ICON Analyzer. Dedicated online photometer for water and wastewater analysis
|
|
|
- Joella Morris
- 10 years ago
- Views:
Transcription
1 ICON Analyzer Dedicated online photometer for water and wastewater analysis
2 Straightforward online water monitoring 02 If there is one thing that everybody depends on, it is water. We drink it every day. We use it in nearly every industry as a cleaning agent, to moderate processes, or actually as a solvent in production. And once we have used it, it is discharged into the environment again. Therefore, it is of the utmost importance to society to monitor water quality. Plug and analyze Given the universal necessity and importance of water, any serious technical solution to monitor its quality should be easy to use, reliable, and of course, sensitive enough and highly accurate. These are in fact the features and benefits that the ICON Analyzer from Metrohm Process Analytics provides. The new ICON Analyzer was developed specifically for the near-continuous analysis of a large number of parameters critical for water quality. Very easy to use: Just connect the power, sample, and reagent lines and the ICON Analyzer is fully operational. Superior reliability: Validation, cleaning and calibration are standard features which significantly reduce downtime and operator intervention. Outstanding sensitivity & accuracy: Depending on the analyte and matrix, the determination ranges of the ICON Analyzer vary from trace µg/l to mg/l. Secure: The electronics part is 100% separated from the wet part of the analyzer. The ICON Analyzer is dedicated for the analysis of water and wastewater, and can be used in various situations: Wastewater effluent Surface water Drinking water Ultrapure water Steam and condensate water Ion-exchange systems Boiler feed water Demineralizers
3 03 Colorimetric method For more accuracy, the ICON Analyzer measures twice during one analysis cycle: The first measurement is from the raw sample as a reference, which compensates for the color and turbidity of the sample and the fouling of the cell. The second measurement of the sample is taken after the addition of color reagent and completion of the reaction. Based on the calibration and the differential absorbance, the software calculates the analyte concentration. The ICON Analyzer can measure a variety of components in water. All applications have been field-tested and have an excellent analytical performance. Some common analytes monitored for water quality control: Aluminum Ammonia Chlorine Chromium Copper Cyanide Hydrazine Iron Manganese Nickel Nitrate Nitrite Phenol Phosphate Silica Zinc And many more
4 Examples of proven applications 04 Metrohm Process Analytics has your analysis covered, whe ther you are measuring industrial waste or high-purity water. We have many Process Application Notes (PAN) and Application Data Sheets (ADS) available for more information. Silica Photometric determination of silica Application fields Cooling water, high-pressure boiler feed, highpurity water Silica is used in a variety of industries: from the production of wafers to glass and ceramics manufacturing and chemical production. In the water-steam cycle of power plants, silica is considered one of the major im purities, causing boiler scale and deposits on steam turbine blades. Impurities precipitated out of the water form deposits on heat transfer surfaces, which result in re duced boiler efficiency, overheating, and eventually out ages. Silica also plays an important process control role at demineralization plants where deionized water is produced. An increase in the silica concentration signals an exhausted ion-exchange bed and is therefore an indicator that regeneration is necessary. Iron Photometric determination of iron(ii) and (III) Application fields Drinking water, surface water, industrial wastewater, cooling water, high-pressure boiler feed Iron is quite abundant naturally in our environment; it is also used in many different applications and industries worldwide. Soluble Fe(II) is present in anaerobic water, oxidizing to Fe(III) when exposed to air or other oxidizing agents. The resulting turbidity from less-soluble Fe(III) can cause problems. In drinking water, an excessive presence of iron is a problem, as it affects both the taste and smell. There are many ways for iron in all forms to be introduced into our water sources, making it an important analyte to measure.
5 Phosphate Photometric determination of phosphate Application fields Surface water, municipal waste, industrial wastewater, cooling water, high pressure boiler feed 05 Phosphorus compounds are essential to the growth of plant life and other organisms. However, the increasing concentrations of these compounds from wastewater and agricultural runoff create nutrient imbalances in lakes and other areas. This imbalance promotes an increase in algal blooms which can eventually lead to total oxygen depletion (anoxia), resulting in the death of fish and other aquatic animals. Phosphates can be introduced to the environment via agricultural (fertilizer) runoff resulting from rain storms or snow melt. Other wastewaters may also contain higher concentrations of phosphates, introduced by detergents and other cleaning solutions. Boiler water is frequently treated with phosphates to prevent boiler scaling leading to premature boiler failure. Ammonia Photometric determination of ammonia Application fields Cooling water, surface water, municipal wastewater, industrial wastewater Ammonia can come from a variety of sources, with agriculture and wastewater treatment among the largest producers. Ammonia is used as a precursor to create many fertilizers. High concentrations of ammonia or ammo nium salts are present (depending on the type of fertilizer in use) which contribute nitrogen to the environmental nutrient balance, promoting plant growth. Nitrogen is a limiting nutrient in marine environments, thus its increase due to agricultural runoff or from improperly treated wastewater can create significant ecological imbalances and anoxia, similar to the environmental effect of excess phosphates. Nitrification converts ammonium into nitrite and nitrate. Compounds are typically added to fertilizers to stop this process because nitrite and nit rate are much more water-soluble and contaminate water sources. Wastewater treatment uses both nitrification and denitrification processes to convert ammonium into harmless nitrogen gas, which is then released into the atmosphere. Other examples available: Aluminum, chlorine, chromium, copper, cyanide, hydrazine, manganese, nickel, nitrate, nitrite, phenol, zinc
6 Flexible software for straightforward control 06 The ICON Analyzer is equipped with a graphical user interface for easy access to your analyses and results. There are multiple user levels offered in the software which are suitable for any operator. With up to 30 programmable steps available for each analysis, the ICON offers more than enough flexibility to adjust to the needs of any user. Validation, cleaning, and calibration are standard features built in to the analyzer which assist in the optimization of the system and help ensure the most accurate results are obtained. A graphical overview of the most important data from your application is available at your fingertips. Not only will analysis results be logged into the database, alarms can also be managed. For example, an alarm for low reagent levels can appear in the graphical user interface, sent to a control room for further review by the operator, and it can also be logged in the database. Main analysis screen Application method Alarm notification Method-building choices Results table Event log
7 Simplified layout for easy access The ICON Analyzer is complete, preconfigured and programmed for your specific application. Just connect the power, sample, and reagent lines and the easy-to-use analyzer is fully operational. The high uptimes and minimal maintenance of the ICON Analyzer lead to lower operating costs. The ICON Analyzer as designed ensures the highest level of robustness in the electronics, mechanics, and hydraulics components. 07 Features Dual compartment enclosure to ensure complete separation between the electronics and the wet part, therefore no leakages possible into the electronics part Color touchscreen interface; simple and user-friendly menus and functions Multiple user levels 3 programmable cycles, with 30 programmable steps per cycle for analysis flexibility Long-life LED light source Built-in peristaltic pump for sampling Thermostated reaction cell Automatic validation and automatic cleaning 2 sample streams can be monitored Up to 3 reagents can be added simply add a pump for additional reagents, as shown below: Layout of the wet part of the ICON Analyzer for the addition of 1, 2, and 3 reagents.
8 Technical specifications Small dimensions Analysis method Analysis frequency Installation Ingress Protection User adminstration Digital inputs Digital outputs Analog outputs Serial interface RS232 Data logger mm Differential photometric absorbance Freely programmable, near-continuous analysis Wall mount or bench top support IP54 Password protected input on 2 levels online on/off, remote start/stop, sample override, etc. Analyzer on, online fault alarm, no sample flow 1 and 2, low reagent level alarm, calibration error, validation error, result alarm, etc. 2 analog outputs, 4 20 ma MODBUS Protocol For alarms and results, integrated with USB download function Subject to change Layout by Ecknauer+Schoch ASW, printed in Switzerland by Metrohm AG, CH-9100 Herisau EN
The Nitrogen Cycle. What is Nitrogen? Human Alteration of the Global Nitrogen Cycle. How does the nitrogen cycle work?
Human Alteration of the Global Nitrogen Cycle Heather McGraw, Mandy Williams, Suzanne Heinzel, and Cristen Whorl, Give SIUE Permission to Put Our Presentation on E-reserve at Lovejoy Library. What is Nitrogen?
Standard methods in water analysis
Branch General analytical laboratories; water analysis Keywords Water analysis; standard methods; ASTM; DIN; ISO; USP; EPA; SLMB; EN; SCA; titration; ion chromatography; voltammetry; branch 1; branch 2
TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES
TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES JOHN F. BOSSLER, SIEMENS Water Technologies Corp., Hoffman Estates, IL RONALD TRAVIS, SIEMENS Water Technologies
How to measure Ammonia and Organic Nitrogen: Kjeldahl Method
World Bank & Government of The Netherlands funded Training module # WQ - 38 How to measure Ammonia and Organic Nitrogen: Kjeldahl Method New Delhi, March 2000 CSMRS Building, 4th Floor, Olof Palme Marg,
Presented by Paul Krauth Utah DEQ. Salt Lake Countywide Watershed Symposium October 28-29, 2008
Basic Nutrient Removal from Water Beta Edition Presented by Paul Krauth Utah DEQ Salt Lake Countywide Watershed Symposium October 28-29, 2008 Presentation Outline Salt Lake County waters / 303(d) listings
Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC
Common Problems with Online Water Quality Analyzers Greg Macy Director AquatiPro LLC Objectives Diagnosing Colorimetric Analyzers Identifying Common Problems with Sodium Analyzers Troubleshooting ph Analyzers
AMMONIA AND UREA PRODUCTION
AMMONIA AND UREA PRODUCTION Urea (NH 2 CONH 2 ) is of great importance to the agriculture industry as a nitrogen-rich fertiliser. In Kapuni, Petrochem manufacture ammonia and then convert the majority
Which of the following can be determined based on this model? The atmosphere is the only reservoir on Earth that can store carbon in any form. A.
Earth s Cycles 1. Models are often used to explain scientific knowledge or experimental results. A model of the carbon cycle is shown below. Which of the following can be determined based on this model?
Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.
Page 16 of 87 3.3 Sample Collection, Storage and Preservation Figure 3 details required containers, sample volumes, preservation techniques, and holding times for proper sample collection. A discussion
Toxicity. Toxicity monitoring technologies for on line, on location and the laboratory
Toxicity Toxicity monitoring technologies for on line, on location and the laboratory Contents Microtox M500 page 2 DeltaTox II page 4 Microtox CTM page 6 Technical support page 8 Specifications page 10
Total Suspended Solids Total Dissolved Solids Hardness
Total Suspended Solids (TSS) are solids in water that can be trapped by a filter. TSS can include a wide variety of material, such as silt, decaying plant and animal matter, industrial wastes, and sewage.
Phosphorus. Phosphorus Lake Whatcom Cooperative Management. www.ecy.wa.gov/programs/wq/nonpoint/phosphorus/phosphorusban.html
Phosphorus Phosphorus Brochure Lake Whatcom Cooperative Management Reducing Phosphorus Website Washington State Department of Ecology www.ecy.wa.gov/programs/wq/nonpoint/phosphorus/phosphorusban.html Nutrients
WASTEWATER TREATMENT OBJECTIVES
WASTEWATER TREATMENT OBJECTIVES The student will do the following: 1. Define wastewater and list components of wastewater. 2. Describe the function of a wastewater treatment plant. 3. Create a wastewater
A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER
A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER ABSTRACT Leonard P. Seed, M.Sc., P.Eng., Enpar Technologies Inc. * Daren D. Yetman, A.Sc.T., Enpar Technologies
LIMNOLOGY, WATER QUALITY
LIMNOLOGY, WATER QUALITY PA RANI ET E R S, AN D c 0 IV D IT I 0 N S AND ECOREGIONS Water Quality Parameters Nutrients are important parameters because phosphorous and nitrogen are major nutrients required
Removing Thallium from Industrial FGD Scrubber Water with Sorbster Adsorbent Media
Case History MAR Systems Inc. Removing Thallium from Industrial FGD Scrubber Water with Sorbster Adsorbent Media Trace thallium levels in process and wastewater streams pose a human toxicity threat. Tidwell
Metal Ion + EDTA Metal EDTA Complex
Simplified Removal of Chelated Metals Sultan I. Amer, AQUACHEM INC. Metal Finishing, April 2004, Vol. 102 No. 4 Chelating agents are used in large quantities in industrial applications involving dissolved
Wastewater Nutrient Removal
Wastewater Nutrient Removal An overview of phosphorus and nitrogen removal strategies Presented by: William E. Brown, P.E. Peter C. Atherton, P.E. Why are nutrients an issue in the environment? Stimulates
How To Water System
Mid-Monroe Water System: Soluble Iron and Manganese Removal via Oxidation & Filtration Daniel Rickard, P.E. Engineering Project Manager Pennsylvania-American Water Company Who Is American Water We are
2014 Service Technician Training Program Closed Loop Systems
1/20/14 2014 Service Technician Training Program Closed Loop Systems Daniel S. Krack, CWT 2 Closed Loop Cooling and Heating The Closed Loop Cooling Advantages High Efficiency Chillers, Heat Exchangers,
Floating Treatment Wetland Technology: Nutrient Removal from Wastewater
Floating Treatment Wetland Technology: Nutrient Removal from Wastewater This case study illustrates the Floating Island International (FII) patented floating treatment wetland (FTW) technology and its
AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES
AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES Question 1 Read the Fremont Examiner article below and answer the questions that follow. (a) Identify ONE component of the sewage that is targeted for removal
THE WATER CYCLE. Ecology
THE WATER CYCLE Water is the most abundant substance in living things. The human body, for example, is composed of about 70% water, and jellyfish are 95% water. Water participates in many important biochemical
Customer application report
16 Cape Town drinking water monitoring solution from Metrohm On 28 July 2010, the General Assembly of the United Nations declared clean water and sanitation as a fundamental human right! This underlines
Remediation of VOC Contaminated Groundwater
Remediation of VOC Contaminated Groundwater Background Contaminated groundwater has become an ever-increasing problem in the United States and around the world. Treatment and disposal of waste is a serious
Birmingham City University / Students Union Aspects and Impacts Register. Waste. Impacts description
Birmingham City University / Students Union and Impacts Register Waste Production of non - hazardous waste Production of hazardous waste Storage of non - hazardous waste Potential for waste to be disposed
Removing Heavy Metals from Wastewater
Removing Heavy Metals from Wastewater Engineering Research Center Report David M. Ayres Allen P. Davis Paul M. Gietka August 1994 1 2 Removing Heavy Metals From Wastewater Introduction This manual provides
SOLUTIONS FOR ENVIRONMENTAL ANALYSIS
SOLUTIONS FOR ENVIRONMENTAL ANALYSIS 02 MEETING THE CHALLENGES OF SUSTAINABLE DEVELOPMENT The analytical expertise AMS Alliance is one of the major players for analysis in the agro-food and environmental
Water Recycles poster
Water Recycles poster The "Water ReCycles" poster is designed for students of all ages. It shows the natural water cycle and humans influence on water resources. Raincloud illustration The raincloud in
Nutrient Stewardship. Reducing the Loss of Crop Nutrients to Waterways
ETS & PERFORMANCE FOOD ENVIRONMENT PEOPLE COMPANY Nutrient Stewardship Reducing the Loss of Crop Nutrients to Waterways Crop nutrients help plants grow and produce the food, fiber and fuel we all need.
ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc.
Summary ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc. The rendering industry has a significant positive impact on environmental quality.
Facility Classification Standards
Facility Classification Standards Approval Date: April 3, 2009 Effective Date: April 3, 2009 Approved By: Nancy Vanstone, Deputy Minister Version Control: Replaces Facility Classification Standards dated
Scope and application: For testing residual corrosion inhibitors (oxygen scavengers) in boiler feed water or condensate
Oxygen Scavengers DOC316.53.01105 Iron Reduction Method Method 8140 3 to 450 µg/l DEHA; 5 to 600 µg/l carbohydrazide; 9 to 1000 µg/l hydroquinone; 13 to 1500 µg/l iso-ascorbic acid (ISA); 15 to 1000 µg/l
TRL-onlineTOC Monitor is designed for monitoring carbon content in
TRL-onlineTOC Online TOC Monitor TRL-onlineTOC Monitor is designed for monitoring carbon content in Industrial process water To control and monitor different processes where water is used for heating or
Low Impact Development
Low Impact Development for Linear Transportation Projects Disclaimer This project was developed through an Assistance Agreement under the U.S. EPA Office of Water 104 b(3) Program. It is intended for use
Nitrogen Cycling in Ecosystems
Nitrogen Cycling in Ecosystems In order to have a firm understanding of how nitrogen impacts our ecosystems, it is important that students fully understand how the various forms of nitrogen cycle through
IMPACT OF CHEMICALS ADDITION IN WATER/WASTEWATER TREATMENT ON TDS CONCENTRATION AND SLUDGE GENERATION Jurek Patoczka, PhD, PE Hatch Mott MacDonald 27 Bleeker Str., Millburn, NJ 07041 (973) 912 2541 [email protected]
Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level
Solutions for the Process Industries Rosemount Analytical s -STREAM E Web-Browser Interface Takes Process Analysis to the Next Level The -Stream E takes process gas analysis to the level of ease of use
Chapter 14 Quiz. Multiple Choice Identify the choice that best completes the statement or answers the question.
Chapter 14 Quiz Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Which of the following is NOT true regarding the Chesapeake Bay? a. it is one of many small
Ion-selective Measurements
Ion-selective Measurements Ion-selective measurement is a method for determining the concentration of dissolved ions. Potassium ions, sodium ions, fluoride or chloride are examples of such cations and
Ion Exchange Softening
Ion Exchange Softening Ion-exchange is used extensively in small water systems and individual homes. Ion-exchange resin, (zeolite) exchanges one ion from the water being treated for another ion that is
Inferred ph in Steam Plant Water Chemistry Monitoring
Application Data Sheet ADS 4900-87/rev.B January 2009 Power Industry Inferred ph in Steam Plant Water Chemistry Monitoring INTRODUCTION Inferred ph means ph calculated from straight and cation conductivity.
Water... The essence of life
Water... The essence of life THE WATER SPECIALISTS Clean fresh water is absolutely essential in agricultural, industrial, household, recreational and environmental human activities. At the same time, water
Iron and manganese are two similar elements
L-5451 2-04 Drinking Water Problems: Iron and Manganese Mark L. McFarland, Associate Professor and Extension Soil Fertility Specialist Monty C. Dozier, Assistant Professor and Extension Water Resources
CNSolution TM 9310 On-line Cyanide Analyzer. Product Release Synopsis. I Product Description/Function. 1 3 Cyanide Recycle
CNSolution TM 9310 Product Release Synopsis I Product Description/Function The CNSolution 9310 is designed to measure and control cyanide used in hydrometallurgical leaching of gold and silver from ores.
Iron and Manganese BACTERIA AND IRON AND MANGANESE
Iron and Manganese Iron and manganese control is the most common type of municipal water treatment in Minnesota. Iron and manganese occur naturally in groundwater. Neither element causes adverse heath
Phosphates (ortho- and total)
INTRODUCTION Phosphates (ortho- and total) Phosphorus is an essential nutrient for all aquatic plants and algae. Only a very small amount is needed, however, so an excess of phosphorus can easily occur.
Missouri Streams. Fact Sheet. By Danny Brown & Jim Czarnezki Edited by Chris Riggert & Sarah Wolken
Missouri Streams Fact Sheet By Danny Brown & Jim Czarnezki Edited by Chris Riggert & Sarah Wolken Chemical parameters play an important role in the health, abundance, and diversity of aquatic life. They
Technical Publication. Title: Using Online Analyzer for Optimizing Chemical Phosphorus Removal Process in Municipal Wastewater Treatment
Technical Publication Title: Using Online Analyzer for Optimizing Chemical Phosphorus Removal Process in Municipal Wastewater Treatment ASA Publication #211 Presented at: WEAO Technical Conference Ottawa,
Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000
IMR 5000 Continuous Flue Gas Monitoring System The IMR 5000 is state-of-the-art continuous flue-gas monitoring system, and is designed for a wide variety of flue-gas monitoring applications. The IMR 5000
How To Prevent Corrosion In A Steam Electric Power Plant
Keeping corrosion at bay Analysis in ultra-supercritical power plants Corrosion is the natural enemy of steam-electric power plants, eating away at pipes, turbine blades, and rotors. The lack of a separation
Water Efficiency. Water Management Options. Boilers. for Commercial, Industrial and Institutional Facilities. Boiler Water Impurities
Water Efficiency Water Management Options Boilers for Commercial, Industrial and Institutional Facilities Boiler Water Impurities All boiler make-up water contains impurities. As clean steam is released
In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..
Identification of a Substance by Physical Properties 2009 by David A. Katz. All rights reserved. Permission for academic use provided the original copyright is included Every substance has a unique set
Facility Operations Physical Safety Guidance Document
Facility Operations Physical Safety Guidance Document Title: Guide on Pipe Identification Standards (ASME A13.1-1996) Original Date: December 18, 2000 Section: 4.0 Facility Operations Revised Date: Number:
RECOMMENDED SPECIFICATION. Cogent Environmental OVA-5000 Heavy Metal Analyzer. to Monitor Total Dissolved Arsenic. for
Pub# 190, effective 12-23-08 RECOMMENDED SPECIFICATION Cogent Environmental OVA-5000 Heavy Metal Analyzer to Monitor Total Dissolved Arsenic for Ion Exchange Process Monitoring 1.0 Functional Specifications
Nitrate and Nitrite Removal from Municipal Drinking Water Supplies with Electrodialysis Reversal
Technical Paper Nitrate and Nitrite Removal from Municipal Drinking Water Supplies with Electrodialysis Reversal Authors: Ted Prato and Richard G. Parent, Ionics Reprinted from Proceedings of 1993 AWWA
Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc. [email protected] 201 529 5151 X 7167
Nutrient Removal at Wastewater Treatment Facilities Nitrogen and Phosphorus Gary M. Grey HydroQual, Inc. [email protected] 201 529 5151 X 7167 1 Agenda Nitrification and Denitrification Fundamentals
Continuous-Flow Analyzers
_ Continuous-Flow Analyzers _ Rapid Control of Fertilizer Quality with the AutoAnalyzer Legislation and quality requirements have led to the need for close control of fermentation and finished products
4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES
4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES Sl. No. Contents Preamble 4.1 Aim 4.2 Introduction 4.2.1 Environmental Significance 4.3 Principle 4.4 Materials Required 4.4.1 Apparatus Required 4.4.2 Chemicals
Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources
Reuse of Alternative Water Sources for Cooling Tower Systems Two Case Studies Using Non-Traditional Water Sources Matthew L. Haikalis Veolia Water Solutions & Technologies April 24, 2013 Operational Priorities
Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water
United States Office of Water EPA 916-F-01-032 Environmental Protection (4606) July 2001 Agency Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows
6 Chemicals from human settlements
6 Chemicals from human settlements 6.1 Introduction The world is becoming increasingly urban, particularly in developing countries. The transition of people from rural areas to cities represents a major,
Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director
Silica Over-Saturation, Precipitation, Prevention and Remediation In Hot Water Systems Edited By Dave Peairs, Cal Water, Technical Director Background Silica scaling becomes a problem when any hot water
How To Understand And Understand The Effects Of Pollution And Water Quality
Lesson 2. Pollution and Water Quality Keywords: pollutants, water pollution, point source, non-point source, urban pollution, agricultural pollution, atmospheric pollution, smog, nutrient pollution, eutrophication,
Welcome to the Understanding Dissolved Oxygen learning module. This section provides information on the following topics:
Introduction Welcome to the learning module. This section provides information on the following topics: How dissolved oxygen is defined and measured in numbers Why dissolved oxygen is important Natural
a. a population. c. an ecosystem. b. a community. d. a species.
Name: practice test Score: 0 / 35 (0%) [12 subjective questions not graded] The Biosphere Practice Test Multiple Choice Identify the letter of the choice that best completes the statement or answers the
Phosphorus Removal in Wastewater Treatment
RESEARCH & DEVELOPMENT REPORT NO. Phosphorus Removal in Wastewater Treatment (Final Report) Research and Development Section Electrical & Mechanical Projects Division Nov 2013 Final Report endorsed by
EPA Trends for wastewater Treatment in California - 2011
EPA S TECHNOLOGY NEEDS FOR THE WATER AND WASTEWATER INDUSTRY Nancy Stoner Acting Assistant Administrator U.S. EPA Office of Water International Emerging Technology Symposium Arlington, VA April 23rd, 2014
ANAEROBIC/ANOXIC TANKS
PROCESS DESCRIPTION In the anaerobic/anoxic tanks, wastewater is prepared for further treatment in the biological reactors. Denitrification and luxury uptake of phosphorus take place by mixing a food source
SPIKE RECOVERY AND DETERMINING A METHOD DETECTION LIMIT Pamela Doolittle, University of Wisconsin Madison, [email protected] 2014
SPIKE RECOVERY AND DETERMINING A METHOD DETECTION LIMIT Pamela Doolittle, University of Wisconsin Madison, [email protected] 2014 This experiment explores quality assurance practices which are commonly
Expertise in liquid analysis From sensors to complete turnkey solutions
Products Solutions Services Expertise in liquid analysis From sensors to complete turnkey solutions Liquid analysis 2 The Liquiline Family The Liquiline Family 3 Memosens - The digital revolution in process
IC Food Packs. Complete packs for food analysis. Free with every IC Food Pack: MagIC Net software Ultrafiltration
IC Food Packs Complete packs for food analysis Free with every IC Food Pack: MagIC Net software Ultrafiltration 02 Make your food analysis more efficient! Ion chromatography (IC) is a versatile, proven
SECOND GRADE 1 WEEK LESSON PLANS AND ACTIVITIES
SECOND GRADE 1 WEEK LESSON PLANS AND ACTIVITIES WATER CYCLE OVERVIEW OF SECOND GRADE WATER WEEK 1. PRE: Exploring the properties of water. LAB: Experimenting with different soap mixtures. POST: Analyzing
What are the subsystems of the Earth? The 4 spheres
What are the subsystems of the Earth? The 4 spheres Essential Questions What are the 4 spheres of the Earth? How do these spheres interact? What are the major cycles of the Earth? How do humans impact
Sulfites for Oxygen Control
If you would like a more detailed version of this report, please request SOS from [email protected] along with your e-mail address. A. Introduction Sulfites for Oxygen Control Robert R. Cavano
CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
A Primer on Protecting Idle Boilers By Howard Benisvy, Member ASHRAE
The following article was published in ASHRAE Journal, December 2002. Copyright 2002 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. It is presented for educational purposes
EPB 311- Strategies for Dealing with Groundwater Treatment Systems Having High Natural Ammonia
EPB 311- Strategies for Dealing with Groundwater Treatment Systems Having High Natural Ammonia Background The occurrence of ammonia (NH 3 ) in the water source is often associated with pollution due to
Don t spit in the well - you may need to drink from it! -- Unknown, Russia.
Don t spit in the well - you may need to drink from it! -- Unknown, Russia. WATER POLLUTION Water is a unique substance, because it can naturally renew and cleanse itself, by allowing pollutants to settle
COOLING WATER MANAGEMENT
COOLING WATER MANAGEMENT Intent To minimize the carbon-footprint, water usage and environmental impact of HVAC cooling systems and process cooling systems, generally by optimizing the control of water
Process Instrumentation
Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A
Environmental aspects of water fluoridation
KEY POINTS Fluorides are very common in the environment. Reviews of the literature and environmental impact assessments have found no evidence of any adverse environmental effects resulting from water.
G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method
G4 ICARUS HF Simultaneous Determination of Carbon and Sulfur in Solids Innovation with Integrity Combustion Method High Performance Carbon & Sulfur Analyzer Combustion Method with High-Frequency Furnace
Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations
Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations 2 One Solution for Monitoring, Control or Both There are many ways to improve the efficiency and reliability of your
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
STORMWATER MONITORING: POLLUTANTS, SOURCES, AND SOLUTIONS
RICHLAND COUNTY STORMWATER MANAGEMENT DIVISION STORMWATER MONITORING: POLLUTANTS, SOURCES, AND SOLUTIONS As part of the federal government s National Pollutant Discharge Elimination System Permit (NPDES)
Lesson Plan: How Do We Clean Polluted Water?
Lesson Plan: How Do We Clean Polluted Water? Oil Spill Cleanup / Phosphate Cleanup / Groundwater Contamination / Water Treatment Simulation Estimated Time: 2-4 days State Standards taught and addressed
Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)
Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method) Grace Analytical Lab 536 South Clark Street 10th Floor Chicago, IL 60605 April 15, 1994 Revision 2 Standard Operating Procedure
9707 Key West Avenue, Suite 100 Rockville, MD 20850 Phone: 301-740-1421 Fax: 301-990-9771 E-Mail: [email protected]
9707 Key West Avenue, Suite 100 Rockville, MD 20850 Phone: 301-740-1421 Fax: 301-990-9771 E-Mail: [email protected] Part of the recertification process is to obtain Continuing Education Units (CEUs). One way
Mine Water Treatment Solutions for Discharge and Re-Use
Mine Water Treatment Solutions for Discharge and Re-Use Bernhard Doll Pall Corporation Summary This paper focusses on the description of reliable, safe and economical treatment of mine water from different
POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors
POLARIS AIR COMPRESSOR SERIES engineering excellence stellar performance P - 3 0 0 RELIABLE 100% OIL-FREE ENGINEERED AIR A World Leader for Centrifugal Compressors It s simple: The Polaris Air Compressor
Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry
Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry Models UVS-1, MoniSpec-UV & MoniSpec-UVd Model UVS-1 general information
Overview of Best Available Technologies for Onsite Septic Systems and Management Considerations Presentation to NAHB
Overview of Best Available Technologies for Onsite Septic Systems and Management Considerations Presentation to NAHB A. R. Rubin, Professor Emeritus, NCSU-BAE Technical Wastewater Issues Treatment Septic
Secondary Lead Smelting
Secondary Lead Smelting Secondary Lead Smelting Objectives Describe the basic smelting process terms: smelting, refining, and alloying List key chemicals associated with secondary lead smelting Define
Sewerage Management System for Reduction of River Pollution
Sewerage Management System for Reduction of River Pollution Peter Hartwig Germany Content page: 1 Introduction 1 2 Total emissions 3 3 Discharge from the wastewater treatment plants 4 4 Discharge from
Texas Commission on Environmental Quality
Matrix: Drinking Water Method EPA 1603 (modified mtec) AB ID Method ID Escherichia coli (enumeration) TX 2525 10236201 Method EPA 200.5 AB ID Method ID Arsenic TX 1010 10213975 Beryllium TX 1020 10213975
STOCKMEIER water chemicals Strong bonds for clear water
STOCKMEIER water chemicals Strong bonds for clear water Water a strong compound for life Why H O is so unique Water, the source of all life. Without water, life would never have developed on our planet
DOC# IMBU-PB-REMOTE-MONITORING-01-EN IMBU. Remote monitoring of industrial equipment
IMBU Remote monitoring of industrial equipment imbu IMBU s remote monitoring solution is both an operational performance dashboard for upper management, and a diagnostic tool for engineers, mechanics and