The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects



Similar documents
Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)

Gigabit Ethernet on Copper Cabling Infrastructures

Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Enhanced Category 5 Cabling System Engineering for Performance

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

Total Solutions Verification

How to Choose the Right Cable Category

This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:

SYSTIMAX Copper Solutions Designed for the Digital Generation

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Network Design. Yiannos Mylonas

Data Communications Competence Center

Copper Patch Cords. Impact On Network Performance and Reliability

The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT

Planning for 10Gbps Ethernet over UTP Questions to Ask When Planning the Cabling Plant WHITE PAPER

Category-6 / Class-E Cabling

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

PANDUIT TX6 10GIG SHIELDED COPPER CABLING SYSTEM. Innovative Connectivity Solution for Maximum Performance and Security

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

White Paper. Cat. 6A vs. Cat. 6 A. What s the Difference and Why Should I Care?

HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)

White Paper: 10 Gigabit Ethernet over Twisted Pair Copper Systems

The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen

Understanding the Electrical Performance of Category Cables

An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware

Abstract: This document examines the alien NEXT performance of various bundled cables and measures the impact upon various networks performance.

Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk

Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka

Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

IT Cabling Solutions

Cable Sharing in Commercial Building Environments

Cabling for 10GBASE-T and Beyond - A Tangled Web

Future Proofing with Category 7 and 7A Cabling for 25 and 40GBASE-T Carries High Levels of Risk

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Innovative Connectivity Solution for Maximum Performance and Security

Physical Infrastructure trends and certification requirements for Datacenters. Psiber s Global Village

Copper Cabling Troubleshooting Handbook

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

Category 6 UTP - Cabling System

ATT-TP Ethernet Copper Cable & Ethernet Copper Assembly Specification

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Ethernet Patch Cord Wiring

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

Cat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards.

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

Requirements for Modular Patch Cords (e.g. RJ45 patch cords for Cat5 and Cat6 cabling systems)

Specifying an IT Cabling System

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

GigaSPEED X10D Solution How

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

Chapter 4 Connecting to the Internet through an ISP

How To Get A Better Signal From A Fiber To A Coax Cable

Implementing Fast Ethernet

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

European Normative EN system

Part 1: General Requirements TELECOMMUNICATIONS INDUSTRY ASSOCIATION

Nexus Technology Review -- Exhibit A

Security & Surveillance Cabling Systems

Category 6 Cabling Questions and Answers

Data Center Design for 40/100G

2. What is the maximum value of each octet in an IP address? A. 128 B. 255 C. 256 D. None of the above

Application Note: How to Connect a Wired Ethernet Port to the WiPort

Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

with Component Rating A Simple Perspective

Gigabit Ethernet over fiber optic cable.

PowerNet Network Communications Guidelines. Application Notes

RTEX Cable 2015/10/1. Motor Business Unit Automotive & Industrial Systems Company Panasonic Corporation

CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections

LAN Installation Handbook

CATEGORY 8: UNDERSTANDING THE NEW CATEGORY OF PERFORMANCE FOR BALANCED TWISTED PAIR CABLE

ANSI/TIA/EIA A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD

Cat 6 Cable: Copper s Last Stand? Cat 6 Cable is craft intensive! Advanced Installation & service skills are a MUST.

WHITE PAPER December, 2001

Discussion Paper Category 6 vs Category 5e Cabling Systems and Implications for Voice over IP Networks

CCNA Discovery Chapter Four

Network Engineers Everywhere:

advancing information transport systems advancing information transport systems

New Technology Developments and How They Impact Your Structured Wiring Choices

Broadband Video over Twisted Pair Cabling. By Paul Kish Director, IBDN Systems & Standards NORDX/CDT

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

Ethernet and UTP Cabling from 10BASE-T to 10GBASE-T

Structured and Point to Point Network Cabling for Industrial Automation

White Paper. Crestron 8G DigitalMedia Cable

This application note is written for a reader that is familiar with Ethernet hardware design.

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Cabling Standards Update 2014

Attaching the PA-A1-ATM Interface Cables

Data Centre & Enterprise Solutions. RapidNet

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

Method for improving Return Loss in order to reduce PHY power Ron Nordin Panduit Bob Wagner Panduit Paul Vanderlaan Berk-Tek

Terminating 25-Pair Cable and 4-Pair Cross Connects

Managing Physical Security Risk in Physical Layer Infrastructure Solutions

B. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection.

Transcription:

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0

Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling Standard has been ratified, it is an opportune time to discuss the evolution of this standard. The TIA/EIA-568-A Commercial Building Telecommunications Standard was published in 995. This document was written for Category 5, 00-ohm copper cabling systems. At the time the IEEE 80. committee had just developed the standard for the 00 Base-T Ethernet transmission system. This transmission system was developed to replace the previous version of Ethernet, which was 0 Base-T. The 0 Base-T transmission standard provided signal transmission of up to 0 MHz of bandwidth over Category ; usually Unshielded Twisted Pair (UTP) copper cabling. Category cable was also available in Shielded Twisted Pair (STP) and Screened Twisted Pair (ScTP) cables as well, but UTP was the preference throughout the network communications cabling industry. 00 Base-T Ethernet systems require up to 00 MHz of bandwidth. Category cabling systems could not support this bandwidth. Therefore, Category 5 cabling was developed and introduced to support 00 MHz bandwidth Ethernet transmission systems. When the TIA/EIA -568-A standard was introduced, it was projected that this cabling standard would support transmission systems for the next fifteen years. This paper will address the accuracy of that prediction. TIA-EIA-568-A The TIA-EIA -568-A standard defined the testing limits for the following parameters for testing Category 5 cabling installations: Length, Attenuation, Wiremap and Near End Crosstalk (NEXT). The length requirements defined that the maximum length a cable could be run from a Telecommunications Room to a work area outlet in a commercial building could not exceed 90 meters (95 feet). This 90-meter distance is defined as the horizontal link. When adding patch cables in the Telecommunications Rooms to either cross-connect or interconnect with electronic equipment and to connect devices at the work area outlet, the standard allows for a total of ten meters for these patch cables to be added to the horizontal link. This 00 meter maximum distance, the maximum 90-meter horizontal link plus 0 meters of patch cords, is defined as the horizontal channel. Attenuation is the loss of signal strength as it is transmitted from the end of the cable which the signal is generated to the opposite end at which it is received. Attenuation, also referred to as Insertion Loss, is measured in decibels (db). For attenuation, the lower the db value, the better the performance, less signal is lost. This decrease is typically caused by absorption, reflection, diffusion, scattering, deflection, or dispersion from the original signal and usually not as a result of geometric spreading. Wiremap is a continuity test. It assures that the conductors that make up the four twisted pairs in the cable are continuous from the termination point of one end of the link to the other. This test assures that the conductors are terminated correctly at each end and that none of the conductor pairs are crossed or short-circuited. Near End Crosstalk (NEXT) measures the amount of signal coupled from one pair to another within the cable caused by radiation emission at the transmitting end, near end, of the cable. An example of crosstalk on voice channels is when extraneous conversations can be heard in the background over the phone line while on a telephone conversation. Those signals are being induced onto the voice channel from another channel. The same instance occurs in data signal transmission. If the crosstalk is great enough, it will interfere with signals received across the circuit. Crosstalk is measured in db. The higher the db value the better the performance, more of the signal is transmitted and less is lost due to coupling. (Fig. ) Page of 6

NEXT TX Signal Coupling Figure 00 Base-T signals are transmitted across only two of the pairs in the cable. One pair is used to transmit signals and the second pair receives the signals. The other two pairs in the cable are not used at all in 00Base-T signal transmission. As technology advanced during the late 990 s, there was a demand generated by computer manufacturers and chip vendors to promote the use of more powerful computers and more powerful applications such as D graphics and full motion video. This demand would exceed the capabilities of 00 Base-T signal systems. Therefore the IEEE 80. committee went to work to develop the 000 Base-T (Gigabit) Ethernet standard that would provide billion cycles of bandwidth over Category 5 copper twisted pair cabling. Although 000 Base-T Ethernet was designed to function over Category 5 cabling systems, the margins were very slim. 00 Base-T signals utilize only two of the four pairs in the cable and the signals only run in one direction across the pairs. 000 Base-T signals require all four pairs in the cable to be utilized to transmit up to 50 megabits of data per second (Mbps) in full duplex transmission across each pair. Full duplex transmission requires each of the pairs to be able to transmit and receive signals simultaneously. Therefore, the need for additional field test requirements such as ELFEXT and Return Loss was raised. These test parameters were defined for two connection points in TIA/EIA Technical Services Bulletin (TSB) 95. Equal Level Far End Crosstalk (ELFEXT) measures the coupling of signals due to radiation emission measured at the end of the cable that is opposite from where the signal is generated, the far end. ELFEXT also takes into consideration the attenuation factor over the length of the cable. Return Loss measures the amount of signal that is reflected back to the source from which the signal was generated. Return Loss is created by impedance mismatches of the components in the link or channel and by distortion to the physical geometry of the cable, which may be caused by tight bends or cable ties being cinched too tightly. These additional tests are required to assure that an existing Cat 5 installation can support 000 Base-T transmission. Due to the fact that the margins for running 000-Base-T over Cat 5 cabling were so slim, a move was made to develop an enhanced cabling system that would support it with a wider margin. This was the birth of the Cat 5e cabling systems. TIA/EIA-568-A-5 The standard that defined the requirements for Cat 5e was TIA/EIA -568-A-5 and was ratified in 999. Category 5e, like Cat 5, is a 00 MHz transmission scheme. Required field test parameters for Category 5 link and channel performance, as well as those required for manufacturers lab tests, have been raised to a higher level to certify for Cat 5e transmission. ELFEXT and Return Loss minimum performance requirements are defined for worst case, four connector channels, utilizing full duplex transmission schemes such as Gigabit Ethernet. The four-connector scheme accommodates a Consolidation Point implemented in the horizontal cabling link. In May 00 the TIA/EIA -568-B Standard was ratified and Page of 6

released for publication. The 568-B standard incorporates all of the previous 568-A addenda and TSBs into a document that is divided into three separate sections, 568-B., 568-B., and 568-B.. TIA/EIA-568-B TIA/EIA-568-B. defines the general cabling requirements for copper and fiber cabling installations. 568-B. defines the specific requirements for copper cabling installations and component requirements for Cat and Cat 5e systems. Category 5 cabling is not recommended in 568-B.. Cat 5 has been placed in Annex N in the document and is only recognized for legacy installations where Cat 5 already exists. 568-B. defines the specific requirements for optical fiber systems. The 568-B. standard defines that field testing shall be done according to the Permanent Link scheme. Permanent Link testing replaces the Basic Link testing scheme as was defined in previous standards. The Permanent Link test looks at the permanently installed cabling and components from the termination at the work area outlet to the termination point in the Telecommunications Room. It does not allow for any patch cords or test leads. The Basic Link test accounted for two meters at each end of the link, four meters total, to accommodate test leads. The Permanent Link test ignores the test leads. In addition to the field tests that have been outlined previously in this paper, additional tests are required in 568- B.. These additional tests are: Power sum NEXT (PSNEXT), Power sum ELFEXT (PSELFEXT), Propagation Delay, and Delay Skew. Attenuation is now referred to as Insertion Loss. Power sum NEXT measures the crosstalk in the cable at the near end. However rather than measuring the signal coupling from one pair to another pair within the cable, Power sum NEXT measures the effects of the coupling from the other three pairs in the cable against each of the individual pairs. Power sum ELFEXT measures the crosstalk at the far end of the cable, and again, considers the effects of the other three pairs on each individual pair while also considering the attenuation factor. (Fig.). ELFEXT <<<=Attenuation Near End Figure Far End Page of 6

Propagation Delay is the time (measured in nanoseconds ns) that it takes for the signal to be transmitted from one end of the cable to the other. Delay skew measures the difference of the speed of signal transmission between the fastest and slowest pairs in the cable. The Delay Skew must be less than 50 nanoseconds (ns) for a 00-meter channel. The International Organization for Standardization (ISO) developed the ISO 80 cabling standard. This standard is in harmony with the TIA/EIA -568-B standard. The ISO 80 document defines 00 MHz cabling systems as Class D. The parameters and requirements for Class D cabling are similar to the TIA 568B requirements for Cat 5e. The ISO 80 Class E requirements are parallel to the TIA/EIA 568B.- Category 6 Standard that was ratified in May 00. TIA/EIA 568B.- Category 6 Standard Category 6 cabling was originally intended to yield 00 MHz of bandwidth. The IEEE requested that all testing be done to 50 MHz to assure that Cat 6 systems will operate with plenty of margin. All of the aforementioned field and manufacturer testing requirements also apply for Cat 6, except that the testing is done to 50MHz. The Cat 6 standard provides the best performance specification for UTP and ScTP cabling systems. The requirements for Cat 6 cabling are much more stringent than they were for Cat 5 and Cat 5e. It is very important that installers maintain ½ or less of untwist at the termination, proper bend radius, and avoid short links, less than 5 meters. When properly installed, Cat 6 cabling systems will provide far better performance than Cat 5e. The frequency range is more than double than for 5e, at 50 MHz, where 5e is at 00 MHz. Cat 6 performance requirements are also significantly better than Cat 5e when compared at the same frequencies. (Table ) TIA/EIA 568B Channel Performance Comparison Parameter Cat 5e Cat 6 Frequency Range 00 MHz 50 MHz Propagation Delay 58 ns @ 00 MHz 58 ns @ 00 MHz 56 ns @ 50 MHz Delay Skew 50 ns 50ns Insertion Loss db. db @ 00 MHz 6 db @ 50 MHz NEXT 0. db 9.9 db @ 00 MHz. db @ 50 MHz PSNEXT 7. db 7. db @ 00 MHz 0. db @ 50 MHz ELFEXT 7. db. db @ 00 MHz 5. db @ 50 MHz PS-ELFEXT. db 0. db @ 00 MHz. db @ 50 MHz Return Loss 0 db 8.6 db @ 00 MHz 8 db @ 50 MHz Table Category 6 cabling systems utilize RJ-5 connectors and are backward compatible to Cat 5e. This means that if Cat 6 and Cat 5e components are mixed in a channel, the channel will perform to Cat 5e limits. Cat 6 cabling will run Gigabit Ethernet more efficiently than Cat 5e because it is a better performing system. The Cat 6 standard also provides the requirements for manufacturers to test patch cords. Cat 6 is an interoperable standard, Cat 6 rated components from different manufacturers can be mixed in the channel and the channel should still perform to Cat 6 limits. This includes patch cords. To assure interoperability for connectors, manufacturers are now required to conduct a de-embedded plug test for their components. The de-embedded plug test utilizes an industry standard common plug to be mated with the jacks under test Page 5 of 6

to isolate the performance of the jack. With all manufacturers required to utilize the same plug design for this test, it assures interoperability and creates a level playing field for the manufacturers db 50 0 00 Meter Channel Power Sum ACR Cat 5e Cat 6 Cat 6 Test 0 00 00 00 00 Frequency (MHz) Figure 50 Bandwidth is determined by Attenuation to Crosstalk Ratio (ACR) or Attenuation to Power Sum Crosstalk Ratio (PSACR) (Fig ). International standards require these tests, but they are not required in the TIA standards. Attenuation to Crosstalk Ratio is not a measurement; it is a calculation. It is determined by subtracting the Insertion Loss db value from the NEXT db value. This parameter defines how much greater the signal strength is than the noise, or unwanted signals, on the circuit. It defines the amount of headroom in the system. Headroom defines the difference between the available bandwidth and the bandwidth that is actually used. It is similar to filling 8 ounces of liquid in a -ounce glass, there are ounces of headroom. When the ACR equals zero, the noise is equal to the signal and there is no remaining bandwidth. Beyond that, it is running at a negative bandwidth, which means there is nothing but noise being transmitted. PSACR is determined by using the PSNEXT value in the calculation. The graph above indicates the PSACR limits for Cat 5e and Cat 6 channels as indicated in the standards with the solid lines. The erratic lines indicate the actual performance of the cabling showing how the link performs beyond the limits of the standard. Conclusion A structured cabling system to support Category 5e and Category 6 installations requires many different components. In the Telecommunications Room, racks, patch panels, connecting blocks, patch cords, RJ-5 jacks, and cable management devices are required. At the work area outlet, RJ-5 jacks, faceplates, patch cords, raceway and boxes are needed. The horizontal cable is run between these two spaces. A Consolidation Point or Zone Cabling box may be required as part of the horizontal cabling. All cabling and termination devices must be rated for the appropriate category as defined by the standards. PANDUIT Corp. is an industry leader in network connectivity and structured cabling solutions. PANDUIT provides a full line of products to provide an end-to-end solution for all of your cabling needs, PANDUIT is a global leader providing innovative networking solutions to enable technology, including modular twisted pair and fiber optic connectors, UTP copper cable, outlets, racks and cable management, raceway systems, fiber routing systems, physical layer management systems, identification systems, cable ties and accessories and grounding systems. The PANVIEW Physical Layer Management System monitors and helps manage and maintain the network. PANDUIT solutions are factory tested to exceed industry standards requirements and to support emerging technologies including Gigabit Ethernet, Voice over IP, Power over Ethernet, and Zone Cabling. Page 6 of 6