Fire Alarm Control Panel. Operating Manual



Similar documents
Fire Alarm Control Panel. Family. Operating Manual

GST301. (Single Protection Zone) Operation Manual

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

SFC-200 SERIES LCD FIRE ALARM PANEL

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

TS510 & TS500. Installation & User Guide. Compatible Equipment

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Conventional Fire Detection and Extinguishant Control System Specification

ACTIVE 5 ENGINEERING MANUAL

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

FIREDEX Conventional Fire Panels

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Installation and Operation Manual

Using your LED Plus keypad

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

CB200W Water Leak Detection Panel Application Guide

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

500r+ Installation and User Guide

DTW Works Master Specification Version 2006

9448 Installation and User Guide

SmartLine. Conventional Fire Detection Control Panel. Extinguishant system Control Panel. User's Manual. GameOver

User s Manual AURORA 1.2K/2.2K

Modular I/O System Analog and Digital Interface Modules

*.ppt 11/2/ :48 PM 1

GSM HOME SECURITY SYSTEM

INSTALLATION MANUAL PC2525. Version 1.1

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

Repeaters and Mimics Data Sheet

TABLE OF CONTENTS FEATURES

Life Alarm Fire Alarm Controls

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

SECTION DETECTION AND ALARM

AUTODIALLER / QUICKDIALLER - SA132

WD-AMX Water Detection Controllers

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

instabus KNX / EIB System System E F G H

USER MANUAL Online UPS 6K/10K RACK

PC4020CF v3.0 and higher Commercial Fire Installation Guide DLS-3 v1.3

TMS TANK MANAGEMENT SYSTEM

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Manual Ranging MultiMeter

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

ICP-CP500. User's Guide ICP-CP500 Codepads

User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1

ADM1TE 5/30A DIN rail single phase two wire energy meter

14. Troubleshooting Guide

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Car Alarm Series 2 B 2 Buttons

PC Tab Security System INSTRUCTION MANUAL

How To Use A Power Supply Unit (Upu)

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Back-UPS Pro 1300/1500 Installation and Operation

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

PK5500 v1.1 Installation Instructions

OUTPUT CABLE CONNECTIONS:

COLOR VIDEO DOOR PHONE CDV-71BE/D

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Product Information Fire alarm panel 8000 C

MSL1000 Monitored Serial Link Interface Manual V1.01

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

NESS D Zone Control Panel and Dialler OWNER S MANUAL

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

LCD and 16-Zone LED Keypads. User s Manual

Product Data Sheet. User Manual. User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

LITHIUM BALANCE CHARGER

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

RP1r. Extinguishing Control Panel. User Manual (Software version 3.x) 3 zone control panel to protect 1 extinguishing risk

Manual for Fire Suppression & Methane Detection System

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

12 Volt 30 Amp Digital Solar Charge Controller

User Manual Color video door phone

SCORPION. micron security products

USER S MANUAL HSC-24A

SILENT KNIGHT MODEL 5207

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

User Guide. Model Insulation Tester / Megohmmeter

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Transcription:

Fire Alarm Control Panel Operating Manual

CONTENTS ITEM Page Introduction and Characteristics Fire Alarm System Assembly Diagram Fire Alarm Signal Flow Chart Panel Descriptions Standard Detector Wiring Method Method of Wiring Wiring Principle Operating Instructions 1.Fire Surveillance 2.Fire Alarm 3.Reset 4.Fault Alarm 5.Standby Power 6.Alarm Relay Output 7.Fault Relay Output 8.Control Board LED Test 9.Occurrence of Alarm Signal during Testing 10.The Display Module LCD (AH-02412L) 11.Extinguishing Facility (AH-02412E) Installation Location Important Notes On Maintenance 1.Normal State of Control Panel 2.Maintenance of Devices 3.Overall Maintenance Trouble Shooting 1.Malfunction of Zone Indicator & Combination PBL Box 2.Functions of Fuses 3.Causes of Burnt Fuses & Inspection Guidelines 4.Combination PBL Fire Indicating Lamp & Alarm Bell malfunction 5.Zone Fault Indicator & Fault/Disable Indicator light up 6.AC Power Fault 7.Standby Power Fault 8.PCB Connection Fault 9.Ground Fault 10.Zone Alarm Indicator & Fire Alarm Indicator light up Main Specifications 1 2 2 3-5 6 7,8 9 10 10 10 11 11 11 11 11 11 11 12 13 13 13 13 14 14 14 15 15 15 16 16 16 16 16 I

Introduction and Characteristics Introduction Due to the creativity and progress of fire fighting technology among highly developed countries, we never give up any chance to upgrade our new generation fire alarm control panel. We are not only pursuing higher technology level, but also compact design to meet national quality standard... Characteristics This digital control panel primary uses processor to handle relevant signal, which improve most weak points of traditional control panel. See below for more details. (1)The use of microprocessor has improved the unit's correctness that used to be affected by bad characteristic of traditional devices. (2)Uses digital mode to transmit and control signal process, which highly increase the precision of signal. (3)Internal control voltage uses 5V that prevent burning circuit caused by traditional high voltage. (4)Module type design simplified entire system, function up-grade just has to change related module and no need big work to complete it. Thus, users are able to save big bucks on up-grade or repair cost. (5)Microprocessor can be revised according to user's request, its expand ability has much greater than traditional ones. (6)Shortage of terminal has not seen on this unit, up to four sets of signal transfer contacts (relay outputs) are added for new design. (7)Zone isolating button and control board switches are electronic-type and used digital 0 and 1 signals for switch control signal. Also they will not damaged by abnormal high voltage because of undirected control high voltage and interfered by dust, this phenomenon usually happened on mechanical-type switch. 1

Fire Alarm System Assembly Diagram Fire Alarm System Assembly Diagram 1-Heat Detector 2-Smoke Detector 3-Gas Detector 4-Flame Detector 5-Alarm Bell 6-Indicating Lamp 7-Manual Call Point 8-Annunciator 9-Extinguishing Device 10-Control Panel Fire Alarm Signal Flow Chart 2-1.Detector 4-1.Alarm Bell 3.Control Panel 4-2.Indicating Lamp 1.Occurrence of fire 4-3.Annunciator 2-2.Manual Call Point 2

Panel Description(AH-02412) Dimensions and Specifications 130 mm Description 1.Zone Alarm LED 2.Zone Fault/Disable LED 3.Zone Disable 4.Silence Sounders 5.Mute Internal Buzzer 6.Lamp Test 7.Reset 8.Fire Alarm LED 9.Fault LED 10.System Normal LED 11.System Fault LED 12.Supply Fault LED 13.Sounder Fault LED 14.CPU Fault LED 15.Disable LED 16.Key Switch 3

Panel Description(AH-02412E) Dimensions and Specifications 130 mm 3 Active (Nac) Trouble Nac 19 17 18 Description 1.Zone Alarm LED 2.Zone Fault / Disable LED 3.Nac Active LED 4.Nac Fault LED 5.Zone Disable 6.Nac 7.Silence Sounders 8.Mute Internal Buzzer 9.Lamp Test 10.Reset 11.Fire Alarm LED 12.Fault LED 13.System Normal LED 14.System Fault LED 15.Supply Fault LED 16.Sounder Fault LED 17.CPU Fault LED 18.Disable LED 19.Key Switch 4

Panel Description(AH-02412L) Dimensions and Specifications Fire Alarm Control Panel AH-02412L s c ACK Alarm Fault System Normal System Fault Alarm Fault / Disable Supply Fault Sounder Fault CPU Fault Disable Description 1.Fire Alarm LED 2.Zone Alarm LED 3.Zone Fault/Disable LED 4.Zone Disable 5.Silence Sounders 6.Mute Internal Buzzer 7.Lamp Test 8.Reset 9.Supply Fault LED 10.Sounder Fault LED 11.CPU Fault LED 12.Disable LED 13.Fault LED 14.System Normal LED 15.System Fault LED 16.LCD Display 17.Numeric Key 5

Standard Detector Wiring Method Standard Detector Wiring Method Common Line(Zn-) Connect to Control Panel Circuit Line(L) Detector at the end of every Circult is installed with one terminal resistor 4.7k 1/4W Terminal Resistor 4.7K 4.7K 4.7K Control Panel (C) 1.6mmx1 Indicating Lamp 1.6mmx1 Alarm Bell 1.6mmx1 (L)Diameter of Circuit line be 1.0mm~1.2mm (C)Common line 1.2~1.6mm.Limited to seven Circuit lines per wire (according to regulation) Symbols Control Panel Rate of Rise Detector Fixed Temp. Detector Somke Detector Combination P.B.L.Box Manual Call Point Alarm Bell Indicating Lamp 6

Method of Wiring Method of wiring AC Power AC 110V /220V AC 110/220V 50Hz/60Hz Stand by Power DC 24V/A accroding to number of zone Sounder 1 Max. connection = no. of zone x 1.2 Sounder 2 Max. connection = no. of zone x 1.2 Indicating Lamp Max. connection = no. of zone x 1.2 24V DC Output Wiring Fire Relay Output Of Contact Point To Relay Output Device Fault Relay Output of Contact point To Relay Output Device Terminal device 4.7k Z1 220 Zone Z2... Detector 4.7k Z8 Detector 7

Method of Wiring Method of Wiring Control Panel Annunciator Reset 24V DC E1 E2 1 2 3 4 E8 8 9 E1 To Relay Output Device Signal Transfer (Voltage Free Contacts) E2 To Relay Output Device E8 To Relay Output Device S1 To Gas Release Equipment Gas Relay S4 To Gas Release Equipment 8

Wiring Principle Wiring Principle 1. Wiring Material Table (longer distance excluded; please refer to your local regulation) Item Detector Zone Zone Common Line Alarm Bell Fire Indicating Lamp Manual Call Point Earth AC Power Specification Quantity 1.0 ~ 1.2M/M N 1.2 ~ 1.6M/M N 1.2 ~ 1.6M/M 2 1.2 ~ 1.6M/M 2 1.0 ~ 1.2M/M 1.0 ~ 1.6M/M 1 1.2 ~ 2.0M/M 2 Depends on zone device, basically 1/zone. No more than 7 zones per common line. Parallel connect with detectors. Dependents on panel's load. 2. Wire Connection Box In order to facilitate inspection, maintenance and repair, every floor or appropriate area should install a Wire Connection Box in which connecting joints are provided. The Box case shall be waterproof and the wording Fire Fighting Only should labeled on an aluminum plate. 3. Wire-Point Labels and Joint Clips Inside the Control Panel and every Wire Connection Box, the wire points are to be attached to Label Covers or Label Stickers and then connected to the Y-clip. 4.Wiring Method Please refer to Page 6 ~ 8 of this handbook for the wiring of safety equipment. 5. Terminal Resistor Connecting Method Every end of a Detector zone shall be fitted with a resistor (not more than one). 6. Wiring Record Once the external wiring is laid, a record of the detailed external wiring diagram shall be kept for future inspection and repair. 9

Operating Instructions Operating Instructions 1. Fire Surveillance After installed system devices into, the panel, connect with AC supply source and the "System Normal" indicators will lighten up. Fire Indicating Lamp of the combination PBL box light up and surveillance begins. 2.Fire Alarm When detector has detected a signal of fire, the Fire "Alarm" Indicator (red) and the related zone indicator will lighten up simultaneously. The Main Bell and Alarm Bell will also sound. The Fire Indicating Lamp of the combination PBL box will blink. These activities indicate that the fire alarm is valid (1) Main Bell Disable To stop the Main Bell from sounding, press "Mute Internal Buzzer" button the sounding stop immediately. It will resound when next alarm is issued. (2) Alarm Bell Disable (SND1 & SND2) To stop the Alarm Bell from sounding, press "Silence Sounder" button the sounding stop immediately. It will resound when next alarm is issued. (3) Single Zone Relay Output Disable (optional) To stop any zone relay output during alarm, press "Z1 ~Z8" button then the zone alarm LED will off, and the zone fault LED will blink. Press again to start relay output. (4) Gas Release Disable (optional) To stop gas release output after cross-zone action just press "Nac" button. When the "Nac Active" LED turns on means gas release output has completed. Note that you have to switch off the AC & DC power and switch them back on to clear this feature. 3. Reset Once the fire alarm is activated, the Fire "Alarm" Indicator and the Zone "Alarm"Indicator will remain lighten. If the control panel requires starting the surveillance again after the previous fire situation has been resolve, just depress the "Reset" button and wait 5 seconds. However, if detectors have been burnt or the MCP press-down not recovered, reset cannot be activated. For this matter, repair should be completed first, then depress the "Reset"button to reset the system. 10

Operating Instructions 4.Fault Alarm The panel is equipped with "Auto Fault Indication/ Release"function. Should there be a Circuit Break in certain areas, or detachment of the terminal resistor, the "Fault"indicator and the related Zone"Fault/ Disable"indicator will lighten up simultaneously. The internal beeper will sound. Upon repair of the circuit, the mentioned situation above will cease. (1) Disable Fault Sound To stop the fault sound, press"mute Internal Buzzer"button. When new fault alarm received, it will resound. 5.Standby Power The control panel is equipped with automatic rechargeable batteries the stand-by power source (24VDC) shall be installed during operation. When the Main power source has been terminated, the "System Normal" indicator will light off and the"fault" indicators will light up. If the standby power is in trouble, the "Supply Fault"indicator will also turn on. 6.Alarm Relay Output One 'A' contact (24V/3A) for alarm output when any zone in alarm condition. 7.Fault Relay Output One 'A' contact (24V/3A) for alarm output when any zone in fault condition. 8.Control Board LED Test Press the "Test" button, all LED on board will light up and buzzer will sound and reset automatically after 5 sec. 9.Occurrence of Alarm Signal during Testing If there is an alarm signal in any Circuit other than those under testing, the test must be end immediately and handle the alarm signal Circuit first. 10.The Display Module LCD (optional) The LCD is only comes with model AH-02412L and has a backlight display with 2 rows of 20 characters each. By means of the 12 buttons on right side, it is possible to obtain detailed information for the warning signaled LED's on the front panel and set up the security code for protection purpose. A.Input 4-digits security code (xxxx) and then press ACK button to start. 11

Operating Instructions B.12 buttons including 10 numeric,1 select/clear and 1 acknowledge. C.Use S/C for displayed heading selection and information clear, the " " and " " buttons scroll of the manual headings. D.Original screen: first line shows Alarm= 000 Fault= 000 (note: 0 means normal condition); second line shows current date & time (yr/mo/day/hr/min/sec). E.For inconsecutive alarm signal, screen will show 000 but fire indicator will remain ON. For inconsecutive fault signal, screen will show 000 and zone fault indicator will OFF. F.Features as follow: 1.Time setting: After correct time is set up, press "ACK" for completion. 2.Zone status display: a.display current zone status, at normal condition it will show 'No Signal'; press "ACK" and back to last screen. b.display any alarm, disconnection or short; the first line shows event #, zone # and event status. The second line shows the date and time of the event. Press "ACK" and back to last screen. 3.Memory data display: a.255 events memory and display with capital M. b.record all kind of status; the first line shows event #, zone # and event status. The second line shows the date and time of the event. Press "ACK" and back to last screen. 4.Memory data delete: By input access code, memory data will clear automatically and then back to last screen. 5.Access code setting: First enter original code (0000) then enter the access code. To return the original code, press '5' and short the two pins on the right of PCB 528D inside the panel. 6.System information: It shows model #, zone # and version; press "ACK" will back to original screen. 11. Extinguishing Facility (AH-02412E only) The extinguishing system will be activated after fire alarm has issued for 0 ~ 60 seconds with adjustable timer (please refer to the logic switch located on main board, single digit on the right and decimal digit on the left) and gas discharge will automatically turned off after 10 seconds or by pushing the "Nac" button. While activated, the LED (Active) on the panel will be ON until the system's supply power was turned OFF and ON again. When user intends to stop the extinguishing process just press the "Nac" button. The extinguishing facility is only activated when both zone in same area have issued fire alarm. > > 12

Installation Location Installation Location Please refer to your local regulation for installation details... Important Notes On Maintenance 1.Normal State of Control Panel (1)Normal Condition (Fire Surveillance Alert) Under normal conditions, the "System Normal" indicator should light up. All other indicators should be OFF for ready status and Fire Indicating Lamp on the Combination PBL Box should light up. (2)Power Failure When there is a power failure, the "System Normal" indicator should light off and the "System Fault" indicators will light up. 2.Maintenance of Devices (1)If maintenance may cause disturbances to public, appropriate co-ordination must be made before. (2)Priority should be given to those faulty devices in the area. (3)Maintenance should be scheduled at least twice a year and must include both physical and functional inspections. 3.Overall Maintenance Annual overall inspection should carry out by the professional institution or the original equipment manufacturer. Inspection records must be tabulated and kept by a responsible person or the department concerned, to ensure the public safety. (1)Power Supply Check whether the external wiring of the panel its power consumption are within the safety regulation, whether the standby power conforms to specifications and whether the duration of power supply is within the safety regulation. (2)Detectors To perform a site test for the detectors in order to check whether they are functioning properly and also to check the condition of detector's Indicating LED (on the detector's base). (3)Insulation Test The insulation between power terminal of control panel and earth shall have a value of 250V 20M and above. 13

Trouble Shooting Trouble Shooting The Control Panel is produced with an advanced technology and delicate design that is easy to assemble. It requires no special skills to trouble-shoot a malfunction, thus avoiding any teething problems that might be encountered during maintenance. 1.Malfunction of Zone Indicator & Combination PBL Box The system devices are assembled with many single units (refer page 2), either the 'Detectors', 'Circuits' or 'Combination PBL Box ' become defective, it will affect the functionality of the Control Panel. (1)Measure terminal "AC" with a Multi-meter for any voltage. (2)Check whether the "System Normal" indicator is functioning properly. The system should specify 24V DC. (3)Check whether fuses are in good condition. (4)Check whether the external devices and wiring conform to specifications, as stated in this handbook. 2.Function of Fuses The Control Panel has fuses, each fuse with individual protection function. It must not be replaced with fuses that do not conform to specifications or are of bad quality; otherwise we will not be liable for any damage. Burnt fuses are probably caused by external wiring error, short circuit or faulty external devices. (1)AC: Fuse for power source AC. (2)BATT: Fuse for standby power source. (3)SND1,SND2: Fuse for alarm bell. (Resettable type) (4)AUX: Fuse for Combination PBL Fire Indicating Lamp. (Resettable type) (5)DC24V: Fuse for direct current source 24VDC. (Resettable type) 3.Causes of Burnt Fuses & Inspection Guidelines (1)AC Fuse Burnt a.it could be due to excessive voltage supply that causes the AC Fuse to be burnt. b.conformance of Specification (lower-rated fuse may be burnt by a surge of current). (2)BATT Fuse Burnt a.check whether the standby power polarity '+' and '-' have been in reversed position. b.similar to inspection guidelines for AC Fuse, the standby power supply will pass through BATT Fuse when power supply from the Main Source has been cut-off. 14

Trouble Shooting 4.Combination PBL Fire Indicating Lamp & Alarm Bell Malfunction (1)Remove the external wiring of the Fire Indicating Lamp and Alarm Bell. (2)Measure the ( '+' and '-' ) outlet of Fire Indicating Lamp with a multi-meter and Check whether it is read DC24V. Then perform a fire test. Reset after it is completed. (3)Measure the ( '+' and '-' ) outlet of the Alarm Bell with multi-meter. It should not have any voltage supplied. Then perform a fire test and a DC24V voltage should be recorded. Reset after the test. (4)When the test results conform to (2) and (3), it indicates that the control panel is functioning properly. The wires should only be connected after the external wiring have been repaired. 5.Zone "Fault" Indicator & "Fault/Disable" Indicator light up When one or several "Fault/Disable" Indicator and "Fault" Indicator light up simultaneously, it should be regarded as a signal of circuit break. In this instance, inspection and repairs should be carried out in the following manner: (1)Check for any loops in the control panel not use End-of-line resistor. (2)Remove the circuit that in trouble; the disconnection signal should immediately go off. (3)If test results conform to (2), it indicates that the control panel is functioning properly. The wire shall only be connected after the external wiring has been repaired. (4)Inspect the external circuit to check whether last detector has been installed one End of Line Resistor, or improperly installed. (5)Check for any break in the external wiring as well as any dislocation of detectors. (6)Set the multi-meter to mode and measure the malfunction circuit resistance value. The resistance value between the zone line and common line should 4.7k. (7)After removal of the circuit line, there should not be any voltage between the zone line and zone common line. The wire shall only be connected after the external wiring has been repaired. 6.AC Power Fault When AC power is too high, "Fault" & "System Fault" indicators will light up. When AC power is too low, "Fault" & "CPU Fault" indicators will light up. 15

Trouble Shooting 7.Standby Power Fault When there is any problem on Battery, the "Fault" indicator & "Supply Fault" indicator will on and sound. 8.PCB Connection Fault When there is any disconnection between PCBs, the "Fault" indicator will light up & "System Fault" indicator will blink every 0.5 sec. 9.Ground Fault When there is any external wiring has short circuit with earth, the "Fault" indicator will light up & "System Fault" indicator will blink every 0.2 sec. 10.Zone "Alarm" Indicator & Fire "Alarm" Indicator light up When one or more zone "Alarm" indicators and Fire "Alarm" Indicator lighten up simultaneously, it should be regarded as a fire alarm signal. The inspection and repair guidelines are as follows: (1)Remote the circuit that in trouble. Measure between the loop line and loop common line to check for short circuit or resistance value is normal (normal value=4.7k ). (2)After remote the circuit that in trouble, the control panel must be reset. At this moment, the zone indicator should carry a circuit break signal. After repairing the circuit line, re-connect the external circuit line. (3)Check for presence of any short circuit of the external wiring, or any defective detectors. Main Specification Descriptions Remakers Power 220VAC 50/60Hz Others also avilable Voltage range Nominal voltage +- 15% Standby power 24VDC 4Ah Charging voltage, With auto adjustment 26VDC 100mA ~ 400mA current function Loop voltage,current 24VDC;short circuit under 5V 30mA Round-trip under 50 Exterior resistance # of heat detector connected # of smoke detector connected # of fire indicating lamp connected # of alarm bell connected Digital Switch End of line resistor Material Color Accessory functions Max. 30 per loop Max. 30 per loop # of loop x 1.2 # of loop x 1.2 500000 cycle Min. reliability 4.7k 1.2mm steel plate Ivory white Aux. Contacts for signal transfer and computer monitor, MCP contact and phone Jack Mechanic type has no limit One per loop Others also avilable Optional selections 16

AH-02412 Fire Alarm Control Panel