Design of heat exchangers



Similar documents
Heat exchangers are devices that facilitate the exchange of heat between

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

Heat Exchangers. Heat Exchanger Types. Heat Exchanger Types. Applied Heat Transfer Part Two. Topics of This chapter

Examples for Heat Exchanger Design

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Heat Exchangers. Plate-and-Frame COMPACT HEAT EXCHANGERS PART 1: heat exchangers. Use these design charts for preliminary sizing.

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

Sizing of triple concentric pipe heat exchanger

The Effect of Mass Flow Rate on the Enhanced Heat Transfer Charactristics in A Corrugated Plate Type Heat Exchanger

A Selection Guide for DTL Series Heat Exchangers

2.2. Basic Equations for Heat Exchanger Design

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Shell and Tube Heat Exchanger Design Software for Educational Applications*

Selecting TEMA Type Heat Exchangers

LESSON 1. HEAT EXCHANGERS

INTRODUCTION TO. Chapter 15

5.2. Vaporizers - Types and Usage

Fired Heater Design and Simulation

Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchanger

HEAT TRANSFER ANALYSIS IN A 3D SQUARE CHANNEL LAMINAR FLOW WITH USING BAFFLES 1 Vikram Bishnoi

FREESTUDY HEAT TRANSFER TUTORIAL 3 ADVANCED STUDIES

Answer, Key Homework 6 David McIntyre 1

Thermal Mass Availability for Cooling Data Centers during Power Shutdown

Learning Module 4 - Thermal Fluid Analysis Note: LM4 is still in progress. This version contains only 3 tutorials.

Energy Conservation: Heat Transfer Design Considerations Using Thermodynamic Principles

AIR CONDITIONING TECHNOLOGY

Thermodynamics - Example Problems Problems and Solutions

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

Chapter 8: Heat Exchangers

Type: Single Date: Homework: READ 12.8, Do CONCEPT Q. # (14) Do PROBLEMS (40, 52, 81) Ch. 12

NUMERICAL ANALYSIS OF THE EFFECTS OF WIND ON BUILDING STRUCTURES

International Journal of Latest Research in Science and Technology Volume 4, Issue 2: Page No , March-April 2015

A heat pipe heat recovery heat exchanger for a mini-drier

CFD STUDY OF TEMPERATURE AND SMOKE DISTRIBUTION IN A RAILWAY TUNNEL WITH NATURAL VENTILATION SYSTEM

OPTIMIZING THE CLEANING OF HEAT EXCHANGERS. Richard E. Putman Conco Consulting Corp.

Routinely surveying tower overhead vacuum systems can

Using Computational Fluid Dynamics (CFD) for improving cooling system efficiency for Data centers

Efficiency on a large scale CFB Steam Boilers

Shell and Tube Heat Exchanger

Thermal design of shell-and-tube

cmn_lecture.2 CAD OF DOUBLE PIPE HEAT EXCHANGERS

Mathematical Modelling and Design of an Advanced Once-Through Heat Recovery Steam Generator

TWO-DIMENSIONAL FINITE ELEMENT ANALYSIS OF FORCED CONVECTION FLOW AND HEAT TRANSFER IN A LAMINAR CHANNEL FLOW

STEAM TURBINE 1 CONTENT. Chapter Description Page. V. Steam Process in Steam Turbine 6. VI. Exhaust Steam Conditions, Extraction and Admission 7

Dynamic Process Modeling. Process Dynamics and Control

Heat Transfer by Free Convection

Heat Exchangers in Boilers

Introduction to Computational Fluid Dynamics (CFD) for Combustion. (801)

Dimensional analysis is a method for reducing the number and complexity of experimental variables that affect a given physical phenomena.

Module 1 : Conduction. Lecture 5 : 1D conduction example problems. 2D conduction

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

CFD SIMULATION OF SDHW STORAGE TANK WITH AND WITHOUT HEATER

DEVELOPMENT OF HIGH SPEED RESPONSE LAMINAR FLOW METER FOR AIR CONDITIONING

Define the notations you are using properly. Present your arguments in details. Good luck!

Test 5 Review questions. 1. As ice cools from 273 K to 263 K, the average kinetic energy of its molecules will

Differential Relations for Fluid Flow. Acceleration field of a fluid. The differential equation of mass conservation

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

SECTION 3: CLARIFICATION AND UTILITIES (1)

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

Experiment 1: Colligative Properties

The Second Law of Thermodynamics

Basics of Steam Generation

OPTIMIZATION OF DIAMETER RATIO FOR ALPHA-TYPE STIRLING ENGINES

DESIGN OF NATURAL VENTILATION WITH CFD CHAPTER SEVEN. Qingyan Chen. difficult to understand and model, even for simple

Natural Convection. Buoyancy force

Battery Thermal Management System Design Modeling

Corrugated Tubular Heat Exchangers

HEAT TRANSFER IM LECTURE HOURS PER WEEK THERMODYNAMICS - IM _1

HEAT TRANSFER ENHANCEMENT IN FIN AND TUBE HEAT EXCHANGER - A REVIEW

HEATX :- A Computer Program for Rating and Designing Shell and Tube Heat Exchangers.

Heat Transfer Prof. Dr. Ale Kumar Ghosal Department of Chemical Engineering Indian Institute of Technology, Guwahati

Initial Experiments of a Novel Liquid Desiccant Dehumidifier for Industrial and Comfort Air Conditioning Systems

. Address the following issues in your solution:

Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

Pipe Flow-Friction Factor Calculations with Excel

Theoretical and Numerical Analysis of Heat Transfer in Pipeline System

Heat-Pipe Heat Exchanger

Piping Hydraulic Line Design and Sizing Software KLM Technology Group

Sizing and Selection of Hot Water Generating Plant. Presentation by: Rob Larner & David Dutch

BorsodChem MCHZ, Czech Republic. 6,000 Nm 3 /h HTCR Topsøe Hydrogen Plant A Case Story: 18 Months from Engineering to Operation

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

Thermochemistry. r2 d:\files\courses\ \99heat&thermorans.doc. Ron Robertson

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

A MTR FUEL ELEMENT FLOW DISTRIBUTION MEASUREMENT PRELIMINARY RESULTS

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

HEAT TRANSFER AUGMENTATION THROUGH DIFFERENT PASSIVE INTENSIFIER METHODS

Energy Efficient Operations and Maintenance Strategies for Boilers

Transient Analysis of Integrated Shiraz Hybrid Solar Thermal Power Plant Iman Niknia 1, Mahmood Yaghoubi 1, 2

RESPONSE TIME INDEX OF SPRINKLERS

The final numerical answer given is correct but the math shown does not give that answer.

THE HUMIDITY/MOISTURE HANDBOOK

HEAT UNIT 1.1 KINETIC THEORY OF GASES Introduction Postulates of Kinetic Theory of Gases

Wood Fired Hot Tub Heat Exchanger Andrew Wallace With guidance from Woodie Flowers June 29, 2002

CHEMICAL ENGINEERING LABORATORY 3, CE 427 DRYING OF SOLIDS

We will try to get familiar with a heat pump, and try to determine its performance coefficient under different circumstances.

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Transcription:

Design of heat exchangers Exchanger Design Methodology The problem of heat exchanger design is complex and multidisciplinary. The major design considerations for a new heat exchanger include: process/design specifications, thermal and hydraulic design, mechanical design, manufacturing and cost considerations, and trade-offs and system-based optimization as shown in figure, with possible strong interactions among these considerations as indicated by double-sided arrows The thermal and hydraulic designs are mainly analytical and the structural design is to some extent. Most of the other major design considerations involve qualitative and experience-based judgments, tradeoffs, and compromises. Therefore, there is no unique solution to designing a heat exchanger for given process specifications.

Two most important heat exchanger design problems are the rating and sizing problems. Determination of heat transfer and pressure drop performance of either an existing exchanger or an already sized exchanger is referred to as the rating problem. The objective here is to verify vendor specifications or determine the performance at off-design conditions. The rating problem is also sometimes referred to as the performance problem. In contrast, the design of a new or existing-type exchanger is referred to as the sizing problem. In a broad sense, it means the determination of the exchanger construction type, flow arrangement, heat transfer surface geometries and materials, and the physical size of an exchanger to meet the specified heat transfer and pressure drops. However, from the viewpoint of quantitative thermal-hydraulic analysis, we will consider that the selection of the exchanger construction type, flow arrangement, and materials has already been made. Thus, in the sizing problem, we will determine here the physical size (length, width, height) and surface areas on each side of the exchanger. The sizing problem is also sometimes referred to as the design problem. The design of heat exchanger is complex task. There are many variables associated with the geometry (i.e., tubes, shell, baffles, front and rear end, and heads) and operating conditions including flow bypass and leakages in a heat exchanger. There are no systematic quantitative correlations available to take into account the effect of these variables on the exchanger heat transfer and pressure drop. As a result, the common practice is to presume the geometry of the exchanger for the determination of the heat duty and the exchanger size calculation. The design calculations can be also performed as a series of iterative rating calculations made on an assumed design and modified as a result of these calculations until a satisfactory design is achieved. Flue gas heat exchanger and boiler heating surfaces are mainly designed as serpentine tube bundles. The following is a step-by-step procedure for the "sizing" problem in which we will determine the exchanger dimensions. The key steps of the thermal design procedure for a serpentine tube heat exchanger are as follows: 1. From given parameters calculate unknown inlet or outlet temperatures and flow rates of fluids and heat transfer rate of heat exchanger using overall energy balance 2. Select a preliminary flow arrangement (i.e. based on the common industry practice). 3. Design preliminary geometry parameters of heat exchanger. The work includes selection of tube diameter, layout and pitch. 4. Choose fluid flow velocities. 5. Estimate the log-mean temperature difference. 6. Estimate an overall heat transfer coefficient using appropriate methods for heat transfer calculation for designed type of heating surface. 7. Estimate required heat transfer area. 8. Calculate length of tubes, the number of serpentines or passes, baffles etc. (depending on heat exchanger type). 9. Estimate outside dimensions of heat exchangers. 10. Calculate pressure drops for both fluids. 11. Repeat, if necessary, steps 3 to 9 with an estimated change in design until a final design is reached that meets specified requirements. This step-by-step procedure is consistent with overall design methodology and can be executed as a straightforward manual method or as part of a computer routine. Although the actual design has been frequently carried out using available sophisticated commercial software.

Overall energy balance For a modern heat exchanger the energy losses to the surrounding air can be neglected, as they are very small. Thus the heat energy given off by the hot fluid is equal to the heat energy absorbed by the cold fluid, i.e. an energy balance. Two energy conservation differential equations for an overall adiabatic two-fluid exchanger with any flow arrangement are dq = q"da = -C hdt h = +C cdt c [W] (1) Here dq is heat transfer rate from the hot to cold fluid across the surface area da; C h and C c are the heat capacity rates for the hot and cold fluids, and the +/- sign depends on whether dt c is increasing or decreasing with increasing da. The heat capacity rate is C i = m ic i [W/K] (2) where m i [kg/s] is mass flow rate and c i [Jkg -1 K -1 ] is specific heat of fluid i at constant pressure. The overall rate equation on a local basis is dq = q"da = U(T h - T c) locda = U TdA [W] (3) where U is the overall heat transfer coefficient. Integration of Eqs. 1 and 3 across the exchanger surface area results in overall energy conservation and rate equations as follows. q = C h(t h,i - T h,o) = C c(t c,o - T c,i) [W] (4) and q = UA T m [W] (5) Here T m is the true mean temperature difference dependent on the exchanger flow arrangement. The required heat transfer rate can be determined from known flow rate, heat capacity and temperature change for either the hot fluid or the cold fluid. Then either the flow rate of the other fluid for a specified temperature change, or the outlet temperature for known flow rate and inlet temperature can be calculated. Aim of overall energy balance is to determine all external parameters describing heat exchanger operation: mass flow rates m h, m c inlet temperatures T h,i, T c,i outlet temperatures T h,o, T c,o heat transfer rate Depending on given parameters solving of following tasks is possible:

Selection of flow arrangement Basic flow arrangements of two fluids in heat exchanger are counterflow, parallelflow, single-pass crossflow, multipass crossflow and various combinations. counterflow parallelflow multipass crosscounterflow multipass crossparallelflow single-pass crossflow combined multipass crossflow Preliminary geometrical design The work includes selection of tube diameter, layout and pitch. Choice depends on many conditions i.e. type of fluid, its velocity, pollution by particles and chemical impurities, design limitations etc. Two layouts of tubes in bundle are: inline staggered

Choice of fluid flow velocities Choice of fluid flow velocity according to common practice allows reasonable and compromise values of overall heat transfer coefficient and pressure drop already in the first approach to heat exchanger design. Recommended velocities of fluid flows are: water in tubes 0,3 1,0 m/s steam-water mixture in horizontal tubes 1,0 3 m/s steam in tubes up to 30 m/s gases in tubes 10 15 m/s air, clean flue gas cross tubes 8,0 15 m/s flue gas with particles cross tubes 5,0 10 m/s water cross tubes 0,2 0,8 m/s Velocity in tubes determines number of parallel tubes as follows. 4 m d w n t 2 Number of parallel tubes, their layout and pitch influences external dimensions of heat exchanger. The log-mean temperature difference The driving force for any heat transfer process is a temperature difference. For heat exchangers temperature difference between two fluids across the heating area is not constant. It depends on heat exchanger arrangement and value of C h and C c. Temperature distributions in a counterflow heat exchanger of single-phase fluids Temperature distributions in a parallelflow heat exchanger of single-phase fluids Evaluation of an average temperature difference is necessary for calculation of heat transfer rate. For cases with pure counter and parallel flow the temperature difference is best represented by the log mean temperature difference (LMTD or ΔT m ), defined in equation below. where: ΔT 2 = the larger temperature difference between the two fluid streams at either the entrance or the exit to the heat exchanger

ΔT 1 = the smaller temperature difference between the two fluid streams at either the entrance or the exit to the heat exchanger Use of log mean temperature difference for evaluation of heat transfer ration is valid on following conditions: 1. The heat exchanger is at a steady state. 2. Each fluid has a constant specific heat. 3. The overall heat transfer coefficient is constant. 4. There are no heat losses from the exchanger. 5. There is no longitudinal heat transfer within a given stream. 6. The flow is either parallel or counter. The assumptions are commonly satisfied in practice. It should be noted that an isothermal phase transition (boiling or condensing a pure component at constant pressure) corresponds to an infinite specific heat, which in turn satisfies the second assumption very well. Cross flow heat exchangers In case of cross flow heat exchanger, fluid temperature differences are illustrated as three-dimensional as shown in figure. t t A, t B = f(x,y) t B2 = f(y) t A2 = f(x) t A1 t B1 y In these heat exchangers, the temperature difference is not possible calculate by previous method, the correction factor is usually used where the log mean temperature difference is expressed as ΔT m = Ψ ΔT m, CF where Ψ is the correction factor and ΔT m, CF is the log mean temperature difference for a counter flow heat exchanger. Value of correction factor is usually determined from diagrams relating to crossflow heat exchanger arrangement. Example of one of such a diagram is shown in following figure. x

T1 R T 2 T2 P t h t, i c, i curve Tubular flue gas air preheater