1 Application Description... 2 2 System Topology... 2 3 Hardware and Software Requirements... 3



Similar documents
1 Application Description Objective Goals... 3

EtherNet/IP Scanner Configuration for the Moxa MGate 5105-MB-EIP

Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description Objective Goals...

Ethernet Gateway for SIMATIC MPI/ PROFIBUS Driver

Service & Support. How can you establish a connection between an S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

NPort. Copyright 2008 Moxa Inc. Released on July 15, 2008

32 Transferring Projects and Data

BASLER ACE QUICK INSTALLATION GUIDE

TECHNICAL NOTE TNOI34

Service & Support. How can you establish a connection between a S PLC and SIMATIC NET OPC? S PLC, SIMATIC NET OPC.

Easy! Smooth! GP/ST-3500 Series->GP4000 Series Replacement Guidebook

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

Interfacing Basler GigE Cameras With Cognex VisionPro 7.2

Using KEPServerEX OPC Server (Kepware)with the iologik E2210

Working with SQL Server Integration Services

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

S-SupremaConfigurationGuide-DOC 7/23/2014. Suprema Biometrics Configuration Guide ACS OnSite Aparato

Adding a Modbus TCP Device to the Network. Setting Up Your Network

The goal is to program the PLC and HMI to count with the following behaviors:

UDS2100 Quick Start Guide

QuickPanel Control DeviceNet Master Communications Card (IC754DVNM01) Quick Start Guide. Thursday September 20, 2007

Schneider OS-Loader usage via Ethernet or USB.

Setting up VPN Access for Remote Diagnostics Support

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

DUKANE Intelligent Assembly Solutions

Network Adapter Configuration Guide for Macintosh OS X

Packet Tracer 3 Lab VLSM 2 Solution

Configuring the WT-4 for Upload to a Computer (Ad-hoc Mode)

PROFINET IRT: Getting Started with The Siemens CPU 315 PLC

64-Bit Compatibility with Micromeritics Applications

APNT#1168 Modbus - Establishing Communications Hints

Networking Basics for Automation Engineers

C-more Remote Access, Data Log, FTP File Transfer, and Tutorial

Mitsubishi Electric Q Series PLC Ladder Monitor. Operation Manual

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODUL E04

C-more Remote Access with Apple ipad or iphone Tutorial

Building a groov HMI for Allen-Bradley Logix Systems. About groov. Building a groov HMI for Allen-Bradley Logix. A-B Systems and groov

How To Use Mview On A Powerline 2.2 (Powerline) On A Pc Or Macbook 2 (Powerplst) On An Iphone Or Ipa 2 (Aldo) On Your Iphon 2 (

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

This guide describes the details that are necessary for making a HMI (PC RT or panel) for an S5 PLC.

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

How to use Citect (SCADA) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)

Crown Field Support Engineering

Profinet to EDV111 Series LED Signs Siemens Function Block Software Manual

GBIC-Optical SX 850nm (Multi Mode) GBIC-Optical LX 1310nm (Single Mode) GBIC-Electrical TX 1000 BaseT (RG-45)

WinCC. Communication Manual. Manual 2. This manual is part of the documentation package with the order number: 6AV6392-1CA05-0AB0 C79000-G8276-C156-01

WindO/I-NV2 Utility Pass-Through Tool

Self Help Guide IMPORTANT! F5D Setting Up An Ad Hoc Connection. Please read the following carefully;

MODBUS TCP Master Driver

Deployment Guide: Transparent Mode

FAQ Communication over IE

CMP-102U. Quick Installation Guide

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

CP500 CONTROL PANELS. CP500 Soft: First Step with AC500 series on Ethernet. Step8. ABB Entrelec 1SBC159100M0202_Ch8 En

PLC training panel (Twido version)

Configuring Windows 7 64 bit for AutoVISION

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

AEI RAIL NETWORK SERVER User Manual

GE Security. FHSD Monitor / Web Server user manual

Modbus and ION Technology

Easy! Smooth! GP-3300 Series->GP4000 Series Replacement Guidebook

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

1. Installing The Monitoring Software

User Guide for Windows 10

Alarm Message C B A. Alarm Message's scroll direction. Scroll the currently triggered Alarms on all screens. C B A. Display alarms.

1 How configure S7 PLC in the configuration tool

BECKHOFF. Application Notes. BC9000: Getting Started Guide. For additional documentation, please visit.

S7 for Windows S7-300/400

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

Cisco S380 and Cisco S680 Web Security Appliance

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

USER GUIDE. Aleratec DVD/CD RoboRacer LS. Part No

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

DTAP3000 DTSX3000 Control Visualization Software LAS2.0 Data Conversion Guide

KV-10_80RW/TW CPU Direct Driver

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

Procedure: You can find the problem sheet on Drive D: of the lab PCs. Part 1: Router & Switch

What is VAIO Power Management?

Beckhoff TwinCAT. Configuring the TwinCAT I/O System

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

NPort s Ethernet Modem Mode

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

CCNA Discovery Networking for Homes and Small Businesses Student Packet Tracer Lab Manual

OSM 2007 MONITORING SOFTWARE

STEP 7 MICRO/WIN TUTORIAL. Step-1: How to open Step 7 Micro/WIN

Modbus and ION Technology

LPT1 Printer Connector. External Power Supply Connector Power Indicator

TECHNICAL NOTE TNOI32

CLEARONE DOCUMENT (REVISION 1.0) October, with Converge Pro Units

Motion Control Products Application note Exporting AC500 tags for use with Panel Builder

Installation Guide for Windows May 2016

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

EasyMP Multi PC Projection Operation Guide

HTML Code Generator V 1.0 For Simatic IT Modules CP IT, IT, IT

Transcription:

Contents Moxa Technical Support Team support@moxa.com 1 Application Description... 2 2 System Topology... 2 3 Hardware and Software Requirements... 3 3.1 Hardware Requirement... 3 3.2 Software Equipment... 3 4 Configuration... 3 4.1 Hardware Installation... 3 4.2 Configuring GP-Pro EX... 5 5 On-line Test... 17 Copyright 2014 Moxa Inc. Released on December 19, 2014 About Moxa Moxa is a leading manufacturer of industrial networking, computing, and automation solutions. With over 25 years of industry experience, Moxa has connected more than 30 million devices worldwide and has a distribution and service network that reaches customers in more than 70 countries. Moxa delivers lasting business value by empowering industry with reliable networks and sincere service for automation systems. Information about Moxa s solutions is available at www.moxa.com. You may also contact Moxa by email at info@moxa.com. How to Contact Moxa Tel: +886-2-8919-1230 Fax: +886-2-8919-1231

1 Application Description Objective This document describes how to use Pro-face GP-4501TW to control and monitor Siemens PLC. Goals This document covers the following topics: How to use Pro-face GP-4501TW. How to use the Pro-face screen editor tool, GP-Pro Ex. How to use Pro-face HMI to control and monitor Siemens PLC. 2 System Topology The following figure shows the system architecture in which the Modbus end devices, PowerFlex 4M and IAQPoint2, are connected to the serial port on MGate 4101-MB-PBS through RS-485-2W wiring. MGate 4101-MB-PBS is connected to the PROFIBUS port on Siemens PLC via a PROFIBUS cable. PC (running SIMATIC Step 7) is connected to an Ethernet switch port on Siemens PLC via an Ethernet cable. A fan is connected to PowerFlex 4M that outputs electric current to power the fan. Pro-face GP-4501TW controls and monitors Siemens PLC via Ethernet connection. Copyright 2014 Moxa Inc. Page 2 of 18

3 Hardware and Software Requirements 3.1 Hardware Requirement A. Pro-face GP-4501TW Pro-face GP-4501TW is a 10.4-inch TFT color, touch screen with operator interface. B. For information on other hardware requirements, refer to the Configuring Siemens S7-300 PLC with Moxa MGate 4101-MB-PBS. 3.2 Software Equipment A. GP-Pro EX: This is the screen editor utility published by Pro-face. Rev.: V3.5 B. For information on other software requirements, refer to the Configuring Siemens S7-300 PLC with Moxa MGate 4101-MB-PBS. 4 Configuration 4.1 Hardware Installation 1. Serial Wiring For information on installing PowerFlex 4M and IAQPoint2, refer to the Configuring Siemens S7-300 PLC with Moxa MGate 4101-MB-PBS. 2. Ethernet Connection Connect CPU 315 to the PC running SIMATIC Step7 through an Ethernet connection to one of the two Ethernet connectors, either directly or through a common Ethernet switch. Connect the PROFIBUS cable from the PROFIBUS port on CPU 315 to the PROFIBUS port on MGate 4101-MB-PBS. Connect the Ethernet port on the Pro-face GP-4501TW to an Ethernet port on CPU 315. Copyright 2014 Moxa Inc. Page 3 of 18

3. Pro-face GP-4501TW IP Setup a. Touch either the top right hand corner then the bottom left hand corner OR the top left hand corner and then the bottom right hand corner within 0.5 seconds. Note: Do not touch both corners at the same time. b. A menu appears on the screen as shown in the following figure. Touch Offline. c. Touch Main Unit Settings Ethernet Local Settings. Copyright 2014 Moxa Inc. Page 4 of 18

d. Configure the IP address and Subnet Mask fields. 4. For information on other hardware settings, refer to the Configuring Siemens S7-300 PLC with Moxa MGate 4101-MB-PBS. 4.2 Configuring GP-Pro EX 1. Creating a New project a. Start the GP-Pro EX application. b. The Welcome to GP-Pro EX window appears. Select New and click OK. Copyright 2014 Moxa Inc. Page 5 of 18

c. Configure the following Display Unit settings and click Next. Series: Select GP 4000 Series and GP-45** Series from the drop-down lists. Model: Select GP-4501TW from the drop-down list. d. In the Device/PLC screen, configure the following fields and click New Screen: Manufacture: Select Siemens AG from the drop-down list. Series: Select SIMATIC S7 Ethernet from the drop-down list. Port: Select Ethernet (TCP) from the drop down list. Copyright 2014 Moxa Inc. Page 6 of 18

The system closes the Welcome screen and creates a Base Screen as shown in the following figure 2. PLC Connection Setup a. Click the Project tab and select Device/PLC. b. In the Device/PLC 1 configuration area, click the icon next to PLC1 as indicated in the following figure. Copyright 2014 Moxa Inc. Page 7 of 18

c. In the PLC1 settings screen, configure the following fields and click New: Destination IP Address: Enter the IP address. Connection Type: Select OP Communication from the drop-down list. CPU Rack Number: Enter 0. CPU Slot Number: Enter 2. Use Tag Data: Select this check box. Copyright 2014 Moxa Inc. Page 8 of 18

d. The Add Tag screen appears. Click Add. e. In the Tag List screen, add the tags as shown in the following figure. Copyright 2014 Moxa Inc. Page 9 of 18

3. Using the Edit Screen a. In the Base 1 screen window, use the Text tool to create Text Objects as shown in the following figure. b. In the Parts Toolbox pane, select Data Display from the Parts drop-down list and drag a data display element to the screen next to Temperature. Copyright 2014 Moxa Inc. Page 10 of 18

c. Double-click the Data Display element to configure its properties. i. Click the icon next to the Monitor Word Address field and select the DisplayTemperature tag. ii. Click Ent. iii. From the Data Type drop-down list, select 32 Bit Float. Copyright 2014 Moxa Inc. Page 11 of 18

d. Click the Display tab and set the Decimal places field to 1; then, click OK. Copyright 2014 Moxa Inc. Page 12 of 18

e. Copy the Data Display element next to Temperature and paste it next to Drive Speed. f. Click the icon next to the Monitor World Address and change the tag name to DisplaySpeed. Copyright 2014 Moxa Inc. Page 13 of 18

g. In the Parts Toolbox pane, select Switch from the Parts drop-down list and drag a Switch element next to Start Drive and Stop Drive. Then, change the color of the Switch element for Start Drive to green. h. Double-click the Start Drive Switch element to configure its properties. In the Switch Feature tab, configure the following fields and click OK: Bit Address: Select StartDrive from the drop-down list. Bit Action: Select Bit Set from the drop-down list. Copyright 2014 Moxa Inc. Page 14 of 18

i. Double-click the Stop Drive Switch element to configure its properties. In the Switch Feature tab, configure the following fields and click OK: Bit Address: Select StartDrive from the drop-down list. Bit Action: Select Bit Reset from the drop-down list. 4. Transferring a Project After you edit a screen, save the project. a. Click Transfer Project to transfer a project to Pro-face GP-4501TW. Copyright 2014 Moxa Inc. Page 15 of 18

b. In the Transfer Tool window, click Send Project. Copyright 2014 Moxa Inc. Page 16 of 18

c. The Select Display Unit window displays the list of online Pro-face HMI devices. Select to enable the Pro-face GP-4501TW device and click OK to transfer the project. 5 On-line Test The Pro-face GP-4501TW panel displays Temperature (in degree Celsius) that is read from IAQPoint2 and Drive Speed from Power Flex 4M. Drive Speed is 0.0 because PowerFlex 4M is in Stop Mode. Copyright 2014 Moxa Inc. Page 17 of 18

Click the Switch element for the Start Drive to set the StartDrive tag. PowerFlex 4M is now in Start Mode and Drive Speed is greater than 0.0 as shown in the following figure. Copyright 2014 Moxa Inc. Page 18 of 18