General Specifications



Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

CompactLogix Power Supplies Specifications

3500/93 System Display

Technical Information

General Specifications

Digital input modules

PCS0100en Persy Control Services B.V. Netherlands

General Specifications

1756 ControlLogix Chassis Specifications

General Specifications

S-series SQ Controller

OZW30. Central Unit SYNERGYR

3500/22M Transient Data Interface

Scout 1U Rackmount Computer

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Electro-pneumatic control valves

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Temperature & Humidity SMS Alert Controller

Datex-Ohmeda Critical Care Monitor

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Voltage Regulator SPAU 341 C. Product Guide

NC-12 Modbus Application

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Foxboro Evo Process Automation System

DeltaV SISnet Repeater

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

HYDRUS ULTRASONIC METER

MCR1900 Media Converter 19-Slot Chassis

DC Electronic Loads 8500 series

Plug and Socket Devices CES 63 A Series 8579

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Product Information Sheet UH28CS-12kV Hi Pot Tester

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Rack mounted telephone- and leased line modem for industrial applications

StructureScan HD Module. Installation Guide ENGLISH

M-series MD Plus Controller

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

General Specifications

SYSTEM DESCRIPTION Termination Boards

S-series Mass Connection Solutions

3500/62 Process Variable Monitor

Three-phase monitoring relay CM-PFE

DCS Data and communication server

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Colour Video Monitors PVM-9045QM/9042QM/9040ME PVM-6041QM

FGM 160 ATEX EC type examination certificate

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Accessories SUNNY REMOTE CONTROL

Series Six Plus Programmable Controller

General Specifications

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

3DLevelScanner II TECHNICAL DATA SHEET

Electric Rotary Actuator - On/Off or programmable control actuator

NX safety stand-alone

R&S UMS12-OEM Monitoring System Modular monitoring system with open programming interface

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

MITSUBISHI ELECTRIC ANNOUNCES PHOTOVOLTAIC INVERTER FOR EUROPEAN MARKET

Electronic Control Devices The European Product Catalogue 2007

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

How To Sell A Talan

SecureSphere Appliances

Type testing

A good connection. International approvals.

Safety automation solutions

7 Lighting Technology

GSM ATT Modules Simply effective remote control

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

Disturbance Recoder SPCR 8C27. Product Guide

Technical Data. Dimensions

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

Safety technique. Emergency stop module BO 5988 safemaster

USER MANUAL V5.0 ST100

CompactRIO crio-9052

3500/25 Enhanced Keyphasor*Module

FIREDEX Conventional Fire Panels

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Remote Monitoring and REC 501 Control Unit Product Guide

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

DCS Input/Output Relay Card Series

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

10/100/1000 Base-T to Gigabit Fiber Media Converter

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Fujitsu PRIMERGY BX600 S3 Blade Server

HARTING mcon 1000 Introduction and features

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Mounting HP Desktop Mini Rack Mount Tray Kit HP Desktop Mini Security/Dual VESA Sleeve

Transcription:

General Specifications Models AFV30S, AFV30D Field Control Unit Duplexed Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable Type) GENERAL This GS covers the hardware specifications of the Field Control Unit (FCU) which is the core of the control function of the Field Control Station (FCS). Attention: These products are subject to the Export Administration Regulations (EAR) by the United States Department of Commerce, Bureau of Industry and Security (BIS). It is not possible to export or reexport these products to Iran, Cuba, North Korea, Syria, and Sudan. HARDWARE SPECIFICATIONS For the installation specifications and the environmental conditions common to the systems, refer to Integrated Production Control System CENTUM VP System Overview (Vnet/IP Edition) (GS 33K01A10-50E). Processor VR5532 (350 MHz) Main Memory Capacity 128 MB Memory Protection During Power Failure Battery Battery Back-up for Main Memory: Max. 72 hours Battery Recharge Time: Min. 48 hours FCU Status Contact Output 2 terminals (NC, C) Contact Points open during FCU failure Contact Rating: 30 V DC, max. 0.3 A Note: When option code /HKU is specified, a FCU fault contact is output from the House Keeping Unit (HKU). Communication Interface Vnet/IP Interface: For more details, refer to "Integrated Prodction Control Systrm CENTUM VP System Overview (Vnet/IP Edition)" (GS 33K01A10-50E) HKU Interface (Option) When option code /HKU is specified, a FCU fault contact is output from the HKU. Also, the environmental conditions of the cabinet connected via the HK bus and optical ESB bus can be monitored and the operating status of the HKU can be displayed on the HIS. System alarms can also be displayed. [19-inch Rack Mountable Type FCU] F01E.ai No. of s Connectable Max. 13/FCU The total number of s (ANB10 ) and Optical s (ANB11 ) that can be connected to FCU are 13 or less. The ER Bus Node Unit (ANR10 ) cannot be connected. The Control function for field control station (LFS1700) allows up to 3, and can be expanded as follows by adding the Node Expansion Package (LFS1750). LFS1750-V1: Max. 9/FCU LFS1750-V2: Max. 13/FCU To connect a node unit to the FCU, a Expansion License (option code: /NDEL) is required for the node unit. Module Configuration Power Supply Module (PW481 or PW482 or PW484): 2 modules for dual-redundant configuration Processor Module (CP461): 2 modules for dualredundant configuration I/O Module (*1): Max. 8 *1: Non-standard component. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5634 Fax.: 81-422-52-9802 Copyright Aug. 2011(YK) 5th Edition Apr. 1, 2013(YK)

Installation Restrictions To connect the (ANB10 ) or Optical (ANB11 ) to the FCU, install the Coupler Module (EC401 or EC402) in slots 7 and 8 of the FCU. For the dual-redundant configuration of the processor modules, EC401 or EC402 must be installed in both slot 7 and slot 8. In case has a single configuration, EC401 or EC402 must be installed in slot 7 and keep slot 8 empty. To install the optical ESB bus node unit and ESB bus node unit in a remote location, use the Optical ESB Bus Repeater Master Module (ANT401 or ANT411) to connect them with an optical fiber cable. To install the optical ESB bus repeater master module in the FCU, install a pair of modules in slots 1 to 6 in order from right to left according to the number of branches. In a single configuration, install the individual modules in slots 1, 3, and 5 in order from right to left. For details, see the Optical Repeater Module (GS 33K50F51-50E/GS 33K50F52-50E). For the limitations and precautions for installing I/O modules, see FIO System Overview (for Vnet/IP) (GS 33K50F10-50E). Power Supply Voltage: 100-120 V AC, Frequency: 50/60 Hz Voltage: 220-240 V AC, Frequency: 50/60 Hz Voltage: 24 V DC Specify with the Suffix Code. Power Consumption 100-120 V AC: 200 VA 220-240 V AC: 230 VA 24 V DC: 5.5 A Weight Approx. 7 kg (AFV30S) Approx. 8 kg (AFV30D) Mounting 19-inch Rack Mounting: Rack mount (M5x8 screws) Insulation bush (accessory) Connection Power Supply: M4 screw terminal connection Grounding: M4 screw terminal connection FCU Status Contact Output: M4 screw terminal connection Network: Connect UTP cable (CAT5e or better) to Layer 2 switch. Regulatory Compliance For the detailed information of following standards, see Integrated Production Control System CENTUM VP System Overview (for Vnet/IP) (GS 33K01A10-50E). Safety Standards [CSA] (for 100-120 V AC power supply) [CE Marking] EMC Conformity Standards [CE Marking] [C-Tick Marking] (for 220-240 V AC and 24 V DC power supply) [KC Marking] Standards for Hazardous Location Equipment [FM Non-Incendive] [Type n] (for 24 2 June 1, 2012-00

TM1 READY FUSE RL1 CN1 (PSU-L) TM2 100-120V AC CN2 (PSU-R) <<Contents>> <<Index>> 3 System Configuration This is a configuration example of an FCU and node units, and an ESB bus (including optical ESB bus) that connects them. Vnet/IP FCU: Field Control Unit ESB bus Optical cable Optical ESB bus I/O signal connection Figure System Configuration F01E.ai LIMITATIONS OF INSTALLATION AND NOTICES FOR INSTALLATION For installing I/O modules in AFV30S or AFV30D, the quantity and allocation are limited. Also, when installing a node unit to the dedicated cabinet, there are limitations of installation under the ambient operating temperature conditions. When modules with built-in barriers are installed in AFV30, an insulating partition kit (Part No. T9083ND) must be installed. For details, please refer to FIO System Overview (for Vnet/IP) (GS 33K50F10-50E) and Installation Guidance (TI 33K01J10-50E). Sep. 1, 2012-00

4 EXTERNAL DIMENSIONS Unit: mm 8.75 21.3 482.6 465.1 440 207 150.6 20.4 265.9 221.3 146 44.5 31.75 5.9 Hole for mounting on a 19-inch rack 8 holes for M5 screws When specifying option code /HKU F03.ai SOFTWARE REQUIREMENT For AFV30S and AFV30D, the Control Function for Field Control Station (LFS1700) is required. Specify this control function with the suffix code. The number of the connectable node units and the application capacity can be expanded if the Node Expansion Package (LFS1750) is purchased. For the specifications of LFS1700 and LFS1750, refer to GS 33K15C10-50E. REQUIREMENTS FOR USING SEM (Sequence of Events Manager) For using SEM, the hardware requires some conditions. For details, refer to "SEM Sequence of Events Manager (for Vnet/IP and FIO)" (GS 33K30D10-50E). STANDARD ACCESSORIES The FCU is delivered with the following standard accessories. Parts Names Parts Numbers Description Quantity Remarks Insulating bush S9049PM 8 Accessory Aug. 19, 2011-00

5 MODELS AND SUFFIX CODES Field Control Unit Description Model AFV30S Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable) Suffix Option -S Standard type 3 Vnet/IP, single power supply 4 Vnet/IP, dual-redundant power supply 1 Always 1 1 100-120 V AC power supply (*1) 2 220-240 V AC power supply (*1) 4 24 V DC power supply (*1) 5 Basic type with no explosion protection 6 With ISA Standard G3 option and no explosion protection E Basic type with explosion protection F With ISA Standard G3 option and explosion protection LFS1700 Control function for field control station 1 (for AFV30 /AFV40, Vnet/IP and FIO) <for CP461> /HKU With HKU interface (*2) /ATDOC Explosion Protection Manual (*3) Note: These products are subject to the Export Administration Regulations (EAR) by the United States Department of Commerce, Bureau of Industry and Security (BIS). It is not possible to export or reexport these products to Iran, Cuba, North Korea, Syria, and Sudan. *1: To meet the safety standards and EMC standards, the unit must be installed in a keyed metallic cabinet. *2: When used in combination with ACUKT, specify this option code /HKU. *3: Select the option code /ATDOC to follow the ATEX Directive for use in potentially explosive atmospheres. Duplexed Field Control Unit Description Model AFV30D Duplexed Field Control Unit (for Vnet/IP and FIO, 19-inch Rack Mountable) Suffix Option -S Standard type 4 Vnet/IP, dual-redundant power supply 1 Always 1 1 100-120 V AC power supply (*1) 2 220-240 V AC power supply (*1) 4 24 V DC power supply (*1) 5 Basic type with no explosion protection 6 With ISA Standard G3 option and no explosion protection E Basic type with explosion protection F With ISA Standard G3 option and explosion protection LFS1700 Control function for field control station 1 (for AFV30 /AFV40, Vnet/IP and FIO) <for CP461> /HKU With HKU interface (*2) /ATDOC Explosion Protection Manual (*3) Note: These products are subject to the Export Administration Regulations (EAR) by the United States Department of Commerce, Bureau of Industry and Security (BIS). It is not possible to export or reexport these products to Iran, Cuba, North Korea, Syria, and Sudan. *1: To meet the safety standards and EMC standards, the unit must be installed in a keyed metallic cabinet. *2: When used in combination with ACUKT, specify this option code /HKU. *3: Select the option code /ATDOC to follow the ATEX Directive for use in potentially explosive atmospheres. ORDERING INFORMATION Specify model and suffix codes. For selecting the right products for explosion protection, please refer to TI 33Q01J30-01E without fail. TRADEMARK CENTUM and Vnet/IP are registered trademarks of Yokogawa Electric Corporation. Other company and product names appearing in this document are trademarks or registered trademarks of their respective holders. Subject to change without notice. Apr. 1, 2013-00