TRL-onlineTOC MONITOR



Similar documents
TRL-onlineTOC Monitor is designed for monitoring carbon content in

Online Infrared Flue Gas Analyzer Gasboard 3000

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Power consumption (kw)

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Back-UPS Pro 1300/1500 Installation and Operation

ORGANIC SAMPLE PREPARATION

Multi-Range Programmable DC Power Supplies 9115 Series

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

2.24. Pump Controller 704. Data Sheet

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

ADU 5. Automatic Distillation Unit

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Centro-Matic Automatic Lubrication Systems System Controls

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Sigma Control PC INSIDE. 97 psi 187 F R on load

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Temperature & Humidity SMS Alert Controller

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Product Information Sheet UH36 Hi Pot Tester

Dash 18X / Dash 18 Data Acquisition Recorder

Transmitter Interface Program

Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2

Dash 8Xe / Dash 8X Data Acquisition Recorder

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

OT 40L / 90L. Laboratory Steam Sterilizers

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Product Information Sheet UH28CS-12kV Hi Pot Tester

Hazards associated with the gas system and how to mitigate them

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Analytical Instruments Smart Analyzer 90 Type SMA

FMA-80 Fluorescence Mercury Analyzer

COMBIMASS. Technical Data COMBIMASS eco-bio +

Thermostat with display

Designed for multi-injector endurance testing, the

TENDER DOCUMENT PURCHASING EQUIPMENT FOR PEPTIDE SYNTHESIS

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Duct Humidity Transmitter

CyTOF2 Sample Acquisition: Super Sampler* (CyTOF software version )

Advanced Solutions for Gas Monitoring

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

PIEZOMETER AIRFLOW MEASURING RING

TC-9102 Series Surface Mount Temperature Controllers

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Multi-Range Programmable DC Power Supplies 9115 Series

The Ambient Air Monitoring System

Mass Flow Meter Product Guide

How To Control A Medical Device With A Pc System

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

FTA1100-J DIESEL ENGINE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Mitos P-Pump. product datasheet

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

CHROMOCTANE O N LINE ANALYZER

Notice. Reverse engineering and disassembly are prohibited.

Rotary screw compressors kw 5,5 7, , bar MODULO

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

EnAlgae SOP: Biogas analysis

BHS CANDLE FILTER APPLICATIONS FOR CLARIFICATION / RECOVERY OF SOLIDS FROM CHEMICAL SLURRIES

aseries DVR04/DVR08 DIGITAL VIDEO RECORDER Quick Operations Guide

On-line Dissolved Gas Analysis

Vacuum drying oven for non-flammable solvents

IFC 070 Technical Datasheet

Installation and Operation Back-UPS 1250, 1300, 1500

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Marine after-treatment from STT Emtec AB

ICON Analyzer. Dedicated online photometer for water and wastewater analysis

PDS-750-TR Touring Power Supply Operator s Manual

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Instruction Manual. T3111 T3111L T3111P T3111Ex

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

KNC Model 3666 Automatic Pressure Calibration System

Everything you need for protection scheme testing

Toxicity. Toxicity monitoring technologies for on line, on location and the laboratory

Water for Injection (WFI) and Pure Steam Production in a Lean Manufacturing Environment. Larry Zanko Project Manager STERIS Corporation

Coriolis Flow meters. Product family introduction Principle of operation Product review Applications Key product features

Application Requirement

WEATHER STATION FOR SOLAR FARM MONITORING

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

Ammonia Detection System Codes and Design Specifications

Adsorption air dryers ADS 1 215

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

ETC -SV. Class 0 oil-free compressed air through catalysis

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Powerline 500 WiFi Access Point (XWN5001) Installation Guide

Thermo Scientific ConFlo IV Universal Interface

Wireless Data Logger Monitoring Systems

Transcription:

TRL-onlineTOC MONITOR TRL-onlineTOC Monitor operates on well accepted HTC (high temperature combustion) technology. It is a self sufficient system that requires no external side unit to operate. It is used for monitoring water quality, flowing in or through a pipe or channel. Sampling from sea, lake and river is possible. Different configurations are available for variety of applications and needs. As TRL-onlineTOC Monitor is in compliance with universal standards, it can be used for reporting to regulatory bodies and for strict audits. All data generated throughout a monitoring period is logged, saved and is readily available when required.

Other products within TRLInstruments range: > Laboratory TOC Analyzers for soil, solid waste, biomass, other solid and sludge samples > Custom designed systems requiring control of flow, temperature, composition and presure of one or more streams > Gas blenders for up to 8 streams > Systems for vapor generation of water or organic solvents > Temperature controlled heated lines, heated/cooled chambers > Systems for gas conditioning, requiring heating, cooling, drying, pumping, mist separation > Custom designed NDIR, MS, TCD based online gas analyzer systems > On-line SynGas and Landfil Gas analyzers > On-line, combined CO2, CO, CH4, O2 monitors > Experimental set-ups for reaction studies: PFR and CSTR for student laboratories Please see our web site for more information and sample systems www.terralab.com.tr www.trlinstruments.com Cetin Emec Bulvari, 1328 Sokak No:14/9 A.Ovecler ANKARA 06460 TURKIYE T: +90 312 472 73 96 F: +90 312 472 73 98 E: info@terralab.com.tr oltoc-07.13-01/en TRL Instruments is the registered trademark of Terralab Laboratory Equipment Manufacturing & Trading Inc.,Co. (TERRALAB in short) TERRALAB is a ISO 9001:2008 certified company and has got service quality accreditation according to EN 12426 and EN 13201

Specifications Analysis method Measured parameters Furnace design Range Accuracy (with one outlier) Repeatability (with one outlier) Minimum detection limit Suspended solids Sample and liquid delivery Response time Analysis cycle time Sample inlet pressure Air flow rate High temperature combustion TC and TOC standard; IC and TN optional Patented two zone furnace system to assure complete combustion of all organic carbon and nitrogen in the sample including in the particulates; one operating at 600-1000 C(adjustable) and the next at 400-600 C(adjustable) From 0-5 up to 0-5,000mg/L TOC, automatically adjusted, without dilution; optional range up to 0-50,000mg/L TOC, automatically adjusted, with auto-dilution; optional 0-50mg/L range only; for drinking and pharmaceutical water ± 5 % of range at ranges less than 1000mg/L ± 2 % of reading at ranges over 1000mg/L ± 5 % of range at ranges less than 1000mg/L ± 2 % of reading at ranges over 1000mg/L < 0.25mg/L for 0-5mg/L TC/TOC range; < 0.05mg/L for 0-5mg/L only configuration Up to 1200um diameter particles are flowing through the tubing without blokage; magnetic stirring in the sparger is standard 6 peristaltic pumps; common for acid, sample, DI water(1 pump); waste(2 pumps), internal delivery(3 pumps) 8 minutes for 5,000 mg/l range configuration Depends on wash cycle numbers; nominally 20 minutes Atmospheric to 1 barg Sample temperature range 5 C to 45 C Operating temperature range 5 C to 40 C Analog outputs Digital outputs Relay contacts Software functions Safety and Reliability Lighting on the front panel Auto-stand-by Power Connections Carrier Gas Nominally 200mL/min, adjustable Standard methods 5310B, EPA 415.1 Enclosure Dimensions Weight Configurations Multi-point monitoring 4-20mA analog TC/TOC concentration output along with 4-20mA analog range identification output in TC/TOC standad configuration; separate 4-20mA outputs for IC and TN in IC and TN options Date(dd/mm/yy), Time(hh/mm), Sample type: calibration standard/validation sample/line sample, Mode (TC or TOC in standard configuration; IC and TN optional), Concentration, Status: normal/ warning, error message and stand-by, Under-limit or Over-limit message Over-upper and below-lower limit alarms as relay contacts System diagnostics, data storage, calibration function and calibration file storage; auto-ranging; validation once every user-settable run cycles; design of an analytical cycles as to include as many DI wash and sample wash runs as required; maintenance cycle management and warning of replacement parts based on run cycles; automated validation run in case of unexpected results; generation of warning messages Continuous control of sample, acid and DI water flows, liquid leakage, furnaces temperature, air flowrate and air leakage Green light: system is running and everthing is well in order Yellow light: there is something to deal with, however running properly Red light: there is something wrong and system is at standby In case of following conditions, the system is down and taken into stand-by: Acid bottle empty Sample-acid-DI water leakage Air leakage Furnace temperature failure Power up after power cut off 115/230 VAC 50/60 Hz (switch selectable); 1600VA 1/8 Swagelock sample in, DI water in, Acid in, 1/8 swagelock compressed air in, ¼ quick-fit Drain out, 1/8 Swagelock Gas vent standard; Optional according to user specifications Hydrocarbon and CO2 free air at 2-6 bar, al nomintotal consumption 800mL/min, adjustable NEMA 4, wall mount; optional 19 rack mount 145cm tall, 60cm wide, 45cm deep wall mount standard 110 kg User selectable, either TC or TOC, standard Simultaneous TC, IC and TOC Simultaneous TC, IC, TOC and TN Optional manifold is available for multi-point sampling As we are continuously improving the performance of our equipment, specifications are subject to change without notice.

Suspended solids is not a problem even without filtration: Filtration of the sample process line is not required. This is achieved by using peristaltic pumps in the liquid flow pattern. Peristaltic pump is capable of handling even sludges and fluids carrying concentrated suspended solids, composing of even large particles up to 1200um in diameter. Unique furnace design for repeatability, accuracy and extended catalyst service life: Furnace is based on patented two zone design. First zone is operating at relatively higher temperatures between 600-1000 C, nominally at 900 C. This assures all carbon including particulate carbon to burn completely with no touch yet with the catalyst which is in the second zone operating at relatively lower temperatures, like 400-600 C assuring full functionality of the catalyst and achieving extended service life. Low-cost yet high-performance catalyst: The catalyst is developed in our own research facilities, lasts minimum 1500-2000 runs; because of relatively lower operating temperature and no direct contact with the sample but rather vapors and gas coming from the high temeperature zone. Unique sample dosing apparatus: Dosing of the sample volume is achieved by the unique, very sensitive levelling apparatus in the system. This assures repeatable sampling all times during continuous monitoring. Flexible configurations according to user needs: TC and TOC measurements are standard in all configurations. The user makes a choice to monitor either TC or TOC, in this case. TC, TOC, IC configuration allows the user to choose to monitor either TC only or simultaneous TOC and IC in the same run. TN function is an adder on top of both configuration, that allow simultaneous measurement of TC+TN or TOC+TN or TOC+IC+TN in the same run. process streamline to the TRL-onlineTOC monitor is achieved by the built-in sampling pump. For higher ranges above 5.000ppm carbon, dilution function is achieved via built-in peristaltic pumps and additionally with a very unique dosing system within the monitor enclosure. No dilution up to 5.000ppm carbon: Dilution of the sample is not required for the configurations up to 5.000ppm TC/TOC. Direct injection of the sample from the Validation of monitoring at user-set run-intervals: Allocation for a validation sample is provided within the equipment enclosure. The user may set a frequency of validation of the unit, for example, once every 50 sample runs or other. Then TRL-onlineTOC runs the validation sample and observes if the defined/given concentration is measured or not; if validated then continue otherwise log the result, send a warning message through digital output.

> Calibration files are developed through the touch screen, saved and called as necessary by the user, authorized to make calibration files as well as calibration of the monitor > As many calibration files as the user likes is saved in the memory to call/define for a specific type of monitoring, as needed > Unlimited measurement and log results are saved in the hard disk of the monitors built-in computer Digital output is standard: A digital output through RS232 port is readily available that carries measurement results, error and warning messages as well as messages for the measurements and over -and underalarm settings. Analog outputs: 4-20mA analog signals for measurement results as well as range identification are available. Alarm relays: The user can set alarm limits, based on which over-limit message for the results above upper limit and under-limit message for the results below lower limit are generated and are available as relay contacts. Intelligent software and user interface: Software allows smooth operation as well as flexible analysis cycle management. > Auto range adjustment: As accuracy of measurement is based on setting a measuring range of the monitor, the user, even though sets a measuring range to initialize monitor, does not need to worry about setting a proper range; TRLonlineTOC takes care of setting a proper measuring range for best accuracy, even if it was set wrongly by the user it resets based on the result it generates from the first measurement > Auto mode shift: TRL-onlineTOC operates based on its own and unique mode concept, that is related to the range of analyte (carbon) content of the sample. The user, sets a mode, either low or high, to initialize the monitor, however does not need to worry about setting the correct mode; TRLonlineTOC takes care of shifting to the proper mode for best repeatability even if it was set wrongly by the user it resets based on the result it generates from the first measurement > A USB port is available and pre-configured for transfering of the logged data and messages to the memory stick provided by the monitor > Touch screen keyboard-monitor in the eclosure is available for user settings. User profiles and authorities are set as to decribe functions allowed for every user level. Administrator is the manager of the system > Sampling and monitoring frequency, parameter to be monitored, user definition and sample definition are set through the touch screen keyboard Online TOC Applications and TRL-onlineTOC Configurations TRL-TOC is designed to be used in various applications. For each applications different configurations and specifications are available. > Industrial process water(requiring medium range of TOC, TC and IC up to 5.000ppm) To control and monitor different processes where water is used for heating or cooling To quantify and qualify efficiency of different production units > Industrial and municipal waste water (requiring high measuring range of TC, TOC, IC and TN up to 50.000ppm carbon) To control wastewater treatment operation To prevent contamination of the environment and meet effluent permits To control wastewater treatment operation > Tap water-drinking water(requiring very low measuring range for TC, TOC, IC and TN up to 50ppm) To assure public health and hygiene To control drinking water treatment plant's performance To control DI water quality in pharmaceutical industry

Software functions The user interface of TRL-onlineTOC is a dedicated software with its icons, messages and display characteristics. The operator can run diagnostic functions as well as introduce sample, method, calibration and task descriptions. It is very user friendly and functional in a way as to allow user hierarchies, limitless calibration point and calibration files, results, error and prompt messages, event logs storage Login page asks for user name and password to authorize login or reject. Authorization should already have been given by the administrator. As soon as TRL-onlineTOC is turned on an automatic diagnostic cycle runs through checking all essential components of the monitor, if they are communicating with the software. This control cycle can be checked manually whenever the operator wishes to do. As TRL-onlineTOC is a mechatronic equipment, there are quite a number of valves, motors running in a sequence managed by the firm and the software. Any one of these components can be initiated manually through the "equipment control" menu by the operator, as he needs to see if there is something wrong with any one of the individual functions. This helps in quick maintenance of the equipment. Task information page is the display in default operation. Recent results, concentration of validation standard, cycle number, sample-method definitions, instant values of furnace temperature, detector signal, range and current step within the running task are shown. The operator can develop a calibration file by getting use of calibration points. Points are analysis results of calibration samples. The operator can choose as many points as he sees appropriate. Immediately after choosing, he gets the y intercept and slope of the calibration file as well as R 2 so that he knows the quality of the calibration file, that is generated by the current selections. There should be at least two(high and low) calibration files for each parameter(toc, TC, etc.). All are intelligently brought into attention of the operator so that he can not disregard any one of the fields, to be filled in. It is possible to register a sample definition along with the required analysis parameter to monitor, like TC or TOC or IC. In this page, just before start running the monitoring task, the operator is supposed to describe the concentration of the validation standard that is placed in its position and to be used in case of validation requirement either by once every that many cycles or any inconsistency that TRL-onlineTOC recognizes by its intelligence.