www.siemens.com/energy/uhvdc The Bulk Way UHV DC the new dimension of efficiency in HVDC transmission Answers for energy.



Similar documents
IEC/CIGRE UHV Symposium Beijing KVDC: EXTERNAL INSULATION, INSULATION COORDINATION, TEST LEVELS

The power to make power happen. Intelligent, digitally managed power transmission and distribution. Siemens Energy Management

Brochure Introducing HVDC

Transmission and distribution service level agreements

HVDC 2000 a new generation of high-voltage DC converter stations

A full range of monitoring solutions for surge arresters Answers for energy.

Monitoring, diagnostics, and cable services

Engineering innovation

FACTS. Solutions to optimise network performance GRID

Summary of Electric Transmission Assessment Report

The stable way. Synchronous condenser solutions. siemens.com/energy/facts

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Siemens ENEAS solutions for substation automation and protection

Converter Stations for 800 kv HVDC U Åström, and V. Lescale

Electrical Considerations for HVDC Transmission Lines. Joe Mooney, PE

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

2012 San Francisco Colloquium

Project description. Power Electronics for Reliable and Energy efficient Renewable Energy Systems

Totally Integrated Power SIESTORAGE. The modular energy storage system for a reliable power supply.

HVDC-VSC: transmission technology of the future

Wide Area Monitoring Current Continental Europe TSOs Applications Overview

HVDC Technology for Large Scale Offshore Wind Connections

2012 San Francisco Colloquium

ABB PSPS Erich Steinmann; Generator control-2013

Monitoring and diagnostics

Siemens Fusesaver. Highest availability and cost savings for your MV distribution network.

DC Traction Power Supply. Powerful, efficient and safe. siemens.com/mobility

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

factsheet High Voltage Direct Current Electricity technical information

POWER TRANSMISSION FROM OFFSHORE WIND FARMS

factsheet High Voltage Direct Current electricity technical information

A favorable investment in solar power

Hybrid Power Considerations for Today s Telecommunications

Intelligent power superhighways

Three Gorges - Changzhou HVDC : Ready to Bring Bulk Power to East

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

Power network telecommunication

The SGT5-8000H proven in commercial operation

Smarten up your last mile

DC TRANSMISSION BASED ON VOLTAGE SOURCE CONVERTERS

HVDC Light, a tool for electric power transmission to distant loads

The evolving world of power Opportunities and challenges

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

PSS E. High-Performance Transmission Planning Application for the Power Industry. Answers for energy.

Siemens Steam Turbine-Generator SST-5000 Series. for combined cycle and subcritical steam applications. Answers for energy.

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Power Transmission and Distribution. Shunt reactors for medium and highvoltage. From development to use

Magnus Callavik, ABB Power Systems, HVDC, Västerås, Sweden Phone: +46(0)

Cable Solutions for Servo and Variable Frequency Drives (VFD)

Technical Information POWER PLANT CONTROLLER

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Transmissão em Corrente Contínua

Offshore Platform Powered With New Electrical Motor Drive System

Permissible ambient temperature Operation Storage, transport

Power System review W I L L I A M V. T O R R E A P R I L 1 0,

A macro-economic viewpoint. What is the real cost of offshore wind? siemens.com / wind

Electric Power Systems An Overview. Y. Baghzouz Professor of Electrical Engineering University of Nevada, Las Vegas

CO-ORDINATION OF PARALLEL AC-DC SYSTEMS FOR OPTIMUM PERFORMANCE

System Protection Schemes in Eastern Denmark

Capacitor Voltage Transformer. Answers for energy.

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

ABB s Disconnecting Circuit Breakers Higher substation availability and lower environmental impact

DS1 Diode-based transient-free capacitor switch

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

B Konti-Skan 1 HVDC Pole Replacement

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

Transformers. Special transformers Reactors products

How do you design maximum data security?

Asset Management Plans

Table of Contents. TransformerIQ FAQs 1

Distribution Voltage Regulators

Topics. HVDC Fundamentals

Extend and optimize the life of your plant the modular Life Cycle Service portfolio

Nuclear Power Plant Electrical Power Supply System Requirements

Mechanical and electrical rebuilding of a turbine generator for phase-shift operation

PSS SINCAL efficient planning software for electricity and pipe networks. Siemens PTI Software Solutions. Answers for energy.

Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a

EMI in Electric Vehicles

Voltage Source HVDC Overview Mike Barnes Tony Beddard

INTRODUCTION TO HARMONIC ASSESSMENT IN POWER SYSTEMS

IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution

Unified requirements for systems with voltages above 1 kv up to 15 kv

Air Bio Control (ABC) Efficient and reliable control of air-supply systems. Answers for energy.

Tank Terminals Proven Solutions for Liquid Bulk Storage and Distribution Terminals

Changing locations every day. Can service be as mobile as a locomotive?

Smart solutions for fleets of all types & sizes of power generation. Marcus König, E F IE SGS / September 2013

Siemens AG Power Transmission and Distribution Medium Voltage Division Mozartstr. 31c Erlangen Germany.

Treasure Valley Electric Plan - Community Advisory Committee

Siemens D3 platform 3.0-MW, 3.2-MW, 3.3-MW, and 3.4-MW direct drive turbines. Reduced complexity, increased profitability. siemens.

COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS

HVDC. A firewall against disturbances in high-voltage grids. Lennart Carlsson

HySTAT HYDROGEN GENERATORS

Siemens Hybrid Power Solutions. Cost and emission reduction by integrating renewables into diesel plants

EssPro Energy Storage Grid Substation The power to control energy

CYBER PHYSICAL IIS

Study to Determine the Limit of Integrating Intermittent Renewable (wind and solar) Resources onto Pakistan's National Grid

V MW. Your best option for low cost energy production at low and medium wind sites. Federico Gonzalez Vives. Director Technology.

SHE Transmission. 2015_10_30 Transmission Losses Strategy Rev 2.0 October 2015

DS 600. A contact free flux gate based current measurement sensor 600A rms

Transcription:

www.siemens.com/energy/uhvdc The Bulk Way UHV DC the new dimension of efficiency in HVDC transmission Answers for energy.

Shape up for the future of power transmission Siemens UHV DC helps meet the steadily rising energy demands Throughout the world, the demand for power keeps growing at a scale and speed never imagined by past generations. For various reasons we also witness a strong push for renewable energy sources (RES), with power generation becoming increasingly distributed and a growing number of generation facilities located far away from load centers. At the same time, demanding economic objectives as well as obligations to reduce greenhouse gases have to be met. To meet all these demands precisely, Siemens has taken great efforts to overcome the existing limitations in the technology available for high-voltage direct current (HVDC) power transmission. Thanks to Siemens Ultra HVDC (UHV DC), long-distance power transmission at a voltage level of 800 kv - providing power capacities of up to seven gigawatts and more - has now become technically as well as economically feasible for the first time ever. Both poles of the first 800 kv UHV DC system, ordered by the China Southern Power Grid Co. in Guangzhou, are in commercial operation since June 2010. Pole one already started operation in December 2009. 2

Reap more with less effort Siemens UHV DC enables low-loss transmission of more than seven GW with a single bipolar line Siemens UHV DC is a newly developed system that provides the key to increased performance and robustness of the transmission grid, to keeping pace with the steadily growing energy demand, and to a highly economical way of CO2 emission reduction: single bipole power transmission capacity of more than seven GW at a voltage of ± 800 kv 60 percent reduction in transmission losses and CO2 emissions with UHV DC compared with standard ± 500 kv HVDC significantly smaller footprint and lower OHL costs compared with 800 kv AC solutions ideally suited for bulk power transmission over very long distances of 2,000 kilometers and more for infrastructure upratings capable of interconnecting large grids and stabilizing the surrounding AC systems advanced high-speed control system with Win TDC 3

Global prospects of UHV DC long-distance bulk power transmission many options to properly manage the rapidly growing demand for power UHV DC disconnector From Smart Grid to Super Grid Master tomorrow s challenges today Siemens UHV DC will be the bulk power energy highway and security backbone of the power grids of the future In view of the rapidly growing demand for power, it is clearly evident that the power markets will undergo enormous changes in the years to come. Many existing AC transmission systems are about to reach their capacity limits, and new transmission technologies are required for bulk power point-to-point long-distance transmission from generation to energy-hungry load centers, which are growing at breathtaking speed. In many countries, there will be a need for bulk power transmission corridors able to handle up to 60 GW of electric power. For various reasons, however, conventional AC transmission has proven unfeasible for this task. Here, Siemens ultra-high-voltage direct current (UHV DC) power transmission technology is thrust into the spotlight. The next level of HVDC technology, Siemens UHV DC, is characterized by its innovative 800 kv voltage level, its transmission capacity of up to 7,200 MW, and a substantial loss reduction. Thanks to thorough R&D efforts, Siemens is able to produce the entire range of componentsrequired for 800 kv DC power transmission and supply complete UHV DC systems from a single source. Benefit from innovation and expertise Siemens offers single-source supply for all UHV DC components and services UHV DC converter station A converter station links the DC transmission line at each end to the AC grids. It consists of a number of components that have reached a high degree of maturity. However, for UHV DC application, innovative solutions have been implemented to fully meet the extended requirements for ultra-high- voltage bulk power transmission. UHV DC converter transformer The converter transformers connect each pole of the UHV DC converter to the AC grid in an economical way. With UHV DC, transformers show very impressive dimensions, especially their bushings. Local transportation restrictions and converter configuration determine their type and size; for example, for the world s first UHV DC project Yunnan- Guang in China, a total of 48 transformers (plus eight spare units) had to be transported to the site. UHV DC converter A UHV DC converter performs the AC to DC conversion and vice versa. It consists of a number of thyristor modules that are connected in twelve-pulse groups. In the figure, a view of the new six-inch thyristor (8 kv, 4.5 ka) and the thyristor valve tower is shown. 4

UHV DC wall bushing and bypass switch 800 kv valve hall UHV DC voltage divider The UHV DC voltage divider from Siemens provides the DC-voltage measuring signal to the UHV DC control system. It is based on technology used in high-voltage test fields all over the world. The high accuracy of the divider is linear for almost the whole operating voltage range and above and extends over a large ambient temperature range. The challenge of developing an UHV DC voltage divider was to cope with the high internal and external dielectric stress, which is reflected in the dimension of the end-to-end composite insulator and the huge corona shield. UHV DC bypass switch and bypass disconnectors Both the UHV DC bypass switch and disconnector provide an option for more flexibility of the whole transmission scheme. For example, for a bipolar 800 kv DC transmission, two 400 kv converters at each pole are connected in series, and each one can be bypassed without interruption of the DC current whenever required. The assigned DC line is then operated at a reduced voltage level of 400 kv, and the redundancy of the transmission system is increased. UHV DC disconnectors The UHV DC disconnectors have to provide a safe isolation of all equipment in case of system shut-down, including during maintenance. The mechanical layout shows these requirements in an impressive way. Examples of the impressive testings of the UHV DC disconnectors are also highlighted in the figure. UHV DC surge arrester Insulation coordination of the protection levels of the UHV DC system determines the reliability of the whole transmission scheme. Surge arresters are the key elements for system security, for example, in case of line faults caused by lightning strikes, which are a typical and unavoidable natural phenomenon. Additional UHV DC main equipment UHV DC wall bushing: as impressive as the transformer bushings due to its extended dimensions for the required insulation levels UHV DC smoothing reactors: current-sourced converters use a reactor as a smoothing element for the DC current hybrid optical UHV DC measuring system: ohmic shunt for measuring UHV DC current on high-voltage potential transmitted to ground via fiber optics UHV DC PLC capacitor: used to prevent high-frequency noise from entering the DC overhead line, and provides a connection path for the DC line-fault locator signal UHV DC post insulators: different technologies on the market, all using silicone housings, provide hydrophobic behavior on the surface of the insulators, which greatly reduces the risk of flashovers due to pollution 5

UHV DC disconnector - test assembly UHV DC voltage divider System design and station layout Siemens system design expertise is based on more than 30 years of building HVDC transmission systems. Just as Siemens products improve from year to year, the company s system design experts push the limits of design to create ever-larger HVDC transmission systems. Siemens has the knowledge at highest expert level and provides system design, station layout, and insulation coordination, including the design of arresters and flash and clearance-distance calculations. Its expertise also includes AC and DC filter design, AC and DC protection coordination, harmonic calculations, loss calculations, radio interference and noise calculations, reactive power management, frequency and voltage control, power oscillation damping, and system interaction studies, including subsynchronous resonances, to name just a few. Both system design and component development evolve hand in hand, creating a constant development process that has always been driven by the goal of obtaining the maximum transmission capacity from an HVDC system of over 7,000 MW. Siemens system design experts contribute to achieving the perfect solution for their customers in each project, in close cooperation with them from the initial idea through the preliminary and final design, project execution, commissioning, and operation. And it doesn t stop there. Transmission systems grow as power demand changes. Siemens is the number one partner of choice when such changes call for a transmission system to be upgraded or modernized. Siemens is on hand to identify the most efficient and economic solution to maximize its customer s benefit and profit. Line arrester special challenges Development of an arrester housing for upright installation for maximum top deflection at specified seismic requirements and wind loads. Tests at the HSP Hochspannungsgeräte GmbH in Cologne: Lightning impulse voltage Switching impulse voltage in rain DC Voltage RIV test at DC maximum value 2,400 kv 1,770 kv 865 kv DC 1,040 kv 6

UHV DC converter transformer UHV DC surge arrester UHV DC valve tower 4 5 6

DC wall bushing test lab System testing and commissioning Siemens high quality assurance standards are fulfilled by intensive functional performance testing. Entire control and protection systems are connected to state-of-the-art digital real-time simulators (RTDS). All standard and customer-specific functions of the HVDC are verified in numerous transient and steady-state testing procedures. Physical limitations associated with carrying out on-site tests are a thing of the past, thanks to real-time simulator test facilities. The use of real-time simulators allows testing of all real system fault conditions in AC and DC that could possibly occur. Finally, the on-site commissioning concludes the testing program and perfects the system to guarantee fail-safe operation at highest availability. Capacitor-controlled wall bushing Technical data: Rated voltage Operating voltage AC Test voltage DC Test voltage Creepage path outdoor Creepage path indoor Rated current Weight 816 kv DC 800 kv DC 1,100 kv 1,455 kv DC 42,500 mm 26,630 mm 3,700 A DC 5,600 kg 8

DC/AC yard filters and reactive power compensation For ultra-high DC voltages of 800 kv, external insulation of the equipment is a vital issue. In the past, HVDC was limited to maximum voltage levels of 500 kv to 600 kv. Today, in order to enable bipolar power ratings of 7,000 MW and higher, the operating DC voltage levels of all equipment has been increased to 800 kv. The impact of this increased steady-state and transient voltage on entire UHV DC stations had to be carefully investigated. To do this, the adequacy of existing technologies was evaluated and manufacturing capabilities were taken into account. The challenges for all of the DC components were huge: Furthermore, mechanical requirements refer not only to operational forces but also to seismic conditions and wind loads anticipated in the areas where the AC and DC stations are located. By nature, ultra-high-voltage AC and DC equipment and suspension structure requirements are expected to be much higher than the requirements for existing voltage equipment. For this reason, both the electrical properties and mechanical stresses required careful consideration during equipment design. proper internal design of the equipment safe external insulation of the equipment housings adequate margin with respect to mechanical stresses, including seismic forces finding ways to transport equipment of these dimensions and weights 9

Operation, maintenance, and contracting UHV DC helps prevent bottlenecks and overloads in power grids through systematic power-flow control. As a result, the operation of UHV DC systems is basically similar to or even easier than the operation of a large power plant, with one important exception: the dynamic performance of the DC system is much more powerful than that of a standard power plant. This means that the DC transmission offers more features for dynamic system support through the injection of reserve capacity, based on its short-term and permanent overload capacities. That can help enormously in the event of emergencies like system faults or outages. The additional function of any DC system that is decisive for system security is an automatic firewall. This firewall function can prevent the spread of an AC disturbance within the system at all times. As soon as the disturbance has been cleared, power transmission can be resumed immediately at a predefined ramping speed. In addition, the maintenance of UHV DC equipment and systems is much less complex than that of a large power plant. The customer s own experts are trained intensively in system component technology and in relevant maintenance procedures, usually in two-year cycles. Along with test routines for system control, the training encompasses protection for the DC components and the DC line, the converter transformers, AC busbars, and AC feeder protection. It also includes the associated AC and DC measuring circuits together with the HVDC converter, the valve cooling, the converter transformer, and the DC and AC filter components. Within its contracting framework, Siemens also offers complete maintenance contracts where necessary, including a 24-hour round-the-clock emergency service. As part of Siemens service portfolio, total system operation responsibility is also available on contract, and is carried out by Siemens appointed specialists. 10

AC DC AC DC 735 kv 800 kv 6.7 % Losses per 1,000 km line 3.5 % 800 kv 800 kv 100 m 41 m 41 m 40 m Transmission capacity 40.5 m 40 m 3 GW 6.4 GW The advantage of UHV DC: it yields enormous transmission capacities and at the same time keeps losses to a minimum Thanks to transmission with a single bipolar line, the footprint of an UHV DC transmission line is significantly smaller than the footprint of a double-circuit AC transmission system with the same redundancy Increase the capacity and efficiency of your network Siemens UHV DC compels with an outstanding cost-benefit ratio in every respect One of the biggest and most untapped savings opportunities lies in advancing energy efficiency. That s exactly what makes UHV DC the option of choice for long-distance bulk power transmission. Generally speaking, with the innovative UHV DC transmission voltage of 800 kv, transmission losses are typically reduced by 60 percent in comparison with conventional 500 kv DC transmission. This means that UHV DC is ideally suited for the bulk power energy highways of the future Super Grid. That s why Siemens has made every effort to enter this new dimension of innovative ultra-high-voltage and bulk power transmission. With 800 kv UHV DC technology, both right-of-way requirements and transmission losses can be reduced significantly. It bears mentioning that for a n-1 redundancy criterion, bipolar DC transmission is equivalent to a double-circuit AC system, which means huge right-of-way savings on the DC system. Of course, Siemens UHV DC also fulfills its environmental responsibilities. The Yunnang-Guangdong project is the world s first 800 kv UHV DC system, transmitting large amounts of clean hydro power from western China to the load centers near Hong Kong since 2010 - and it prevents 33 million tons of CO2 emissions each year.* This multitude of economic and environmental benefits makes Siemens UHV DC ideally suited for the immediate and efficient enhancement of transmission infrastructures wherever required. Win TDC Siemens Win TDC is a state-of-the-art industrial standard control system for drives and many other applications, including HVDC and FACTS. Equipped with ultra-fast 64-bit RISC processors, flexible interfaces, and a specially designed HVDC trigger set, Win TDC is the ideal solution for UHV DC control and protection. * Compared to local power supply, based on an average energy mix 11

Published by and copyright 2011: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Sector Power Transmission Division Power Transmission Solutions Freyeslebenstrasse 1 91058 Erlangen, Germany For more information, please contact our Customer Support Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: support.energy@siemens.com Power Transmission Division Power Transmission Solutions Order No. E50001-G610-A101-V2-4A00 Printed in Germany Dispo 300003 fb 3986 471561 WS 0711 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.