SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR. www.sentryair.com 1.800.799.



Similar documents
Ductless Spray Booth Series

Laminar Flow Cabinets

Controlling health risks from rosin (colophony)-based solder flux fume

Fume Hood Questions and Answers

Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

LAMINAR AIRFLOW EQUIPMENT CLASS I BIOLOGICAL SAFETY CABINETS BIOLOGICAL ENCLOSURES

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

What to Know When Considering a Cleanroom. by Simplex Technical Staff

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Geismar Site Reviewed: 07/05/16 Effective: 07/05/16 Supersedes: 08/04/14 Preparer: Owner: Approver: S/IH Team Leader S/IH Team Leader Manager LA Hub

SECTION HVAC AIR-DISTRIBUTION SYSTEM CLEANING

Chapter 12 Industrial Ventilation

Indoor Air Quality Issues for Hotels

Radford University. Indoor Air Quality Management Plan

Understanding USP 797

Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project

A SELF-EVALUATION CHECKLIST of BEST PRACTICES for AUTO REFINISH SHOPS and SCHOOLS

Cooktop Low-Profile Ventilation Hoods

Today, healthcare facilities must be prepared to face

DESIGN OF GREASE FILTER EQUIPPED KITCHEN EXHAUST SYSTEMS

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

During Various Aluminum Fabricating Operations

Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

SPECIAL APPLICATIONS

Downflo workstation DuSt ColleCtorS

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions

Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material

How to Choose An Air Filter For Your Boat

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

CLEAN ROOM TRAINING CLEAN ROOM AREAS

Safety Data Sheet ANGSTRON MATERIALS, INC. PRODUCT NAME: N002-PDR. Inquiries: Fax Number: Telephone Number:

PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)

STATEMENT OF WORK (SOW) 2. Contract Title. HEPA Supply/Exhaust fans for Clean room USP 797 Compliance

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Fume Cupboard Guidance

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Clearing the air A simple guide to buying and using local exhaust ventilation (LEV)

IEQ-15 Air Distribution System

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

JANUARY 2013 GUIDANCE NOTES ON HEATING, VENTILATION AND AIR- CONDITIONING (HVAC) SYSTEMS FOR MANUFACTURERS OF ORAL SOLID DOSAGE FORMS

Risk Assessment: Biosafety Cabinet

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

A Report of Air Sampling for Mercury Vapor and Particulates During Fluorescent Tubes Disposal Operation Maywood, Illinois Survey date: 9/28/2000

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Performance Evaluation of Cleanroom Environmental Systems. Biography. Abstract. Keywords. Introduction

/pdf/ Thu Aug 22 09:51: HFGR30S8 MATERIAL SAFETY DATA SHEET

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

W850. Maintenance Guide

Effectiveness of Engineering controls (LEVs)

CHAPTER 4 VENTILATION

HEPA FILTER DEFECTS ARE COMMON

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

User Manual LFGI-3USP LFGI-4USP LFGI-6USP. GERMFREE 11 Aviator Way Ormond Beach, FL Phone Fax

Spetec. Laminar Flow Box. Portable Clean Room Technology

HEALTHY CLIMATE HEPA BYPASS AIR FILTRATION SYSTEM READ AND SAVE THESE INSTRUCTIONS! AIR CLEANERS/ FILTERS

RedCore 1500 Infrared PTC Heater

High Efficiency Particulate Air (HEPA) Filter Velocity Reduction Study

Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection

Commercial Kitchen Fire Safety

Biosafety Level 2 (BSL-2) Safety Guidelines

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

How to Estimate the Cost of a. Laboratory Renovation. Candidate Number:

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

LAMINAR FLOW FOR ALL YOUR NEEDS

APPENDIX B. EPA s Investigating, Evaluating, and Remediating Moisture and Mold Problems (see EPA website for complete details)

WINDOW ROOM AIR CONDITIONER

Owner's Manual Air-Purifier MK-B1000 Air Cleaning Expert 110V Model

Lead Exposure Management Plan

Industrial Ventilation Design Guidebook Chapter 10 LOCAL VENTILATION

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

MC² Market & Competitive Convergence Air Filters: New Facilities, New Standard

Continuous-Flow Supplied Air Respirator

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

HVAC Design Requirements

OSHA and Welding Exhaust

Construction Drawings and Terminology for the Infection Prevention Professional. Objectives. Disclaimer

Recommendations for the Safe Use of Handling of Cytotoxic Drugs

Ethanol-Water Phase Separation White Paper

Range Equipment HVAC Design & Supply Modular Ranges

Camfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality

In Vitro Fertilization Workstation. Esco IVF Workstation, Model IVF-4A_. Shown with optional support stand.

NADCA GENERAL SPECIFICATIONS FOR THE CLEANING OF COMMERCIAL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS

Laminar Flow Hoods and Booths

Condensate Trapping: Don't Get Caught in a Trap of Your Own! - From the Trane Inc Website 1

Ductless Heat Pumps for Passive Houses

ENHANCED LABORATORY HVAC SYSTEM

Material Safety Data Sheet

Principles of Ventilation. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Transcription:

SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR 1.800.799.4609 www.sentryair.com

Pharmaceutical Compounding Safety Solutions Sentry Air Systems Pharmaceutical Compounding Containment Systems are ductless engineering safety controls designed to help protect the respiratory zones of pharmacists or pharmacy students while compounding, measuring, and weighing prescription dosages. Pharmaceutical Containment Hoods PAGES 3-4 Pharmaceutical Containment Hoods come in a variety of sizes and are equipped with powerful fans and high-quality HEPA filtration media. Product Features HEPA Filters: 99.97% efficient on particles 0.3 microns and larger Quiet Operation No Vibrations Variable Speed Control on Most Models For more information and product specifications. Additional Configurations PAGE 5 No External Venting Required Long Filter Life Reliable, Low Maintenance Operation Custom Sizes Available Simple, Quick "No Tool" Filter Change The Winged Sentry is a unique powder extraction unit that features infinitely adjustable side flaps for optimum source capture. Product Features HEPA Filters: 99.97% efficient on particles 0.3 microns and larger Quiet Operation Adjustable Side Flaps Highly Portable and Lightweight Two Models Available [200 & 300] For more information and product specifications. Optional Hinged Clear, Acrylic Lid No External Venting Required Variable Speed Available on Model 300 Reliable, Low Maintenance Operation Simple, Quick "No Tool" Filter Change Because of the serious health risks associated with exposure to hormones and powders involved in pharmaceutical compounding, respiratory precautions should be taken. Sentry Air s pharmaceutical compounding hoods utilize a powerful fan and filtration system that pulls harmful contaminants away from the operator s breathing zone and directly into the HEPA filter, which is up to 99.97% efficient on particles 0.3 microns and larger. Other filtration media that may be utilized are ASHRAE [up to 95% efficient on particles 0.5 microns and larger] and ULPA filters[up to 99.9995% efficient on particles 0.12 microns and larger]. Utilizing a portable ductless system conserves space, saves energy, and purifies the air so that harmful particles are not distributed back into the immediate area and environment. Simple Solutions for Cleaner Air Contact Us 1-800-799-4609 www.sentryair.com sales@sentryair.com MADE IN THE USA 1.

Pharmaceutical Compounding Hood Series Pharmaceutical Compounding Hoods, also known as Powder Containment Hoods, are self-contained work stations that protect operators respiratory zones from specific harmful airborne contaminants that have been released from compounding applications in the work area of the hood. The powerful fans situated at the top of these hoods creates the negative air pressure that pulls dirty air up and away from the operator s breathing zone. This contaminated air is then directed into the filter chamber, which houses various filter media dependent on the type of particulate that is generated. In most compounding cases, HEPA filtration is utilized [Sentry Air s HEPA filters are up to 99.97% efficient on particles 0.3 microns and larger]. Because the air is scrubbed clean of contaminants by the filter media and then circulated back into the room, no exterior-ducting or make-up is necessary in combination with these units. Sentry Air Systems offers both Standard and Custom Size Pharmaceutical Compounding Hoods Why Go Ductless? There are numerous advantages to utilizing a Ductless Powder Containment Hood as opposed to conventional exterior-ducting hoods. DUCTLESS HOODS ARE GREENER Ducted exhaust hoods release contaminated vapors and hazardous powders directly into the environment Ductless hoods trap hazardous vapors and fumes in filters where they can be removed and disposed of properly. ENERGY EFFICIENCY Ducted exhaust systems require a significant amount of make-up air while they are running. Because ductless hoods recirculate the air within the room; no energy needs to be spent on heating or cooling make-up air. COST EFFICIENCY & MINIMAL MAINTENANCE $ Zero Installation Costs Ducted exhaust hoods contain additional costs for ducting and installation and may even require costly engineering design and consultation. Ductless hoods require minimal assembly or installation and in most cases require none at all. Low Maintenance Costs Ducted exhaust systems can require much more maintenance. For example, ducting that is clogged, corroded or too dirty requires time-consuming cleaning or complete replacement of the system. Practically the only up-keep cost requirement for ductless hoods is the replacement of saturated filter media and an occasional quick wipe down cleaning of the hood. MOBILITY Standard Sizes are: 12 18 24 30 40 50 60 70 [Width] CLEAN AIR DIRTY AIR STEP FOUR: FILTERED AIR IS DISCHARGED BACK INTO THE WORK AREA. STEP THREE: AIR IS PURIFIED BY PASSING THROUGH A HEPA [99.97% EFFICIENCY ON PARTICLES DOWN TO 0.3 MICRONS IN SIZE], OR ASHRAE FILTER [95% EFFICIENCY ON PARTICLES DOWN TO 0.5 MICRONS IN SIZE], OR ULPA FILTER [99.9995% EFFICIENT ON PARTICLES 0.12 MICRONS AND LARGER]. STEP TWO: AIR IS PROCESSED THROUGH A PRE-FILTER THAT CAPTURES SOME OF THE PARTICLES. STEP ONE: CONTAMINATED AIR IS RELEASED FROM THE APPLICATION BEING PERFORMED WITHIN THE HOOD. Moving a ducted exhaust hood would require disconnecting the hood from the ducting system and the designing a new system at the new location as well as complete re-installation of ductwork, which may require the hiring of outside help to complete. Ductless Fume Hoods are highly convenient and portable: the hood can be easily relocated by simply picking it up and moving it. They can be up and running seconds after re-location. Additionally, ductless fume hoods allow placement and flexibility in hard to duct areas such as the center or bottom level of a multi-story building. Simple Solutions for Cleaner Air Contact Us 1-800-799-4609 www.sentryair.com sales@sentryair.com MADE IN THE USA 2.

Pharmaceutical Compounding Safety Options Sentry Air s Pharmaceutical Compounding Hoods are available in a variety of Standard Sizes. Our engineers also design and manufacture Custom Hoods when requested. PAGE 4 Standard Sizes: 18 Wide Outer Dimensions: 18.5" D x 20" W x 19" H Interior Dimensions: 18" D x 18" W x 18" H Model SS-218-DCH 48-100 CFM. * 24 Wide Model SS-224-DCH Outer Dimensions: 24 D x 26 W x 25 H Interior Dimensions: 23.5 D x 24 W x 24 H 48-100 CFM. 24 Wide- Product High Flow FeaturesModel SS-324-DCH Outer Dimensions: 24 D x 26 W x 25 H Interior Dimensions: 23.5 D x 24 W x 24 H 30 Wide Model SS-330-DCH Outer Dimensions.: 24" D x 32" W x 25" H Interior Dimensions: 23.5" D x 30" W x 24" H Model Numbers: * * With Clear Anti-Static Curtains. In some cases, the actual number may significantly exceed 100 FPM with the addition of curtains. 1.800.799.4609 www.sentryair.com sales@sentryair.com 3.

Pharmaceutical Compounding Safety Options Sentry Air s Pharmaceutical Compounding Hoods are available in a variety of Standard Sizes. Our engineers also design and manufacture Custom Hoods when requested. PAGE 4 Standard Sizes: 40 Wide Outer Dimensions: 24" D x 42" W x 25" H Interior Dimensions: 23.5" D x 40" W x 24" H Model SS-340-DCH 50 Wide Model SS-350-DCH Outer Dimensions: 24" D x 52" W x 25" H Interior Dimensions: 23.5" D x 50" W x 24" H 60 WideProduct FeaturesModel SS-360-DCH Outer Dimensions: 24" D x 62 W x 25" H Interior Dimensions.: 23.5" D x 60" W x 24" H 70 Wide Model SS-370-DCH Outer Dimensions: 24" D x 72 W x 25" H Interior Dimensions: 23.5" D x 70" W x 24" H Model Numbers: * * With Clear Anti-Static Curtains. In some cases, the actual number may significantly exceed 100 FPM with the addition of curtains. 1.800.799.4609 www.sentryair.com sales@sentryair.com 4.

Pharmaceutical Compounding Safety Options Sentry Air s Pharmaceutical Compounding Hoods are available in a variety of Standard Sizes. Our engineers also design and manufacture Custom Hoods when requested. PAGE 4 Standard Sizes: Winged Sentry WORK AREA 9" L x 21" W x 8 H Winged Sentry with Lid WORK AREA WITH LID 9" L x 21" W x 8" H Model SS-200-WS Model SS-200-WSL Winged Sentry Product FeaturesModel SS-300-WS WORK AREA 13.5" L x 28" W x 13 H Winged Sentry with Lid WORK AREA WITH LID 13.5" L x 28" W x 13" H Model Numbers: Up to 100 CFM. Up to 100 CFM. Model SS-300-WSL 1.800.799.4609 www.sentryair.com sales@sentryair.com Sentry Air Systems, Inc., Houston, TX. All rights reserved. Rev.1; February 18, 2011 5.