RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4



Similar documents
HORNET Remote Control Systems

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

Drayton Digistat +2RF/+3RF

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

OPERATING INSTRUCTIONS

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Radio Thermostat Clock Part Number: Installation & User Instructions. Suitable for all Ferroli Combination Boilers

Operating Instructions

Secure Keypads for access control

e-ask electronic Access Security Keyless-entry

Setup guide. point to point wall plate extenders

500r+ Installation and User Guide

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

CONTENTS QUICK SETUP & INSTALLATION USER MANUAL. SUPA8 Quick Setup & User Manual

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

TS510 & TS500. Installation & User Guide. Compatible Equipment

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

Mirror Mount Video Monitor/Recorder with Front and Rear View Night Cameras PLCMDVR5

IN-OUT Thermometer with Cable Free Sensor and Clock

DALI RC BASIC SO. Control unit Operating instructions

CSP Combined Series. Telephone Door Entry. with. Proximity Keyfob Access

EBDSPIR-PRM, EBDSPIR-PRM-IP

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

Installation & User Manual Radio Remote rev1.0.3

InnoMedia ESBC B. Quick Install Guide. 1

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

VARIO PROX CARD READER INSTALLATION MANUAL

The Black Box Push Button Control Box

LED Security Spotlight User Manual

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

FIRERAY 2000 Installation Guide

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

ACS-30-EU-EMDR-10-MOD

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

Product and functional description

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

PAC1 Door Access Controller

SIT Sports. Safety Tracking System Manual WRC 2015

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Telefon (+45) Telefax (+45) Installation and operating manual

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

ENERGY AWARE. Monitor User Guide

Power Socket (2 Gang)

Home Security Alarm System

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

DAB+ / FM Tuner Model: TU-201

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

PROXIMITY CARD READERS C-10, C-20, C60, C70

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Model Owner s Manual. Español - P. 19 Français - P. 39

InnoMedia ESBC B. Quick Install Guide. 1

Floodlight Range Installation Guide

Digital input modules

BL-DBK150A DUAL BATTERY 12v 150 AMP SMART SYSTEM

5W LED Energy Saver PIR Bulkhead

H203D 中文 GB Version 1

instabus KNX / EIB System System E F G H

RDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

WD-AMX Water Detection Controllers

ACTIVE 5 ENGINEERING MANUAL

Operating instructions IV / 2007

caravan mover user`s manual P1 Automatic P1 Manual Safety precautions

Tele Radio T70 Jaguar

INSTALLATION MANUAL. SAILOR 5080 AC Power Supply

How To Program An Autodialer

4.3-inch Back-Up Camera

MTS Power Products MIAMI FL ATS-22AG. Automatic Transfer Switch And Control PLC Operator s Manual

CR9986 ROBERTS. Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use

MIC-WKT and MIC-WKT-IR

Control Box Wiring For PRSstandard Tool

HM-W536 Install Guide

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

BUSINESS. Elektronisches Türschloss. Installation and User Manual. Ingeniously safe. Ingeniously simple.

Users Guide to Keypad Functions

Digital Keypad Use s Manual

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Pocket DAB & FM Radio with Speaker

FPV MONITOR. User Manual

User s Information Guide R1A

SELECTION, APPLICATION AND MAINTENANCE

Installer Guide smart connect

Installation and operating instructions: Radio dimmer Type: DALI DM ADVANCED LI

Installation & Maintenance Instructions Joystick- single Joystick - double Touch panel Wireless remote control

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

Transmitter Actuator 230V wave UP 560. Operation

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Tele Radio Tiger BASIC INSTRUCTIONS FOR 10-BUTTONS TRANSMITTER

GERONIMO ANALOGUE HEAVY DUTY TELEPHONE

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Transcription:

RUST ELECTRONICS LTD Remote Switching Unit RCU-O4

MAINS REMOTE SWITCHING UNIT RCU-O4 The RCU-O4 is a radio remote controlled switching unit that will allow the remote operation of any appropriate electrical appliance that is required. The unit is constructed to industrial/commercial standards, giving the convenience of remote operation and in most cases the reduction in installation costs will exceed the cost of switching unit. The output of the unit is in the form of a relay change over contact rated at 8 amps 240V AC. On the reception of a valid signal the output can be programmed to be momentary, toggled or timed using the internal dip switches. The remote control is achieved by using an encoded UHF radio signal produced by a key fob transmitter with a super-hetrodyne receiver validating the transmitted code and activating the output accordingly. The receiver unit is IP65 rated (see INSTALLATION) allowing external positioning, with a self- contained power supply. The electrical appliance can be operated remotely be simply connecting to a mains supply via the RCU-O4 remote receiver unit. INSTALLATION First remove the lid and carefully retain the 4 lid screws. The DIP switches should be positioned in line with the table (overleaf), in order to establish the correct output control (Latched, momentary or timed). The receiver unit must be securely mounted, using the mounting holes provided, vertically with the aerial pointing upwards. Avoid positioning in close proximity to electronic equipment as interference from such equipment in certain circumstances could reduce the operational range. The wiring must be passed through the sealing gland, and connected appropriately (see diagram). Ensure that the supply to the unit is appropriately fused and if there is any doubt whatsoever regarding the electrical installation consult a competent qualified electrician. The cables must be clamped securely by tightening the sealing gland using a 19mm spanner ensuring that an adequate seal is formed against the outer sleeving of the cables (IP65 weather proof). All connections to the unit must made via the screw blocks provided. Ensure that there are no loose strands of wire present and that all connections are secure. If the load requires an earth, this MUST be provided, the comm block can be used to connect the incoming earth to corresponding earth on the load. Refer to 'Wiring diagram' for connection details. See 'Typical application' of a load connected to a mains supply. Prior to attaching the lid, check the integrity of the sealing gasket, using all 4 screws provided, tighten evenly until a weatherproof seal can be established. Before applying power ensure that the installation is both complete and safe. After the power is applied allow approximately 5 seconds for the electronics to stabilise. Activation of the remote transmitter will activate the receiver output, provided that it is within range. 2

CODING RADIO KEYS INTO UNIT Normally the unit is supplied with 1 dual button radio key coded into the unit. In this situation, when the unit is first powered the unit will enter AutoCoding (see below), after a key has been added or ten seconds have elapsed the LED will illuminate green, indicating that power is applied to the unit and has been pre-programmed to respond to at least one radio key. If the LED is red this indicates that the unit has no radio keys programmed. The unit is capable of responding to 9 radio keys of differing codes Programming 1. Press and release the function button (see diagram), the LED will extinguish for a brief period, followed by a 10 second coding period. During this period the LED will flash green, the number of times the LED flashes correspond to the number of radio keys that are coded into the unit. (If the LED does not flash then no radio keys are programmed). 2. Press a button on the radio key that is required to be coded into the unit, the LED will flash yellow briefly to confirm that the unit has accepted the radio key. 3. The LED will illuminate green to show that normal operation has resumed, and the unit will respond to the newly coded key. If the unit does not respond to the key then this will probably due to the 10 seconds allowed for coding having elapsed before the key fob button has been pressed (in this case go back to step 1) or the unit already has the maximum 9 radio keys programmed. Auto Coding In some applications it is inconvenient to access the coding button. In this instant it is possible to add radio keys by following the procedure below: 1. Disconnect the power supply. 2. Re-connect the supply and immediately press the corresponding button on the radio key that you require to be added within range of the receiver. The unit will learn and store the code from the radio key and regard the code as valid. NB. The unit will not 'learn' the radio key code if more than ten seconds have elapsed after applying power before the radio key button is pressed or if the unit has the maximum number of keys already stored. If the unit receives a code that is already programmed the unit will leave ' Auto-coding' and operate normally. It not possible to delete keys without access to the 'coding button' Deletion of radio keys To delete the radio keys programmed into the unit, press the function button for 10 seconds, the LED will illuminate yellow to confirm that the radio keys have been erased. Release the function button, the LED will go red showing that receiver unit is blank and is NOT programmed to accept radio keys. To re-enter radio keys see "PROGRAMMING" section above Output Set-up NOTE: As viewed from the front with the aerial at the top, the dip switches are in I block of 4. These are numbered from RIGHT to LEFT with the OFF position UPWARDS and the ON position DOWNWARDS DESIRED OUTPUT SINGLE BUTTON CONTROL SWITCH POSITION ACTIVATION MODE 4 3 2 1 MOMENTARY PROGRAMMED BUTTON OFF OFF OFF OFF 10 SECS TIMED PROGRAMMED BUTTON OFF OFF OFF ON 25 SECS TIMED PROGRAMMED BUTTON OFF OFF ON OFF 1 MIN TIMED PROGRAMMED BUTTON OFF OFF ON ON 5 MINS TIMED PROGRAMMED BUTTON OFF ON OFF OFF 20 MINS TIMED PROGRAMMED BUTTON OFF ON OFF ON 1 HOUR TIMED PROGRAMMED BUTTON OFF ON ON OFF ALTERNATE PROGRAMMED BUTTON OFF ON ON ON DESIRED OUTPUT SINGLE BUTTON CONTROL SWITCH POSITION ACTIVATION MODE 4 3 2 1 10 SECS TIMED BUTTON 1 SETS BUTTON 2 OFF ON OFF OFF OFF 25 SECS TIMED BUTTON 1 SETS BUTTON 2 OFF ON OFF OFF ON 1 MIN TIMED BUTTON 1 SETS BUTTON 2 OFF ON OFF ON OFF 5 MINS TIMED BUTTON 1 SETS BUTTON 2 OFF ON OFF ON ON 20 MINS TIMED BUTTON 1 SETS BUTTON 2 OFF ON ON OFF OFF 1 HOUR TIMED BUTTON 1 SETS BUTTON 2 OFF ON ON OFF ON 2 HOURS TIMED BUTTON 1 SETS BUTTON 2 OFF ON ON ON OFF INDEFINITE BUTTON 1 SETS BUTTON 2 OFF ON ON ON ON 3

WIRING DIAGRAM TYPICAL APPLICATION 4

SPECIFICATION Standard system comprises of: - 1 Receiver unit 1 Transmitter (Radio key) Pre-Coded Receiver Switching Unit SUPPLY 220-240 V AC 50/60Hz (Mains) RADIO FREQUENCY 433.92 MHz AM OPERATING TEMP -20 C to + 70 C RELAY 8A @ 240V AC CONNECTION SCREW TERMINALS IP RATING IP65 (WEATHER PROOF) DIMENSIONS H 115mm, W 65mm, D 40mm (Excluding 155mm aerial and gland) Transmitter RF OUTPUT SUPPLY CODE LICENCE DIMEMSIONS 433.92 MHz AM 12V Battery 24 BIT WT MPT 1340 LICENCE EXEMPT H 57mm, W 36mm, D 15mm As with all radio frequency based equipment, it is possible that external interference and environmental conditions can significantly effect the performance, therefore it is essential that this product is not used where failure of operation could be considered dangerous or result in damage or loss to property. In the interest of continued development, Rust Electronics Ltd reserve the right to alter the specification of this product without prior notice. 5