Dissolved Oxygen Sensors



Similar documents
Trace Dissolved Oxygen Sensor

For additional information, please visit our website at

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

DISSOLVED OXYGEN PROBE

Submersion/Insertion Toroidal Sensor

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

Toroidal Conductivity Sensor

Sanitary and CIP Toroidal Sensor

ENDURANCE Conductivity Sensors

Submersion/Insertion Toroidal Sensor

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

General Purpose ph/orp Sensors

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Operator Quick Guide EC SENSOR

Milwaukee USER MANUAL

User Guide Dissolved Oxygen Probes

Stainless Steel Dissolved Oxygen Electrodes

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

General Purpose ph/orp Sensor

OxyGuard. Dissolved Oxygen Probe

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

PART 1 - INTRODUCTION...

Powers Controls TH 192 S Single Temperature Room Thermostat

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

ExStik TM ph Waterproof Meters

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

STANDARD OPERATING PROCEDURE Dissolved Oxygen Measurement, Meter Calibration and Maintenance

ATS Overhead Table Shelf System INSTRUCTION MANUAL

5800 Temperature Sensor Cable Assembly

6 H2O + 6 CO 2 (g) + energy

SHOT BLAST CABINET MODEL NO: CSB20B

Ceiling Fan Installation Instructions

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

INFRARED REMOTE CONTROL HELICOPTER

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

GENUINE PARTS INSTALLATION INSTRUCTIONS

Digital inductive conductivity transmitter

REPAIR AND MAINTENANCE MANUAL

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

SenTix 950 SenTix 980

430 Power/Electronics Replacement

DISSOLVED OXYGEN METER Model : DO-5509

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Installation Instructions

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Tri-Homo Style Operation and Maintenance Instructions

Ignition Coil Sealing Instructions Revision 1.0

For safety information, see the ABI PRISM 310 Genetic Analyzer User s Manual (PN or ).

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

81000 Series Aluminum Gate Valve Installation and Repair Manual

Manual for GlobePharma Mini-Press II Rotary Tablet Press

4RU High Density Shelf Installation Instructions

FUEL CELL CAR SCIENCE KIT ASSEMBLY GUIDE. Battery operation instructions:

Rosemount 5300 and 5400 Series Terminal Compartment Spare Part Instruction

CappController Pipette Controller. Operation Manual Version:

INSTALLATION INSTRUCTIONS

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

ALERT SERVICE BULLETIN December 2012 ENGINE FIRE EXTINGUISHER BOTTLE STEM INSPECTION

BATTERIES 2010, 2003 by David A. Katz. All rights reserved. Permission for academic use with original copyright retained.

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

PTU Series Ultrahigh-Purity Pressure Transducers

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

POWERS CONTROL RC 195 Single Input Receiver-Controller

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Reasons for reissue are in Section 6, REVISION SUMMARY.

RayClic Connection System Installation Instructions

TECHNICAL DATA. Dry 122a. November 12, 2013

Installation instructions

DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

2006 JUDY SERVICE GUIDE

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

123 Industrial Loop Road Paynesville, MN Phone:

Mini-led spotlight with magnetic base

Written By: Sam Lionheart

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

SunMaxx Solar Filling Station Operating Instructions

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

3. Loosen 3 x grub screws in the Dec end cap and unscrew the cap and counterweight shaft. NEQ6 Belt Modification Kit.

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Global Water Instrumentation, Inc.

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

PBX Series Quick Fit Connector Bimetallic Steam Traps

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

INSTALLATION INSTRUCTIONS FOR VW MK5

Transcription:

Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit our website at www.emersonprocess.com/raihome/liquid/. 1.0 SPECIFICATIONS Temperature Range: -10 to 130 C (14 to 266 F) Maximum Pressure: 43 psig (400 kpa abs, 4 bar) Measurement Range: 0 to 20 ppm or 0 to 250% saturation, depending on instrument Wetted materials: Stainless Steel (type AISI-ASTM 316 Ti; DIN 1.4571) and EPDM Process connections: Model Hx438: PG 13.5 thread Model Gx448: G 1-1/4 in. Thread Cable Connector: 4-pin Cable Compatibility: Standard 4-pin connector cable Compatible Analyzers: Rosemount Analytical Models, 1055, 1056, 54eA, XMT, and 5081 Compatible Mounting Accessory: Model Hx438: Insertion or Retractable Mounting Assembly Model Gx448: None, mounts directly to the 61mm, G 1-1/4 in. weld-in socket (PN 9160504) WARNING Do not exceed temperature and pressure limitations of 130 C (266 F) and 72 psig (600 kpa abs, 6 bar). WARNING Before removing the sensor, be absolutely certain that the process pressure is reduced to 0 psig and the process temperature is lowered to a safe level! WARNING The electrolyte is highly alkaline. Protect your hands with gloves and use safety goggles. Avoid contact of the electrolyte with the skin, eyes, and mucous membranes

MILLIMETER INCH MILLIMETER INCH MODEL Hx438 MODEL Gx448 2.0 INSTALLATION 2.1 UNPACKING AND INSPECTION Inspect the carton for damage. If damage is found, contact the carrier immediately. 2.2 SENSOR PREPARATION Sensor Preparation Guidelines: Carefully remove the plastic cap covering the sensing end of the sensor. Avoid causing a vacuum by gently and slowly twisting the sensor and cap until it is removed. Sensor is shipped dry, so electrolyte must be added prior to installation. Remove membrane cartridge. Add 1.5 ml of electrolyte to the membrane cartridge. Screw membrane cartridge back onto sensor body. Refer to Section 5.3 for additional details. Connection of the Sensor to the Analyzer/ Transmitter: 1. Wire the sensor to the analyzer/transmitter. See the wiring tables in Section 3.0. 2. Apply power to the analyzer/transmitter. After 2 hours, the sensor should be ready for calibration. The polarization time is necessary to get stable signals from the sensor. If the sensor is disconnected from the analyzer/transmitter for a short time, allow the sensor to stabilize for at least two times longer than the time is was disconnected. Time needed for stabilization should not exceed 2 hours. Mounting Guidelines: Mount the sensor using the PG 13.5 process thread (Model Hx438) or the G 1-1/4 inch thread (Model Gx448). NOTE Do not install the sensor upside down. 2

3.0 WIRING Wiring Model 1056 Wiring diagram to Hx438 Hx438 and Gx448 steam-sterilizable dissolved oxygen sensors use a 22k NTC thermistor. The thermistor is wired to terminals 1 and 3 on TB5. Wiring Model Hx438 and Gx448 Sensors to Model 54eA Analyzer Wiring Model Hx438 and Gx448 Sensors to Model 5081-A Analyzer 3

Wiring Model Hx438 and Gx448 Sensors to Model 1055 Analyzer Yellow Wiring Model Hx438 and Gx448 Sensors to Model Xmt-A-HT-11 Analyzer (Pipe Mount) 4

Wiring Model Hx438 and Gx448 Sensors to Model Xmt-A-HT-10 Analyzer (Panel Mount) 4.0 STERILIZATION Before autoclaving the sensor, cover the connector end of the sensor with a tight protective cap (PN 9160490). If the connector end gets wet despite the protective cap, dry the connector with pressurized air or a hair dryer. Drying prevents corrosion and damage to insulation. No protection is necessary when doing in-situ sterilization. 5.0 CALIBRATION AND MAINTENANCE Dismounting the sensor: Unscrew the free rotating PG 13.5 threaded connector and pull the sensor out of the process or mounting assembly. 5.1 CALIBRATION 1. Refer to the analyzer instruction manual for details. 2. Be sure the sensor has been operating for at least two hours before zeroing and calibrating. 3. Zero the sensor by placing it in nitrogen gas or in water containing about 5% sodium sulfite. If using nitrogen gas, be sure the membrane is dry. Once the reading is stable, zero the sensor. Refer to the analyzer instruction manual for details. 4. If sodium sulfite was used to zero the sensor, rinse the sensor with water and gently dry the membrane. Place the sensor in water-saturated air. Once the reading is stable, complete the full-scale calibration. Consult the analyzer instruction manual for details. 5. Calibration can also be done using air-saturated water or air-saturated medium. Although the sensor has an extremely low oxygen consumption rate, the liquid should be gently stirred during calibration. 5

5.2 SENSOR MAINTENANCE Periodically check sensor response in air and nitrogen. 1. Place the sensor in air. Allow the reading to become stable and note the value. Also note the sensor current, which should be between 40 and 80 na. 2. Place the sensor in nitrogen. A small plastic bag with a stream of nitrogen gas discharging into the bottom works well. 3. After one minute, the sensor current should be less than 2% of the value in air. For troubleshooting information, see Section 7.0. 5.3 REPLACING THE ELECTROLYTE AND THE MEMBRANE CARTRIDGE: Replace the membrane cartridge (membrane kit PN 9160487) as follows: 1. Hold the sensor vertically with the membrane pointing down. Carefully unscrew the membrane cartridge. 2. Carefully clean the tip of the glass body with the polishing cloth included with membrane kit, or clean with the polishing tool in one direction only. WARNING Do not polish in a circular motion. NOTE When replacing the membrane cartridge, do not touch the anode wire. 3. Rinse the sensor under running water and dry it carefully. 4. Check the small o-ring above the glass body. If it is damaged, replace it. 5. Use the plastic pipette in the membrane kit to add 2 ml of electrolyte solution to the new membrane cartridge. 6. Carefully screw the cartridge onto the sensor shaft. If too much electrolyte solution was used, the excess will be pushed out. Wash off the excess electrolyte with water. 5.3 REPLACING THE CATHODE If the sensor stil lhas a sluggish response to saturated air after step 5.3 and/or too small current in air, then the cathode should be replaced. NOTE: The membrane should be changed whenever the cathode is replaced. 1. Put the sensor in an upright position and carefully unscrew the membrane cartridge. 2. Flush the replaceable cathode with deionized water then dry the metal parts. Do not touch anode and cathode. 3. Hold the cathode on the metal part (B) in front of the thread (A) and the sensor on the shaft (C) and pull apart. Just pull, do not turn! 4. Please check that all contacts are dry and clean. 5. Replace cathode. (Part number 24262-00) Rotate the cathode until the correct position is found and then push cathode into the shaft. 6. Check the small O-ring (D) above the cathode. Replace if damaged. 7.Add 1.5 ml of electrolyte into the new membrane cartridge. The pipette must NOT touch the membrane itself! 8. Screw the membrane cartridge onto the sensor shaft. Any spillage of electrolyte should be rinsed away with water (see Safety aspects ). 6

6.0 TROUBLESHOOTING Below is a list of possible problems and solutions for Models Hx438 and Gx448 dissolved oxygen sensors. CURRENT IN AIR TOO HIGH (>80 na at 25 C) SLUGGISH RESPONSE CURRENT IN AIR TOO LOW (<40 na at 25 C) Problem Solution Problem Solution Problem Solution Very thin or defective membrane Replace with new membrane cartridge Contaminated, fouled, or dirty membrane Clean membrane or replace with new membrane cartridge Contaminated, fouled, or dirty membrane Clean membrane or replace with new membrane cartridge Defective glass body or connector Return to Rosemount Analytical, Liquid Div. Loose membrane Replace with new membrane cartridge Dried out electrolyte film Loosen membrane cartridge and tighten Poisoned anode Return to Rosemount Analytical, Liquid Div. Dried out electrolyte film Loosen membrane cartridge and tighten Cathode contaminated by silver Clean cathode with polishing paper. If cleaning does not restore the sensor, then replace the cathode Cathode contaminated by silver Clean cathode with polishing paper. If cleaning does not restore the sensor, then replace the cathode Cathode contaminated by silver Clean cathode with polishing paper. f cleaning does not restore the sensor, then replace the cathode Exhausted electrolyte Return to Rosemount Analytical, Liquid Div. Defective glass body or connector Fill with new electrolyte Membrane replacement kit, which includes electrolyte solution and polishing paper, is PN 9160487. 7.0 SPARE PARTS Part No. Description 9160600 Membrane Service Kit, FAO Style 24262-00 Replacement Cathode/Anode cartridge 9160489 Electrolyte (50m) bottle 9160490 Connector cap for Auto Cleaning 9160484 Service kit for insertion mounting Assembly 9160486 Service kit for retractable mounting assembly 99SQ9275 Special Membrane service kit for harsh CIP 9160487 Membrane Service Kit 7

The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. Credit Cards for U.S. Purchases Only. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2008