Minor losses include head losses through/past hydrants, couplers, valves,



Similar documents
= water horsepower WHP brake horsepower QH WHP = (222) ( 33,000 ft-lbs/min-hp)( gal/ft ) 1 HP=0.746 kw

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

Selection Of Centrifugal Pumping Equipment 1

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Pressure drop in pipes...

Selection and Use of Water Meters for Irrigation Water Measurement 1

C. starting positive displacement pumps with the discharge valve closed.

Pacific Pump and Power

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

Chapter 3.5: Fans and Blowers

Theory, Application, and Sizing of Air Valves

Centrifugal Fans and Pumps are sized to meet the maximum

Practice Problems on Pumps. Answer(s): Q 2 = 1850 gpm H 2 = 41.7 ft W = 24.1 hp. C. Wassgren, Purdue University Page 1 of 16 Last Updated: 2010 Oct 29

Lecture 12 Center Pivot Design & Operation. I. Introduction and General Comments

Chapter 8: Flow in Pipes

Module 9: Basics of Pumps and Hydraulics Instructor Guide

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

1. Sprinkler selection 2. Design of the system layout 3. Design of the laterals 4. Design of the mainline 5. Pump and power unit selection

SIZING OF WATER PIPING SYSTEM

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Water hammering in fire fighting installation

Flow Measurement Options for Pipeline and Open Channel Flow

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

WATER MEASUREMENT USING TWO INCH (50 mm) DRAIN TESTS

measurement, but almost any pipe elbow can be calibrated Elbow meters are not as potentially accurate as venturi,

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Pumps SELECTION OF A PUMP

Lecture 24 Flumes & Channel Transitions. I. General Characteristics of Flumes. Flumes are often used:

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

Flashing and Cavitation

Design of Sewage Pumping Stations by John Zoeller, PE, CEO/President

APPENDIX A RECOMMENDED RULES FOR SIZING THE WATER SUPPLY SYSTEM

Experiment # 3: Pipe Flow

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Unit 24: Applications of Pneumatics and Hydraulics

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers.

Lecture 22 Example Culvert Design Much of the following is based on the USBR technical publication Design of Small Canal Structures (1978)

Hydraulic losses in pipes

A BRIEF INTRODUCTION TO CENTRIFUGAL PUMPS

1. Carry water under the canal 2. Carry water over the canal 3. Carry water into the canal

Automatic Sprinkler System Calculations

Section 4 Page 2. Flow in Pipes

Pipe Flow-Friction Factor Calculations with Excel

FLUID MECHANICS. TUTORIAL No.7 FLUID FORCES. When you have completed this tutorial you should be able to. Solve forces due to pressure difference.

Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs

Design and testing of a high flow coefficient mixed flow impeller

SIZING AND CAPACITIES OF GAS PIPING

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

Air Eliminators and Combination Air Eliminators Strainers

PEERLESS PUMP COMPANY SYSTEM ANALYSIS FOR PUMPING EQUIPMENT SELECTION

Experiment 3 Pipe Friction

NFPA31FuelOilPiping 1 Revised

Unit 24: Applications of Pneumatics and Hydraulics

Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.

Sta-Rite Industries Basic Training Manual

Anti-Cavitation Trim. Eliminates cavitation damage Reduces noise Preserves valve and surrounding pipe systems. singervalve.com

Chapter 2 Pump Types and Performance Data

du u U 0 U dy y b 0 b

Water Supply. Simulation of Water Distribution Networks. Mohammad N. Almasri. Optimal Design of Water Distribution Networks Mohammad N.

Irrigation Pumping Plant

TABLE OF CONTENT

Broad Crested Weirs. I. Introduction

CO MPa (abs) 20 C

Toms River Fire Academy

Chokes. Types Reasons Basics of Operations Application

ACOUSTICS IN PUMPING SYSTEMS

L r = L m /L p. L r = L p /L m

HEAVY OIL FLOW MEASUREMENT CHALLENGES

CHAPTER ONE Fluid Fundamentals

Centrifugal Pump Handbook

CHAPTER 2 HYDRAULICS OF SEWERS

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

Nozzle Loads, Piping Stresses, and the Effect of Piping on Equipment

SIZING AND CAPACITIES OF GAS PIPING

INNOVATION AND COST EFFECTIVE APPROACH TO POTABLE WATER PIPE REPLACEMENT STRATEGICALLY FOCUSED ON DISTRIBUTION SYSTEM WATER QUALITY IMPROVEMENT By

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

Control ball valves for severe services. Author: Michele Ferrante, PARCOL S.p.A., Italy

The conditions below apply to the curves shown on the following pages.

Agricultural Pumping Efficiency Improvements

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

CHAPTER 3 STORM DRAINAGE SYSTEMS

FLUID FLOW Introduction General Description

ME 305 Fluid Mechanics I. Part 8 Viscous Flow in Pipes and Ducts

SJT / SJM / SJP Large Vertical Pumps

FUNDAMENTALS OF GAS TURBINE METERS John Gorham Sensus Metering Systems 805 Liberty Blvd. DuBois, PA 15801

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

FLUID FLOW STREAMLINE LAMINAR FLOW TURBULENT FLOW REYNOLDS NUMBER

Green Thread Product Data

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

ABB Flowmeters Review of industrial processing flowmeters

Open Channel Diffusers

Springdale Fire Department Backup Driver Certification Program. Behavioral Objectives

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Transcription:

Lecture 10 Minor Losses & Pressure Requirements I. Minor Losses Minor (or fitting, or local ) hydraulic losses along pipes can often be estimated as a function of the velocity head of the water within the particular pipe section: V hml = Kr (08) g w here h ml is the minor loss (m or ft); V is the mean flow velocity, Q/A (m/s or fps); g is the ratio of weight to mass (9.81 m/s or 3. ft/s ); and K r is a coefficient, dependent on the type of fitting (valve, bend, transition, constriction, etc.) Minor losses include head losses through/past hydrants, couplers, valves, pipe elbows, tees and other fittings (see Tables 11.1 and 11.) For example, there is some loss when water flows through a hydrant, but also some los s when water flows in a pipe past the location of a closed hydrant K r = 0.3 to 0.6 for flow in a pipeline going past a closed hydrant, whereby the velocity in the pipeline is used to compute h ml K r = 0.4 to 0.8 for flow in a pipeline going past an open hydrant; again, the velocity in the pipeline is used to compute h ml K r = 6.0 to 8.0 for flow from a pipeline through a completely open hydrant. In this case, compute h ml using the velocity of the flow through the lateral fitting on the hydrant, not the flow in the source pipeline. For flow through a partially open hydrant, K r increases beyond the 6.0 to 8.0 magnitude, and the flow rate decreases correspondingly (but not linearly) In using Tables 11.1 and 11. for hydrants, the nominal diameter (3, 4, 5, and 6 inches) is the diameter of the hydrant and riser pipe, not the diameter of the source pipeline Use the diameter of the hydrant for K r and for computing V r. However, for line flow past a hydrant, use the velocity in the source pipeline, as indicated above. Always use the largest velocity along the path which the water travels this may be either upstream or downstream of the fitting Do not consider velocities along paths through which the water does not flow In Table 11., for a sudden contraction, K r should be defined as: Sprinkle & Trickle Irrigation Lectures Page 111 Merkley & Allen

r ( ) r K = 0.7 1 D (09) where D r is the ratio of the small to large inside diameters (D small /D large ) Allen (1991) proposed a regression equation for gradual contractions and expansions using data from the Handbook of Hydraulics (Brater & King 1976): where K f is defined as: ( ) K = K 1 D (10) r f r ( ) Kf = 0.7 cos(f) cos(f) 3.cos(f) 3.3 + 0.77 (11) and f is the angle of the expansion or contraction in the pipe walls (degrees or radians), where f 0 For straight sides (no expansion or contraction), f = 0 (whereby K f = 0.03) For an abrupt change in pipe diameter (no transition), f = 90 (whereby K f = 0.7) The above regression equation for K f gives approximate values for approximate measured data, some of which has been disputed In any case, the true minor head loss depends on more than just the angle of the transition Expansion Contraction For a sudden (abrupt) expansion, the head loss can also be approximated as a function of the difference of the mean flow velocities upstream and downstream: Merkley & Allen Page 11 Sprinkle & Trickle Irrigation Lectures

h ml = ( V V ) us g ds (1) An extreme (albeit unrealistic) case is for V ds = 0 and h ml = Vus /g (total conversion of velocity head) Various other equations (besides those given above) for estimating head loss in pipe expansions and contractions have been proposed and used by researchers and engineers Minor Loss Example A mainline with an open lateral hydrant valve has a diameter of 00 mm ID upstream of the hydrant, and 150 mm downstream of the hydrant The diameter of the hydrant opening to the lateral is 75 mm Q upstream = 70 lps and Q lateral = 16 lps The pressure in the mainline upstream of the hydrant is 300 kpa The mean flow velocities are: V V 3 0.070 m / s = =.3m/s π(0.00 m) 4 00 0.070 0.016 m / s = = 3.06m/s π(0.150 m) 4 150 3 (13) (14) Sprinkle & Trickle Irrigation Lectures Page 113 Merkley & Allen 3 0.016 m / s Vhydrant = = 3.6m/s (15) π(0.075 m) 4

Note that V 00 and V 150 are both above the normal design limit of about m/s The head loss past the open hydrant is based on the higher of the upstream and downstream velocities, which in this example is 3.06 m/s From Table 11.1, the K r for flow past the open hydrant (line flow; 6 mainline) is 0.5; thus, ( ) (3.06) hml = 0.5 = 0.4m (16) past (9.81) The head loss due to the contraction from 00 mm to 150 mm diameter (at the hydrant) depends on the transition If it were an abrupt transition, then: 150 Kr = 0.7 1 = 0.13 00 (17) And, if it were a 45 transition, K f = 0.67, also giving a K r of 0.13 Then, the head loss is: (3.06) hml = 0.13 = 0.06m (18) contraction (9.81) ( ) Thus, the total minor loss in the mainline in the vicinity of the open hydrant is about 0.4 + 0.06 = 0.30 m (0.43 psi). The loss through the hydrant hydrant): ( ) h ml through is determined by taking K r = 8.0 (Table 11.1; 3 (3.6) = 8.0 = 5.3m (19) (9.81) This is a high loss through the hydrant (about 7.6 psi), so it may be advisable to use a larger diameter hydrant. The pressure in the mainline downstream of the hydrant is (9.81 kpa/m): P V = P γ( hml ) past +γ 150 00 00 V150 (.3) (3.06) P150 = 300 (9.81)(0.4) + 9.81 = 95kPa (9.81) g (0) Merkley & Allen Page 114 Sprinkle & Trickle Irrigation Lectures

II. Total Dynamic Head The Total Dynamic Head (TDH) is the head that the pump feels or sees while working, and is calculated to determine the pump requirements It includes the elevation that the water must be lifted from the source (not necessarily from the pump elevation itself) to the outlet, the losses due to friction, the pressure requirement at the outlet, and possibly the velocity head in the pipeline For a sprinkler system, the value of TDH depends on the positions of the laterals, so that it can change with each set. Pump selection is usually made for the critical or extreme lateral positions, that is, for the worst case scenario. Keller & Bliesner recommend the addition of a miscellaneous loss term, equal to 0% of the sum of all friction losses. This accounts for: 1. Uncertainty in the K r values (minor losses). Uncertainty in the Hazen-Williams C values 3. Aging of pipes (increase in losses) 4. Wear of pump impellers and casings Losses in connectors or hoses from the mainline to laterals, if present, must also be taken into account when determining the TDH See Example Calculation 11. in the textbook The next two lectures will provide more information about TDH and pumps III. Th e System Curve The system curve determines the relationship between TDH and flow rate This curve is approximately parabolic, but can take more complex shapes Note that head losses in pipe systems are approximately proportional to the square of the flow rate (Q or V ) For the Hazen-Williams equation, these losses are actually proportional to Q 1.85 or V 1.85 For standard, non-fcn, sprinkler nozzles, the head at the sprinkler is also proportional to Q Sprinkler systems can have a different system curve for each position of the lateral(s) Defining the system curve, or the critical system curve, is important for pump selection because it determines, in part, the operating point (TDH and Q) for the system Sprinkle & Trickle Irrigation Lectures Page 115 Merkley & Allen

IV. Valving a Pump A throttle valve may be required at a pump: (a) Filling of the system s pipes The head is low, and the flow rate is high Pump efficiency is low and power requirements may be higher Water hammer damage can result as the system fills Air vents and other appurtenances can be blown off For the above reasons, it is advisable to fill the system slowly (b) To avoid cavitation, which damages the pump, pipes and appurtenances (c) To control the TDH as the sprinklers are moved to different sets Throttle valves can be automatic or manual Pressure Requirements & Pumps I. Types of Pumps 1. Positive Displacement Piston pumps Rotary (gear) pumps Extruding (flexible tube) pumps. Variable Displacement Centrifugal pumps Injector pumps Jet pumps The above lists of pump types are not exhaustive Positive displacement pumps have a discharge that is nearly independent of the downstream (resistive) pressure. That is, they produce a flow rate that is relatively independent of the total dynamic head, TDH Merkley & Allen Page 116 Sprinkle & Trickle Irrigation Lectures

Positive Displacement Pumps Axial-Flow Impeller Closed Centrifugal Pump Impeller Jet Pump Sprinkle & Trickle Irrigation Lectures Page 117 Merkley & Allen

But, with positive displacement pumps, the required pumping energy is a linear function of the pressure Positive displacement pumps can be used with thick, viscous liquids. They are not commonly used in irrigation and drainage, except for the injection of chemicals into pipes and for sprayers Piston-type pumps can develop high heads at low flow rates Air injection, or jet pumps are typically used in some types of well drilling operations. The air bubbles effectively reduce the liquid density and this assists in bringing the drillings up out of the well. Needs a large capacity air compressor. Homologous pumps are geometrically similar pumps, but of different sizes II. Centrifugal Pumps 1. Volute Case This is the most common type of irrigation and drainage pump (excluding deep well pumps). Produce relatively high flow rates at low pressures.. Diffuser (Turbine) The most common type for deep wells. Designed to lift water to high heads, typically using multiple identical stages in series, stacked up on top of each other. 3. Mixed Flow Uses a combination of centrifugal and axial flow action. For high capacity at low heads. 4. Axial Flow Water flows along the axis of impeller rotation, like a boat propeller. Appropriate for high discharge under very low lift (head). An example is the pumping plant on the west side of the Great Salt Lake. 5. Regenerative The characteristics of these pumps are those of a combination of centrifugal and rotary, or gear, pumps. Shut-off head is well-defined, but efficiency is relatively low. Not used in irrigation and drainage. In general, larger pumps have higher maximum efficiencies (they are more expensive, and more effort is given toward making them more efficient) Impellers can be open, semi-open, or closed. Open impellers are usually better at passing solids in the pumped liquid, but they are not as strong as closed impellers Double suction inlet pumps take water in from both sides and can operate without axial thrust Merkley & Allen Page 118 Sprinkle & Trickle Irrigation Lectures

Closed Impeller Semi-Open Impeller Open Impeller Characteristic Curve The pump characteristic curve defines the relationship between total dynamic head, TDH, and discharge, Q The characteristic curve is unique for a given pump design, impeller diameter, and pump speed The characteristic curve has nothing to do with the system in which the pump operates The shut-off head is the TDH value when Q is zero (but the pump is still operating) The shut-off head can exceed the recommended operating pressure, or even the bursting pressure, especially with some thin-wall plastic pipes Total Dynamic Head, TDH Shut-Off Head Efficiency Characterisic Curve Power 0 0 Flow Rate, Q Sprinkle & Trickle Irrigation Lectures Page 119 Merkley & Allen

III. Centrifugal Pumps in Parallel Pumps in PARALLEL means that the total flow is divided into two or more pumps Typical installations are for a single inlet pipe, branched into two pumps, with the outlets from the pumps converging to a single discharge pipe If only one of the pumps operates, some type of valve may be ic He ad, TDH Total Dynam 0 0 Flow Rate, Q required so that flow does not flow backwards through the idle pump Flow rate is additive in this case pump 1 One Pump Two in Par allel pump Two Pumps in Parallel IV. Centrifugal Pumps in Series Pumps in SERIES means that the total flow passes through each of two or more pumps in line Typical installations are for increasing pressure, such as with a booster pump Head is additive in this case Merkley & Allen Page 10 Sprinkle & Trickle Irrigation Lectures

Total Dynam ic Hea d, TDH Two in Series One Pump 0 0 Flow Rate, Q It is common for turbine (well) pumps to operate in series For centrifugal pumps, it is necessary to exercise caution when installing in series because the efficiency can be adversely affected May need straightening vanes between pumps to reduce swirling Note that the downstream pump could cause negative pressure at the outlet of the US pump, which can be a problem pump 1 pump Two Pumps in Series Sprinkle & Trickle Irrigation Lectures Page 11 Merkley & Allen

Merkley & Allen Page 1 Sprinkle & Trickle Irrigation Lectures