CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections
|
|
|
- Victoria Heath
- 9 years ago
- Views:
Transcription
1 CAT 5 Cable / RJ 45 Connectors and Making Cables for different connections RJ 45: (RJ xx: telephone connection interfaces, registered with the FCC, the U.S. Federal Communications Commission.) Pins: When you are looking at the wiring end (the entryway for the cable to be inserted into the connector) of a plug with the latch down, pin 1 is on the left. CAT 5: 4 Twisted Pairs at 24 AWG pair 1: blue pair 2: orange pair 3: green pair 4: brown (twisted about 3 times per inch) Ethernet uses only pair 3 (green, on pins 1 and 2), and pair 2 (orange, on pins 3 and 6). EIA/TIA specifies RJ-45 (ISO 8877) connectors for UTP cable (unshielded twisted pair). Impedance: 100 Ohms Max length of a segment: 100 meters/330 feet Frequency rating: 100MHz Capacitance: 13.5 to 17 picofarads per foot Attenuation: 23 to 67dB per 1000 feet Far-End Crosstalk (FEXT): 32 to 51 db at 1000 feet CAT 5 Cable Specifications: Max. Attenuation per 1000 ft/ Resistance per 1000 ft/ Frequency 304 m 304 m Capacitance Impedance 4 MHz 13 db 28,6 ohms 14 pf/ft 100 ohms 10 MHz 20 db 28,6 ohms 14 pf/ft 100 ohms 20 MHz 28 db 28,6 ohms 14 pf/ft 100 ohms 100 MHz 67 db 28,6 ohms 14 pf/ft 100 ohms
2 How to make a good CAT5 Cable. A good CAT5 termination provides you a connection that has the following important characteristics: a proper wire crimp, a wire insulation strain relief crimp and a cable strain relief crimp. REMEMBER To avoid NEXT and FEXT problems, it is also important to not unwind the wires more than necessary. Conversely, while maintaining the twists as far as possible is important, don't let it stop you from inserting the wires as far as possible. I've made a lot of these cables personally, and this is how I do it: * Strip the cables Jacket back one full inch. * Untwist the wires back to within 1/8" of the jacket. * Arrange the wires in the order in which you want to crimp them, (ie. 568A, 568B, etc.). * Grasp the wires firmly, between your thumb and forefinger, flatten them, and even wiggle them a bit, to take out the curliness, (concentrate your efforts on the bottom 1/2") the wires must lay flat and together, aligned as close as possible. * While holding the wires firmly, cut off the the wires 1/2" from the cables jacket (Cut the wires with some sharp wire strippers or even high quality scissors, avoid wire cutters that flatten the ends of the wires insulating material, this makes stuffing the wires very difficult.) * Stuff the wires into the connector, making sure the wires stay lined up. NOTE: The wires should reach the end of the little tube they are in, if possible, or at least past the farthest point of that "little funny Gold Plated thingy" above it, which will terminate it. * The jacket should go even with the end of the first indent, if possible, as it's a strain relief for the cable. * Insert it into the crimping tool, and Crimp it! All of this is very dependant on the tools you are using, the connectors you are using, and the cable you are using. A bad combination can be hell! How to wire a CAT5 (EIA 568-B*) Cable. connector #1 connector #2 1 WHT/ORG 2 ORG/WHT 3 WHT/GRN 6 GRN/WHT How to wire a CAT5 (EIA 568-A*) Cable. 1 WHT/ORG 2 ORG/WHT 3 WHT/GRN 6 GRN/WHT connector #1 connector #2 1 WHT/GRN 1 WHT/GRN *The real difference between 568A and 568B is that the White/Orange-Orange/White and White/Green-Green/White pairs are swapped. Crimp strain relief: Cable jacket should be inserted past the strain relief crimp (see picture).
3 How to wire a "Crossover" Cable. (EIA 568-B*) connector #1 connector #2 1 WHT/ORG 2 ORG/WHT 3 WHT/GRN 6 GRN/WHT USOC crossover cables are like this: 1 WHT/GRN 7 BRN/WHT 8 WHT/BRN 1 WHT/BRN 2 WHT/GRN 4 WHT/BLU 5 BLU/WHT 7 GRN/WHT 8 WHT/BRN 7 WHT/GRN 6 WHT/ORG 3 ORG/WHT 1 BRN/WHT 10BaseT and 100BaseT Cross Cable C1 Pins Color Code Color Code C2 Pins 1 White/Orange White/Green 1 2 Orange Green 2 3 White/Green White/Orange 3 4 Blue Blue 4 5 White/Blue White/Blue 5 6 Green Orange 6 7 White/Brown White/Brown 7 8 Brown Brown 8 color abbreviations: WHT-WHITE BRN-BROWN ORG-ORANGE GRN-GREEN BLU-BLUE The first color listed in the color pair is dominant color of the wire. In other words, WHT/ORG is a white wire with orange stripes.
4 ISDN BRI RJ45 Standard ( MO97): RJ 45 Pin Pair Tx+ Rx + Rx - Tx - ISDN PRI RJ45 Standard ( MO97): RJ 45 Pin Pair Tx+ Rx + Rx - Tx - (T1 PRI X-Over = Essentially, tie Pins 1[connector 1] P4[connector 2] and P2[connector 1] P5[connector2], then Pins 1[connector 2] P4[connector 1] and P4[connector 2] P5[connector1]) 10BaseT and 100BaseT Cross Cable C1 Pins Color Code Color Code C2 Pins 1 White/Orange White/Green 1 2 Orange Green 2 3 White/Green White/Orange 3 4 Blue Blue 4 5 White/Blue White/Blue 5 6 Green Orange 6 7 White/Brown White/Brown 7 8 Brown Brown 8 (Ethernet X-Over = Essentially, tie Pins 1[connector 1] P2[connector 2] and P3[connector 1] P6[connector2], then Pins 1[connector 2] P2[connector 1] and P3[connector 2] P6[connector1]) Cat5 Wiring Standards, Listed Pin EIA/TIA 568A AT&T 258A, EIA/TIA 568B 10Base-T 10Mbps Cat3 100Base-TX 100Mbps Cat5 100Base-T4 100Mbps Cat3 100Base-T2 100Mbps Cat3 1000Base-T 1Gbps Cat5+ 1 white/green white/orange TX+ TX+ TX D1+ BI DA+ BI DA+ 2 green/white orange/white TX- TX- TX D1- BI DA- BI DA- 3 white/orange white/green RX+ RX+ RX D2+ BI DB+ BI DB+ 4 blue/white blue/white na na BI D3+ na BI DC+ 5 white/blue white/blue na na BI D3- na BI DC- 6 orange/white green/white RX- RX- RX D2- BI DB- BI DB- 7 white/brown white/brown na na BI D4+ na BI DD+ 8 brown/white brown/white na na BI D4- na BI DD- BI=BI directional data RX=Receive Data TX=Transmit Data
5 Testing CAT5 Cable Since the Cat 5 cable is used to the fullest extent of its performance envelope, testing is very important. There are four basic tests that are called for as part of the EIA/TIA specs for all UTP cables: wiremap, length, attenuation and crosstalk. Let's take a look at each of them. Wiremap Wiremapping simply means that each wire is hooked up correctly, with no open wires or shorts. That's mostly very straightforward. Each pair must be connected to the correct pins at the plugs and jacks, with good contacts in the terminations (called "IDC" or insulation-displacement connections, by the way, since the wires are held in knife-edge terminations that slice through the insulation and dig into the copper wire, forming a tight seal.) Most of the failures are simple enough to understand, like reversed wires in a pair, crossed pairs or opens and shorts. One possible failure is crossed pairs, caused when both wires of a pair are crossed at one termination. The usual cause of a crossed pair is a 568A termination on one end and a 568B on the other. The most difficult wiremap problem is a split pair, when one wire on each pair is reversed on both ends. The usual wiremap will pass but crosstalk will fail. It takes a Cat 5 tester or a more sophisticated wiremapper to find a split pair, as most wiremappers do not check crosstalk. Length Since 568 cables must be less than 90 meters (296 feet) in the link and 100 meters in the channel (328 feet), length must be tested. This is done with a "time domain reflectometer" which is a fancy term for cable "radar". The tester sends out a pulse, waits for an "echo" from the far end and measures the time it took for the trip. Knowing the speed in the cable, it calculates the length. If you have a short or open, the TDR will tell you where the problem is too, making it a great tool for finding problems. Attenuation The proper operation of a LAN on the cable plant requires the signal strength be high enough at the receiver end. Thus the attenuation of the cable is very important. Since LANs send high speed signals through the cable and the attenuation is variable with the frequency of the signal, the fancy automated testers test attenuation at several wavelengths specified in the 568 specs (TSB-67 to be exact). This test requires a tester at each end of the cable, one to send and one to receive, then one of them will calculate the loss and record it. There are pass fail criteria for the cable at Cat 3, 4 and 5 max frequencies. Crosstalk (NEXT) It's called NEXT for "near end cross talk" since it measures the crosstalk (signal coupled from one pair to another) at the end where one pair is transmitting (and the transmitted signal is largest causing the most crosstalk.) Crosstalk is minimized by the twists in the cable, with different twist rates causing each pair to be antennas sensitive to different frequencies and hopefully not picking up the signals from it's neighboring pairs. Remember what we said: you MUST keep the twists as close to the terminations as possible to minimize crosstalk.
6 Cat 5 testers measure crosstalk from one pair to all three other pairs for each pair and compare it to the 568 specs, giving a pass/fail result. Some also calculate "ACR" or attenuation/crosstalk ratio, as it is a measure of how big the crosstalk signal is to the attenuated signal at the receiver. You want this number as big as possible, as it is an indication of the signal to noise ratio. More Tests Coming Soon! The next generation of test specs will probably include a number of new tests to insure higher performance from the cable. These tests relate to higher bandwidth usage of the cable and simultaneous use of all four pairs, perhaps even in both directions at once! Powersum NEXT is the NEXT on one pair when all three others are carrying signals. This is realistic with Fast Ethernet and Gigabit Ethernet where all pairs carry signals, often simultaneously. Manufacturers routinely test cables for this characteristic now, but there is no standard yet for the performance of the cable or terminations. FEXT is far end crosstalk, looking at the effect of the coupling from one pair to another over the entire length, measured at the far end. ELFEXT is equal level FEXT, or the ratio of FEXT to attenuation, sort of like ACR. Delay Skew measures how much simultaneous pulses spread out at the far end. This measures the speed on each pair, which may be different due to the variations in number of twists (more twists means longer wires) or insulation. Return loss is a measure of the reflections from the cable due to variations in the impedance. These reflections can cause signal degradation, especially if the pairs are used in a fullduplex (bidirectional) mode. Testers UTP testers are mostly automated, push a button get a pass/fail simple. Wiremappers test the connections and Cat 5 testers test the performance at high frequencies. In fact, Cat 5 testers test everything, wiremap, length, attenuation and crosstalk in one connection, give you a pass/fail result, some help on troubleshooting, store the result and practically everything else but make coffee. Some installers use the Cat 5 tester for all testing, after the cable is installed. Others have each crew use an inexpensive wiremapper to make sure connections are correct before the Cat 5 tester is brought in, since it's a very expensive unit that needs a trained operation and many failures are simply wire map problems. By having each crew find and fix their own wiremap problems, testing and corrections are done as the cable is installed and the cost of the Cat 5 tester is not wasted on simple problems. It just provides the high frequency tests and documentation required by most users. Buying a Cat 5 tester today is a bit of a crap-shoot, since everybody knows the 568 spec will be upgraded to include more tests at higher frequencies soon, but nobody knows exactly how far. 155 MHz, 200 MHz, 250 MHz, higher? The best bet is to not buy a unit that is not already rated to higher frequencies or that cannot be upgraded easily! What The Heck Is A Certified Cable? Did the cable pass an exam and get a certificate? Well, sort of. This term has been used by vendors of testers to mean that the cable was tested and passed by one of the Cat 5 testers. It means that it meets the minimum specifications of TSB067 and should work with any network designed to operate on a Cat 5 link. This information researched and provided by Communication Design Group
This paper will explain some of the more important factors on how UTP wires work; specifically it will cover the following:
UTP Technology In the late 1970s, unshielded twisted pair (UTP) cabling originated in the computer industry as a means of transmitting digital data over computer networks. This cable was designed to be
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP)
Cable Specification Category 5e CMP HIGH SPEED COMMUNICATIONS PLENUM CABLE CATEGORY 5e CMP FEP JACKETED, PVC-FREE UNSHIELDED TWISTED PAIR (UTP) This cable specification complies with the electrical transmission
Communication, Signal & Data Cables
Communication, Signal & Data Cables Used for indoor installation and interconnection of transmission, telephone, telegraph and electronic equipment as well as media equipments www.alfanar.com Communication
HOW TO MAKE YOUR OWN CAT 5 TWISTED-PAIR NETWORK CABLES http://www.duxcw.com/digest/howto/network/cable/index.htm
HOW TO MAKE YOUR OWN CAT 5 TWISTED-PAIR NETWORK CABLES http://www.duxcw.com/digest/howto/network/cable/index.htm INTRODUCTION. The purpose of this article is to show you how to make the two kinds of cables
Ethernet Cat 5e & Cat 6 Patch Panels
Ethernet Cat e & Cat Patch Panels Copper :: RJ/IDC Models EPPE-CTE & EPPE-CAT User Manual Applys to : EPPE-CTE :: EPPE-CAT Telect, Inc., All Rights Reserved, 9- A0.09.9.000 :: telect.com Ethernet Cat e
Christopher Rathgeb ECE 453 Dr. Qi 9/19/2006. Task 1: Make an Ethernet cable yourself.
Task 1: Make an Ethernet cable yourself. Christopher Rathgeb ECE 453 Dr. Qi 9/19/2006 You are required to make the cable within 20-minute period of time in FH422 (the networking lab). The TA will be there
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk
Installation Effects Upon Alien Crosstalk and Equal Level Far End Crosstalk Paul Vanderlaan Product Development Engineer Belden Presented at BICSI January 20, 1999 Introduction New Parameters involving
Chapter 2 TCP/IP Networking Basics
Chapter 2 TCP/IP Networking Basics A network in your home or small business uses the same type of TCP/IP networking that is used for the Internet. This manual provides an overview of IP (Internet Protocol)
Enhanced Category 5 Cabling System Engineering for Performance
Engineering for Performance Table of Contents 2 Introduction 2 Where Did It Come From? 2 Enhanced Category 5 Performance What to Test The Link The Channel Don t Forget the Cable Assembly 4 Performance
Network Cabling Guide
Network Cabling Guide Poor or incorrectly installed network cabling can cause numerous problems with your computer network. Whilst we recommend that you employ a network / cabling specialist to wire and
iseries Ethernet cabling and configuration requirements
iseries Ethernet cabling and configuration requirements iseries Ethernet cabling and configuration requirements Copyright International Business Machines Corporation 1999, 2000. All rights reserved. US
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel Introduction When network managers decide on a cabling system,
Appendix B Network, Routing, Firewall, and Basics
Appendix B Network, Routing, Firewall, and Basics This chapter provides an overview of IP networks, routing, and networking. Related Publications As you read this document, you may be directed to various
Ethernet Patch Cord Wiring
Ethernet Patch Cord Wiring C ONTENTS Ethernet Patch Cords & RJ-45 Connectors... 2 Ethernet Patch Cords and UTP Cabling... 3 What s all the twisting about?... 4 Ethernet Applications... 5 568A & 568B Wiring
Standards Affecting a Premise T-1 Installation
Standards Affecting a Premise T-1 Installation The T-carrier system originated many years ago as a technology developed by AT&T. The intended use of the scheme was to increase the voice channel capacity
Crestron CAT5 Wiring Reference Guide
Crestron CAT5 Wiring Reference Guide This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All
ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.
WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of
Gigabit Ethernet on Copper Cabling Infrastructures
Gigabit Ethernet on Copper Cabling Infrastructures Overview of Gigabit Ethernet (1000Base-T) Ethernet was developed by the Xerox Corporation in the early 1970 s and has emerged as the dominant networking
Terminating 25-Pair Cable and 4-Pair Cross Connects
Terminating 25-Pair Cable and 4-Pair Cross Connects Estimated Time: 90 minutes Number of Teams: 2 Number of Team Members: one to four This Lab has four major parts that will be addressed separately. 1.
An Engineer s Guide to Full Compliance for CAT 6A Connecting Hardware
for CAT 6A Connecting Hardware Written by: Antoine Pelletier Engineer, Global Cabling Products Intertek www.intertek-etlsemko.com 1-800-WORLDLAB Introduction The telecommunication industry recently achieved
INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION
TÜRK TELEKOMÜNİKASYON KASYON A.Ş. DIRECTORSHIP OF OPERATION AND MAINTENANCE Operation Directorate of Access Networks INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION ANKARA 2008 CONTENTS 1.
Total Solutions Verification
Total Solutions Verification 3rd Party Electrical Performance Testing Author: Tom Boucino Applications Engineer Uniprise Solutions CommScope has always designed cables with connectivity in mind. Our engineers
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS
. HARTING RJ INDUSTRIAL ETHERNET CONNECTORS Ethernet is is coming up to standard industrial interface. Therefore, automation devices such as controllers, sensors and actuators feature possess on one or
Understanding the Electrical Performance of Category Cables
Understanding the Electrical Performance of Category Cables By: Mike Levesque, Mike Karg & Himmeler Themistocle Obsessed with cable solutions. Understanding the Electrical Performance of Category Cables
ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification
ATT-TP-76440 Ethernet Copper Cable & Ethernet Copper Assembly Specification Abstract Presented in this document are the standards to implement Electrical & Optical Ethernet components, cabling, connections,
2 Network Media. Copper Core Cable
Network Media Copper Core Cable After studying this chapter, you will be able to: Match the five forms of electronic signals to the media types on which they travel. Describe the major differences between
The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges
The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges Table of contents Channel, Basic Link and Permanent Link defined....................... 2 Critical Performance Parameters......
Specification SFTP CAT6 Network Cable 23AWG CU
Specification SFTP CAT6 Network Cable 23AWG CU S/FTP CAT6 Shielded S/FTP PVC Cable 23AWG 4pair Solid, Wooden drum 1000 Grey CAT6 600MHZ CM Shielded (S/FTP) Solid Cable: Our CAT6 600MHZ Shielded (S/FTP)
Gigabit Switching Ethernet Media Converters - Product User Guide
Gigabit Switching Ethernet Media Converters - Product User Guide PL0338 Issue3 Introduction These Tyco Electronics Gigabit Media Converters translate between 1000Base-T copper and 1000Base-X fiber optic
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka
Networking 101 (Networking Basics) Presentation to UCHUG - 1/03/07 G. Skalka What is a network? A computer network is two or more computers connected together using a telecommunication system for the purpose
Chapter 4 Connecting to the Internet through an ISP
Chapter 4 Connecting to the Internet through an ISP 1. According to Cisco what two things are essential to gaining access to the internet? a. ISPs are essential to gaining access to the Internet. b. No
VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output
VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output Introduction: VE02AL, VE05AL is designed for VGA +Stereo Audio signal over cost effective CAT5 cable to instead of VGA and
How To Get A Better Signal From A Fiber To A Coax Cable
Gigabit Transmission What s the Limit? Fanny Mlinarsky Page 1 What s the Limit? Speed Faster higher frequency higher attenuation less headroom Distance Longer higher attenuation more jitter less headroom
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet Today s network managers know that modern demands on a network by its users can shrink bandwidth dramatically. Faster computers,
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC. by Paul Kish NORDX/CDT Chair TIA TR 41.8
Evolution of Cabling Standards TIA/EIA ISO/IEC CENELEC by Paul Kish NORDX/CDT Chair TIA TR 41.8 Outline Market trends Standards development where we were where we are where we are going Beyond Category
Data Communications Competence Center
Importance of Cable Balance For Improving Noise Susceptibility Data Communications Competence Center DCCC03101702 July 11, 2007 Summary In a study of category 5e and category 6 UTP cables, a strong correlation
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
Lightning Protection Guide. PTP 400 and 600 SERIES
Technical Note Lightning Protection Guide MOTOROLA POINT-TO-POINT BROADBAND WIRELESS SOLUTIONS MOTOROLA PTP 400 and 600 SERIES WIRELESS ETHERNET BRIDGES Table of Contents Introduction.... 3 Recommended
Installation & Weatherproofing Guide for ENCOM Broadband Radios
Installation & Weatherproofing Guide for ENCOM Broadband Radios Read the following instructions before proceeding with your ENCOM Wireless Radio installation. Keep these instructions in safe location for
How to Choose the Right Cable Category
How to Choose the Right Cable Category Why do I need a different category of cable? Not too long ago, when local area networks were being designed, each work area outlet typically consisted of one Category
Testing 10 Gb/s Performance of Category 6 and 6A Structured Copper Cabling Systems within the Unified Physical Infrastructure SM (UPI)
within the Unified Physical Infrastructure SM (UPI) www.panduit.com WP-11 April 2007 Introduction With the ratification of the IEEE 802.3an 10GBASE-T copper standard, end users now have more media options
LocoNet, the Digitrax Difference
LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on
LAN Installation Handbook
] LAN Installation Handbook LAN Installation Handbook Central Information Management Unit Office of the Prime Minister Version 1.0 April 2003 Contents Section 1 Introduction...1 Section 2 LAN Installation...3
Category 6 UTP - Cabling System
AMP NETCONNECT Category 6 UTP Cabling System...... real Category 6 Performance, both on Component as well as on System level! Owing to the extreme high performance of the AMP NETCONNECT Category 6 UTP
TCP/IP Networking Basics. NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA
TCP/IP Networking Basics NETGEAR, Inc. 4500 Great America Parkway Santa Clara, CA 95054 USA September 2005 2005 by NETGEAR, Inc. All rights reserved. Trademarks NETGEAR and Auto Uplink are trademarks or
Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port
Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port This app note applies to the following Lantronix Products: WiPort BG WiPort NR MatchPort BG MatchPort AR XPort Direct+
2-Pair. Managed SHDSL Ethernet Extender. User s Manual
2-Pair User s Manual 1. Quick Start Guide This quick start guide describes how to install and use the Managed SHDSL Ethernet Extender. This is the Ethernet Extender of choice to extend 10/100 Ethernet
Integrated Home Networks
Integrated Home Networks 8050 Series elephone/data Hubs Instruction Manual & Structured Wiring Guide 8053 8051 8052 8052 multiplex technology, inc. 3001 Enterprise Street, Brea, CA 92821-6213, U.S.A. 714-996-4100
Gigabit Ethernet over fiber optic cable.
1000BaseT 1000BaseFX 100BaseTX 100BaseFX 100BaseLX 100BaseSX 100BaseT2 100BaseT4 100BaseTX 10Base2 10Base5 10BaseT ACR 1000 Mbps, 1 Billion bits per second data transmission over copper cabling. All four
Application Note: How to Connect a Wired Ethernet Port to the WiPort
Application Note: How to Connect a Wired Ethernet Port to the WiPort Lantronix, Inc. 15353 Barranca Parkway Irvine, CA 92618 Tel: +1 (949) 453-3990 Revision A September 2004 Overview This application note
PROFINET Diagnostics Software and Tools
PROFINET Diagnostics Software and Tools Dr. Xiu Ji Static wiring test, diagnostics Live system diagnostics Basics of PROFINET Content PROFINET Diagnostics by Dr. Xiu Ji, Page 2 What is PROFINET? PROFINET
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable
Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable June 10, 2010 Contributors: Yinglin (Frank) Yang CommScope, Inc. Charles Seifert Ixia Ethernet Alliance 3855 SW 153 rd
Network Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
Digital Systems Ribbon Cables I CMPE 650. Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip.
Ribbon Cables A ribbon cable is any cable having multiple conductors bound together in a flat, wide strip. Each dielectric configuration has different high-frequency characteristics. All configurations
R&Mfreenet Advanced Cat 6 A Unshielded Connection Module
R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions
Index. ROPIX P18 Hardware... 3. ROPIX P18 Software... 12 ROPIX P18
Index ROPIX P18 Hardware... 3 I. ROPIX P18 Profile Overview... 3 II. Parameter... 5 Sending Card... 6 Receiving Card... 8 Maintenance Tools... 8 III. ROPIX P18 Installation... 9 Cabinet Assembly... 9 Controlling
Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide
Draper Low Voltage, Remote Control, Serial and Network Wiring Guide Copyright 2007 Draper Inc. Form LV-RC-Serial-Network_Wiring07 Print ed in U.S.A. Draper Low Voltage, Remote Control, Serial and Network
Implementing Fast Ethernet
Implementing Fast Ethernet R The Next Generation of Ethernet Fast Ethernet (also known as IEEE 802.3u or 100BASE-T) is quickly becoming the successor to Ethernet as the network topology of choice. Fast
SECTION 16715 TELECOMMUNICATIONS ACCEPTANCE TESTING
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Testing Publications and Standards B. Inspection and testing procedures for copper and fiber optic cable, RF CATV / MATV systems, and the antenna systems. C. Documentation
Coaxial Cable Solutions Guide
Coaxial Solutions Guide General offers a complete line of Carol Brand Coaxial s for today s sophisticated high-speed, wide-bandwidth electronics products that run over long distances with minimal signal
Zero-Variable Wireless Infrastructure Deployment. Datasheet. Models: BM2HP, BM5HP. Completely integrated Radio
Zero-Variable Wireless Infrastructure Deployment Models: BM2HP, BM5HP Completely integrated Radio Directly plugs into any Antenna that has a Type N female connector Robust Weatherproof Design Overview
D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual
D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch Manual TABLE OF CONTENTS About This Guide... 1 PURPOSE...1 TERMS/USAGE...1 OVERVIEW OF THIS USER S GUIDE...1 Introduction... 2 FAST ETHERNET TECHNOLOGY...2
WHITE PAPER December, 2001
Is Superior Essex Outside Plant Copper Cable Rated Category 3? The applicability of the Category 3 specification to outside plant cables is sometimes misunderstood. This white paper examines that issue,
The Next Generation of Cable Technology. A technology primer from NORDX/CDT By, Eric d Allmen
A technology primer from NORDX/CDT By, Eric d Allmen Foreword The Telecommunications Industry Association (TIA) and the International Standards Organization (ISO/IEC) are actively engaged in the development
Abstract: This document examines the alien NEXT performance of various bundled cables and measures the impact upon various networks performance.
Title: Alien Crosstalk and Network Performance Source: Paul Vanderlaan Belden Electronics Division 2200 US Hwy 27 South Richmond, IN 47374 Phone (765)-983-5811 Fax (765)-983-5825 Email: [email protected]
FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223
FITNESS FACILITY WIRING SPECIFICATIONS NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 CONTENTS: - Scope of work Summary - Equipment list - Technical specifications - Map of data
Panduit 28 AWG Patch Cords Installation Guideline
Panduit 28 AWG Installation Guideline Introduction Panduit is a leading supplier of Structured Cabling Systems and Unified Physical Infrastructure. Panduit solutions enable the physical infrastructure
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY
MICRO SFP+ CONNECTOR & CABLE ASSEMBLY micro SFP+ Connector and Cable Assembly TE Connectivity s (TE) micro SFP+ connector and cable assembly empower you to dream big when designing your communication system.
IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
with Component Rating A Simple Perspective
Cat-6A UTP and Shielded with Component Rating A Simple Perspective Asef Baddar RCDD, DCD Sr. Technical Manager Leviton Middle East Category Specifications Agenda Terminology International & North America
Copper Patch Cords. Impact On Network Performance and Reliability
Copper Patch Cords Impact On Network Performance and Reliability 1 The Impact of Copper Patch Cords on Network Performance and Reliability As network infrastructures continue to have a higher impact on
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit
Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input
VOPEX-C5HDMI-4 HDMI Digital Video and Audio Splitter/Extender via CAT6 Installation and Operation Manual
VOPEX Series VOPEX-C5HDMI-4 HDMI Digital Video and Audio Splitter/Extender via CAT6 Installation and Operation Manual VOPEX-C5HDMI-4 Front and ear View ST-C5HDMI-150 emote Unit Front and ear View (Sold
Network Engineers Everywhere:
Network Engineers Everywhere: Relax Your Minds Not Your Standards DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Commercial Ethernet Patch Cable The Strongest Link. DataMax Patch Cable
Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide
GB05-6 Peak Atlas IT RJ45 Network Cable Analyser Model UTP05 Designed and manufactured with pride in the UK User Guide Peak Electronic Design Limited 2001/2012 In the interests of development, information
Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide
Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT Active Speaker System with remote input LX523 User Manual & Installation Guide AUDAC PROFESSIONAL AUDIO EQUIPMENT User Manual & Installation
Experts in Chem-Feed and Water Treatment. How To Connect. Aquatrac Training. ProMinent Fluid Controls
How To Connect Aquatrac Training Applies to: Multiflex Browser Applies to: Multiflex Browser Trackster 3 Applies to: Multiflex Browser Trackster 3 Aegis Browser Applies to: Multiflex Browser Trackster
Cabling and Building Infrastructure for Technology
Cabling and Building Infrastructure for Technology by: Ernest J. Schirmer, Director Information Technology Infrastructure Design CUH2A Architecture Engineering Planning 211 Carnegie Center Princeton, NJ
8-Port 10/100Mbps 802.3af / 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch. FGSD-910P / FGSD-910HP User s Manual
8-Port 10/100Mbps 802.3af / 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch FGSD-910P / FGSD-910HP User s Manual Trademarks Copyright PLANET Technology Corp. 2014. Contents are subject to revision
CCTV System Troubleshooting Guide
Wouldn t be nice to start and finish a CCTV System Project without running into any problems before, during and after the installation is completed. Well, in this article we will try and explain why we
How to Determine the Right Fiber Optic Network Backup Switch For Your Application
How to Determine the Right Fiber Optic Network Backup Switch For Your Application Raymond B. Sepe, Sr. Electro Standards Laboratories 36 Western Industrial Drive Cranston, RI 02921 Telephone: 1-401-943-1164
Broadband 101: Installation and Testing
Broadband 101: Installation and Testing Fanny Mlinarsky Introduction Today the Internet is an information superhighway with bottlenecks at every exit. These congested exits call for the deployment of broadband
Cisco - Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications
Page 1 of 8 Ethernet 100BaseTX and 10BaseT Cables: Guidelines and Specifications Contents Introduction Prerequisites Requirements Components Used Conventions Which Cable Do I Need? Ethernet Cabling Guidelines
The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings. Focus on the IBDN System 4800LX from NORDX/CDT
The effect of temperature on the bandwidth of telecommunications cabling in commercial buildings Focus on the IBDN System 4800LX from NORDX/CDT Table of Contents Introduction... 3 Bandwidth and Information
DIVISION 26 - ELECTRICAL SECTION 26 05 20 CABLES FOR INSTRUMENTATION
DIVISION 26 - ELECTRICAL PART 1 - GENERAL 1.01 SUMMARY A. Section Includes 1. Instrumentation Cables 1.02 SUBMITTALS A. Submit in accordance with requirements of Section 01 33 00. B. Product Data: Submit
Making a DB to RJ45 adapter.
Making a DB to RJ45 adapter. DB9 to RJ45 adapters are often used in combination with a RS232 repeater for extending the distance of a serial RS232 link, but can be used for any adapter or converter purposes.
Fast Ethernet FX-TX Media Converter. User Manual RINGDALE
Fast Ethernet FX-TX Media Converter User Manual RINGDALE Introduction The Fast Ethernet FX-TX Media Converter Provides an ideal solution for extending the cable length of your network, or a way of interconnecting
Comtrol Cable User Guide
Comtrol Cable User Guide Trademark Notices Comtrol and DeviceMaster are trademarks of Comtrol Corporation. PortVision is a registered trademark of Comtrol Corporation. Microsoft and Windows are registered
The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT
The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error
Power over Ethernet (PoE)
Power over Ethernet (PoE) Power over Ethernet (PoE) sends direct current (DC) voltage and computer data over the same Ethernet cable, enabling a device to receive DC power and computer data simultaneously.
Características. Starligh SA 9 de julio 1595 Córdoba Argentina - 0351-4809210 / 4119600
Balun Activo - BALUN_ACT Características Single Channel Active Video Transmitter Full-motion color video signal up to 3900ft(1200m) via UTP cat5e/6 NTSC, PAL & SECAM video format compatible Real-time transmission
Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.
Commercial Building Telecommunications Cabling Standard Disclaimer This information is collected and composed by QUANG DUNG TECHNOLOGY from Cablingdb.com. All information is copyrighted by Cablingdb.com.
GORE Aerospace Cables
GORE Aerospace Cables For Data Transmission Reliable signal transmission in high-density, lightweight constructions Engineered for demanding aerospace environments, GORE Aerospace Cables are constructed