1 Performance Evaluation of Cleanroom Environmental Systems Tengfang Xu, Lawrence Berkeley National Laboratory Biography Tengfang Xu is a Project Manager currently with the Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory, Berkeley, CA. He obtained his BS and MS degrees from Tsinghua University, Beijing, and a Ph.D. from the University of California, Berkeley. He is a licensed mechanical engineer in California with fifteen years of research and consulting experience in indoor environment, energy, human factors, and building systems. He serves as a Technical Editor for the Journal of the IEST, IL, USA, and is on the Editorial Board for Cleanroom World, China. Abstract This paper presents in-situ measurement results for energy and environmental performance of thirteen cleanroom systems located in the USA, including key metrics for evaluating cleanroom air system performance and overall electric power intensity. Comparisons with the IEST Recommended Practice (IEST-RP-CC012.1) are made to examine the performance of cleanroom air systems. Based upon the results, the paper discusses likely opportunities for improving cleanroom energy efficiency while maintaining effective contamination control. The paper concludes that there are wide variations in energy performance of cleanroom environmental systems, and that performance benchmarking can serve as a vehicle to identify energy efficient cleanroom design practices and to highlight important issues in cleanroom operation and maintenance. Keywords Cleanroom, performance, energy efficiency, environmental system, re-circulation air, make-up air, and benchmarking. Introduction Effective contamination control is the principal reason to operate a cleanroom. Because the purpose of a cleanroom is to control the concentration of airborne particles to minimize undesired existence of particles inside the cleanroom, and to maintain certain environmental conditions [1], environmental systems (HVAC systems) designed for cleanrooms are extremely energy intensive compared to their counterparts in commercial buildings. Some industries use production metrics such as watts per unit of product, which focus on overall production efficiency but overlook the efficiency of energy intensive environmental systems. Since energy generally represents a significant operating cost for cleanroom facilities, improving energy efficiency in cleanrooms can contribute to significant cost savings. Because the number of cleanrooms in the US and around the world has been growing rapidly in the last decade and involves many industries, improvement in energy efficiency is becoming more important.
2 Energy intensity varies with the system design, cleanliness levels [2], cleanroom functions, and critical parameter control such as temperature, humidity, etc. According to an earlier study [3], an estimate of cleanroom electricity intensity for the energy use for cooling and fan energy ranged from 159 kwh/ft 2 to 945 kwh/ft 2, corresponding to different cleanroom classes in California. Depending on cleanroom class, fan power intensity ranged from 5 W/ft 2 to 96 W/ft 2. Derived from the data in the study, fan power use for cleanrooms of ISO es 3, 4, 5 is the most electricity intensive, and collectively accounts for approximately 80% of the fan power use for cleanrooms of all classes in California. A review of studies on cleanroom costs indicated that energy cost could amount to 65-75% of the total annual cost associated with cleanroom operation and maintenance in Europe [4]. Another study conducted a comprehensive review of strategies for energy benchmarking and specifically addressed issues associated with cleanrooms and laboratory-type buildings [5]. A later study indicated that HVAC energy use accounted for 36-67% of the total cleanroom energy use in three facilities in California [6]. There is, however, a lack of data on the energy performance of actual operating cleanroom environmental systems. To better understand the energy performance of existing cleanroom environmental systems in various industries, and to identify opportunities in improving energy-efficiency thereby achieving energy savings, it was necessary to obtain field data and to evaluate how real environmental systems actually perform. The data can also help building owners, operators, and designers to compare energy use of their facility to others. Objective The objectives of this paper are to 1) present benchmarking results on the environmental energy performance of thirteen cleanroom systems; 2) examine the efficiency performance of air systems as compared to the relevant IEST Recommended Practice CC012.1 [7] ; and 3) identify opportunities for improving cleanroom energy efficiency while maintaining or improving cleanroom contamination control. This paper focuses on air system performance, and uses important metrics to assess air system performance and process load intensity. The benchmarking results can serve as a vehicle to identify energy efficient design practices, efficiency innovations, and to highlight important issues in cleanroom operation and maintenance. Approaches The main approach employed was to conduct field measurements and monitoring in the environmental systems serving cleanrooms. To characterize the physical information of each cleanroom system, related system information was compiled based upon a review of building and system drawings, existing balance reports, vendor submittals, energy management systems, and interviews with building engineers. In addition, physical inspections were carried out to locate field measurement points and to collect monitoring data. This study includes field measurements and monitoring of air systems in 13 cleanrooms classified as ISO Cleanliness es 4, 5 and above [1], which roughly correspond to Cleanliness es 10,, and above, respectively, in Federal Standard 209E [8]. Because Federal Standard 209E has been cancelled and the industry is in the transition of adopting the ISO cleanliness classification, limited use of the FS209E cleanliness classification is preserved in this paper. Most of the cleanrooms are located in
3 California in the USA, and the measurements were conducted in 2000 and This paper will not discuss any climatic impact on system performance due to limited information available. Relevant metrics were developed to evaluate air system s energy performance for various designs, cleanliness classes, and processes occurring in the cleanroom. The metrics allow direct comparison of energy intensive systems and components based on design or measured data. Specifically, air system efficiency is defined as the airflow rate per unit of total electricity input (cfm/kw). Since cleanrooms are used for many different activities, there are large variations in process loads. Although a portion of the process heat source may be dealt with directly by the chilled water system, its removal by air systems largely influences the cooling requirements for HVAC systems. To compare process load intensity, process load was characterized based upon the process heat output per unit of primary cleanroom floor area (W/ft 2 ). Table 1 defines key metrics used in this paper. Measurements and Uncertainty Analysis The airflow measurement was made by the use of an electronic flow food with backpressure compensation. The flow hood readings represent local density airflow corrected for barometric pressures. The measurement range is 25-25,000 cfm supply with an accuracy of ±3% from to 2,000 cfm [9]. The total flowrate of supply air was obtained by summing the measured airflow rates through all supply outlets in the cleanrooms. The main limitation to this approach is that in some cleanrooms, a small amount of outlets were not physically accessible by the flow hood. In this case, total supply airflow was obtained based upon extrapolating from measured airflows, the actual number of outlets measured, and the total number of outlets in the cleanroom. It was assumed that uncertainty in summing supply airflow rates was primarily due to the bias in measurements, which would be estimated as ±3%. More conservatively, even with a few inaccessible outlets (e.g., a very small portion accounting for 5% of the total outlets) and with airflow variations among all outlets being very small, we might expect a maximum of ±6% uncertainty in some calculated total supply airflow rate. The electric power measurements and monitoring were made using a portable data logger powered by 12-VDC batteries [10]. The measurement accuracy of electric power and energy is within ±4% with a display range from 1 watt to 60 megawatts (using input ratios). The data logger was installed to take spot measurements of power usage of fans and process under normal operation conditions, and/or to monitor the power usage for a period of time whenever possible. The power usage was observed to be quite constant during the monitoring periods. Given the uncertainties in measured airflow rates and average measured fan power usage, the uncertainty in the measured Re-circulation Air Handler Unit Efficiency is estimated to be about ±8%. If conservatively assuming the uncertainty of estimating floor area as 5% for instance, the uncertainties in the measured power intensity would be approximately ±7%; while the uncertainties in the calculated average cleanroom air velocities and air-change rates would be approximately ±8%.
4 Table 1. Performance Metrics of Cleanroom Systems Metrics Definition Unit Uncertainty Recirculated airflow rate per kw of Re-circulation Air Handler electricity used by all re-circulation air Cfm/kW 8% Unit Efficiency fans Power Intensity for Recirculation Air Handler Unit Cleanroom Air Change Rate Average Cleanroom Air Velocity Make-up Air Handler Unit Efficiency Process Load Intensity Total fan power of re-circulation air handler unit per unit of primary cleanroom floor area Cleanroom airflow rate divided by primary cleanroom volume Cleanroom airflow rate divided by primary cleanroom floor area Make-up airflow rate per kw of electricity used by make-up air fans Process load per unit of primary cleanroom floor area W/ft 2 7% m 3 -air /hr /m 3 -space 8% fpm 8% Cfm/kW 8% W/ft 2 7% Results 1. General Description of the Cleanroom Air Systems This study includes field measurements and monitoring to evaluate the performance of air systems in 13 cleanrooms of various cleanroom cleanliness classes. The cleanroom are mostly located in California. Five of them were ISO -4 cleanrooms, and eight of them were ISO -5 cleanrooms (including one combined with -6). The majority of the energy use in cleanroom HVAC systems is associated with the re-circulation system and to a lesser degree, the make-up air and exhaust systems. This paper presents the results of benchmarking re-circulation systems and make-up air systems in various cleanrooms. Re-circulation air systems recirculate clean conditioned air through high efficiency particulate air (HEPA) or Ultra Low Penetration Air (ULPA) filters for cleanrooms. Re-circulation systems in this study utilize three common designs: a) Fan-tower with pressurized-plenum (FT-PP); b) Distributed re-circulation (DRC) air handler units with ducted-systems; and c) Fan-filter units (FFU). Make-up air systems provide additional fresh air that is drawn from outdoors to replace air lost through exhaust or leakage and thereby maintain certain cleanroom pressure. In a fan tower system, re-circulation air is discharged into a pressurized plenum-type system or through ductwork to HEPA or ULPA filters in the ceiling. FT-PP systems are often most efficient but also may require additional sound attenuation. This adds to the overall system static pressure, which increases the required fan horsepower. In a DRC system serving a specific area of the cleanroom, the re-circulation air is discharged into an open plenum through multiple mid-sized fan units. They may be connected through ductwork, connected directly to plenum ceiling boxes, or connected directly to HEPA filters in the ceiling. DRC systems generally have large air
5 passageways and have lower static pressures and noise levels compared to other types of systems. In fan-filter unit systems, a small fan is integrated with a HEPA or ULPA filter housing which is typically the same size as a ceiling grid. FFU systems have advantages in redundancy, and ease of design and construction. 2. Energy Efficiency for Re-circulation Air Systems Table 2 shows the energy efficiency of different types of re-circulation air systems used to recirculate clean conditioned air for five ISO -4 cleanrooms, seven ISO -5 cleanrooms, and one ISO -5/6 cleanroom. Overall, the system efficiency varied dramatically from cleanroom to cleanroom. Among the five ISO -4 cleanrooms, the efficiency of re-circulation air systems ranged from 3,086 to 4,839 cfm/kw. FT pressurized-plenum systems had fan system efficiencies over 3,000 cfm/kw. This was more efficient than the DRC ducted distributed system tested, which was below 2,000 cfm/kw. Including the -5/6 cleanroom, the efficiency of re-circulation air systems serving ISO -5 cleanrooms ranged from 1,087 to 10,138 cfm/kw. Among these, energy efficiency of the FT pressurized-plenum systems ranged from 4,831 to 10,138 cfm/kw, which was more efficient than their counterparts for cleanrooms of -4 were. This was largely because more space was available for the re-circulation system layout in the -5 cleanrooms, thus reducing air resistance in general. In addition, these FT pressurized-plenum systems were relatively more efficient compared to other types of re-circulation systems (DRC and FFU) serving ISO -5 cleanrooms. This was because in general pressure drops along the FT pressurized-plenum system were lower while pressure drops along the DRC air handler units and FFUs were higher. A study shows that on average the energy effectiveness for three types of re-circulation air systems was W/cfm for a fan tower (with a pressurized-plenum), W/cfm for a distributed RC-AHU, and W/cfm for a fan-filter unit [11]. These translate into the energy efficiency metric defined here as the following: 5,952 cfm/kw for the fan-tower (pressurized-plenum), 4,950 cfm/kw for the DRC air handler units, and 4,717 cfm/kw for the FFUs. A state-of-the-art fan-filter unit with an electronically commutated DC motor operates more efficiently (as much as 60 percent) than do models with conventional motors [12]. Compared to these, the fan-filter units and distributed RC-AHUs in this study were rather inefficient in energy performance, ranging from 1,276 to 2,374 cfm/kw (for FFUs), and from 1,087 to 2,214 cfm/kw (for DRC systems). It should however be pointed out that for FFUs, the total fan energy use also includes the fan energy used to transport the conditioned air in addition to the energy use directly by fan-filter units. Although this study did not provide further measurements to identify major reasons for the huge variations in energy efficiency, the lower energy efficiency illustrated in FFU systems was likely due to factors such as inefficient motors, inefficient design, and/or layout of the re-circulate pathways, or some combination of these factors. In contrast, systems with fan tower pressurized plenums were much more efficient.
6 Table 2. Performance Data of Re-circulation Air Systems Cleanroom Cleanroom Cleanliness Cleanliness (FS 209E [8] RC-AHU RC-AHU Efficiency RC-AHU Power ) (ISO [1] Airflow Type (Cfm/kW) Intensity (W/ft ) 2 ) 4 10 FT-PP FT-PP FT-PP FT-PP DRC FFU FFU FT-PP FT-PP FT-PP DRC DRC /6 /0 FFU Energy Efficiency for Make-up Air Systems Outdoor air supply is needed to make-up exhaust (general exhaust, heat exhaust, process exhaust, etc.) and exfiltration to maintain pressurization associated with the cleanroom. Figure 1 shows the measured energy efficiency of ma ke-up air systems along with the re-circulation air systems of for three ISO -4 cleanrooms and eight ISO -5 cleanrooms and above. Except for two ISO -5 cleanrooms, the energy efficiency of make-up air systems overall was much lower than that of the recirculation air systems (by a factor of up to 18) serving the same cleanrooms. This was probably because of greater pressure losses along the make-up air pathways, which were likely caused by a combination of longer duct runs, more-confined space available for efficient duct layouts, and lessefficient fans or motors. Including the -5/6 cleanroom, the efficiency of make-up air handler units in ISO -5 cleanrooms ranged from around 540 up to 1,800 cfm/kw. Unlike re-circulation systems, the make-up air systems efficiency varied less dramatically from cleanroom to cleanroom (by a factor of up to 3 for both cleanliness classes combined). All of these indicate that the energy efficiency of makeup air systems can be improved by integrating mechanical design with architectural design at early stage of the project, and by adopting fans and motors that are more efficient.
7 Energy Efficiency of Make-Up and Recirculation AHUs (cfm/kw) Re-circulation Air System Make-up Air System N/A N/A 10, Recirculation AHU, Fan Filter, Fan Filter, Pressurized Plenum, Pressurized Plenum, Pressurized Plenum, Recirculation AHU, Recirulation AHU /0 Fan Filter Figure 1. Energy efficiency for make-up air and re-circulation air systems 4. Fan Power Intensity for Re-circulation Air systems Table 2 also includes the measured fan power intensity of re-circulation air systems for the same five ISO -4 cleanrooms and seven ISO -5 cleanrooms and one ISO -5/6 cleanroom. Overall, fan power intensity varied dramatically from cleanroom to cleanroom. Among ISO -4 cleanrooms, fan power intensity of the re-circulation air handler units ranged from approximately 16 to 38 W/ft 2. Including the ISO -5/6 cleanroom, the fan power intensity of re-circulation air handler units in ISO -5 cleanrooms ranged from approximately 3 to 24 W/ft 2. This indicates that power intensity for various re-circulation air systems for cleanrooms of the same cleanliness class can differ by more than a factor of eight. In ISO -5 cleanrooms, FFUs and DRC units on average used more fan power per cleanroom area than pressurized-plenum systems did. Compared with the same types of systems (e.g., pressurized plenum) for the cleanrooms studied, the measured intensities indicate that re-circulation fan power intensity was greater for higher cleanliness levels, whereas the efficiency decreased accordingly. The findings indicate that it is important for designers not to specify higher cleanroom cleanliness than is needed for a specific cleanroom process. Designing and operating a cleanroom with higher cleanliness levels than needed would increase fan power demand and would be less economical to operate.
8 The electrical demand (kw) for fan power at the same time is, however, largely affected by system design and process equipment needs, in addition to the requirements for cleanroom cleanliness. From the performance data discussed, one can easily see the wide variations of energy efficiency even among cleanrooms of same cleanliness class. This was largely due to the system design and space allocation. Furthermore, the design details and layout alone can sometimes dictate the magnitude of overall air system efficiency, regardless of the cleanroom cleanliness level. For example, the recirculation system efficiency for cleanrooms with a more stringent cleanliness level (e.g., ISO -4 with a distributed re-circulation system) turned out to be more efficient than those with lower cleanliness levels (e.g., ISO -5 with a distributed system). This confirms that air system design and space allocation can play a significant role in affecting the system efficiency. The implications from the findings for cleanroom system design are that carefully reducing resistance in the air path throughout air systems can lower pressure drops, and thus require less power and energy to recirculate the air needed to maintain contamination control. From a design point of view, the planning and eventual design of the cleanroom should provide necessary adjacencies and space for efficient air systems and components. 5. Process Loads Cooling load required to remove process heat is one of the major considerations during the design and operation of HVAC systems. The amount of process load varies significantly from cleanroom to cleanroom. How to estimate process loads in order to accurately size HVAC systems often presents a design challenge. These systems are frequently oversized due to inaccurate heat load or load diversification assumptions. A portable power data logger was used to measure electric power of process tools in the cleanrooms. The spot measurements usually lasted for a short period of time during normal operation, for which the power usage was considered relatively constant. Figure 2 illustrates the measured process load intensity within some of the cleanrooms. Depending upon the process activities, the process load intensity ranged from 4 to 26 W/ft 2 among six ISO -5 cleanrooms, and from 36 to 49 W/ft 2 in two ISO -4 cleanrooms. These were generally quite low compared to many cleanrooms that are designed for design load intensities between 75 and 125 W/ft 2. While the magnitude of process loads is dependent on cleanroom activities, the measured results suggest a strong likelihood that process loads were often over-estimated and that HVAC systems have been commonly over-sized. Although over-sizing may be intentional for additional reasons such as the provision for future expansion, reliability, etc., tendencies to add extra conservatism in the design process often result in extra energy waste. The result shown above confirms that process generated heat load tends to be over-estimated in practice and therefore HVAC systems are oversized. The design implication from this benchmarking analysis is that it is necessary and critical to have more accurate estimates of process load for designing an energy efficient environmental system.
9 Process Load Density (W/ft 2 ) N/A N/A N/A N/A /0 Figure 2 Cleanroom process load density (W/ft 2 ) 6. Cleanroom Air Change Rates and Average Air Velocities Simply to relate a cleanliness class level to a specific cleanroom air velocity is a prohibitively complex task due to the number of factors involved. For example, the operating protocol, flow direction, filter performance, equipment and space configuration all have direct or indirect impact on cleanliness level given the same cleanroom air velocity. Unfortunately, there is a lack of scientific basis for determining an optimal cleanroom air change rate. The Institute of Environmental Science and Technology recommends a range of air change rates between 300 and 540 m 3 -air/hr. m 3 -space for ISO -4 (-10) cleanrooms for a unidirectional airflow pattern [7]. The air change rates correspond to cleanroom air velocities between 50 and 90 fpm (or m/s) based upon a ceiling height of 10 ft and full ceiling coverage. Similarly, the IEST also recommends a range for air change rates between 240 and 480 m 3 -air/hr. m 3 -space for ISO -5 (-) cleanrooms, which correspond to cleanroom air velocities between 40 and 80 fpm (or m/s) for any airflow pattern (unidirectional, non-directional, and mixed) [7]. These ranges were originally established based on design of earlier cleanrooms built to support the space program before the 1970s. ASHRAE [13] indicates that circulation rates around 90 cfm per square foot, which equals cleanroom air velocities of 90 fpm (or 0.46 m/s) on average for full ceiling coverage, are usual for ISO -5 (-) or cleaner cleanrooms. A recent study [14] recommended 70- fpm for
10 cleanrooms of ISO -1 through 5, and provided a low range of air change rate (up to 275 m 3 -air/hr. m 3 -space) for ISO -5 through 8. Apparently, there have been conflicting guidelines and acceptable ranges, however, none of the above provided a scientific basis for the recommendations. In practice, acceptable contamination levels have been achieved with either significantly lower or higher than recommended air change rates. There is some confusion among designers and operators in use of recommendations or guidelines, rules of thumb, and their actual operating experience. Air Change Rate (1 m 3 air / hr /m 3 space) IEST recommended range of air change rates for ISO -4 (FED ) Air Change Rate Cleanroom Air Velocity IEST recommended range of air change rates for ISO Average Cleanroom Air Velocity (fpm) 0 10, Recirculation AHU, Fan Filter, Fan Filter, Pressurized Plenum, Pressurized Plenum, Pressurized Plenum, Recirculation AHU, Recirulation AHU /0 Fan Filter 0 Figure 3. Actual air change rates and cleanroom air velocities as compared to IEST recommended values [7] The in-situ measurements provide data to indicate how the re-circulation system actually performed. Figure 3 shows the actual air change rates and average air velocities for the cleanroom measured. For the five cleanrooms of ISO -4 (-10), the measured air change rates were 385, 474, 516, 591, and 678 m 3 -air/hr. m 3 -space, respectively, corresponding to average air velocities between 58 fpm (0.30 m/s) and 118 fpm (0.60 m/s). This indicates that there was a large variation in recirculation air supply among different systems, depending on design, layout, and cleanroom activities. Obviously, some of these exceeded higher limit that IEST recommended. Energy saving opportunities might well exist in the meanwhile. For example, reducing the re-circulation air supply by 10% and 20% for the cleanrooms with air change rates of 591 and 678 m 3 -air/hr. m 3 -space, respectively, could bring down the air change rates below or around 540 m 3 -air/hr. m 3 -space, which is near the upper limit
11 recommended by IEST for -4 cleanrooms. The reduction of airflow rates would then in theory curtail re-circulation fan power by up to 30-50% while complying with the recommended air change rates. In addition, the decrease of fan power use to re-circulate cleanroom air would also reduce the overall cooling load, which would otherwise induce extra heat generated from fan operation. For the ISO -5 cleanrooms, the measured air change rates ranged from 98 up to 479 m 3 -air/hr. m 3 -space, corresponding to average air velocities between 20 fpm (0.10 m/s) and 80 fpm (0.40 m/s). The majority of the air change rates fell below the recommended lower limit of 240 m 3 -air/hr. m 3 -space. Although generalization of these findings may be premature based upon the limited number of cleanrooms tested, these findings indicate that there were practical opportunities in certain ISO -5 (-) cleanrooms to control airflow below the IEST recommended range of 240 to 480 m 3 -air/hr. m 3 -space. This also indicates that certain cleanrooms may have particular challenges in producing airflows lesser than the typical range recommended by IEST. Conclusions Benchmarking energy performance of mechanical systems and components provides rich information on the system and component performance. Analysis of energy metrics can provide better understanding of system performance, and can suggest energy efficient design practices and long-lasting energy-saving opportunities in cleanrooms. The energy performance evaluation can help to prioritize measures to achieve improvements in system energy efficiency. Specifically, the following are the major conclusions. Energy efficiency and fan-power density for re-circulation air systems and make-up air systems varied widely, even among cleanrooms of the same cleanliness classes. We have found potential energy savings opportunities by reducing circulation airflow rates while still meeting the air change rates recommended by IEST. In addition, the decrease of fan power needed to recirculate cleanroom air will also reduce the overall cooling load, which would otherwise introduce extra heat from fan operation. Like optimizing system design and components, carefully arranging system and process layouts can have lasting and benign impact on energy use of air systems. These findings may indicate that the operating air change rates required for the ISO -5 (-) cleanrooms tested in this study were less than the 240 to 480 m 3 -air/hr. m 3 -space as recommended by IEST. In general, air systems with lower pressure drops (lower resistance to flow) along the return air paths have higher efficiency (cfm/kw) than those with higher air pressure drops. Fan-tower type recirculation systems with a pressurized plenum providing air to the cleanroom ceiling filters usually result in better efficiency than using separate ductwork to each of the ceiling filters. From a design point of view, the planning and design of the cleanroom systems should provide necessary adjacencies and space for efficient air systems and components. The benchmarking analysis provides actual data on process loads that were considerably below typical design values used by designers. This suggests that it is necessary and important for designer to obtain more accurate process loads and their diversification; and to avoid oversizing HVAC systems as a result.
12 Recommendations To maximize the usefulness of benchmarking efforts, it will be necessary to obtain more data by benchmarking additional cleanrooms and by integrating available measured field data. Once a statistically sound dataset is available, building operators will be able to compare performance of their cleanroom facilities with others. Future research may include investigations of continuous energy performance as compared to the design intent. In addition, there is a need to develop a benchmarking tool that allows computer interface to compare cleanroom energy performance to a large sample of similar cleanrooms. This will be helpful for identifying good design practices and potential energy-saving opportunities. The findings of lower cleanroom air change rates in actual cleanrooms than those recommendations specified by IEST, ASHRAE, and other literatures indicate that reviewing those air change recommendations to include energy considerations and associated challenges may be useful. Acknowledgments This paper is partially derived from the database produced by an LBNL research project [15]. The project was funded, in part, by the California Institute for Energy Efficiency (CIEE), a research unit of the University of California. Publication of research results does not imply CIEE endorsement of or agreement with these findings, nor that of any CIEE sponsor. This work was also supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technologies Program of the U.S. Department of Energy under Contract No. DE-AC03-76SF Special thanks are extended to Pacific Gas and Electric Company for the permission of using the benchmarking data. This paper benefited from review comments provided by William Tschudi of LBNL, Christopher Humphrey of Asyst Technologies, Inc., and a number of anonymous individuals. References [1] International Organization for Standardization (ISO) ISO/DIS Cleanrooms and associated controlled environments. Part 1: ification of air cleanliness. The Institute of Environmental Sciences and Technology (IEST), 5005 Newport Drive, Rolling Meadows, Illinois , USA. [2] International Organization for Standardization (ISO) ISO/DIS Cleanrooms and associated controlled environments. Part 2: Testing and monitoring to prove continued compliance to ISO/DIS The Institute of Environmental Sciences and Technology (IEST), 5005 Newport Drive, Rolling Meadows, Illinois , USA. [3] Mills, Evan, G. Bell, D. Sartor, A. Chen, D. Avery, M. Siminovitch, S. Greenberg, G. Marton, A. de Almeida, and L.E. Lock Energy Efficiency in California Laboratory Type Facilities. Lawrence Berkeley National Laboratory Report, LBNL [4] Whyte, W Cleanroom Design, 2 nd Edition. John Wiley & Sons, Baffins Lane, Chichester, West Sussex, England. ISBN [5] Sartor, D., M.A. Piette, W. Tschudi, and S. Fok Strategies for Energy Benchmarking
13 in Cleanrooms and Laboratory-Type Facilities, Proceedings of the ACEEE 2000 Summer Study on Energy Efficiency in Buildings, CA. August LBNL [6] Tschudi, W., K. Benschine, S. Fok, and P. Rumsey Cleanroom Energy Benchmarking in High-Tech and Biotech Industries. Proceedings of American Council for an Energy Efficient Economy (ACEEE) Summer Study on Energy Efficiency in Industry, Increase Productivity through Energy Efficiency, Vol. 1: , NY. June [7] The Institute of Environmental Sciences and Technology (IEST) Considerations in Cleanroom Design. IEST Recommended Practice (IEST-RP-CC012.1). The Institute of Environmental Sciences and Technology, 940 East Northwest Highway, Mount Prospect, Illinois , USA. [8] Federal Standard 209E Airborne Particulate Cleanliness es in Cleanrooms and Clean Zones. General Services Administration (GSA), GSA Service Center, Seventh & D Street, SW, Washington DC, USA. This standard has been superseded, starting on November 29, 2001, by International Organization for Standardization (ISO) Standards for Cleanrooms and associated controlled environments, ISO & 2 [1, 2]. [9] Shortridge Instruments, Inc.: Flowhood CFM E. Redfield Rd., Scottsdale, AZ , U.S.A. Phone (480) , [10] Summit Technology Inc.: PowerSight PS3000. Walnut Creek, CA [11] Grout, R Air Management. CleanRooms. PennWell Corporation, March [12] Galatowitsch, S When fan filter units are the right call, CleanRooms. PennWell Corporation, January [13] ASHRAE ASHRAE Handbook: HVAC Applications, American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc., Atlanta, GA. [14] Schneider, R Designing Clean Room HVAC Systems. ASHRAE Journal, Vol. 43 (8): August [15] Xu, T., W. Tschudi, G. Bell, E. Mills, and D. Sartor High-Tech Buildings Market Transformation Project: Cleanroom Energy Benchmarking; High-Performance Fume Hood Demonstration/Test; Market Transformation Activities. Lawrence Berkeley National Laboratory (LBNL), LBNL-49112, Berkeley, CA, USA, November 2001.
HVAC Air Systems. Recirculation Air System Types
HVAC Air Systems Recirculation Air System Types Summary Recirculation air handler fan energy can account for 10 to 30% of total cleanroom energy use. There are three fundamental recirculation system configurations:
How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems
How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems Paul Mathew, Ph.D., Staff Scientist Steve Greenberg, P.E., Energy Management Engineer
Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc.
Business Management Magazine Winter 2008 Hot Air Isolation Cools High-Density Data Centers By: Ian Seaton, Technology Marketing Manager, Chatsworth Products, Inc. Contrary to some beliefs, air is quite
FS209E and ISO Cleanroom Standards
FS209E and ISO Cleanroom Standards Terra Universal is the leading expert in the design and fabrication of critical-environment applications. We offer a complete range of equipment, furnishing and supplies
Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging
NEUDORFER ENGINEERS, INC. provides our customer with unbiased, professional, performance testing of Cleanrooms. We are committed to providing you, our customer, with value-added expertise in an effort
Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions 6-28-10. Sponsored by:
Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions 6-28-10 Sponsored by: Disclaimer This document was prepared as an account of work sponsored by the United States Government.
Demand Based Static Pressure Reset Control for Laboratories
LLC Demand Based Static Pressure Reset Control for Laboratories Laboratories are generally the largest users of energy in any facility. Whether in a pharmaceutical research facility, a university or a
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers
Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By Lawrence Berkeley National Laboratory
SPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
Guide to Minimizing Compressor-based Cooling in Data Centers
Guide to Minimizing Compressor-based Cooling in Data Centers Prepared for the U.S. Department of Energy Federal Energy Management Program By: Lawrence Berkeley National Laboratory Author: William Tschudi
Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory
Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory Title: Energy Implications of Economizer Use in California Data Centers Author: Shehabi, Arman Publication Date: 09-23-8 Permalink:
VAV Laboratory Room Airflow The Lowdown on Turndown
Technology Report March, 2003 VAV Laboratory The Lowdown on Turndown Turndown comparison of these two turndown ratios. Note the small actual airflow difference between them. control ranges are normally
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001
Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001 Presented by: Liberty Engineering, LLP 1609 Connecticut Avenue
MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS
MAC 10 Original & IQ FAMILY OF FAN FILTER UNITS used in: microelectronics medical device semiconductor disk drive laboratory pharmaceutical markets hospitals clean rooms Table of Contents MAC 10 Original
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia
Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia Prepared for the U.S. Department of Energy s Federal Energy Management Program
Increasing Energ y Efficiency In Data Centers
The following article was published in ASHRAE Journal, December 2007. Copyright 2007 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems
HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems Fundamental Principles of Environmentally Responsible, Energy Efficient Buildings 1. Energy efficiency is
International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS
International Telecommunication Union ITU-T TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU Technical Paper (13 December 2013) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES
NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES 8.1 INTRODUCTION Testing, adjusting, and balancing of HVAC systems can best be accomplished by following a series of systematic procedures. The NEBB TAB
SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP
research journal 2013 / VOL 05.01 www.perkinswill.com SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP ARCHITECTURE AND ENGINEERING OF SUSTAINABLE BUILDINGS Current Trends in Low-Energy HVAC Design
LOW-PRESSURE-DROP HVAC DESIGN FOR LABORATORIES
L a b o r a t o r i e s f o r t h e 2 1 s t C e n t u r y : B e s t P r a c t i c e s LOW-PRESSURE-DROP HVAC DESIGN FOR LABORATORIES Introduction Laboratory ventilation systems are designed to isolate
Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested
DOP Solutions Technical Document: Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested Issue 1: Prepared by Neil Stephenson and Tim Triggs and edited by
Improving Data Center Efficiency with Rack or Row Cooling Devices:
Improving Data Center Efficiency with Rack or Row Cooling Devices: Results of Chill-Off 2 Comparative Testing Introduction In new data center designs, capacity provisioning for ever-higher power densities
Energy Efficient High-tech Buildings
Energy Efficient High-tech Buildings Can anything be done to improve Data Center and Cleanroom energy efficiency? Bill Tschudi Lawrence Berkeley National Laboratory [email protected] Acknowledgements California
Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues
LBNL-6129E ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY Modeling and Simulation of HVAC Faulty Operations and Performance Degradation due to Maintenance Issues Liping Wang, Tianzhen Hong Environmental
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers
Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers Prepared for the U.S. Department of Energy s Federal Energy Management Program Prepared By Lawrence Berkeley National
CHAPTER 4 VENTILATION
CHAPTER 4 VENTILATION SECTION 401 GENERAL 401.1 Scope. This chapter, in conjunction with the building code, shall govern the ventilation of spaces within a building intended to be occupied. Mechanical
Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks
Presentation Outline Common Terms / Concepts HVAC Building Blocks Plant Level Building Blocks Description / Application Data Green opportunities Selection Criteria Air Distribution Building Blocks same
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER
DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER DATA CENTERS 2009 IT Emissions = Aviation Industry Emissions Nations Largest Commercial Consumers of Electric Power Greenpeace estimates
Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com
Cooling Small Server Rooms Can Be Inexpensive, Efficient and Easy - Jim Magallanes Computer Room Uptime: www.cruptime.com Uptime Racks: www.uptimeracks.com Server Rooms Description & Heat Problem Trends
ASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
CLEAN ROOM MONITORING REGULATORY STANDARDS
CLEAN ROOM MONITORING REGULATORY STANDARDS Air Classification as per Schedule M Maximum permitted number of particles / m3 equal or above at rest in operation 0.5µm 5.0µm 0.5µm 5.0µm A 3,520 29 3,500 29
How to Measure HVAC System Airflow
How to Measure HVAC System Airflow About National Comfort Institute National Comfort Institute is an international training Since our and beginning development in 1994 company we have trained with and
HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.
HVAC Systems and Indoor Air Quality Douglas K. Spratt, M.Sc., P.Eng. The 5 Senses Architecture Electrical Structural Mechanical Hearing Seeing Smelling Feeling Tasting HVAC Systems are Dynamic Heat Gains
Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Kenneth G. Brill, Upsite Technologies, Inc. Lars Strong, P.E., Upsite Technologies, Inc. 505.798.0200
WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1
WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City Prov Postal code Phone ( ) Fax ( ) Designer/Signature:
UNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS
DATA CENTERS Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS COSTLY FAN ENERGY REDUCED BY CAMFIL PREMIUM PRODUCTS = COST SAVINGS Power Usage Effectiveness (PUE) is an important metric
The Different Types of Air Conditioning Equipment for IT Environments
The Different Types of Air Conditioning Equipment for IT Environments By Tony Evans White Paper #59 Executive Summary Cooling equipment for an IT environment can be implemented in 10 basic configurations.
Using Simulation to Improve Data Center Efficiency
A WHITE PAPER FROM FUTURE FACILITIES INCORPORATED Using Simulation to Improve Data Center Efficiency Cooling Path Management for maximizing cooling system efficiency without sacrificing equipment resilience
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
High Efficiency Particulate Air (HEPA) Filter Velocity Reduction Study
High Efficiency Particulate Air (HEPA) Filter Velocity Reduction Study International SEMATECH Manufacturing Initiative Advanced Materials Research Center, AMRC, International SEMATECH Manufacturing Initiative,
Power and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers White Paper #46 Introduction The Problem Average rack in a typical data center is under 2 kw Dense deployment of blade servers (10-20 kw
Example Retrocommissioning Measure: Opening Throttled Discharge Valves
Opening Throttled Discharge Valves This 21-story building, constructed in 1997, is located in Oregon and contains 589,000 gross square feet of mostly office occupancy. The HVAC system includes six large
Residential Duct Systems for New and Retrofit Homes
Residential Duct Systems for New and Retrofit Homes Why it is important to properly design and install high quality, efficient ducted air systems? The efficiency of air distribution systems has been found
CLASSIFICATION OF CLEANROOMS
CLASSIFICATION OF CLEANROOMS Cleanrooms are classified by the cleanliness of their air. The method most easily understood and most universally applied is the one suggested in the earlier versions (A to
High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.
High Density Data Centers Fraught with Peril Richard A. Greco, Principal EYP Mission Critical Facilities, Inc. Microprocessors Trends Reprinted with the permission of The Uptime Institute from a white
Managing Data Centre Heat Issues
Managing Data Centre Heat Issues Victor Banuelos Field Applications Engineer Chatsworth Products, Inc. 2010 Managing Data Centre Heat Issues Thermal trends in the data centre Hot Aisle / Cold Aisle design
ENHANCED LABORATORY HVAC SYSTEM
ENHANCED LABORATORY HVAC SYSTEM INTRODUCTION Since the early 1980's the attention to more energy efficient laboratory designs has been on the rise due to the increase in energy cost and the emergence of
The Data Center Dilemma - A Case Study
Second Place: Industrial Facilities or Processes, Existing The TCS data center makes use of white cabinets and reflective surfaces as one method to reduce power for its lights and cooling. Data Center
Ventilation Standard For Health Care Facilities
The following article was published in ASHRAE Journal, October 2008. Copyright 2008 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects
Makeup Air For Exhaust Systems In Tight Houses Tony Jellen Engineering Projects PA Housing & Land Development Conference February 23, 2012 Effects of Kitchen Ventilation on Residential Dwellings Anthony
Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions
Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions M. Liu, Y. Zhu, D. E. Claridge Energy Systems Laboratory Texas A&M University Ed. White Energy Management Operation
Effect of Rack Server Population on Temperatures in Data Centers
Effect of Rack Server Population on Temperatures in Data Centers Rajat Ghosh, Vikneshan Sundaralingam, Yogendra Joshi G.W. Woodruff School of Mechanical Engineering Georgia Institute of Technology, Atlanta,
HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
Analysis of data centre cooling energy efficiency
Analysis of data centre cooling energy efficiency An analysis of the distribution of energy overheads in the data centre and the relationship between economiser hours and chiller efficiency Liam Newcombe
Innovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
HVAC Calculations and Duct Sizing
PDH Course M199 HVAC Calculations and Duct Sizing Gary D. Beckfeld, M.S.E., P.E. 2007 PDH Center 2410 Dakota Lakes Drive Herndon, VA 20171-2995 Phone: 703-478-6833 Fax: 703-481-9535 www.pdhcenter.com An
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory
Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings
WHITE PAPER Cooling Capacity Factor (CCF) Reveals Stranded Capacity and Data Center Cost Savings By Lars Strong, P.E., Upsite Technologies, Inc. Kenneth G. Brill, Upsite Technologies, Inc. 505.798.0200
Preliminary Final Proposal
1 Butler Memorial Hospital New Inpatient Tower Senior Capstone Project Mechanical Option Preliminary Final Proposal Mechanical System Re-design and Breadth Topics Butler Memorial Hospital New Inpatient
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
EnergyPro Building Energy Analysis. Assisted Living Building
EnergyPro Building Energy Analysis Assisted Living Building EnergyPro Building Energy Analysis for an assisted living building Project Scope The purpose of the EnergyPro energy model was to evaluate the
Elements of Energy Efficiency in Data Centre Cooling Architecture
Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total
SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR. www.sentryair.com 1.800.799.
SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR 1.800.799.4609 www.sentryair.com Pharmaceutical Compounding Safety Solutions Sentry Air Systems
Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade
Robert McCabe Director, Health Care Solutions HTS Chicago Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade Biography Robert McCabe has been involved in commercial
Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance
DC Pro Assessment Tools. November 14, 2010
DC Pro Assessment Tools November 14, 2010 William Tschudi, PE Lawrence Berkeley National Laboratory [email protected] 510-495-2417 1 Slide 1 Assessment tools LBNL is developing tools to assist in performing
HVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages
Objectives Increase awareness of the types of economizers currently used for data centers Provide designers/owners with an overview of the benefits and challenges associated with each type Outline some
85 F 80 F 50% 75 F 70 F 73.0/61.8 45 F 10% Figure 1
Feb. 07 INTRODUCTION: Wrap around heat pipes are air-to-air heat exchangers that are installed in the airstream upstream and downstream of a cooling coil to deliberately reduce the Sensible Heat Ratio
Rate of Heating Analysis of Data Centers during Power Shutdown
2011. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Published in ASHRAE Transactions, Volume 117, Part 1. For personal use only. Additional reproduction,
Variable-Speed Fan Retrofits for Computer-Room Air Conditioners
Variable-Speed Fan Retrofits for Computer-Room Air Conditioners Prepared for the U.S. Department of Energy Federal Energy Management Program Technology Case Study Bulletin By Lawrence Berkeley National
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
Ductless Heat Pumps. Gary Nordeen January 2009. www.nwbuildings.org/dhp.aspx [email protected]
Ductless Heat Pumps Gary Nordeen January 2009 www.nwbuildings.org/dhp.aspx [email protected] Outline Heat Pump Basics Ductless Heat Pumps Efficiency Advantages Commercial installations Planning (applications,
Cooling Audit for Identifying Potential Cooling Problems in Data Centers
Cooling Audit for Identifying Potential Cooling Problems in Data Centers By Kevin Dunlap White Paper #40 Revision 2 Executive Summary The compaction of information technology equipment and simultaneous
DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences
DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences November 2011 Powered by DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no
Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program
Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Indoor air quality Workers and students spend about half their waking hours at work or school. Therefore, maintaining adequate indoor air quality
Energy Efficiency. Energy Efficient Home Cooling:
Energy Efficiency Energy Efficient Home Cooling: Choosing an air conditioning system is an important decision. A poor choice may be costly to purchase and operate and yet fail to provide the desired cooling
Reducing the Annual Cost of a Telecommunications Data Center
Applied Math Modeling White Paper Reducing the Annual Cost of a Telecommunications Data Center By Paul Bemis and Liz Marshall, Applied Math Modeling Inc., Concord, NH March, 2011 Introduction The facilities
FIRE DAMPER APPLICATION GUIDE
FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire
HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.
Reducing Building HVAC Costs of site rec By Stephen J. Pargeter Building owners are caught between two powerful forces the need to lower energy costs and the need to meet or exceed outdoor air ventilation
Mechanical Insulation. Hospitals and Schools
Study on Mechanical Insulation in Hospitals and Schools March 1, 2011 Study Mechanical Insulation in Hospitals and Schools G. Christopher P. Crall, P.E. Ronald L. King Executive Summary Mechanical insulation
Dealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe [email protected] AGENDA Business Drivers Challenges
Data Centers. Comparing Data Center & Computer Thermal Design
Data Centers Comparing Data Center & Computer Thermal Design By Michael K. Patterson, Ph.D., P.E., Member ASHRAE; Robin Steinbrecher; and Steve Montgomery, Ph.D. The design of cooling systems and thermal
Creating Efficient HVAC Systems
Creating Efficient HVAC Systems Heating and Cooling Fundamentals for Commercial Buildings Heating, ventilating, and air conditioning (HVAC) systems account for nearly half of the energy used in a typical
Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.
Product Sampler #1 Laminar Flow Hoods / Laminar Flow Cabinets: 1- Benchtop Vertical Laminar Flow Hoods- Air Recirculation Available s: Clean Bench Class 100 Bench-top Vertical Laminar Flow Hoods with Air-recirculation
AbSTRACT INTRODUCTION background
february 20, 2007 GREEN GRID METRICS: Describing Datacenter Power Efficiency Technical Committee White Paper white paper 1 Abstract The Green Grid is an association of IT professionals seeking to dramatically
Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas
Methods for Effective Room Air Distribution Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Agenda Overview LEED issues and Update Perimeter Acoustics Thermal Comfort IAQ / Standard 62.1 Update
By Donald Fisher, P.Eng., Associate Member ASHRAE
By Donald Fisher, P.Eng., Associate Member ASHRAE Decisions to purchase a commercial kitchen ventilation (CKV) system often are based on rule-of-thumb estimates using a $/cfm index (i.e., annual energy
THE GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCiE
THE GREEN GRID DATA CENTER POWER EFFICIENCY METRICS: PUE AND DCiE 2007 The Green Grid. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted, or stored in any