LAMINAR AIRFLOW EQUIPMENT CLASS I BIOLOGICAL SAFETY CABINETS BIOLOGICAL ENCLOSURES
|
|
|
- Daniella Nelson
- 9 years ago
- Views:
Transcription
1 LAMINAR AIRFLOW EQUIPMENT CLASS I BIOLOGICAL SAFETY CABINETS BIOLOGICAL ENCLOSURES NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A
2 Sustainability We at NuAire continually strive to improve our responsibilities to the economy, environment, social communications, and our customer satisfaction. Our commitment extends to purchasing or using products that reduce energy consumption, reduce environmental impact, minimize pollution and make use of recycled content that will not deplete natural resources. We continually use more recycled materials in our cabinets through both design and supplier parts and process improvements. The following chart represents our current level of sustainability for Biological Safety Cabinets. General Cabinet Component Description % Content by Weight % of Recycled Material used in Manufacturing % Recyclable Stainless Steel 75% 80% 100% Mild Steel 10% 10% 100% Copper 2% 0% 100% Aluminum 2% 50% 100% Glass 3% 0% 100% Electronics 1% 0% 25% Filter Media 1% 0% 0% Misc. Plastic Parts 1% 0% 0% Packing Materials 5% 60% 95% 100% BSC 65% 97%
3 NU-301 NU-813 NU-101 NU-114 NU-112 NU-126 NU-125 NU-819 NU-201 NU-105 1
4 Improved Principles of Laminar Airflow Designs Unidirectional airflow moving along parallel flow lines at a constant velocity minimizes air turbulence within the work area. UNIFORM AIRFLOW Ergo: Work Nomos: The Study or Laws of. Combines to mean: The Laws of Work This unique airflow system eliminates the possibility of structural or gasket leaks. Optimum Air Volume Creates A Safe Environment Selection of specific motor/blower, HEPA filter(s), materials, electronics, work space and plenum sizes creates a crucial combination of elements providing an optimal air volume for personnel, product, and environmental protection. Larger, Long Lasting HEPA Filters NuAire hand selects and tests each HEPA filter to ensure the integrity of the system. Our HEPA filters are typically larger and therefore last longer than those in most competitive products. Motor/Blower System Extends HEPA Filter Life As the HEPA filter loads, the motor/blower system automatically compensates to assure optimum performance and extended filter life. The Attenumount vibration control system provides extraordinary attenuation of sound and vibrations. Centrally Located Control Center with State-of-the-art Electronic Control System Each NuAire product utilizes the most advanced and reliable electronic technology available at the time the product is manufactured. Registered to: ISO 9001:2008 ISO 13485:2003 NuAire designs equipment that accommodates advancement for: improved safety conditions; improved productivity; improved quality and reliability; and reduction of arm, shoulder, and neck strain contributing to common work place injuries. Ergonomically-designed equipment improves productivity, quality, and reliability. Expanded vision zone, large work area, properlighting for reduced glare, forearm support for comfort and safety, and maximum knee/thigh clearance are just a few of the many ergonomic features designed into each NuAire product. ALL NUAIRE PRODUCTS meet or exceed ISO Std Class 5 for Air Quality Conditions. ISO , Cleanrooms and associate controlled environments - Part 7: Separative devices (clean air hoods, gloveboxes, isolators and minienvironments) is an international standard outlining the performance requirements of Separative devices. This part of ISO specifies the minimum requirements for the design, construction, installation, testing, and approval of separative devices. Separative devices range from open to closed systems. ISO FED-STD-209E * * In 2000, ISO was published, which began the process of FED-STD- 209E being cancelled. The U.S. General Services Administration (GSA) released a Notice of Cancellation for FED-STD-209E, Airborne Particulate Cleanliness Classes in Cleanrooms and Clean Zones, on November 29, 2001 and FED-STD-209E was then superseded by ISO and ISO ISO Class English ,000 10, ,000 Metric M1.5 M2.5 M3.5 M4.5 M5.5 M
5 Custom Engineered Enclosures NuAire delivers a custom product to the customer that is cost effective, exceeds their requirements, delivers product on-time, and increases productivity and profitability. NuAire has designed and manufactured hundreds of customized specials that are cost effective and functional for a variety of customers. for use in cancer research, pharmaceutical aseptic drug production and manufacturing, laboratory animal facilities, food processing, clean areas for cgmp manufacturing requirements, and robotic enclosures. About The Process Each project is assigned a NuAire custom products specialist who interfaces with the customer from the initial idea, design, and quote stages through the fabrication, testing, and delivery stages to the installation, service, and after support stages. You ll have just one NuAire contact making sure we meet your expectations. 3
6 NU-201 Horizontal Airflow Workstation The AireGard NU-201 Horizontal Laminar Airflow Table Top Workstation provides a HEPA filtered clean work area that is ideal for operations requiring a particle-free, bacteria-free, clean air environment. The NU-201 features true laminar airflow, a large 99.99% HEPA filter, disposable fiberglass pre-filters, high-capacity motor/ NU-201 NU-201 features include an ergonomically designed radius front work surface, removable front grill for easy cleaning, and a 1 2 radius lip located on back of work surface to protect the HEPA filter from inadvertent spills. blower, adjustable motor speed controller, Minihelic pressure gauge, and the HEPEX Zero Leak Airflow System. Life Science Research The clean work area provides an excellent work space Standard Sizes Catalog Number for small laboratory appliances, microscopes, pipetting, or Nominal Cabinet Width, Feet (mm) Work Zone [Filter] Height, Inches (mm) NU (610) Pharmacy NU (610) 30 (762) For use in compounding NU (914) sterile drug preparations or NU (914) 30 (762) IV admixture preparation. NU (914) 36 (914) NU (914) Animal or Plant NU (914) 30 (762) For procedures requiring NU (914) 36 (914) NU (1524) NU (1524) 30 (762) NU (1524) 36 (914) NU (1829) NU (1829) 30 (762) Standard Features work-in-progress protection from outside potentially harmful contaminants. Electronic Testing, Manufacturing, or Inspections Dirty Room Air Clean Filtered Air Accessories and Options HEPEX Zero-Leak Airflow System Protective Fiber Grill Energy Saver DC ECM Motor Base Support Stand for NU-201 Clear Top/Side Acrylic Panels Glass Disposable Pre-filter Ultraviolet Light Footrest Full Instrument Panel Outlet Storage Trays Minihelic Gauge Service Valves Stainless Steel Work Surface 115 VAC, 60 Hz, Single Phase Ground Fault Interrupter (GFI) Stainless Steel Side Walls 8 ft, 3-wire Grounded Flexible Power Cord IV Bar Textured Powder Coat Urethane Finish Smooth Formica Work Surface Front Maintenance Fluorescent Light 4 similar applications. Adjustable Base Support Stand for NU-201
7 NU-301 Horizontal Airflow Workstation The AireGard NU-301 Horizontal Laminar Airflow Console Workstation provides a HEPA filtered clean work area that is ideal for operations requiring a particle-free, bacteria-free, clean air environment. The NU-301 features true laminar airflow, a large 99.99% HEPA filter, disposable fiberglass pre-filters, high-capacity motor/blower, adjustable motor speed controller, Minihelic pressure gauge, fluorescent lighting, and the HEPEX Zero Leak Airflow System. Life Science Research The clean work area provides an excellent work space for small laboratory appliances, microscopes, pipetting, or similar applications. Pharmacy For use in compounding sterile drug preparations or IV admixture preparation. Animal or Plant For procedures requiring work-in-progress protection from outside potentially harmful contaminants. Electronic Testing, Manufacturing, or Inspections Dirty Room Air Clean Filtered Air Standard Sizes Catalog Number NU-301 Nominal Cabinet Width, Feet (mm) Work Zone [Filter] Height, Inches (mm) NU (914) NU (914) 30 (762) NU (914) 36 (914) NU (1219) NU (1219) 30 (762) NU (1219) 36 (914) NU (1524) NU (1524) 30 (762) NU (1524) 36 (914) NU (1829) NU (1829) 30 (762) NU (1829) 36 (914) Standard Features Accessories and Options HEPEX Zero-Leak Airflow System Clear Top/Side Acrylic Panels Textured Powder Coat Urethane Finish Smooth White Formica Work Surface Front Maintenance Protective Grill Glass Disposable Pre-filter Full Instrument Panel Minihelic Gauge 115 VAC, 60 Hz, single phase 8 ft, 3-wire Grounded Flexible Power Cord Energy Saver DC ECM Motor Ultraviolet Light Outlet Service Valves Ground Fault Interrupter (GFI) IV Bar Footrest Storage Trays Stainless Steel Work Surface Stainless Steel Side Walls Fluorescent Light 5
8 NU-101 Vertical Airflow Clean Workstation The NU-101 Vertical Airflow Clean Workstation provides better than an ISO Class 5 clean air environment. NU-101 Available Airflow Modes Mode E Mode ER Mode O The NU-101 can be used for many applications involving the need to keep work free of contaminants. Available in 5 airflow modes and 12 different sizes, the NU-101 can be configured to meet your needs. Life Science Research The NU-101 has a variety of uses including the accommodation of robotic equipment for lab automation. Pharmacy The NU-101 can be used for the sterile preparation of IV admixtures, CSP s, antibiotics, or automated compounding equipment. Class 5 Air Quality For procedures requiring work-in-progress protection from outside potentially harmful contaminants. Exhaust Exhaust With Recirculation Open Base Mode WO Mode WT Table Top Wash Out Perforated Table Top Wash Through Standard Features 12 Sizes Available HEPEX Zero Leak Airflow System 99.99% HEPA Filtration System Air Intake Grill and Pre-Filter Fluorescent Lighting Optional Features Duplex Outlets Exhaust Chambers Exhaust Transitions Stainless Steel Interior IV Bar Ultraviolet Lights 8 ft Power Cord Centrally Located Control Center Powder Coat Urethane Finish Interior Cold-Rolled Finished Steel Attenumount Vibration Control System Service valves for Air, Gas, Vacuum Side Panels Tables and Table Tops Stainless Steel Work Surfaces Increased Work Zone Height Custom Design 6
9 NU-126 Vertical Airflow Clean Workstation The AireGard NU-126 Vertical Laminar Airflow Workstations are designed to provide the ideal particle-free, bacteria-free clean-air environment needed for laboratory work, testing, manufacturing, inspection, or pharmaceutical procedures. The exclusive design innovations built into the NU-126 will provide exceptional performance in the most demanding environments. Life Science Research Use with a thermal cycler, small centrifuge, or other types of small equipment where clean air is a requirement. Standard Sizes NU-126 Pharmacy For use in the sterile preparations of an IV Room Air Admixture, Antibiotics, or other drugs. HEPA Filtered Clean Air Animal or Plant For work involving procedures requiring work-in-progress protection from outside potentially harmful contaminants. Testing Manufacturing or Inspections Catalog Number NU /E NU /E NU /E Overall Dimensions, Inches (mm) Width Depth Height Work Area Dimensions: Inches (mm) Width Depth Height 30 (762) 22 (559) 44 (1118) 29 (737) 21 3 /4 (552) 42 (1067) 22 (559) 44 (1118) 41 (1041) 21 3 /4 (552) 71 5 /8 (1818) 26 7 /8 (684) 50 5 /8 (1285) 70 5 /8 (1794) 26 5 /8 (675) 28 3 /8 (721) Note: Specifications are subject to change. Dimensions have changed with series 21. Please contact NuAire before purchase. Standard Features Optional Features Vertical Airflow-Product Protection Fluorescent Lighting Fiberglass Pre-filters 90 FPM (.46 m/s) Down Flow Air Velocity Energy Saver EC Impeller Motor Service Vales for Gas, Air, Vacuum 36 (914 mm) Base Support Stand Front Closure Panel Clear Acrylic Side Walls White Formica Work Surface Stainless Steel Work Surface Clear Polycarbonate Viewing Window Hinged View Screen w/autolift Two Service Ports 99.99% HEPA 8.5 Access Opening Minihelic Pressure Gauge Indicates Filter Load IV Bar with Six Hooks Ultraviolet (Germicidal) Lamp 30 (762 mm) Base Support Stand HEPA Filtered Airflow FlowGard Pressure Monitor (NU /E) 7
10 NU-112/114 Clean Air Scrubbers The NU-112 and NU-114 Clean Air Scrubbers are portable self-contained units capable of filtering particulates where ISO Class 7 or Class 8 Air Quality is a requirement. NU-112 NU-114 The cabinet utilizes rough disposable pre-filters to help prolong the life cycle of the main 99.99% HEPA filter. Each scrubber can be used in a variety of different locations, depending upon the need for clean air. Positive/Negative Room Pressure Application This versatile unit can be used to recirculate air in a defined area, or be placed between two distinct adjacent areas to act as a positive or negative pressure and the outlet side will have higher (positive) air pressure. Room Recirculation Application Construction The AireGard 114 can be built in to a temporary wall or hallway during construction or remodeling projects. Air can be continuously drawn away from the contaminated area and exhausted as clean HEPA-filtered air into the clean area. The Aire- Gard 114 can also be used within a construction area to recirculate and purify air when ceiling tiles, walls, or plumbing are disrupted or if fumes and odors are evident from cleaning, painting, etc. Clinical/Medical More Air Changes Means Air is Filtered More Frequently Resulting in Superior Air Quality General Air Quality Room Size in Feet (H x W x D) = X cu.ft. 720 CFM (Air Volume) = number of room air Room Size in cu.ft. changes per minute Example Room Size = 8 ft. x 10 ft. x 12 ft. = 960 cu.ft. 720 CFM =.75 room air changes per minute 960 cu.ft..75 x 60 minutes = 45 room air changes / hour The AireGard 112 can be used for recirculating air in common areas where highly filtered air is desired and any location where the potential infection status of occupants is a concern. HEPA filtration is effective in controlling infectious bacteria and viruses ranging from common cold germs to more dangerous organisms such as SARS and TB. Biological Terrorism The unit can provide a significant measure of safety in the capture and containment of microbes having a history of use or those likely to be used in an act of terrorism 8
11 NU-105 Air Cleaning Ceiling Modules NuAire has developed this unique type of air cleaning ceiling module for clean room use. This product was developed to provide an inexpensive solution for today s modern laboratory professional. Air Cleaning Module with Remote Blower The NU-105 is an inexpensive way of creating a clean room providing both HEPA filtered air and fluorescent lighting in a single unit. The modules may be placed as needed to provide light and clean air over critical areas. NU-105 is desired to have the greatest amount of ventilation fresh air inflow through the module, simply close the recycling grills and fully open the inflow damper. Inflow Grills - Both Sides Ceiling Support Rod Control Panel Clean Air 100 FPM Energy Saver Shower The NU-105 is a recycling air shower designed to provide particulate-free air to a room. It is the least expensive way to create a sterile clean room having Class 100 air cleanliness. The air shower is adaptable to large or small rooms. Single-Pass Air Shower A completely self-contained air cleaning module that accepts rough-filtered plant ventilation air and forces it through a HEPA filter. It can be used to create a small sterility room, or with multiple ceiling installations to create a large clean room to handle heat loads, odor dilution, etc. The NU-105 is designed to permit the normal plant ventilation air to flow freely into the room through the adjustable grills when the ceiling module blower is not running. This automatic by-pass feature prevents the HEPA filter from blocking airflow into the room when the supply blower is not operating. Normally, the recycling grills are fully open to permit the highest cycling rate in terms of air changes per hour. However, if it Standard Sizes Catalog Number Overall Dimensions, Inches (mm) Width Depth Height NU (584) 47 (1194) 22 (559) NU (889) 51 1 /2 (1308) 25 (635) NU (1041) 51 1 /2 (1308) 28 (711) NU (1041) 63 1 /2 (1613) 28 (711) NU (1041) 75 1 /2 (1918) 30 (762) Standard Features Optional Features HEPA Filter, 99.99% Efficient on 0.3 Microns 16 GA Welded Construction Bottom Filter Service Flow Control Valve Electrical Junction Box Ceiling Hanger Corner Inserts (1/2 13 Thread) Fluorescent Lighting Duplex outlet 9
12 NU-125 Class II Biological Safety Cabinet Mini-Room Class II Protection for Your Robotics. NU-125 The NU-125 provides Class II protection for personnel, product, and the environment. The room can be used for applications involving high-throughput robotic systems, large high-speed cell sorters, ultra-centrifuges, and laboratory equipment requiring Class II protection from potentially harmful aerosols and airborne particles. A perfect match for the BD FACS Airflow Cytometer Laboratory equipment or processes requiring sterility Class II Biological Safety Cabinet protection for robotics Airflow HEPA Filtered Air Exhaust Contaminated Air Room Air 60 FPM Downflow Standard Features Energy Saver DC ECM Motor True Laminar Airflow Stainless Steel Interior ISO Class 5 Air Quality HEPEX Zero Leak Airflow System Side Access Ports 8 Access Work Opening Central Control Panel Hinged View Screen Minihelic Pressure Gauge Front Filter Removal Fluorescent Lighting GFI Duplex Outlets Optional Features Exhaust Transitions Additional Duplex Outlets Custom Application Requirements Stainless Steel Portable Table Table is available with: 5 Diameters SST Casters Adjustable w/autolift 105 FPM Inflow Velocity 10
13 NU-813 Class I Safety Cabinet Portable Safety Station For Personnel Protection Containment. The NU-813 provides personnel protection for handling aerosols and particulate matter of low risk assessment. This configuration employs a 99.99% efficient HEPA filter. Ductless Fume Hood The NU-813 provides personnel protection from solvents such as those employed in cytology. This configuration uses either a Purafil filter or a charcoal filter. The Class I safety cabinet allows room air to enter the hood, flowing past the operator into the work access opening. This provides an air barrier which minimizes contaminants generated within the hood work zone from migrating into the room. Life Science and/or Hospital Ideal for the safe handling of NU-813 powders or liquids. Can use a micro-computer based balance Standard Sizes within the work area. Catalog Number NU / 300E NU / 400E NU / 600E Pharmacy For compounding powders in a safe environment. Room Air Animal HEPA Filtered Exhaust Air For necropsy or other processes that require personnel protection. Overall Dimensions, Inches (mm) Width Depth Height Interior Dimensions, Inches (mm) Width Depth Height 36 (914) 29 (737) 51 1 /2 (1308) 34 3 /8 (873) 28 (711) 48 (1219) 29 (737) 51 1 /2 (1308) 46 3 /8 (1178) 28 (711) 72 (1829) 29 (737) 51 1 /2 (1308) 70 3 /8 (1788) 28 (711) Standard Features Self Exhausting Fluorescent Lighting Clear Polycarbonate Side Panels WhitePolycarbonate Back Panel Coved Epoxy Black Base Hinged Viewing Window 99.99% Exhaust HEPA Filter Two Service Ports FlowGard Pressure Monitor Optional Features Energy Saver EC Impeller Motor Base Support Stands Purafil Filter (in Lieu of HEPA) Charcoal Filter (in Lieu of HEPA) 11
14 NU-819 Class I Vented Workstation Portable FumeHood Safety. NU-819 The NU-819 is a Class I vented enclosure designed to contain and remove contaminants from the work surface with the aid of an external exhaust system. The NU-819 is a partially enclosed workspace with clear acrylic side walls and front view screen. An air barrier inflow velocity set between 75 and 100 FPM provides optimal personnel protection. The NU-819 work surface is constructed using black epoxy and incorporates an ergonomically designed work access air foil to maximize comfort and improve air barrier protection. Standard Sizes Room Air Catalog Number NU NU Overall Dimensions, Inches (mm) Width Depth Height Work Area Dimensions, Inches (mm) Width Depth Height 36 (914) 31 3 /4 (806) 22 7 /8 (581) 34 3 /4 (883) 21 1 /4 (540) 18 1 /8 (460) 48 (1219) 31 3 /4 (806) 22 7 /8 (581) 46 3 /4 (1187) 21 1 /4 (540) 18 1 /8 (460) The NU-819 Vented Workstation provides safe, reliable performance for applications involving pipetting, staining, transfers, animal necropsy, slide preps; small equipment uses such as blenders, robotics, balances, water baths, and centrifuges; or other applications where personnel safety is mandatory. Standard Features Clear Acrylic Side Walls Clear Acrylic Hinged Viewing Window White Acrylic Back Panel Black Epoxy Work Surface Optional Features Low Flow Alarm Base Support Stand Exhaust HEPA Filter Blower Module [A] Flexible Exhaust Duct [B] [B] [A] 12
15 Custom Equipment, Lab Supplies and More from NuAire Experience Customized Equipment Any Product, Any Time, Any Where. A dedicated engineering department provides you exactly what you need NuAire puts their customers first. In a demanding world where you cannot always get what you want, NuAire is there making sure you get what you need down to every detailed specification. Experts in laminar flow, NuAire engineers customize products to meet rigid standards which ensure personnel, product, and environmental protection. Lead-Lined Biological Safety Cabinet Products that can be customized to your specifications: biological safety cabinets, laminar flow hoods, pharmacy isolators, small animal bedding disposals, small animal handling equipment, laminar flow walk-in enclosures, Class III glove boxes, polypropylene products, and much more! Experience NuAire custom engineered equipment and get what you really need. Class II to Class III Room Pass-Through Laboratory Equipment and Supplies NuAire offers a select variety of laboratory equipment supplies, aids, and accessories for use by the laboratory professional to improve their work environment. Products include: an ergonomically-designed elbow/forearm rest, stainless steel turntable, footrests, portable ultraviolet light for use within a biological safety cabinets, ultralow temperature freezer racks, CO 2 incubator shelves and tank switches, electrical surge suppressor, small acrylic fume hoods, and stainless steel butterfly valves. Scientific Visions products can make a difference. NuAire Products Available Worldwide To Locate a NuAire Distributor, please visit and select the Sales Team menu item. Information can be found there for both United States and international distributors. CO 2 Incubators ULT Freezers Biological Safety Cabinets 13
16 Process DB Rev. 3 10/11 For more information please visit or call
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
Laminar Flow Cabinets and Workstations
VERTICAL AND HORIZONTAL HEPA FILTERED SYSTEMS FOR PROCESS OR OPERATOR PROTECTION Laminar Flow Cabinets and Workstations For procedures requiring protection from particulate contamination and for aseptic
Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health
Background Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health This document provides guidelines for the design and installation of Class
General Purpose Laminar Flow Cabinets, Horizontal and Vertical
24 36 48 60 72 96 The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. VLF-48 Provides reliable protection for samples and work processes for a multitude of applications. p:2 Product
Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.
Product Sampler #1 Laminar Flow Hoods / Laminar Flow Cabinets: 1- Benchtop Vertical Laminar Flow Hoods- Air Recirculation Available s: Clean Bench Class 100 Bench-top Vertical Laminar Flow Hoods with Air-recirculation
Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity
Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity Best Products. Best Performance. Best Protection. NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A ph: 763.553.1270 fx:
FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.
Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. Vertical Laminar Flow Cabinets BEYOND MINIMUM SAFETY REQUIREMENT Cabinets are ISO Class 3 vertical laminar flow cabinets which
Chemical Fume Hoods. Environmental Health and Safety 974-5084
Chemical Fume Hoods Environmental Health and Safety 974-5084 Regulatory References Prudent Practices in the Laboratory 2011 (National Research Council of The National Academies): Laboratory chemical hoods
CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications
1 CO2 Incubator Model CCL-170_-_ CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications Welcome to Esco Esco s Vision is to provide enabling technologies for scientific
Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories
Esco Labculture Laminar Flow Clean Bench Model LHC-4A_ AS 1386.5, EN12469 (Microbiological Testing Method) Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories
Procedures for the Effective Use of Biological Safety Cabinets
Procedures for the Effective Use of Biological Safety Cabinets APPROVAL DATE BY BIOHAZARDS SUBCOMMITTEE: August 10, 2012 SUPERSEDES: March 1, 2012 This corporate guideline/procedure is intended as a minimum
In Vitro Fertilization Workstation. Esco IVF Workstation, Model IVF-4A_. Shown with optional support stand.
In Vitro Fertilization Workstation Esco IVF Workstation, Model IVF-4A_. Shown with optional support stand. Introduction The Labculture IVF workstation is specially designed for use in fertility laboratories
Fume Hood Questions and Answers
Fume Hood Questions and Answers 1. When should I use a fume hood? Use a chemical fume hood anytime your work involves: Chemicals with a National Fire Protection Association (NFPA) Health rating of 3 or
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG-007-2010 March 24, 2010 1. Background Class II Type B Biosafety Cabinets (BSCs) are unique laboratory
LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL
LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL ENVIRCO Technical Support: 800-884-0002 Table of Contents WARNING... 3 INTRODUCTION... 3 FEATURES... 4 APPLICATIONS... 4 ASSEMBLY...
BIOLOGICAL SAFETY CABINET PROGRAM
BIOLOGICAL SAFETY CABINET PROGRAM TABLE OF CONTENTS: 1. INTRODUCTION 2. PURPOSE AND SCOPE 3. SELECTION AND INSTALLATION 4. USE OF BIOLOGICAL SAFETY CABINETS 5. CERTIFICATION OF BIOLOGICAL SAFETY CABINETS
Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection
Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection A wide range of products to meet the needs of transferring animals, operators,
LAMINAR FLOW CABINETS
LAMINAR FLOW CABINETS Vertical Laminar Flow Cabinets VLF 550 VLF650 VLF1000 VLF1200 VLF 1500 VLF1800 Monmouth Scientific's brand new range of Vertical laminar Flow (VLF) cabinets is available in six different
Spetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR. www.sentryair.com 1.800.799.
SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR 1.800.799.4609 www.sentryair.com Pharmaceutical Compounding Safety Solutions Sentry Air Systems
Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories
Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories Esco Airstream Laminar Flow Clean Bench Model AHC-4D_ Esco Experience Esco is the world leader in premium
Risk Assessment: Biosafety Cabinet
Risk Assessment: Biosafety Cabinet Biosafety cabinets (BSCs) serve as primary containment devices for operations involving potential splashes, spills or aerosolization of hazardous biological materials.
LAMINAR FLOW FOR ALL YOUR NEEDS
LAMINAR FLOW FOR ALL YOUR NEEDS 2 LAMINAR FLOW FOR ALL YOUR NEEDS EXPLORE TECNIPLAST COMPLETE RANGE OF LAMINAR FLOW SOLUTIONS: OUR CUTTING-EDGE TECNOLOGY IS AT YOUR SERVICE, TO ASSURE TOP ENVIRONMENTAL,
Downflo workstation DuSt ColleCtorS
Downflo WorkStation Dust Collectors Outperforms All Other Collectors Downflo WorkStations (DWS) fit anywhere on the plant floor and apply NO restrictions to worker movements or visibility. The full line
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
A. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
Laboratory Ventilation Safety. J. Scott Ward
Laboratory Ventilation Safety J. Scott Ward In 1925, Laboratory Construction Company was born. The first product was a Kjeldahl Nitrogen Determination Apparatus. We may have shortened our name, but we
Today, healthcare facilities must be prepared to face
Alternate Methods for USING GERMICIDAL UV-C Disinfection Lamps TO SUPPLEMENT HEPA Filtration By Dave Shagott Today, healthcare facilities must be prepared to face potential large-scale threats from chemical,
SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY
SPACE TYPE: LABORATORY (WET) FOR CHEMISTRY AND BIOLOGY Construction Criteria The unit costs for (Wet) space types are based on the construction quality and design features in the following table. This
Cleanroom Solutions Ltd T: 01273 760 060 F: 01273 760 061 E: [email protected] W: www.cleanroom-solutions.co.uk
Cleanroom Solutions Ltd T: 01273 760 060 F: 01273 760 061 E: [email protected] W: Introduction Cleanroom Solutions Ltd has a wealth of experience together with a solid track record in the
WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems
WIBOjekt and WIBObarrier Air Curtain Systems. The perfect protection for person, product and environment. Filling Weighing Sampling Research Safe handling with high potent products / API WIBObarrier OCS
Environmental Monitoring
Chapter 10 Environmental Monitoring By the end of this chapter, you will be able to: l List the types of environmental testing l Name three types of checks that are carried out to ensure the isolator is
MODEL NU-9728-86 C ULTRALOW TEMPERATURE FREEZERS
POLAR EDITION -86 C ULTRALOW FREEZER MODEL NU-9728-86 C ULTRALOW TEMPERATURE FREEZERS NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 WWW.NUAIRE.COM POLAR EDITION -86 C ULTRALOW
French Door Refrigerator E23BC78IPS professional series
French Door Refrigerator E23BC78IPS professional series 23 CU. FT. COUNTER-DEPTH FRENCH DOOR REFRIGERATOR Custom Temp Drawer Enjoy the ultimate in versatility with 9 preset selections including White/Sparkling
Range Equipment HVAC Design & Supply Modular Ranges
Range Equipment HVAC Design & Supply Modular Ranges SRI Shooting Range Industries LLC, SRI is a premier design and manufacturing company of quality and innovative live fire Modular Containerized Small
OPERATOR S MANUAL. EdgeGARD Horizontal Laminar Flow Clean Bench
THE BAKER COMPANY OPERATOR S MANUAL EdgeGARD Horizontal Laminar Flow Clean Bench Console Models: EG3252, EG4252, EG4320, EG5252, EG6252, EG6320, EG8252, and EG8320 Space-Saver Model: EGB-IV22 ~ The Baker
DRYER VENTING SPECIFICATIONS DRYER SAFETY
DRYER VENTING SPECIFICATIONS Table of Contents DRYER SAFETY...1 INSTALLATION REQUIREMENTS...4 Venting Requirements...5 DRYER INSPECTION AND CLEANING...7 Frequency of Exhaust System Cleaning...7 Inspecting
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION
Cabinets 101: Configuring A Network Or Server Cabinet
Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What
UniMax Large Floor Mount (Walk-In) Fume Hoods
UniMax Large Floor Mount (Walk-In) Fume Hoods UniMax Fume Hoods HazMax Fume Hoods Access Door/Sash Options Plumbing/Electrical Services Exhaust/Ventilation Services Filter/Scrubber Services Laboratory
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
Spetec. Clean room. technology. Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification
Spetec Clean room technology Laminar flow box Clean room workbench CleanBoy Clean room cell Service, certification 1 Product overview PBS, FMS, and FBS series device families feature a modular design,
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions
HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom Frequently Asked Questions What is a negative air machine and why do I need one?
Laboratory Design & Construction Guidelines
Laboratory Design & Construction Guidelines Department of Environmental Health & Safety EHS-M-35 Page 1 Issue Date: 03/01/10 General Health and Safety The USC Environmental Health and Safety Department
Series 18 Pass Thru Air Lock Cleanroom Entry System
OPERATION & MAINTENANCE INSTRUCTIONS FOR Series 18 Pass Thru Air Lock Cleanroom Entry System SOLUTIONS BUILT TO YOUR SPECIFICATIONS 8605 Wyoming Ave. N. Minneapolis MN 55445 fax: 763.425.2004 e-mail: [email protected]
PART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE
(An Autonomous Institution of the Department of Biotechnology, Govt. of India) N.C.C.S. Complex, Ganeshkhind, Pune University Campus, Pune 411007. PART-II (COMMERCIAL / PRICE BID) DESIGN, AND INSTALLATION
techorganizer and techbench built for durability, designed for flexibility
techorganizer and techbench built for durability, designed for flexibility Wright Line sets a higher standard for engineering, manufacturing, test and assembly environments with TechBench and. TechBench,
PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)
PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3) Yes No 1. Is access to the laboratory limited or restricted at the discretion of the laboratory director when experiments are in progress? Yes No
Protection, safety, reliability. And more. LAMINAR FLOW CABINETS AND SYSTEMS
Protection, safety, reliability. And more. LAMINAR FLOW AND SYSTEMS LAMINAR FLOW AND SYSTEMS FASTER S.R.L., BASED IN ITALY SINCE 1984, HAVE BECOME IN 30 YEARS ONE OF THE LEADING EUROPEAN MANUFACTURERS
Secure your IT equipment with confidence... secure with NetClosure
Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade
Robert McCabe Director, Health Care Solutions HTS Chicago Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade Biography Robert McCabe has been involved in commercial
-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com
-86 C ULTRALOW TEMPERATURE FREEZERS NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com NuAire Glacier -86 C Ultra-low Temperature Freezer NuAire Glacier -86 C Ultra-low
KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS
St. Louis County Department of Public Works Division of Code Enforcement KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS This guideline is intended to provide the homeowner/contractor with the
MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS
MAC 10 Original & IQ FAMILY OF FAN FILTER UNITS used in: microelectronics medical device semiconductor disk drive laboratory pharmaceutical markets hospitals clean rooms Table of Contents MAC 10 Original
Spray Booth Guideline
Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that
Shakers, Incubators, Clean Benches, Water Baths, Drying Ovens
Shakers, Incubators, Clean Benches, Water Baths, Drying Ovens Ask for catalogues and brochures Learn distribution terms and conditions Download brochures and leaflets Register for monthly newsletters Check
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Hazardous Drug. Cleanroom. Standards
Hazardous Drug Cleanroom Standards Module 3 Table of Contents Section A... 1 A.1 International Standards Organization (ISO) Classifications... 1 A.2 Hazardous Drug Cleanroom and Anteroom... 1 A.2.1 Location
Environmental Monitoring of Clean Rooms
Environmental Monitoring of Raul Duarte President DDK Scientific, Corp. Copyright DDK Scientific, Corp. 2008, 2009, DDK Scientific, Corp. Proprietary A manufacturing facility for pharmaceutical products
Series 412. Vertical Laminar Flow Clean Bench. Series 412 Vertical Laminar Flow Clean Bench
Series 412 Vertical Laminar Flow Clean Bench S O L U T I O N S The Series 412 vertical laminar flow clean benches are specifically designed to create a freestanding ultra-clean mini-environment. These
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace
Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace Our thanks to OK International for allowing us to reprint the following. Why do we need fume extraction? Today s Electronics workplace
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS
TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to
Ductless Spray Booth Series
Sentry Air Systems, Inc. Ductless Spray Booth Series A Respiratory Safety Engineering Control: Ductless Benchtop Hooded Enclosures for the extraction and purification of aerosol spray paint fumes & particulate.
Sample Pharmacy CLEANING AND SANITIZING PROCEDURE P-304.1
P-304.1 1.0 Definition and Purpose: To standardize and define the process by which the controlled Cleanroom environments (ISO Class 5, 7, and 8) and the general pharmacy prep area is cleaned, disinfected,
User Manual LFGI-3USP LFGI-4USP LFGI-6USP. GERMFREE 11 Aviator Way Ormond Beach, FL 32174 800-888-5357 Phone 386-677-1114 Fax
User Manual LFGI-3USP LFGI-4USP LFGI-6USP GERMFREE 11 Aviator Way Ormond Beach, FL 32174 800-888-5357 Phone 386-677-1114 Fax [email protected] www.germfree.com Table of Contents PREFACE 5 SAFETY, OPERATION
Basics of HVAC Cleaning
Basics of HVAC Cleaning Seminar Outline Residential 1. Types of systems used and why 2. Types of air distribution systems 3. System components 4. Determining the need for cleaning (ACR2002) 5. Project
Installation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
SPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
Biosafety Level 2 (BSL-2) Safety Guidelines
BLS-4 Biosafety Level 2 (BSL-2) Safety Guidelines BSL-3 BSL-2 BSL-1 BSL-2 builds upon BSL-1. If you work in a lab that is designated a BSL-2, the microbes used pose moderate hazards to laboratory staff
Laboratory Division. Product Range Cold Storage Clean Air Lyo
Laboratory Division Product Range Cold Storage Clean Air Lyo Laboratory Division Product Range Laminar Flow & Biosafety cabinets Operator, product & environment protection Microbiological safety cabinets
SERVER ROOM CABINET INSTALLATION CONCEPTS
SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the
FIRE DAMPER APPLICATION GUIDE
FIRE AND CEILING RADIATION DAMPERS FIRE DAMPER APPLICATION GUIDE Use this application guide to help determine what type of fire damper best suits the application. Below are listed the ten Metal-Fab fire
Commercial Portable Air Conditioners
Commercial Portable Air Conditioners Air Rover commercial portable air conditioners provide the environmental stability and comfort required by today s sensitive equipment, allowing your business to avoid
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
LyoBeta. R+D Freeze-Dryers
LyoBeta R+D Freeze-Dryers LyoBeta series A Responsible Choice New demands in R+D centers are related to scale-up feasibility and quality of procedures and research methods. FDA investigators consider that
Donut Robot Mark I Mark VI
The worldwide leader in donut production equipment +1.206.322.5474 [email protected] www.belshaw.com AUTOMATIC FRYERS Donut Robot Mark I Mark VI Donut Robot Series Automatic Fryers deposit, fry, turn, and
Modular Glovebox Systems Gas Purifier Units Antechambers Accessories
Modular Glovebox Systems Gas Purifier Units Antechambers Accessories INERTGAS TECHNOLOGY Modular glovebox with screwed in flanged side panels Easy to extend or modify while keeping a flat work place Define
Laminar Flow Hoods and Booths
Laminar Flow Hoods and Booths ... we go further... to absolutely clean air! Klimaoprema Cleanroom Technology is a leading Croatian manufacturer of equipment for cleanrooms. We offer complete engineering
ASALAIR BIOHAZARD CABINET MODEL ATLANTIC CYTOCABINET 1200 CLASS II TYPE A2 COD. 29940086 MICROBIOLOGICAL SAFETY CABINET CLASS II TYPE A2
ASAL S.R.L. - APPARECCHI SCIENTIFICI ATTREZZATURE LABORATORI Quality System comply with requirements of UNI EN ISO 9001:2008. Certificate TÜV Italia n 50 100 3290 Rev. 02 ASALAIR BIOHAZARD CABINET MODEL
Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing
Nu/Clean 818 XLR-FB Touch Screen Inline Aqueous Cleaner Technical Specifications & Pricing Since 1952, Technical Devices has been supplying the electronics industry with the highest quality production
A Guide to Laboratory Fume Hoods
A Guide to Laboratory Fume Hoods INTRODUCTION Laboratory fume hoods are a type of ventilation system with the primary function is to exhaust chemical fumes, vapors, gasses, dust, mist and aerosol. Fume
Under sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
Particle Monitoring Requirements in Pharmaceutical Cleanrooms
Particle Monitoring Requirements in Pharmaceutical Cleanrooms All drugs must be manufactured in accordance with the current Good Manufacturing Practice (cgmp) regulations. Pharmaceutical manufacturers
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project
Questions & Answers (Q & A) Regarding Asbestos Treatment with the Fire Suppression and Renovation Project The Watergate Community is currently in the process with the fire suppression and interior renovations
Spetec Laminar Flow Systems. Operating Instructions
Spetec Laminar Flow Systems Operating Instructions 1 Spetec Laminar Flow Systems Operating Instructions Thank you for your trust in the Spetec clean room systems! Your chosen system is ideally suited for
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Safety Inspection Checklist
Inspector(s): Building: Room Number (s): Department/Unit: Date Inspected: Supervisor: To customize your local inspection checklist, delete or add as required. Inspection Headings: 1. Administrative 8.
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting