5mm) 0.630 (16mm) Approvals UL, CSA UL, CSA UL, CSA UL, CSA No. of Poles 3 3 3 1 Wire Sizes to 14 AWG to 1 AWG 18 to 10 AWG 16 to 6 AWG Voltage/ UL/CSA 300V / 15A 300V / 0A 150V / 30A 600V / 40A Current JIS 600V / 16A 600V / 1A 600V / 40A 600V / 70A Terminals Size M3 M3.5 M4 M5 Type Standard screw Standard screw Standard screw Standard screw Mounting 35mm DIN rail 35mm DIN rail 35mm DIN rail 35mm DIN rail Terminal (N-m) 0.6-1.0 1.0-1.3 -.0.6-3.7 Torque (in-lbs.) 5.3-8.9 8.9-11.5-17.8 3.1-3.8 DIN Rail Stop BNL-5 BNL-5 BNL-5 BNL-5 Dust Cover BNC0 BNC0 BNC30 BNC30 PVC BNM7 BNM7 BNM7 BNM7 Marking Strip Fiberglass BNM9 BNM9 BNM9 BNM9 End clip BNM3 BNM3 BNM3 BNM3 1. BNDN1000 aluminum DIN rails are available in 1 meter lengths.. Marking strips are available in 1 meter lengths. Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Circuit Breakers Canada: 888-317-433 USA: 800-6-433 907

BA Series Switches & Pilot Lights Fuse Blocks Specifications, continued Model BAF111SU BAF111SNU BAF111SDU Appearance Signaling Lights Relays & Sockets Timers Width 0.630 (16mm) 0.630 (16mm) 0.630 (16mm) Blown Fuse Indicator None Neon (100 to 300V AC) LED (4V DC) Approvals UL, CSA UL, CSA UL, CSA No. of Poles 1 1 1 Wire Sizes 18 to 10 AWG 18 to 10 AWG 18 to 10 AWG Current 10A maximum 10A maximum 10A maximum Terminals Size M4 M4 M4 Type Standard screw Standard screw Standard screw Mounting 35mm DIN rail 35mm DIN rail 35mm DIN rail Terminal (N-m) -.0 -.0 -.0 Torque (in-lbs.) - 17.8-17.8-17.8 DIN Rail Stop BNL-5 BNL-5 BNL-5 Dust Cover Marking Strip BNM7 BNM7 BNM7 Applicable Fuse Size 1/4 x 1-1/4 (6.35 x 31.8mm) 1/4 x 1-1/4 (6.35 x 31.8mm) 1/4 x 1-1/4 (6.35 x 31.8mm) Circuit Breakers Contactors 908 www.idec.com

BA Series BA111T BA11T BA311T BA411S BAF111 -M4 Screw.8.8 0.0 0.0.5 6-M3.5 Screw 6-M3 Screw -M5 Screw -M5 Screw 5 38.5 7.9 7.9 Dust Cover 6.7 30.5 9.8 9.8 16 16 16 10 8.5 38.5 Dust Cover 50 Dust Cover 48 50 Dust Cover 48 63 36 Diagrams When using BAA/BAP: 3 When using BAA/BAP: 3 When using BAA/BAP: 37.5 When using BAA/BAP: 37.5 Diagrams When using BAA/BAP: 49 Dimensions ø3. min. 6.6 max. 5 max. 3.3 min. ø3.6 min. 8.4 max. 5 max. 4 min. ø4. min. 9.4 max. 6 max. 4.5 min. ø5. min. 1.8 max. 6.5 max. 4.5 min. ø4. min. 10 max. 5. max. 4.5 min. Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Circuit Breakers Canada: 888-317-433 USA: 800-6-433 909

Accessories Timers Relays & Sockets Signaling Lights Switches & Pilot Lights Accessories Part Numbers: End Plates, DIN Rail Stops, Stand-Offs, DIN Rail and Dust Covers Item Appearance Use with Remarks End Plates DIN Rail Stops BNH10W BNH15MW BNH15LW BNH30W BNF10SW BNF10NW BNF10DW BNH50W BN75W BN150W BNH10W BNH15MW BNH15LW BNH30W BNH50W BNF10SW BNF10NW BNF10DW BA111T BA11T BA311T BA411S BAF111SU BAF111SDU BN75W BN150W BNE15W BNE30W BNE0 BNE50W BNE75W BNE150W BNDE15W BNL5 (small) BNL6 (medium) 1. DIN rail stops prevent side-to-side movement.. The BNL-5 width is 0.375 (9mm). 1. DIN rail stops prevent side-to-side movement.. The BNL-6 width is 0.375 (9mm). 3. To firmly stabilize these higher profile terminal blocks, the BNL-6 has a higher profile than the BNL-5. Contactors BN00NW# BN400NW# BNL8 (large) 1. DIN rail stops prevent side-to-side movement.. The BNL-8 width is 0.571 (14.5mm). 3. # = number of poles. DIN Rail Stand-Offs All series BNS3 BNS4 6 (37mm) height 3.03 (77mm) height DIN Rail All series BNDN1000 (length 39.37 (1mm) 1. For calculating the rail lengths required, see the instructions on page 876.. The DIN rail material is aluminum. Circuit Breakers Surface Mount Bracket (dual-deck) BNDL Used to surface mount dual-deck terminal blocks. (BNDL). 910 www.idec.com

Accessories Accessories, continued Part Numbers: Rods, Nuts, Marking Strips, Dust Covers, and Jumpers Item Appearance Use with Remarks Dust Covers BNH10W BNH15MW BNH15LW BNH30W BNH50W BNC30 BNC30 The overall length is 39.37 (1,000mm). The material is polycarbonate (UL94-V). BN75W BNC40 BN150W BNC50 BN00 BAC80 BN400 BNC1000 Marking Strips Marking Strip Fastener Ring Terminal Jumpers Fork Terminal Jumpers M4 Thread Rod Connecting Nuts Terminal Block Removal Tool For accessory dimensions, see page 91. All series All series BNH10W BNH15MW BNH15LW BNH30W BNH50W BNH10W BNH15MW BNH15LW BNH30W BNR1 BNR BNM7 BNM9 BNM3 BNJ16 BNJ6W BNJ46 BNJ56 BNJ6W BNJ6 BNJ16F BNJ6FW BNJ46F BNJ56F BNJ6FW BNR1 (65mm) BNR (500mm) BNN1 BND Material: polyvinyl chloride (PVC) Strip dimensions are 0.37 x39 (9.5 x 1,000mm). Material: fiberglass Strip dimensions are 0.37 x39 (9.5 x 1,000mm). Used to prevent marking strips from sliding off terminal block. Jumpers come standard with 6 points (except BNJ6). Note: insulated jumpers available - add B to end of part number. For example, BNJ6WB. 1. Rod and connecting nuts are used to mount dual-decks collectively.. Each connecting nut set includes 1 hex connecting nut and 1 round connecting nut. 3. The BNR1 rod dimensions are 0.07 x 10.43 (0.7 x 65mm). 4. The BNR rod dimen-sions are 0.07 x 19.69 (0.7 x 500mm). Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Circuit Breakers Canada: 888-317-433 USA: 800-6-433 911

Accessories Switches & Pilot Lights Dimensions: DIN Rail Dimensions Diagrams Signaling Lights BNDN1000 Relays & Sockets Dimensions: Jumpers BNH Series BNJ16 BNJ16F (fork) BNJ6W BNJ6FW (fork) BNJ16 ø3.7 11 4 Diagrams BNJ6W Circuit Breakers Timers Contactors 5.7 7 35 (6-pole) BNJ16F (fork) R1.85 4 11 3.7 5.7 3.7 7 35 (6-pole) 4.5 11 6.4 ø3.7 8 40 (6-pole) BNJ6FW (fork) R1.85 4.5 11 4.5 6.4 40 (6-pole) 8 3.7 BNJ46 BNJ46F (fork) BNJ56 BNJ56F (fork) 5.5 11 BNJ46 10.5 8. 5.5 (6-pole) ø4..8 BNJ46F (fork) 4.5 5.5 11 8. R.1 10.5 4. 5.5 (6-pole).8 6 9.5 BNJ56 60 (6-pole) 1 9.3 ø4. 1.7 BNJ56W (fork) 60 (6-pole) 1 4. 9.3 R.1 6 9.5 5.8 1.7 BNJ6 hole BNJ6 Thickness + mm (0.0315 ) 91 www.idec.com

Accessories Dimensions, continued Dimensions, DIN Rail Stops and Stand-offs Dimensions BNL-6 45 9 BNL-6 shown, BNL-5 same except without back crossbar BNL-8 46 14.4 30 6 BNDL 38 BNS3 BNS4 15 15 36.7 15 8.6 6 5 76.7 15 8 6.6 30 -ø5. -M5 1.5 BNS3 5 30 -ø5. -M5 BNS4 1.5 54 1.5 54 1.5 Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Circuit Breakers Canada: 888-317-433 USA: 800-6-433 9

Accessories Switches & Pilot Lights Dimensions, continued Dimensions: End Plates Dimensions Dimensions 38 53 Signaling Lights BNE15W BNE75W 5 5 Relays & Sockets 63 74 BNE0 BNE150W Timers 3 38 5 6 Contactors BNE30W BNDE15W 5 48 BNE50W Circuit Breakers 5 914 www.idec.com

Instructions Wiring Touch-Down : BNH Series Instructions Instructions Step 1 Step Step 3 Step 4 Step 1. Insert the wire (or crimping terminal) into the terminal block with the terminal screws in the open position. (Use of crimping terminals is optional.) Step. Push the terminal screw down to hold the wire in place. Step 3. Hold the terminal screw down, and tighten with a screwdriver. Step 4. To remove the wire, loosen the terminal screw and pull up until wire is released. Installation and Removal of Instructions Step 1. Slide the terminal blocks onto the DIN rail from one end. Step. Use BNL5 or BNL6 end clips to secure the terminal block row and to prevent side-to-side movement. BNH10W, BNH15MW, BNH15LW, and BNH30W can be installed from the middle of a DIN rail. Step 3. To install, place the terminal block on top of the DIN rail and push down until both edges of the terminal block snap onto the DIN rail. Step 4. To remove the terminal block, use the BND removal tool as shown on the right. Mounting Double-Deck Instructions DIN Rail Mount: Step 1. First install the end plate. Then mount the terminal blocks onto the DIN rail. Step. To prevent side-to-side movement on the DIN rail, use the BNL-8 mounting clip at both ends of the rail. Panel Mount: Step 1. Assemble a row of terminal blocks with end plates on exposed end(s). Step. Use BNDL mounting clips at both ends of a row. Step 3. With the two holes of the mounting clip aligned with the terminal block holes, insert a connecting rod through each hole. Step 4. Secure the ends of the connecting rods with the connecting nuts, as shown below. Connecting Nut (hex) End Plate Mounting Clip Appearance Appearance Terminal Block Connecting Rod Removal Tool BND Connecting Nut (round) Mounting Clip Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Circuit Breakers 800-6-IDEC (433) USA & Canada 915

Instructions Switches & Pilot Lights Signaling Lights Relays & Sockets Calculating DIN Rail Lengths Instructions Step 1. Add widths of all terminal blocks (reference pages 864 through 869). Step. Add the endplate thickness (usually only one). Step 3. Add the DIN rail stop widths (usually two are used). Step 4. Round to the nearest (50mm) increment to allow for DIN rail hole spacing. Step 5. Add 1 (5mm) to ensure 0.5 (1.5mm) of clearance at each end of the DIN rail. DIN Rail Stop Dimensions Width BN150W BN100W BN75W BN50W (BNH50W) BN40W (BNH40W) BN30W (BNH30W) BN15LWT (BNH15LWT) BN15LW (BNH15LW) BN15MWT (BNH15MWT) BN15MW (BNH15MW) BN10W (BNH10W) 1.5 8.5 6.7 6 9.6 7 8 1 10.5 1 14 15.5 17 0 3 6 3 6 BNE150W BNT0 BNF10S BNE0 5 15 15 3 Appearance 33 BN00BW (BN00NW) 78 (P) 115 (3P) 15 (4P) L (Mounting Centers) (Rail Length) L 1 40 BN300BW (BN300NW) 9 (P) 6 (3P) 180 (4P) 5 BN400BW (BN400NW) 119 (P) 176 (3P) 33 (4P) BNL-5.374 (9mm) BNL-6.374 (9mm) BNL-8.571 (14.5mm) Circuit Breakers Contactors Timers Torque Specifications and Applicable Connector Sizes Screw Size M3 M3.5 M4 M5 M6 M8 M10 M1 Diagram (N-m) 0.6 to 1.0 1.0 to 1.3 to.0.6 to 3.7 3.9 to 5.4 10 to.5 1 to 8 38 to 49 Torque (kgf-cm) 6.1 to 10. 10. to.3 14.3 to 0.4 6.5 to 37.7 39.8 to 55.1 10 to 8 14 to 86 388 to 500 Dimension A Dimension B Dimension C Dimension D 0.57 (6.6mm) 0.19 (3.3mm) 0.195 (5mm) Ø 0.15 (3.mm) 0.33 (8.5mm) 0.156 (4mm) 0.195 (5mm) Ø 0.140 (3.6mm) 0.371 (9.5mm) 0.176 (4.5mm) 0.34 (6mm) Ø 0.164 (4.mm) 0.499 (1.8mm) 0.176 (4.5mm) 0.54 (6.5mm) Ø 0.03 (5.mm) 0.655 (16.8mm) 0.34 (6mm) 0.33 (8.5mm) Ø 0.4 (6.mm) Rated Current Applicable Wire Rated at 60 C Applicable Wire Rated at 60 C AWG (0.3mm ) 3A 6 (14mm ) 50A 0 AWG (0.5mm ) 5A 4 (mm ) 75A 18 AWG (0.75mm ) 7A 0 (38mm ) 100A 16 AWG (1.5mm ) 10A 00 (60mm ) 150A 14 AWG (mm ) 15A 0000 (100mm ) 00A 1 (3.5mm ) 0A 300mcm (150mm ) 300A 10 (5.5mm ) 30A 400mcm (00mm ) 350A 90 (.8mm) 0.31 (8mm) 0.49 (11mm) Ø 0.33 (8.5mm) UL/CSA ratings are specified. The current carrying capacity depends on the rating of the wire used, as shown. 1.79 (3.8mm) 0.49 (11mm) 0.64 (16mm) Ø 0.410 (10.5mm) 1.981 (5mm) 0.546 (14mm) 1.014 (6mm) Ø 0.488 (1.5mm) 916 www.idec.com