Applications. Architectural



Similar documents
Rated Lumen [lm] Nominal. Volts [V] [lm]

Kolorlux. GE Lighting DATA SHEET

Multi-Vapor Metal Halide Lamps

ConstantColor CMH MR16

GE ConstantColor CMH Precise MR16 20 & 35W

T5 LongLast. GE Lighting DATA SHEET

T5 Watt-Miser Linear Fluorescent lamps

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

Features. High Brightness LED Light source

DuroSite TM High Bay Lighting

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

High Pressure Mercury

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

LINEA 120 FIXED Colour White = MW Matte White RAL 9016 Colour Black = BL Matte Black RAL 9005 Beam Angle 60 EN60598 / EN62031 / EN62471.

ARTIFICIAL LIGHTING lecture notes

IKEA Light Sources Technical Information Update

Property Risk Management HIGH INTENSITY DISCHARGE ELECTRICAL LIGHTING

GE Lighting. Spectrum Catalogue 2013/14

The most sustainable lighting solution. QL 85W Induction Lighting System

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

GE Lighting. Lighting the future. Your guide to changing to energy efficient lamps

Features. Typical Applications G9. ProLight PEA2-3FVE 3W Warm White AC LED Technical Datasheet Version: DS-0042

Petrol Station Canopies

IVIOS LED III. LUM Technical Information

KATO. LED Lighting High Bay und Low Bay

Contents. Additional Hella Products White Noise Back-up Alarms Switches Camera Systems. Technical Data Hella Test Standards IP Ratings

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Discontinued. LUXEON V Portable. power light source. Introduction

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-2 umodule SPOT PHASED OUT NTC

Fortimo LED Line Gen3

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P340-2 umodule SPOT PHASED OUT NTC

Guide to Starters Guide to Starters Page 1 of 17

Radiance Angle [ ] Nominal Power [W] Color Temp. [K]

Metal Halide Pulse Start vs. Probe Start. By Dick Erdmann GE Specification Engineer

LED Lamp 15W AR111C. A New Experience in Light

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

Distributed Array LED Modules High efficacy solutions for diffuse ambient lighting

Operating Instructions Bedienungsanleitung Mode d emploi

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

InGaN / Sapphire White Water clear. Parameter Rating Unit

AOK i Series LED High Bay / Flood / Tunnel Light

LZC-00MC40. LedEngin, Inc. High Luminous Efficacy RGB LED Emitter. Key Features. Typical Applications. Description

High flux for outdoor applications

E-CORE Candle 6W. Data Sheet 1 / 5

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Delightful light.

Technical Specification

Radiance Angle [ ] Color Temp. [K]

LED SUPERSTAR MR Product description

Application/ Requirements for LED Lighting Products Certification Scheme

Halogen Lamps. Lamp Construction

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

Cree XLamp MX-6 LEDs Data Sheet

No. 3, Gongye E. 3rd Road, Hsinchu Science Park, Hsinchu 30075, Taiwan TEL: Lextar.com 50W-100W COB LED. Updated on 2012/010/11

Industrial Linergy LED

In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).

Urban lighting luminaire ECOLO. Registered models - Design Massimo Sacconi. NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)

JD(Doug) Rooks Western Area Applications Manager

Photosynthesis Light for Horticulture

Product family data sheet

CHM-27 COB Arrays White LED

Nashville Electric Service

G H I J K G DIMMING. QS no dimming 1 0. (10%) 3-wire hot dim EcoSystem (10%) digital dim U 0 Mark 7 (1% HO 5% HE) 0-10 V M 0 Mark 10 (1%) hot dim N 0

Product specifications

SAMSUNG ELECTRONICS LED

ORDER DIRECTLY TODAY AT:

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

Via dell' Industria, S. Vendemiano (TV) Tel Fax Acquisti@elettrolab.

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Bridgelux ES Array Series

Cree XLamp MX-3S LEDs Data Sheet

Guidance for upgrading to GB (IEC : 2005, MOD)

OSRAM DULUX SUPERSTAR MICRO TWIST

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

Available in white (2,600 K to 8,300 K CCT) Maximum drive current: 1000 ma. Wide viewing angle: 120. Electrically neutral thermal path

ADM1TE 5/30A DIN rail single phase two wire energy meter

The right. LEDtube. every time. LEDlamps

LUXEON S. High Flux Density

CERAMIC XENON LAMPS APPLICATIONS FEATURES & BENEFITS VAC CERAMIC XENON LAMPS

3W RGB High Power LED

2D and 2D Watt-Miser. GE Lighting DATA SHEET. Compact Fluorescent Lamps Non-Integrated 16, 21, 28, 38W 2D Watt-Miser and 55W 2D. Product information

Lumination LED Luminaires

Regulation IO-6.0: Electrical Safety Regulations

The Great Internet Light Bulb Book, Part I

Apples & Pears, a CELMA guiding paper: Why standardisation of performance criteria for LED luminaires is important

ARTEMIS acdc1032. A compact, exterior, fully submersible, discrete, triple LED marker light & wallwash luminaire, delivering 350lm.

Product Safety Notice Evolution Floodlight

Lumination LED Luminaires

WL-SWTC SMD White Top View Ceramic LED

Transcription:

GE Lighting Arcstream Single Ended Metal Halide lamps 7W and 15W DATA SHEET Product information Arcstream Single Ended lamp consists of a compact high pressure metal halide discharge operating in a quartz bulb. An outer quartz envelope provides thermal and physical protection. The lamp has a ceramic bi-pin cap. Features Small powerful point source enables accurate optical control in compact fittings Excellent operating efficiency Long life High colour rendering index Choice of wattages and colour temperatures Single easy to use G12 bi-pin cap Good initial and through life colour stability Universal burning Applications Retail Industrial Showbiz Architectural Hospitality Basic data Single Ended UVC Single Ended RG-2 Product Code 97286 97287 88654 88655 Product Description ARC7/T/U/73/G12 ARC7/T/U/742/G12 ARC15/G12/83 ARC15/G12/842 Wattage [W] 7 7 15 15 Weighted Energy Consumption [kwh/1 hrs] 77. 77. 165. 165. Voltage [V] 95 95 95 95 Cap G12 G12 G12 G12 Nominal Lumen [lm] 5 5 1 115 Energy Efficiency Class (EEC) A A A A CCT [K] 3 4 3 4 CRI [Ra] 7 75 8 8 Operating Position Universal Universal Universal Universal Average Life [h] 6, 6, 6, 6, Pack Quantity 1 1 1 1

Dimensions Wattage [W] L1 [mm] L2 [mm] L3 [mm] L4 [mm] L5 [mm] D [mm] 7 3.6 12 87 99 56 23 15 3.6 12 76 88.5 56 21.5 Survival rate and lumen maintenance Average lamp life: 6 hours to 5% failures. Lumen maintenance: 6% (for 7W types) or 8% (for 15W types) at 6 hours. The graph shows the survival of representative groups of lamps operated under control conditions at 5 hrs/ start. Lamp life in service will be affected by a number of parameters, such as main voltage deviations, switching cycle, luminaire design and control gear. The information given is intended to be a practical guide in determining lamp replacement schedules. 7W Lamp survival and lumen maintenance 15W Lamp survival and lumen maintenance 1 8 1 8 15W 6 6 Life survival Lumen maintenance Life survival Lumen maintenance 1 2 3 4 5 6 Burning time (thousand hrs) 1 2 3 4 5 6 Burning time (thousand hours) Run-up characteristics The graph shows a typical run-up characteristic. Times for the light output to reach 9% of the final value are: 7W 8 seconds 15W 6 seconds Hot restrike time 1 to 2 minutes for both lamp ratings, depending on the actual pulse voltage at the lamp. 1 11 1 9 8 7 6 5 3 1 Typical run-up characteristics.5 1 1.5 2 Time from switch on (minutes) Lamp current Supply current Supply power Lamp power Lamp Volt drop Light output 2

Photometric data Nominal Rating 7W 15W Nominal Colour Temperature Correlated Colour Temperature [K] 3, 4, 3, 4, Nominal Light Output Lumen Output (at 1 hours) 5, 5, 12, 11,5 Nominal Colour Appearance Chromacity Coordinates x y.437.4.372.372.437.4.38.37 Colour Rendering General Colour Rendering Index [Ra] 7 75 8 85 DIN 535 Classification 2A 2A 1B 1B Electrical data Based on nominal 3K or K lamp and control gear. Supply power is based on a typical commercially available ballast. Rating 7W 15W Supply Voltage [V] 2 23 2 2 23 2 Lamp Voltage [V] 85 85 85 95 95 95 Lamp Current [A] 1. 1. 1. 1.82 1.82 1.82 Lamp Power [W] 75 75 75 146 146 146 Supply Current [A].46*.43*.41.85.81.76 Supply Power [W] 87 87 88 168 169 17 Power Factor (Lagging).87*.88*.89.9.91.93 % 3rd Harmonic 19 19 13 13 13 Max Line Current During Run-up [A].55.51.47.92.84.76 Failed/Hot Lamp [A].69.72.75 1. 1.45 1.5 Power Factor Correction Capacitor [µf] 1* 1* 1 Relative intensity Relative intensity 5 3 1 5 3 1 3K spectral power distribution 38 48 58 68 78 Wavelength [nm] K spectral power distribution 38 48 58 68 78 Wavelength [nm] *Use a 12µF Capacitor if a power factor >.9 (lag) is required. Supply current is thenreduced at 2V to.42a (.94pF) and at 23V to.a (.94pF). NOTE: Arcstream lamps do not retain the claimed performance if they are dimmed. All the performance data quoted have been measured with the lamp in the base down position and at rated supply volts. Supply voltage Lamps will start and operate with a 1% reduction in rated supply voltage when the correct control gear is used. However, in order to maximise lamp survival, lumen maintenance and colour uniformity, the supply voltage and ballast design should be within ±3%. Supply variations of ±5% are permissible for short periods only. Lamps are suitable for supplies in the range 2V-25V 5/6Hz for appropriately rated series choke (reactor) ballasts. Supplies outside this range require a transformer (conventional, high reactance or CWA) to ensure correct lamp operation. Percentage of nominal 13 1 11 1 9 8 Effect of supply voltage variation on performance 7 9 92 94 96 98 1 12 14 16 18 11 Percentage of rated supply voltage Not Permitted 9-95% Permissible 95-97% Optimum 97-13% Permissible 13-15% Not Permitted 15-11% 3 Lamp Current Lamp Power Supply Power Lamp Current Supply Current Light Output

Fusing of choke/ignitor circuits For a very short period after switch-on, all discharge lamps may act as a partial rectifier and as a result the ballast may allow several times the normal supply current to flow. To avoid nuisance fuse failure the ratings shown below should be used. For further information refer to the publication Fuse Ratings For Discharge Lamps available from GE Lighting. HBC or MCB (type 3 or 4) fuse ratings for single and multiple lamp installations: Number of Lamps 1 2 3 4 5 6 7W Fuse Rating [A] 4 4 4 6 6 1 15W Fuse Rating [A] 4 6 1 1 16 16 Typical superimposed ignitor circuit PHASE NEUTRAL PFC Capacitor BALLAST IGNITOR B Lp N Typical impulser ignitor circuit Warning Arcstream (15W) lamps have an outer bulb made of quartz which transmits UVA and UVB radiation. All metal halide lamps, including Arcstream, operate at very high internal pressures, consequently it is a possibility that in a large installation a few lamps may shatter if run beyond the rated life. To reduce the risk of this happening, continuous operation of the lamps should be avoided and the lamps should be switched off for a brief period at least once every 24 hours. PHASE NEUTRAL PFC Capacitor BALLAST IGNITOR B Lp N FOR THESE REASONS 15W ARCSTREAM LAMPS MUST ONLY BE OPERATED IN A FULLY ENCLOSED LUMINAIRE WITH A UV ABSORBENT FRONT COVER GLASS. Installation, operation and disposal Important The following information gives essential precautions for the safe handling, installation, use and disposal of Metal Halide lamps. Failure to adhere to these precautions could expose the user to harmful UVA and UVB radiation. Installation All lamps should be installed and replaced by an electrician or suitably qualified person who must first isolate the equipment from the electricity supply. Ensure that the replacement lamp is the correct type for the application and is located correctly and firmly in the lamp holder. If the outer bulb is broken or scratched the lamp must not be used. Fingerprints on the outer bulb should be removed using a soft cloth with a small quantity of alcohol based cleaner. Operation During operation parts of the lamp surface may reach temperatures up to 6 C. Liquid condensation droplets or water splashing onto the lamp must be prevented as this may cause the bulb to shatter. The lamp must only be used in a fully enclosed luminaire with a UV absorbing front cover glass that will retain any fragments should the lamp shatter. Disposal Allow a failed lamp to cool and isolate the supply before removal from the luminaire. Small quantities of lamps may be disposed of with ordinary refuse. The lamps should be placed in original or similar packaging before disposal. Large quantities of lamps must be disposed of in accordance with the rules of the local authority. 4

Guidance for luminaire manufacturers Lamp operating temperature limits 7W 15W Max Pin Temperature Limit [ C] 15 15 Max Cap/Bulb Interface Temperature [ C] 25 27 Max Bulb Temperature [ C] 5 55 Reflector design Due to the nature of the arc some separation of colour within the beam produced by a fitting may be experienced. This effect can be minimised by careful reflector design. In general an evenly mixed beam can be achieved by using a parabolic reflector. Any spreading of the beam should be achieved by using a degree of faceting and surface texturing. Narrow angle reflectors should also incorporate a small degree of faceting or surface texturing. Further information and advice can be obtained on the application. Control gear For correct starting and operation it is important that the lamp and control gear are compatible and suitable for the supply voltage at the luminaire. Ballasts The following 7W and 15W ballasts are suitable: (a) Ballasts manufactured for lamps complying with the forthcoming IEC metal halide lamp specification. (b) Ballasts manufactured for lamps complying with the high pressure sodium lamp specification IEC6662. Ballasts should comply with specifications IEC61347-1 and IEC6923. Ballast thermal protection Use on ballasts or systems that are either resistant to or will shut off in event of rectification. Voltage adjustment Additional tappings at ±1V should be provided on series choke ballasts to ensure actual supply voltage and rated voltage of the ballast are within the GE recommended limits. Ballasts rated for 2/23/2V should be used for Europe and Ireland excluding UK mainland. Ballasts with no means of voltage adjustment may be used provided that the supply voltage is maintained within the recommended limits. Ignitors Correct ignitor performance is essential for successful start-ing of the lamp. Superimposed or impulser type ignitors are suitable for use with Arcstream lamps, but it is recommended that only GE approved ignitors are used. Pulse requirements are ±3.5kV peak (minimum) with pulses produced on both mains half-cycles between 6/9 degrees and 2/27 degrees. Ignitors should comply with specifications IEC61347-2 and IEC6927. Timed ignitors Use of a timed or cutout ignitor is not a specific requirement for Arcstream lamps, but it is a good optional safety feature for the installation. The time period must be sufficient to allow lamps to hot restart where the supply is accidentally switched off or a sudden reduction in supply voltage causes the lamp to extinguish. A minimum period of 6 minutes ignitor operation is recommended before the ignitor is automatically switched off. Commercially available 1/11 minute timed ignitors should be used. Approved ignitors for both 7W and 15W ratings Thorn BAG Turgi Tridonic/Zumtobel May&Christie Sabir G53459, G53476 MZN 15S, MZN 25SE, MZN SU ZRM GES, ZRM 1.8ES/2 PTH7* (for 7W only), PTH15* (for 15W only), PAE, PXE AIF *Impulser type must be used in conjunction with appropriate Parry ballast HDZ73 (7W), HSV162 (15W) or HSV163 (15W). You are advised to contact GE Lighting if you wish touse any ignitor not on the above list. Lamp to ignitor cable capacitance To achieve good starting with superimposed types, ignitors must be adjacent to the luminaire. Cable capacitance between wiring from the ignitor Lp terminal to lamp and adjacent metal and/or other cables should not exceed 1pF (<1 metre length) unless otherwise stated by the ignitor manufacturer. When using impulser type ignitors longer cable lengths between ballast and lamp are permissible. For example Parry impulser types can be used with between pf (13 metres) and 28pF (19 metres) of typical cable depending upon lamp rating and supply voltage. PFC capacitors for simple choke circuits Power factor correction is advisable in order to minimise supply current and electricity costs. For supply voltages in the range -25V a 25V rated capacitor with a ±1% tolerance is recommended. Rating 7W 15W Capacitor 1µF µf Suitable lamp holders G12 Any G12 lamp holder complying with the relevant IEC spec. is suitable, e.g.: Bender&Wirth 96 Thorn BJB GL1235 G12-25.89 www.gelighting.com/eu and General Electric are both registered trademarks of the General Electric Company GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted. Arcstream Single Ended Data Sheet July 13