SWIMMING POOL AIR-HANDLING UNITS KU-DB Series



Similar documents
Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

CE6500 Energy Recovery Ventilator

ECOCIAT. Domestic hot water heat recovery unit

Bring the fresh in. Dedicated Outside Air Systems

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

KONRAD. Hybrid Fancoil Series

CRAC Precision climate control units for data centres

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Lesson 36 Selection Of Air Conditioning Systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SustainE(Sustainable Energy)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Under sill units. Type FSL-B-ZAS

saving energy in comfort Factsheet Recair Enthalpy

Operation and Installation Manual. Max Series

Cool Design for Homes and Offices

RPV - RP - RA air handling units

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

- White Paper - Data Centre Cooling. Best Practice

Innovent LASER Packaged Fresh Air Conditioning Units

SWIMMING POOL HEAT PUMP

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Glossary of Heating, Ventilation and Air Conditioning Terms

How To Understand Evaporator

HEAVY DUTY STORAGE GAS

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

SECTION HEAT PUMPS


TWE+TTA TWE+TWA T.R.

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Heat Pumps for Swimming Pools

PLUG and PLAY VRV Connection

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

The compact unit series

Condensing unit type EPSILON-ECHOS LE Technical information manual

SECTION AIR CONDITIONING UNIT

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

HVAC Systems: Overview

marine/bespoke split applications

Chilled Water HVAC Systems

AIR CONDITIONING TECHNOLOGY

lindab we simplify construction Air Handling Units Product Overview

Installation, operation and maintenance manual TX 35A

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Technical data. Danfoss DHP-A

Why and How we Use Capacity Control

UDSA - UDSBD unit heater

Pool Dehumidification Basics

Element D Services Heating, Ventilating, and Air Conditioning

Combi Unit Genius. The energy efficient Building Service Centre

MAC-120HE-01 Air-Cooled Chiller

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Dehumidification Frequently Asked Questions

SECTION MORTUARY REFRIGERATORS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Weiss Mobile Air Conditioning Systems

Answers to Your Questions from the Webinar

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

york air-conditioning products Residential & VRF News 2015

NSN

Split units TH with hermetic compressors

How air conditioning works

ThermoSorb Desiccant Dryers

Chilled Water Precision Air Conditioner For Critical Application

Transformer oil cooler ALFA A02

Dehumidifier D 850E. - Instruction manual version 02

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Low Cost. Lower Energy Costs. Higher Efficiency.

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Characteristics of Evaporators

Cooking at the Speed of light!

SWIMMING POOL HEAT PUMP Owners Manual

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

HP switch LP switch Discharge thermo Comp. Surface thermo

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Climate chamber with illumination

COMMISSIONING OF HVAC SYSTEMS

CoolTeg Plus Chilled Water (CW) version: AC-TCW

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

HEATER, AIR CONDITIONING AND VENTILATION

Unico Inverter. Unique and efficient.

How To Control Humidity With A Humidifier

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

New Trends in the Field of Automobile Air Conditioning

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Research on the Air Conditioning Water Heater System

Transcription:

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima

2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series

proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t = +30 C ϕ = 54% r.v. 3 4 Technical specification page 5 Automatic controls and control box page 5 FRESH AIR 5 Dimensions page 6 EXHAUST AIR 6 Modes of operation page 7 Schematic presentation of swimming pool area air handling INTRODUCTION 1 Climatic conditions within the area of indoor swimming pools are highly demanding. Apart from the fulfilment of determined temperature requirements, a special problem of the swimming pool area lies in a high content of water vapour evaporating from the surface of the swimming pool water. Pursuant to VDI 2089 the condition of air maintained within the swimming pool area must be fit both for the visitors and the building structure. A high water vapour content results in a high relative humidity of air. As a consequence of differing partial pressures on the external and internal side of the wall, water vapour penetrates through the structure. Another reason for deterioration of the structure is the condensation of water vapour from the air on cold wall surfaces. Besides a high quality of building works free from heat bridges and the application of adequate materials, the swimming pool area must be conditioned in the manner that reduces the temperature and air humidity to the values prescribed. This is possible by means of standard units for saturated warm air exhaust and fresh dry air supply, which is accompanied by a considerable energy consumption despite the use of a recuperator. It is only the units containing a heat pump that will achieve maximum energy savings, because the heat pump evaporator makes it possible to use the latent heat of water vapour from the air too. The heat assumed, which was released at condensation of water vapour contained in the air, returns on the heat pump evaporator again to the system in the process of supply air heating that precedes the injection of air or heating of the swimming pool water. The air-handling units of the KU-DB series, equipped with a plate recuperator with an exhaust air heat utilization exceeding 60% and a heat pump complete with the accessories and controls, guarantee the achievement of microclimatic conditions fit for man and the building structure. The unit operating costs are returned several times through the reduction of the building maintenance costs. Due to various conditions resulting from a varying intensity of using the swimming pool, a varying condition of the outdoor air during the day and various seasons of the year the design of the air-handling unit enables five different modes of operation at minimum operating costs.

4 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series 2 FEATURES The compact design of air-handling units of the KU-DB series makes the transportation and installation very simple. It contains all elements required for an automatic operation and a control box mounted on the unit or detached. The casing is made of aluminium sections free from heat bridges and galvanized double steel plate lining stuffed with a 25mm thick thermal insulation, non-combustible according to DIN 4102 (A1 category material). For the additional protection the external and internal side of the unit are coated by a plastic layer. The design allows a simple handling and maintenance, including the replacement of components. On a special request the unit may be manufactured with a 50mm thick thermal insulation. The unit comprises a 85 mm high platform made of galvanized steel profiles and rubber washers to prevent transmission of vibrations from the unit to the building. SUPPLY AND EXHAUST AIR FAN Centrifugal fans containing blades bent backwards and protected by a special varnish are statically and dynamically balanced. The sizes selected ensure a high degree of efficiency and allow a carefree and quiet operation. They are placed on a common platform together with the electric motor and contain shock absorbers and a flexible connection to the casing for vibration damping purposes. The standard supply includes double-speed electric motors of a B3 form and IP54 protection based on a belt transmission to the fan (a regulating belt pulley facilitates a fine adjustment of the fan working point). On request the electric motors may be equipped with frequency converters. The fan units are equipped with internal lighting and an excess pressure protector for control of operation. AIR FILTER Easily replaceable G4 category bag filters are mounted on the supply and exhaust air side. The degree of filter contamination is checked by means of an excess pressure protector. DAMPERS The system of dampers allows the change of the mode of operation. They are made of counterflow-connected aluminium blades equipped with rubber seals. The automatic operation of dampers is servomotor-controlled. PLATE RECUPERATOR It is made of aluminium fins additionally protected by an epoxy layer. The efficiency exceeding 60% brings the exhaust air to the limit of saturation and the inclined position of the plate recuperator allows the drainage of the condensate produced into a stainless steel drain pan. The recuperator is protected against freezing. The unit is normally produced with a plate recuperator without a by-pass. On request it can contain a by-pass, which will eliminate negative effects of the recuperator in the transitional period (operation mode 4). HEAT PUMP A set showing uniform features consists of a condenser, an evaporator, a compressor and the accessories (thermal expansion valve, filter, solenoid valve, gasholder, suction pressure switch and high-pressure controller,...) connected, tested and ready for automatic operation. In case of larger units components are disassembled into modules for transportation purposes and the connecting is carried out on site by the manufacturer s service technicians. The evaporator and the condenser are made of copper tubes and aluminium fins and protected by an epoxy coating. The evaporator and the drip tube are placed into a stainless steel drain pan, with the condensate discharge going through a siphon on the service side. The internal lighting and inspection glass on the unit shell enable a constant control of the heat pump operation. WATER HEATER It is made of copper tubes and aluminium fins and also additionally protected by an epoxy coating against aggressive compounds to be found in the swimming pool water. Pipe connections are placed laterally and the scope of delivery includes an antifreeze thermostat and a three-way electric motor operated valve. The heat capacity of the exchanger is not designed to compensate for the heat transmission losses.

proklima 5 TECHNICAL SPECIFICATION 3 Description Unit Unit type KU...-DB 3 4 5 6 7 8 9 Nominal volume flow of air Dehumidification capacity (1) Dehumidification capacity (2) Dehumidification capacity (3) Mixture ratio fresh-return air in winter below +5 C Mixture ratio fresh-return air in summer External fresh/supply air pressure drop (4) External return/exhaust air pressure drop (4) Air supply fan electric motor rating Sound pressure level Lp(A) - supply (5) Air exhaust fan electric motor rating Sound pressure level Lp(A) - exhaust (5) Compressor rating Air-handling unit rating total Connection voltage Water heater capacity at tw=80/60 C Heater connection Water flow through heater Pressure drop at water side - heater Valve connection Pressure drop through valve Air-handling unit length Air-handling unit width Air-handling unit height Height of platform with rubber washers Air-handling unit total weight Greatest module length (for transportation) Greatest module width (for transportation) Greatest module height (for transportation) Maximum weight m 3 /h 3750 5800 8000 11000 15000 18500 22000 kg/h 11 17 24 33 45 56 66 kg/h 19 31 42 61 79 96 118 kg/h 24 37 51 70 95.4 118 140 % 0-30 % 0-100 Pa 300 350 400 Pa 300 350 kw 0.8/3.0 1.1/4.0 1.1/4.0 2.5/7.5 3.3/11 3.3/11 3.3/11 db 79 75 77 77 80 80 80 kw 0.8/3.0 0.8/3.0 1.1/4.0 1.7/5.5 2.5/7.5 3.3/11 3.3/11 db 75 73 75 74 78 78 80 kw 5.2 7.3 10.6 14.6 21.2 24.1 28.8 kw 11.2 14.3 18.6 27.6 39.7 46.1 50.8 V/f/Hz 400 / 3 / 50 kw 32 47 70 95 130 158 190 DN 25 25 32 32 40 50 50 m 3 /h 1.37 2 2.9 4 5.5 6.73 8.03 kpa 3.2 8.6 8.3 9.9 8.8 10.1 9.3 DN 20 25 25 32 40 40 50 kpa 4.8 6.2 8.6 11 7.4 7.2 7.1 mm 3850 4150 4800 5000 5900 6050 6500 mm 665 970 970 1275 1275 1580 1580 mm 1430 1430 2080 2080 2730 2730 3340 mm 110 120 kg 920 1280 1760 2110 2630 3080 3560 mm 2400 2650 2200 2200 2800 2800 3200 mm 665 970 970 1275 1275 1580 1580 mm 1540 1540 2190 2190 2850 2850 3460 kg 560 770 720 915 1150 1245 1525 (1) Applies to a standstill period and the ambient air features t = 30 C, j = 54% r.h. (2) Applies to the period of swimming pool operation in winter with a 30% share of fresh air. Fresh air features t = = 5 C, j = 85% r.h. (3) In conformity with VDI 2089. (4) External air pressure drops to be determined by the project engineer. The fan electric motor ratings are fixed on the basis of external pressures specified in the table. (5) Sound pressure level L p (A) at 250 Hz measured in the duct at a distance of 2 m from the fan. Parallel operation of two identical units (mirror design) provides double capacity. Features of an air-handling unit equipped with a plate recuperator with a by-pass (on request). Subject to technical alterations! AUTOMATIC CONTROLS AND CONTROL BOX 4 The DDC automatic controls used for the unit operation and control provide all air-handling unit functions: ambient temperature and air humidity control; supply and exhaust fan operation management; heat pump operation control; monitoring of pressure drop due to filter impurities; damper operation management; water heater operation control and antifreeze protection; possibility of connecting to the central control or building management system (BAS); modem connection for the purpose of remote control. The control box is completely wired and contains all components for operation management, protection, control and signalling or rather troubleshooting.

6 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series 4 DIMENSIONS B H 2H L L 1 L 2 h a b c e f KU 3-DB 665 715 1430 3850 1450 2400 110 335 600 650 322 322 KU 4-DB 970 715 1430 4150 1500 2650 110 335 905 650 361 361 B H 2H L L 1 L 2 L 3 h a b c e f KU 5-DB 970 1040 2080 4800 1650 2200 950 110 530 890 960 453 453 KU 6-DB 1275 1040 2080 5000 1850 2200 950 110 530 1195 960 569 569 KU 7-DB 1275 1365 2730 5900 1950 2800 1150 120 630 1175 1265 638 638 KU 8-DB 1275 1365 2730 6050 2100 2800 1150 120 630 1480 1265 715 715 KU 9-DB 1580 1670 3340 6500 2100 3200 1200 120 830 1480 1570 715 715 Other positions of connection orifices possible. For maintenance purposes a free space of B size is to be provided in front of the unit (on service side). If transportation or bringing into the building are impossible, the units are supplied disassembled and are reassembled on site. Subject to technical alterations!

proklima 7 MODES OF OPERATION 6 1 INITIAL OPERATION FOR RAPID HEATING OF SPACE IN WINTER The supply fan is activated and supplies the treated return air (100% recirculation) through open dampers across filters and the water heater. 2 OPERATION IN THE STANDSTILL MODE (no swimmers) Water vapour is removed from the saturated air by feeding a portion of the exhaust air through the plate recuperator to the heat pump evaporator. The air precooled in the recuperator (sensible heat removal) is evaporator-cooled down to the dew point, which is accompanied by the condensate separation. The cooled and dehumidified air passing the recuperator is preheated (by removing heat from the swimming pool area exhaust air) and afterwards mixed with a portion of the untreated air. The mixture is heated on the heat pump condenser and fed into the space by a supply fan. The energy consumed for the heat pump operation returns to the condenser in form of thermal energy. 3 OPERATION WHEN USING SWIMMING POOLS IN WINTER When using swimming pools in winter the evaporation of water from the swimming pool surface is intensified. The sanitary requirements are met by adding a portion of fresh air and the mixture of dehumidified return and fresh air raises the plate recuperator efficiency (removal of sensible and partly of latent heat of saturated air in the swimming pool area) which also contributes to the increase in the total dehumidification capacity. 4 OPERATION WHEN USING SWIMMING POOLS IN TRANSITIONAL PERIODS The mode of operation in transitional periods at medium and high temperatures allows the use of maximum fresh air volumes, with activation of heat pumps, if required. 5 OPERATION WHEN USING SWIMMING POOLS IN SUMMER In the summer period the heat pump is out of operation and the 100% fresh air is used.

Our partners and representatives: proklima Manufacture and installation of ventilation, air-conditioning and heating equipment Head: Talani 14, HR-10000 Zagreb, Croatia Office and Factory: Luje NaletiliÊa 10a, HR-10020 Zagreb, Croatia Phone: +385 1 / 6546-343 Fax: +385 1 / 6546-344 Email: proklima@proklima.hr Internet: www.proklima.hr PB-DB03-ENG