Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

Similar documents
DE Frame with C Series Sidelight

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Seismic Installation for Attic Storage System

AZEK Rail Install Guide

Owner's Manual & Assembly Instructions

Guidelines for Earthquake Bracing of Residential Water Heaters

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Hollow or Cinder Block Wall Mount Job Aid

AZEK Rail Install Guide

RadianceRail Installation Guide

Premier & Deluxe 3-Season Room Sliding Glass Door

Packaged Terminal Air Conditioner Wall Sleeve Installation

Customer Service or visit us online at smithnoble.com. Wood Shutters. Step by Step Installation. Troubleshooting Tips

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Beadboard Wall Bookcase

Guidelines for Earthquake Bracing Residential Water Heaters

March 14, Installation of Bay, Bow and Garden Windows

Installation Manual. Toilet Partitions, Dressing Compartments & Shower Stalls

CRASH RAIL INSTALLATION HEIGHT

PANELIZED HOME INSTALLATION GUIDELINE

Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN

Installation Instructions For Slider Casement Air Conditioners

Basement Window Installation Guide Hopper and Sliding

INSTALLATION INSTRUCTIONS

Installation Instructions

Architect/Contractor Information Package

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Heavy Glass Frameless Shower Door With Return Panel

All-Season Sunroom Sliding Glass Door Installation Instructions

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Horizontal Mini Blinds Installation Guide

Sliding Door Hardware Installation Instructions

Fiberglas, Exterior Wall Thermal Insulation

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES

Window Installation Instructions

Panel Track Installation Guide

Superform Products Ltd.

Clad Direct Glaze Window Installation Instructions

HOW TO INSTALL A BEAUTIFUL NEW KITCHEN

Installation Instructions

Residential Decks. Planning and Development Services Department

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

How to secure your property after a disaster

A701 ( <01>)

Vinyl Greenhouse Window Page 2 of 6 New Contruction Installation Instructions

Residential Deck Safety, Construction, and Repair

Composite Stone Veneer

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

H-Stud Area Separation Wall System

Information Technology Solutions

CEILING SYSTEMS. Between us, ideas become reality. Installing. Suspended Ceilings. North America Version

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Mark Cramer Inspection Services, Inc.

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

2.9 WINDOW & DOOR BUCKS

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: NORSE, INC.

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

SUPER SHED. Indoor shelter for your outdoor tools.

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

Installation Instructions

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

Best Barns USA Assembly Book

AUTHORIZATION TO MARK

WINDOW PANNING AND TRIMS

Beautifully Traditional

MRI RF SHIELDING DESIGN

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

PART 1 GENERAL 1.1 SECTION INCLUDES

Set-Up Instructions. (Liner-Based System) UL LISTED. Important Read set-up instructions before assembly. Report any shortages within 72 hours

INSTALLATION OF A BAY WINDOW

AMF112 Instruction Manual

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

glass & Glazing Products

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

Introduction...COMB-2 Design Considerations and Examples...COMB-3

IF YOU NEED A POLE BARN OR DIY KIT CALL NOW AND LETS MAKE A DEAL

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

Basic Spring Motor Roller Shades

Owner's Manual & Assembly Instructions

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Ceiling Mounted Folding Attic Ladders Installation Instructions

Owner's Manual & Assembly Instructions

The WANZ Guide to Window Installation

WHAT S DIFFERENT. about TimberTech CableRail? Covered under warranty by ONE trusted manufacturer. Saves TIME and EFFORT

Installation Instructions

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

How to Install GoBoard:

TS93 EMR T/PT/TDE. Surface applied door closer

Assembly Instructions ShadeTree Canopy Systems. A wood support constructed with a ShadeTree Bracket System. Garden Getaway

IN00378 (rev A) Corner Entry

Saferand easierinstallation

MGB Chrome Bumper Conversion

Transcription:

Y Parts Included: Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions Tools Required: Power Driver Drill Bit (Determined by fastener) Driver Bit (Determined by fastener) Level Tape Measure Chalk Line Safety Glass Wall Strip Definition of a structural wall: Herman Miller Inc. definition of a structural wall is a load-bearing wall constructed of materials such as poured concrete or concrete block or a composite board (dry wall) attached to metal or wood studs. Composite board (dry wall) must be 5/8 or more thick. Wood studs must be nominal 2 x 4 size. Metal studs must be C channel 20 ga. thick. Metal or wood studs must be on centers no greater than 24, have a maximum height of 14 and restrained at floor and ceiling. Note: Refere to fastener manufacturer s specifications for pilot hole dia. size. IMPORTANT: Save these instructions for layout changes. 1

WARNING! It is the responsibility of the installer to select and install the proper fasteners in a structural wall. Herman Miller does not furnish fasteners or assume liability for their use. Installation guidelines: - Fasteners for attaching into dry wall: #10 pan head machine screw with toggle bolt or hollow wall fastener. Screw length must be determined by wall construction and thickness. Note: Herman Miller, Inc recommends the use of the Toggler brand 3/16-24 Spaptoggle toggle bolt or equivalent for this application. These can be purchased locally, or are available from Herman Miller, Inc. (Product X1191). The fastener selected should have a minimum manufacturer-published tensil strength of 350 pounds when used with 5/8 thick dry wall. - Fasteners for attaching into concrete: #10 pan head sheet metal screw and masonary anchor. Screw length must be determined by wall construction and thickness. Note: Select mansonary anchor with a minimum manufacturer-published tensil strength of 350 pounds. - Fasteners for attaching into studs through drywall: #10 pan head sheet metal screw. Screw length must be determined by wall construction and thickness. WARNING! Improper installation can cause product damage and personal injury Wall strips MUST be attached to structural walls. SEE DEFINITION OF A STRUCTURAL WALL.! WARNING Under no condition may a wall strip be cut to a shorter length. Notice Mount wall strips on wood or metal studs where possible. Studs and walls MUST be fastened to building structure at ceiling and floor. WARNING! Do not mount work surface above 30 for FT191.46 wall strips. 2

Dimensional Considerations: - Vivo TM wall strips must be mounted with the bottom end at 4 above the floor. - Wall strips should be mounted on studs whenever possible. All Vivo TM wall strips are required to be mounted on 24, 30, 36, 42 and 48 centers, modular dimensions. Assembly Instructions: 1 Allow for Wall Hanger Strip and Wall thickness when determining fastener length. TOP 1. Place Wall Strip at desired location on structural wall with end marked Top up and bottom 4 from floor. 2. Mark first mounting hole through hole in Wall Strip. Remove Wall Strip and drill mounting hole. 3. Attach Wall Strip with fastener. 4. Use level to position Wall Strip vertically. 5. Using Wall Strip as template, drill remaining holes. 6. Install fasteners. 4 Customer Supplied Screw Wall Strip 3

2 Chalk Line Mark 7. Strike a level Chalk Line Mark on wall. 8. Install additional Wall Strips as described in step 1 and at distances apart called out in Dimensional Considerations. 3 1 1/2 2 1 1/2 9. If Wall Strip is to be installed in conjunction with Wall Start, install along side or on each side of Wood Block Shim used for mounting Frame to wall. Frame Wood Block Shim Wall Strip 4

Interior 90 Corner Installation 4 10. When an interior corner is involved, all Wall Strip installations should begin at interior corner and be compliant with dimensions shown. Modular Dimension Modular Dimension 4 5

Exterior 90 Corner Installation 1 7/8 5 11. When an exterior corner is involved, all Wall Strip installations should begin at exterior corner and be compliant with dimensions shown. 1 7/8 Disassembly for Recycling: Materials Identification and Segregation: Where possible, plastic components are marked with ASTM recycling codes. Use these codes to identify material type for recycling. Non marked components should be treated as mixed plastic. Ferrous metals can be identified using a small magnet for recycling. Non-ferrous metals should be separated and recycled separately. To disassemble product, reverse steps 11 through 1. 6